Win10 64bit、OPNET14.5、VC6.0
运行32位OPNET,出现下面的错误:
<<< Recoverable Error >>>
Object repository construction failed
due to errors encountered by the binder program (bind_so_msvc)
T (0), EV (-), MOD (NONE), PROC (sim_load_repos_rebuild)
op_win_stdio_patch.obj : fatal error LNK1103: debugging information corrupt; recompile module
<<< Program Abort >>>
Error encountered rebuilding repository – unable to proceed
T (0), EV (-), MOD (NONE), PROC (sim_load_repos_load)
使用Microsoft VC 6.0可能会见到这个问题,解决办法如下:
将目录 <install_dir>\14.5.A\sys\pc_intel_win32\lib 下的两个文件重命名(14.5.A是OPNET版本号):
1、op_win_stdio_patch.obj 改名为: op_win_stdio_patch.vc7.obj
2、op_win_stdio_patch.vc6.obj 改名为: op_win_stdio_patch.obj
注意,务必按上述顺序改动。(by 百思@ Adultf )