[THM] Kaboom — Writeup
Difficulty: Medium
Tags: OT, ICS, Modbus, Siemens S7, PLC, SCADA, pymodbus, python-snap7 Solved: June 2026
Overview
Kaboom drops you into an OT/ICS environment as the operator. The room’s premise: a single crafted Modbus write over-pressurises the main pump, causing a blow-out and flooding the plant with alarms — and somewhere in that chaos, a flag.
The challenge is less about exploitation and more about understanding industrial protocols and the architecture connecting them: a PLC simulation (Siemens S7–300 via Snap7), a Modbus TCP interface, and a web-based CCTV simulator that displays plant status — but, critically, doesn’t read from the protocol you’d expect.
Enumeration
nmap -p- 10.113.138.255 -sVPORT STATE SERVICE VERSION
22/tcp open ssh OpenSSH 9.6p1 Ubuntu
80/tcp open http Werkzeug httpd 3.1.3 (Python 3.12.3) — "PLC CCTV Simulator"
102/tcp open iso-tsap Siemens S7 PLC (CPU 315-2 PN/DP, Snap7-SERVER emulation)
502/tcp open modbus Modbus TCP
1880/tcp open — Node-RED (Express/Node.js, fingerprinted via OpenJS Foundation banner)
8080/tcp open http Werkzeug httpd 2.3.7 (Python 3.12.3), /login requiredFive open services point to a fairly typical ICS lab layout: a web HMI/CCTV view (80), an authenticated web app (8080), Node-RED as a likely middleware/automation layer (1880), and two industrial protocols feeding the simulation — Modbus TCP (502) and Siemens S7 (102).
First (wrong) assumption: Modbus drives the CCTV
The CCTV page polls a simple JSON API every 5 seconds:
fetch('/api/state') // returns { status, video }
// video field is injected directly into:
fetch(`/video?mode=${video}`)Initial testing read/wrote holding registers 0–15 with small values (0, 1, 1000) using pymodbus. Writes were confirmed via a separate read script, but /api/state never changed — CCTV stayed on "Cooling Off, Low Temperature".
Lesson: confirming a write succeeded at the protocol level says nothing about whether the application logic consuming that data actually reacts to it.
Finding the live register
Rather than continuing to brute-force a handful of fixed values, I wrote a small monitor script that reads a wide register range, remembers the previous poll, and only prints what changed:
rr = client.read_holding_registers(address=start, count=chunk_size)
# diff against previous snapshot, print only changed indicesScanning registers 0–999 (in 125-register chunks, due to the Modbus protocol cap per request) showed that only register 0 was “live” — fluctuating in a narrow band (~50–67) that matched normal sensor noise for “Cooling Off, Low Temperature”.
Mapping the state machine
Writing 65535 (max 16-bit unsigned) to register 0 flipped the CCTV status to “High Temperature, Cooling ON” — confirming register 0 was the right target, but this clearly wasn’t the final “blow-out” state described in the room.
Get Bonestorm’s stories in your inbox
Join Medium for free to get updates from this writer.
To map the full threshold structure instead of guessing, I scripted a sweep: write a candidate value, wait for the backend poll cycle, query /api/state, log the result. Sweeping log-spaced values from 0 to 65535 produced exactly two states across the whole register range:
Value range Status Low values (transient, settling) “Unknown State” / “default” video ~90 and above “High Temperature, Cooling ON” / “cooling” video
No value in the entire 16-bit range produced anything beyond “Cooling ON”. This ruled out “just push the number higher” as the answer — register 0 alone caps out at a warning state, not an explosion. Something else was actively keeping the system stable.
Side investigations that turned out to be dead ends:
- Path traversal on
/video?mode=(../app.py, etc.) — sanitised, always fell back todefault.mp4. - Negative/overflow values — a 16-bit register can’t represent anything pymodbus hadn’t already sent as 65535 (its two’s-complement equivalent of -1).
/static/directory brute-force — nothing found.
The actual trigger: Modbus coils, not registers
The CCTV status implied an active “Cooling ON” response — i.e., a safety/regulation mechanism was compensating for the high register value. That pointed away from holding registers (analogue data) and toward coils (binary on/off outputs), which is where a cooling/safety-enable flag would typically live in a PLC simulation.
A coil monitor script (same diff-based approach as the register monitor, but using read_coils) revealed coil 15 set to True — the cooling/safety override keeping the pump from going critical even with register 0 pegged at max.
client.write_coil(address=15, value=False)Flipping coil 15 to False while register 0 was held at 65535 removed the compensating safety logic. The CCTV state progressed past "Cooling ON" into the final blow-out state, and the flag was retrievable from there.
Note on the S7 (port 102) red herring
A teammate suggested pivoting to the Siemens S7 protocol (port 102, Snap7 emulation) instead of Modbus, since S7–300 PLCs typically expose process data via Data Blocks (DB) rather than Modbus registers. This is a reasonable instinct in real ICS engagements — S7 and Modbus often run in parallel on the same PLC, exposing the same underlying process data through two different protocols. In this room specifically, the coil approach via Modbus turned out to be the intended path, but enumerating S7 DBs (python-snap7, list_blocks() / db_read()) is a useful technique to have ready for ICS boxes where the Modbus side is a dead end.
Key Takeaways
- Verifying a write ≠ verifying an effect. A successful Modbus write doesn’t mean the consuming application reacts to it — always check the actual observable output (here, the CCTV API), not just protocol-level confirmation.
- Differential monitoring beats blind brute-force. Logging changes across a wide register/coil range instantly separates “live” process values from static noise, instead of guessing a handful of fixed addresses.
- Map thresholds systematically. Sweeping a value range and logging the resulting application state turns “does this work?” guessing into a clear picture of the underlying state machine — and tells you when you’ve hit a ceiling that can’t be pushed further with the variable you’re testing.
- Holding registers and coils represent different things. Analogue process values (pressure, temperature) live in registers; binary safety/control flags (cooling enable, valve open/closed, alarm reset) live in coils. A system that “resists” an attack at the register level may need the corresponding coil disabled first.
- ICS targets often expose the same process through multiple protocols (Modbus + S7 here). When one path stalls, pivoting to a sibling protocol is a reasonable move — but don’t abandon a working lead (the coil) just because a teammate suggests a different protocol.

![[THM] Forward — Writeup](https://miro.medium.com/v2/resize:fit:1358/format:webp/1*x70Xzg1UeRpWELGnRD3qfg.png)
![[THM] LLMborghini — Writeup](https://miro.medium.com/v2/resize:fit:1358/format:webp/1*uwoQHgR_XY0lJe_JrpbhCw.png)
![[THM] Lockdown — Writeup](https://miro.medium.com/v2/resize:fit:1358/format:webp/1*DNUbd00ZWk9WUXVDK4gl7w.png)
![[THM] Masquerade — Writeup](https://miro.medium.com/v2/resize:fit:1358/format:webp/1*_lNt5wEZxGMJSxw-oSoeSw.png)