<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Intelligent Concrete on Medium]]></title>
        <description><![CDATA[Stories by Intelligent Concrete on Medium]]></description>
        <link>https://medium.com/@Int_Concrete?source=rss-e2ee65b6f29a------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/0*FvvJmau81fO3dgGN.jpg</url>
            <title>Stories by Intelligent Concrete on Medium</title>
            <link>https://medium.com/@Int_Concrete?source=rss-e2ee65b6f29a------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Mon, 16 Nov 2026 20:10:03 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@Int_Concrete/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Wildfires and What They Mean for You — Concrete to the Rescue]]></title>
            <link>https://medium.com/@Int_Concrete/wildfires-and-what-they-mean-for-you-concrete-to-the-rescue-7cbc3cd99b92?source=rss-e2ee65b6f29a------2</link>
            <guid isPermaLink="false">https://medium.com/p/7cbc3cd99b92</guid>
            <category><![CDATA[concrete]]></category>
            <category><![CDATA[science]]></category>
            <category><![CDATA[education]]></category>
            <category><![CDATA[forest-fires]]></category>
            <category><![CDATA[climate-change]]></category>
            <dc:creator><![CDATA[Intelligent Concrete]]></dc:creator>
            <pubDate>Fri, 16 Nov 2018 22:52:15 GMT</pubDate>
            <atom:updated>2018-11-16T22:52:15.697Z</atom:updated>
            <content:encoded><![CDATA[<h3><strong>Wildfires and What They Mean for You — Concrete to the Rescue</strong></h3><p>by Mallory A. Westbrook and David W. Harris, PhD, PE, F.ASCE, F.SEI</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/624/1*ls88v3msVdBUfJiNPS2_vQ.png" /><figcaption>Courtesy Getty Images 2018</figcaption></figure><p>We’re sitting in the laboratory and we can smell smoke. Wildfires are raging in Colorado and although we are south of Denver and the fires are, 45 to 60 miles away, we still see and smell the smoke. I drove through the Black Forest about a week ago and there are still hundreds of charred acres with ash, a few black tree trunks, and serious concerns of flooding and toxic runoff. The Black Forest fire in June, 2013 was one of the worst fire disasters in Colorado destroying over 14,000 acres, 511 homes, and claiming 2 lives (Courtesy Wikipedia, 2018).</p><p>The horrific Tubbs Fire in California’s Sonoma and Napa counties last October tore through more than 36,000 acres, killing 22 people and destroying nearly 6,000 buildings. (Scientific American, 2018)</p><p>The number of wildfires is similar over time while the cost to fight the fires and repair the damage has risen sharply with the US forest Service costs alone rising to $2.4B in 2017. This is due mainly to the buildup of homes and urban development near natural vegetation areas. Researchers define this as the wildland-urban interface, or WUI.</p><p><strong>The Increasing problem</strong></p><p>The WUI in the U.S. increased by 33 percent between 1990 and 2010, to about 190 million acres, according to a study published in March in the <em>Proceedings of the National Academy of Sciences USA</em>. The number of houses within the WUI grew by 41 percent in the same period, an addition of nearly 13 million new homes. Having more structures in the WUI increases not only the damage wildfires inflict (because they are harder to fight), but also the risk that they will break out in the first place.</p><p><strong>Concrete’s contribution</strong></p><p>There are steps that homeowners and developers can take to mitigate that danger, such as using more flame-resistant construction materials. Concrete and concrete products are fire resistant. Concrete does not burn and it does not emit any toxic fumes when affected by fire. Concrete is inert and in the majority of applications, can be described as virtually fireproof.</p><p>Concrete has relatively poor thermal conductivity, heat transfer that enables concrete to act as an effective fire shield not only between adjacent spaces, but also to protect itself from fire damage. Properties of wood and concrete are shown in<strong> Table 1</strong> below as a comparison between the two materials.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/648/1*F_Ff0Ec16Ae5XexbNPBgfA.png" /><figcaption>Table 1 — Thermal Properties (Engineers Handbook)</figcaption></figure><p>As can be seen in the<strong> Table 1</strong>, wood has a lower thermal conductivity than concrete but this is countered by a greater specific heat and a higher density of concrete. These latter properties create a more favorable material for fire resistance as seen in the analysis in the following section. Concrete does not combust but damage can be incurred at high heats. A reduction in strength of approximately one half was shown at temperatures of 650 deg. C ( Bilow, D and M. Kamara, 2008).</p><p><strong>Fire Analysis</strong></p><p>The analysis of fire and heat flow requires very sophisticated numerical techniques. This section uses Energy2D (Concord, 2018) an interactive, visual multiphysics simulation program that models all three modes of heat transfer — conduction, convection, and radiation, and their coupling with particle dynamics (Xie, 2012). It allows the design of “computational experiments” to test a scientific hypothesis or solve an engineering problem without resorting to complex mathematics. Energy2D is a versatile computer-aided engineering (CAE) system for exploring and learning science and engineering through virtual experimentation, investigation, and design. (Concord, 2018).</p><p>The conduction part of Energy2D is highly accurate, but the convection and radiation parts are not 100% accurate. Hence, in cases that involve convection and radiation, Energy2D results should be considered as qualitative. (Concord, 2018). Thus, examples used in this section are not for design but for comparative purposes.</p><p>The conduction properties of wood and concrete are examined in <strong>Figures 2 </strong>and<strong> 3</strong>. The model is shown in <strong>Figure 2</strong> with a wood element and a concrete element. The heat source is set to a typical wildfire temperature of 1200 deg. — C (Babbert, 2011). As can be seen in <strong>Figure 3</strong> wood, modeled as Douglas fir, combusts in approximately 30 minutes.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/416/1*TWe1IJJhmWX24U3to7YFbQ.png" /><figcaption>Figure 2 — Model of Thermal Conduction of Wood and Concrete elements</figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/467/1*ozq-2GEZYNstV23Wj_n9bQ.png" /><figcaption>Figure 3 — Heat Rise in Wood and Concrete elements</figcaption></figure><p><strong>Figure 4</strong> shows an approximation of heat effects within a house due to wildfire temperatures and a burning wood wall on one side of the house. The thermometers shown in the air space are the temperature rise over the ambient (initial) conditions after approximately 1 hour. As noted in many sources the conditions are worst towards the ceiling. To escape a fire — stay low.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/617/1*FpqNGVHMfQRXZF8sCFdVDQ.png" /><figcaption>Figure 4 — Approximate Effects in home due to wildfire</figcaption></figure><p><strong>Figure 5</strong> shows an approximate model similar to Figure 4 but with a concrete external wall. This case shows conditions that are much less severe than the case with wood walls.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/526/1*MCC7UKKjuiDLAN8jK4n94w.png" /><figcaption>Figure 5 — Wildfire conditions with concrete wall</figcaption></figure><p><strong>Homeowners Steps</strong></p><p>There are steps that homeowners and developers can take to mitigate that danger such as using more flame-resistant construction materials Concrete structures perform well in fire with the appropriate design of the structural elements to give the required fire performance and the design of the overall structure to ensure robustness.</p><p>Well planned developments with fire perimeters for fire breaks and access: roads, sidewalks, etc. will aid in stopping fires if they start.</p><p>Concrete is already found in much of commercial construction owing to its strength, versatility, and fire resistance. Residential construction has some, albeit limited use of concrete in construction. It is common to see concrete in foundation walls and basement slabs. Additional use in the homes structure can cost about 3% more than standard wood frame constructions but savings such as a 15–25% savings in insurance (PCA,) can rapidly repay the costs. Concrete wall systems can reduce energy costs by 52% (PCA). Siding for homes is available from concrete product production, as well as concrete roof tiles.</p><p><strong>Summary</strong></p><p>Concrete has relatively poor thermal conductivity, the ability to transmit heat. This enables concrete to act as an effective fire shield not only between adjacent spaces, but also to protect itself from fire damage. Concrete structures perform well in fire with the appropriate design of the structural elements to give the required fire performance and the design of the overall structure to ensure robustness.</p><p>Every for fire resistant addition from concrete will lower fire danger, fire costs, and costs of fire damages remediation. Well planned developments with fire perimeters for fire breaks and access: roads, sidewalks, etc. will aid in stopping fires if they start.</p><p>Concrete is your friend and protector — fire is not.</p><p><strong>References</strong></p><p>Bilow, D and M..Kamara, 2008, Fire and Concrete Structures, Structures 2008 — American Society of Civil Engineers.</p><p>Engineers Handbook, Obtained from the Internet October 10, 2018: <a href="http://www.engineershandbook/">www.engineershandbook</a></p><p>Gabbert, B. 2011, At what temperature does a wildfire burn?, Obtained from the Internet November 6, 2018: <a href="https://wildfiretoday.com/2011/02/26/at-what-temperature-does-a-forest-fire-burn/">https://wildfiretoday.com/2011/02/26/at-what-temperature-does-a-forest-fire-burn/</a></p><p><a href="https://www.scientificamerican.com/author/jason-g-goldman/">Jason G. Goldman</a> , 2018, “<strong>Living on the Edge: Wildfires Pose a Growing Risk to Homes Built Near Wilderness Areas”, </strong>Scientific American — online, (www.scientificamerican.com) Obtained July 17, 2018.</p><p>The Concrete Centre, “Fire resistance”, Obtained from the Internet: <a href="https://www.concretecentre.com/">https://www.concretecentre.com/</a> , July 19, 2018.</p><p>PCA — Portland cement association, “Flash — Federal Alliance for Safe Homes”, <a href="http://flash.org/concrete/">http://flash.org/concrete/</a>, Obtained from the Internet July 19, 2018</p><p>Image from huffingtonpost.com (Black Forest fire) Obtained from the Internet 07/19/2018</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=7cbc3cd99b92" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[What is Soft Water Doing to Concrete?]]></title>
            <link>https://medium.com/@Int_Concrete/what-is-soft-water-doing-to-concrete-5743fa9b80e?source=rss-e2ee65b6f29a------2</link>
            <guid isPermaLink="false">https://medium.com/p/5743fa9b80e</guid>
            <category><![CDATA[engineering]]></category>
            <category><![CDATA[sustainability]]></category>
            <category><![CDATA[development]]></category>
            <category><![CDATA[concrete]]></category>
            <category><![CDATA[climate-change]]></category>
            <dc:creator><![CDATA[Intelligent Concrete]]></dc:creator>
            <pubDate>Wed, 31 Oct 2018 16:25:07 GMT</pubDate>
            <atom:updated>2018-10-31T16:25:07.788Z</atom:updated>
            <content:encoded><![CDATA[<p>by Jon S. Belkowitz, PhD and Mallory A. Westbrook</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/723/1*K_rOSLfOobMy-7gkX-o40w.png" /></figure><h3><strong>What is soft water attack?</strong></h3><p>Soft water attack concrete is considered to occur in areas where the water immediately adjacent to a concrete structure or concrete infrastructure (flowing or standing) is characterized by a low dissolved ion content. When Portland cement-based concrete is in contact with soft water, the calcium hydroxide (portlandite, Ca(OH)2) in the hardened cement matrix is leached out as the water tries to establish an ion balance. The aggressiveness of soft water attack, measured as the rate at which Ca(OH)2 is leached from the cement paste, is considerably increased if the water contains dissolved carbonic acid due to the presence of aggressive CO2 (Ballim et al 2009) and/or the water is flowing with energy and particulates (ie, erosion).</p><h3><strong>Why do we care?</strong></h3><p>This leaching of ions from the hydrated matrix of the concrete composite causes a breakdown and softening of the concrete matrix. This softening normally leads to a breakdown of the hydrated cement matrix and the concrete composite. Depending on the energy and ion content of the soft water, damage can manifest with months and years after placement.</p><p>That all being said, the best approaches to increase concrete resistance to soft water attack are described below.</p><h3><strong>How do we prevent soft water attack?</strong></h3><p>One option is coating the concrete with some type of sealer of sacrificial layer. Epoxy coatings / Silane / Siloxane sealers are sometimes used for lower aggressive or hard to get to areas. The idea is that you create a chemically resistant barrier between the concrete and the soft water. While this method is effective, it is limited in placement to new structures or structures that are not submerged. Retrofitting in place concrete can be difficult and impossible if the concrete is underground, submerged, or in a tidal / splash zone. These coatings will eventually wear down in high-energy water flow environments (from erosion) and need to ripped and replaced. Just like with wharfs that you currently work on, any type of concrete coating must be applied with surface preparation. If the coating is compromised, the concrete will still be susceptible to damage.</p><p>Additionally, Sacrificial concrete layers are recognized as a certain thickness of concrete is placed as a semi-permanent layer that is used to be the first line of defense for the permanent concrete structure of infrastructure. The user is knowingly placing this concrete layer that will get destroyed over time. This layer will extend the life of the concrete structure but like the epoxy coating, by protecting it from attack, will need to be replaced over time.</p><p>Another option is enhancing the concrete mix design. The hydrated cement matrix is the material portion of the concrete composite that is susceptible to attack. Using concrete admixtures, additives, and supplement materials to reduce permeability, reduce the mobility of the bulk-water / pore solution within the concrete, and increase the strength of the Calcium-silicate-hydrate (C-S-H) bonds within the hydrated cementitious matrix. This is normally done by reducing the water-to-cementitious ratio, adding pozzolanic / alumina based materials to increase the degree of hydration and the energy states of the hydrated phases, and including materials that will reduce the migration of water into concrete and through the concrete. Finally, if there is flowing water of the concrete, the materials listed above would be used to increase the resistance to underwater abrasion and the impact of erosion.</p><p>The methods described above would be used to increase the resistance of concrete to both the chemical and physical attack associated with the deleterious environment created by soft water.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=5743fa9b80e" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Where Did All the Fly Ash Go?]]></title>
            <link>https://medium.com/@Int_Concrete/where-did-all-the-fly-ash-go-36089c1efc0?source=rss-e2ee65b6f29a------2</link>
            <guid isPermaLink="false">https://medium.com/p/36089c1efc0</guid>
            <category><![CDATA[science]]></category>
            <category><![CDATA[concrete]]></category>
            <category><![CDATA[sustainability]]></category>
            <category><![CDATA[education]]></category>
            <category><![CDATA[climate-change]]></category>
            <dc:creator><![CDATA[Intelligent Concrete]]></dc:creator>
            <pubDate>Fri, 05 Oct 2018 19:20:23 GMT</pubDate>
            <atom:updated>2020-05-19T14:55:14.053Z</atom:updated>
            <content:encoded><![CDATA[<h4>Mallory A. Westbrook and Jon S. Belkowitz, PhD</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*VG3tRDtTzC3tpE7zy6H81g.jpeg" /></figure><h3>Introduction</h3><p>Concrete is one of the oldest and most reliable construction materials in the world. Concrete is at the foundation of our civilizations providing everything from the sidewalks in urban, suburban, and rural areas; to the enormous concrete dams, like the Hoover Dam, spillways, and locks that hold back awesome rivers, like the Colorado River.</p><p>The purpose of this article is to identify the factors (historical and present day) that explain the title’s question and short and long-term influence on concrete structures.</p><h3>Renewable energy movement and the loss of durable concrete</h3><p>In the last few decades, the renewable energy movement has started gaining traction. The ultimate objective of the renewable energy movement, is to reduce the dependency of fossil fuels, including fly ash, for the world-wide infrastructure. With the ever-growing renewable energy movement and the complete phasing-out of coal usage, the concrete industry has, and will continue to experience a significant decrease in durable concrete.</p><p>ACI recognizes durable concrete as concrete capable of retaining its original form when placed and exposed to its field environment. This includes maintaining concrete quality over a several decade service-life (ACI, 2008).</p><p>Of the many secondary cementitious and pozzolanic materials called-out in ACI 201.2R, Guide to Durable Concrete, Class F fly ash is one of the more popularly used materials. Class F fly ash is a by-product of coal combustion often times referred to as coal combustion residue (CCR) (ACI, 2008).</p><p>Common coal ashes include Class C and Class F fly ash, which originate from the coal combustion residue generated from coal consumption. These ashes are widely used as a supplementary cementitious material to increase the strength and durability of concrete.</p><p>ASTM C 618 designates Class C Fly Ash as ash originating from subbituminous and lignite coals. Its composition consists mainly of calcium, alumina, and silica with lower loss on ignition (LOI) than Class F fly ash.</p><p>ASTM C 618 designates Class F Fly Ash as originating from anthracite and bituminous coals. It consists mainly of alumina and silica and has a higher LOI than Class C fly ash. Class F fly ash also has a lower calcium content than Class C fly ash.</p><p>The significance of Class F fly ash for the concrete industry was characterized by its ability to chemically alter, also known as a pozzolanic reaction, the microstructure of concrete to resist the destructive nature of physical and chemical attack. The reduction in coal consumption as result of the renewable energy movement has led to a reduction in CCR and the Class F fly ash that the concrete industry has relied on for decades. The EIA documents the reduced consumption of coal for the different sectors of our national infrastructure.</p><p>Despite renewable energy milestones, the apocalyptic impact on the national concrete infrastructure and demand of the construction industry could potentially increase the global carbon footprint more than coal burning. This concrete apocalypse will continue to worsen as the renewable energy movement is adopted globally.</p><p>The seeds of the concrete apocalypse began with the introduction of renewable energy initiatives to replace coal power with greener alternatives. Not only did the volume of available CCRs vital for concrete durability decrease, but the quality of CCRs, specifically fly ashes, has also decreased significantly. Despite these reductions in CCR, the demands on the concrete and construction industry continues to increase due to population growth. As a result, concrete is created utilizing inferior fly ash and increased amounts of Portland cement powder.</p><p>The absence of fly ash in the concrete mixture ultimately develops a concrete that is susceptible to premature failures, instead of lasting the entire 20 to 40 year service-life. These premature failures include cracking due to alkali-silica reaction, freeze-thaw damage, deicer damage, and other damage mechanisms. This can lead to steel corrosion, spalling, flaking, and a compromise in the structural integrity and overall service-life of the concrete structure. Concrete structures will need to be ripped out sooner.</p><h3>How do we move forward?</h3><p>To decrease the carbon footprint and maintain/increase concrete durability, it is necessary for the concrete industry to design long-term service-life concrete utilizing CCR alternatives. These alternatives (as well as other SCMs and Alternative SCMs) include matured technologies like micro silica produced from silicon metal and blast furnace slag produced from the reduction of iron ore to iron. Both alternatives have been shown to increase both concrete strength and durability when utilized as a cement replacement (National Concrete Ready Mix Association).</p><p>There are also several emerging additives that result in increased concrete strength and durability. Several liquid additives can be utilized as an addition to or replacement of traditional CCRs and matured technologies. Nanoparticles, like colloidal silica and carbon nanotubes, effectively manipulate the molecular kinetics of cement hydration to increase the strength, durability, and service-life of concrete (J. B. Belkowitz; J. B. Belkowitz; Land).</p><p>Part 2 will go into more detail about the concepts and technologies available and coming out to the market…</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=36089c1efc0" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Concrete Video Games — Part 8, Appendix A]]></title>
            <link>https://medium.com/@Int_Concrete/concrete-video-games-part-8-appendix-a-de49888b013d?source=rss-e2ee65b6f29a------2</link>
            <guid isPermaLink="false">https://medium.com/p/de49888b013d</guid>
            <category><![CDATA[tech]]></category>
            <category><![CDATA[concrete]]></category>
            <category><![CDATA[science]]></category>
            <category><![CDATA[videogames]]></category>
            <category><![CDATA[education]]></category>
            <dc:creator><![CDATA[Intelligent Concrete]]></dc:creator>
            <pubDate>Sat, 14 Jul 2018 21:53:25 GMT</pubDate>
            <atom:updated>2018-07-14T21:53:26.025Z</atom:updated>
            <content:encoded><![CDATA[<h4>Phase Rules [1, 4]</h4><h4>C-S-H</h4><p>When a diffusing CSH species collides with either solid C3S or C2S or previously deposited CSH, it is converted into solid CSH with a probability of 1.</p><h4>CH</h4><p>For each diffusion step, a random number is generated to determine if nucleation of a new CH crystal is probable; if so, the diffusing CH is converted into solid CH at its present location. In addition, if a diffusing CH collides with solid CH, it is converted into solid CH with a probability of 1.</p><h4>FH3</h4><p>For each diffusion step, a random number is generated to determine if nucleation of a new FH3 crystal is probable; if so, the diffusing FH3 is converted into solid FH3 at its present location. In addition, if a diffusing FH3 collides with solid FH3, it is converted into solid FH3 with a probability of 1.</p><h4>Gypsum</h4><p>The diffusing gypsum can only react by collision with some other species in the microstructure. If it collides with solid CSH, it can be absorbed as long as the previously absorbed gypsum is less than some constant (e.g., 0.01) multiplied by the number of solid CSH pixels currently present in the system. If it collides with either solid or diffusing C3A, ettringite is formed. If it collides with solid C4AF, ettringite, CH, and FH3 are formed to maintain the appropriate volume stoichiometry.</p><h4>Ettringite</h4><p>When diffusing ettringite is created, it also reacts only by collision with other species. If it collides with solid or diffusing C3A, monosulfoaluminate is formed. If it collides with solid C4AF, monosulfoaluminate, CH, and FH3 are formed. Finally, if it collides with solid ettringite, there is a small probability that it is converted back into solid ettringite. This latter rule is provided to avoid the possibility of a large buildup of diffusing ettringite in the microstructure.</p><h4>C3A</h4><p>If nucleation is probable or the diffusing C3A collides with solid C3AH6 and precipitation is probable, solid C3AH6 is formed. If it collides with diffusing gypsum, ettringite is formed. If it collides with diffusing or solid ettringite, monosulfoaluminate is formed.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=de49888b013d" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Concrete Video Games — Part 7, References]]></title>
            <link>https://medium.com/@Int_Concrete/concrete-video-games-part-7-references-a49b11130b7?source=rss-e2ee65b6f29a------2</link>
            <guid isPermaLink="false">https://medium.com/p/a49b11130b7</guid>
            <category><![CDATA[concrete]]></category>
            <category><![CDATA[science]]></category>
            <category><![CDATA[education]]></category>
            <category><![CDATA[reference]]></category>
            <category><![CDATA[engineering]]></category>
            <dc:creator><![CDATA[Intelligent Concrete]]></dc:creator>
            <pubDate>Sat, 14 Jul 2018 21:47:37 GMT</pubDate>
            <atom:updated>2018-07-14T21:47:37.088Z</atom:updated>
            <content:encoded><![CDATA[<p><strong>[1] </strong>Bentz, D. P. Influence of water-to-cement ratio on hydration kinetics: simple models based on spatial considerations. Cement and Concrete Research. 36. 238–244. 2006.</p><p><strong>[2]</strong> Mindess, S. Concrete. Wiley and Sons, Inc. 2nd Edition. 2003.</p><p><strong>[3]</strong> Neville, A.M. Properties of Concrete. 2nd Edition. 2000.</p><p><strong>[4] </strong>J. Thomas, Biernacki, J., Bullard, J., Bshnoki, S., Dolado, J., Schere, G., Luttge, A. Modeling and Simulation of Cement Hydration Kinetics and Microstructure Development. Cement and Concrete Research. 2011.</p><p><strong>[5]</strong> D.P. Bentz, National Institute of Standards and Technology Interagency Report, Technology Administration. U.S. Department of Commerce. NISTIR 7232. June. 2005.</p><p><strong>[6]</strong> Sun, Z., Garboczi, E. and Shah, S. Modeling the elastic properties of concrete composites: Experiment, differential effective medium theory, and numerical simulation. Cem Concr Comp. 29, 22–38. 2007.</p><p><strong>[7]</strong> D.P. Bentz, National Institute of Standards and Technology Interagency Report, Technology Administration. U.S. Department of Commerce. NISTIR 7232. 2005.</p><p><strong>[8]</strong> D.P. Bentz and E.J. Garboczi. Percolation of phases in a 3D</p><p>cement paste microstructure model. Cem Concr Comp. <strong>21</strong>. Pp. 325–344. 1991.</p><p><strong>[9]</strong> C.−J. Haecker, E.J. Garboczi, J.W. Bullard, R.B. Bohn, Z. Sun, S.P. Shah and T. Voigt. Modeling the linear elastic properties of portland cement paste. Cem Concr Comp. <strong>35</strong>, 1948–1960 (2005).</p><p><strong>[10]</strong> Sun, Z., Garboczi, E. and Shah, S. Modeling the elastic properties of concrete composites: Experiment, differential effective medium theory, and numerical simulation. Cem Concr Comp. 29, 22–38 (2007).</p><p><strong>[11]</strong> D.P. Bentz, National Institute of Standards and Technology Interagency Report, Technology Administration. U.S. Department of Commerce. NISTIR 7232. June. (2005).</p><p><strong>[12]</strong> CEMHYD3D: A 3D Cement Hydration and Microstructure Development Modeling Package. Version 3.0. NISTIR 7232. June (2005)</p><p><strong>[13]</strong> D.P. Bentz. 3D Computer Simulation of Portland Cement Hydration and Microstructure Development , Journal of the American Ceramic Society, 80 (1), pp. 3–21, 1997.</p><p><strong>[14]</strong> ACI 318–11. Building Requirements for Structural Concrete and Commentary. American Concrete Institute. 2011. Pp. 111–112.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=a49b11130b7" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Concrete Video Games — Part 6, Conclusions]]></title>
            <link>https://medium.com/@Int_Concrete/concrete-video-games-part-6-conclusions-c2e538d5365a?source=rss-e2ee65b6f29a------2</link>
            <guid isPermaLink="false">https://medium.com/p/c2e538d5365a</guid>
            <category><![CDATA[engineering]]></category>
            <category><![CDATA[research]]></category>
            <category><![CDATA[education]]></category>
            <category><![CDATA[science]]></category>
            <category><![CDATA[concrete]]></category>
            <dc:creator><![CDATA[Intelligent Concrete]]></dc:creator>
            <pubDate>Sat, 14 Jul 2018 21:45:45 GMT</pubDate>
            <atom:updated>2018-07-14T21:45:45.847Z</atom:updated>
            <content:encoded><![CDATA[<h4>by Whitney B. Belkowitz and Jon S. Belkowitz, PhD</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*UbqLEJ1a0PcFX1LeDpXOLw.jpeg" /><figcaption>Testing materails in the laboratory.</figcaption></figure><p>In the present work three water to cementitious ratios were introduced to the concrete composites for the determination of benefits ascertained in compressive strength, heat signatures, and hydrated products. The use of modeling and simulation was proposed as a viable option in when analyzing concrete mix design. Several conclusions can be drawn on the comparison and use of laboratory testing and <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> software for concrete mixture design and analysis:</p><ul><li>The similar trends in strength development over time between the experiments and model suggest that the model is a conservative tool for strength design and analysis.</li><li>The accuracy of the saturated model is somewhat reduced for the temperature analysis but still develops similar trends.</li><li>The disagreement in CH measurement is an anomaly, which will be the subject of further investigations.</li><li>The relationships between the three testing methods verify, modeling and simulation as a conservative tool to design and analyze concrete mixtures. The use of model and simulation software cannot replace laboratory concrete mixtures and the associated experiments.</li></ul><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=c2e538d5365a" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Concrete Video Games — Part 5, Kicking the Tires]]></title>
            <link>https://medium.com/@Int_Concrete/concrete-video-games-part-5-kicking-the-tires-25116836d66c?source=rss-e2ee65b6f29a------2</link>
            <guid isPermaLink="false">https://medium.com/p/25116836d66c</guid>
            <category><![CDATA[science]]></category>
            <category><![CDATA[videogames]]></category>
            <category><![CDATA[education]]></category>
            <category><![CDATA[engineering]]></category>
            <category><![CDATA[concrete]]></category>
            <dc:creator><![CDATA[Intelligent Concrete]]></dc:creator>
            <pubDate>Sat, 14 Jul 2018 21:40:21 GMT</pubDate>
            <atom:updated>2018-07-14T21:40:21.755Z</atom:updated>
            <content:encoded><![CDATA[<h4>by Whitney B. Belkowitz and Jon S. Belkowitz, PhD</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/500/1*YI5fJ8q98ZooeI2CX_YffA.png" /><figcaption>Simulated hydrated microstructure in <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a>.</figcaption></figure><h4>Results and Discussion</h4><p>Young’s Modulus — Both the experiments and simulation exhibit a growth in strength of the composite. The Young’s Moduli of the tested samples were derived off of the maximum compressive strength using ACI 318 [14]. The Young’s moduli from the tested sample are greater than the simulated values for all three water to cementitious ratio, in Figure 2. While the discrepancies between the two values stay relatively minor, the trend displays that the discrepancies increase as the samples are left to cure longer. The increase of the Young’s Modulus found in the experimental mixes at later dates could be attributed to the degree and rate of actual cement hydration in the samples not present in the model. For the simulated Young’s Modulus, the progression of cement hydration and strength gain in the model decelerates after maximum degree of hydration is reached; strength growth development reduces.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*0NrZ8NUOF7hRTTr0uC4zDg.jpeg" /><figcaption>Figure 2 — Young’s Modulus from <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> and Laboratory Experiments</figcaption></figure><p>SACC — Figure 3 illustrates that temperature of the experimental calorimetry while Figure 4 shows the calorimetry from <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a>. In Figure 3 the experimental data lacks the distinctive initial heat of hydration from mixing due to initial mixing is missing due to the time lapse between mixing and placement in the SACC. The missing stage can be seen in Figure 4 from <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a>. The sample with the lowest water to cementitious ratio presents the highest temperature during its third hydration stage. This phenomenon was attributed to a reduction in the amount of water in the mixtures and thus replacement of water by cement particles, which would ultimately result in higher initial contact area between anhydrous particles, and water. The outcome is a faster rate of reaction during the sample’s early stages of hydration followed by dramatic increase in temperature. As the water is increased, the temperature over time is reduced, as demonstrated in Figure 3 and Figure 4.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*U2jGr8HI9fLYss3HjXxRUg.jpeg" /><figcaption>Figure 3 — Laboratory semi-adiabatic calorimetry. The distinctive heat rise due to the initial combination and mixing of cementitious constituents and water is missing.</figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*fIXkk82zr7wMe5FMxIhIwA.jpeg" /><figcaption>Figure 4 –VCCTL semi-adiabatic calorimetry. The distinctive heat rise due to the initial combination and mixing of cementitious constituents and water is missing.</figcaption></figure><p>The results from the experimental SACC in Figure 3 clearly demonstrates that a reduction of water to cementitious ratio to greater temperatures. There are some discrepancies with the results established from <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> in Figure 4 that do not agree with the results in Figure 3. As with the Young’s Modulus these discrepancies could be attributed to: (1) differences in the experimental cement and the cement composition input in the model, (2) the simulated samples are cured in saturated condition in <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a>. This results in empty pores immediately being replaced with water during the simulation; which could reduce the simulated temperature gain in the lowest water to cementitious sample and (3) the temperature in the simulations were calculated in saturated environment.</p><p>CH Content — From the TGA it was found the amount of CH in the cured cement composite was reduced with reduction in water content for the experiments. Table 4 documents the change in CH loss for the samples. Based on the results, the lower water content promoted the conversion of CH thereby yielding lower percentages from the TGA. This reduction in CH can be attributed to a reduction in room necessary for the CH to grow. The data from <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> in Figure 5 demonstrates that the software calculated a lower percentage of CH for the higher water content mixture. The <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> does not take into account the room needed for CH grow. The voxels in the simulation convert to CH based on modeled constituents and growth algorithms. Therefore, higher water content affords the hydrated sample a reduction in the growth of CH.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/714/1*AmX_IIcs6DR5GWnR_s-IRg.jpeg" /><figcaption>Table 4 — CH Loss found through Thermal Gravimetric Analysis</figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*tAOchzOzyjuc-NGv6wIQpg.jpeg" /><figcaption>Figure 5 — <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> CH content over time.</figcaption></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=25116836d66c" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Concrete Video Games — Part 4, Materials and Methods]]></title>
            <link>https://medium.com/@Int_Concrete/concrete-video-games-part-3-kicking-the-tires-329888e68656?source=rss-e2ee65b6f29a------2</link>
            <guid isPermaLink="false">https://medium.com/p/329888e68656</guid>
            <category><![CDATA[education]]></category>
            <category><![CDATA[concrete]]></category>
            <category><![CDATA[engineering]]></category>
            <category><![CDATA[cement]]></category>
            <category><![CDATA[videogames]]></category>
            <dc:creator><![CDATA[Intelligent Concrete]]></dc:creator>
            <pubDate>Sat, 14 Jul 2018 21:23:55 GMT</pubDate>
            <atom:updated>2018-07-17T03:19:33.005Z</atom:updated>
            <content:encoded><![CDATA[<h4>by Whitney B. Belkowitz and Jon S. Belkowitz, PhD</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*dwhsF0HX0A8HZDYjSeO4NA.jpeg" /><figcaption>Setting up samples to run concurrently with <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> mixes.</figcaption></figure><h4>Materials</h4><p>A Type I/II Portland Cement (PC) with a Blaine fineness of 3790 cm2/g was used as the primary cementitious material. The composition of the OPC used in the experiments and <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> software is listed in Table 1. For the compression and calorimetry experiments the PC was mixed with potable tap water and a washed alluvial aggregate. The alluvial aggregate contained a grain size distribution of 8.2 mm to 11.2 mm. The absorption of the rounded rock was 1.1% and had a specific gravity of 2.64. Three water-to-cement (w-c) ratios were used throughout the experimentation. The proportions of constituents for the mixes are listed in Table 2.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/282/1*-CyHLTIjN637Fy_vWrdQVg.jpeg" /><figcaption>Table 1 — Phase Composition of Type I/II Ordinary Portland Cement</figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/389/1*aBz57aZrZoIthjbqZnfbNg.jpeg" /><figcaption>Table 2 — Mix Design Constituents for eVCCTL and Experiments</figcaption></figure><p>The composition and parameters presented in Table 1 and Table 3 were used in <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> to create anhydrous microstructures to simulate mixes listed in Table 1. Figure 1 is a result of the <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a>’s rendering of the mix before the hydration process. From this primary rendering, <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> applies dissolution, dissipation and reaction cycle algorithms with conditions shown in Table 3. Iterations of this cycle are converted to real time by using experimentally obtained conversion factor of 3.5 * 10–4 hour/cycle2 [12]. Using the rules shown in Appendix A, <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> simulates whether each individual voxel will react and create hydrated products, remain unreactive, or return to its solidified form [13].</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/516/1*VC1vvrRkViirOX-C5VYrNA.jpeg" /><figcaption>Table 3 — Input Parameters for eVCCTL Models</figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*vGkM76tyt-aXNYdhBwxhuQ.jpeg" /><figcaption>Figure 1 — Microstructure of cement matrix. The centerline represents an aggregate interface. Different shaded spheres represent the many compounds found in the cementitious mixture.</figcaption></figure><h4>Methods</h4><p>Compressive Strength: For mechanical strength simulation, <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> uses a simulated 3D microstructure at given point in hydration to apply finite element method analysis procedure to estimate its moduli of elasticity [9].</p><p>SACC: <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> uses information of heat of formation provided in Table 3 to find the heat of hydration [13].</p><p>CH Content: As for calcium hydroxide content (CH), <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> tallies amount of formed CH as product during the multiple iterations performed to simulate hydration. This provides <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> with how much and when CH is developed.</p><p>To perceive and verify the effect of water on cement hydration process on <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a>, three different mixes, listed in Table 2, were batched. Each w/c ratio provides a different perimeter for <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a>. Hence, three simulations were performed separately to observe the effect of water on cement hydration and effect on its properties. In the end, <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> provides the simulated mechanical strength, temperature and CH concentration values over period of time, which then could be compared with data obtained from physically batched concrete samples.</p><p>To verify the VCCTL results of the modeled mixes, a battery of three experiments were executed:</p><p>Compressive Strength: On the specimen break date, three 50.8 mm diameter by 101.6 mm cylindrical sample were crushed per ASTM C 39 [12]. Through the use of ACI 318, Young’s modulus was determined from the averaged compressive strengths and Equation 2 [14].</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/135/1*Q3mq71BVcegGoiaCnJ5Jfg.png" /><figcaption>Equation 2 — Conversion of f’c to MOE by ACI 318 [14].</figcaption></figure><p>SACC: The semi-adiabatic calorimetric chamber (SACC) was used to measure the effect of the change in water on the heat evolution of the hydrated sample. The SACC was programmed to record the change in temperature for 24 hours with readings taken every 0.2 seconds. The temperature was reported in Celsius (C) to the 0.01 C with an accuracy of ± 0.21 C.</p><p>TGA: Thermal analysis of specimens was performed using a Netzsch STA 449 Jupiter F1 simultaneous thermal analyzer (thermogravimetric analysis in conjunction with differential scanning calorimetry). Scans were performed up to 1000C at a rate of 10C/min. Calcium hydroxide contents were calculated based on differential thermogravimetric analysis curved centered around 460C. Total mass loss between 105C and 1000C along with mass loss between 475C and 1000C were also quantified.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=329888e68656" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Concrete Video Games — Part 3, How Does it Work?]]></title>
            <link>https://medium.com/@Int_Concrete/concrete-video-games-part-3-how-does-it-work-c457d238bfb?source=rss-e2ee65b6f29a------2</link>
            <guid isPermaLink="false">https://medium.com/p/c457d238bfb</guid>
            <category><![CDATA[engineering]]></category>
            <category><![CDATA[videogames]]></category>
            <category><![CDATA[education]]></category>
            <category><![CDATA[concrete]]></category>
            <category><![CDATA[science]]></category>
            <dc:creator><![CDATA[Intelligent Concrete]]></dc:creator>
            <pubDate>Sat, 14 Jul 2018 21:07:36 GMT</pubDate>
            <atom:updated>2018-07-14T21:07:36.472Z</atom:updated>
            <content:encoded><![CDATA[<h4>by Whitney B. Belkowitz and Jon S. Belkowitz, PhD</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/500/1*VHz5Qpg_3QW8kb5iRbrzFg.png" /><figcaption>Figire 1 — An example of the simulated cementitious microstructure from <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a>.</figcaption></figure><h4>Microstructure Development</h4><p>In creating the final concrete composite and its hydrated properties, it is first necessary to develop a picture of the unhydrated concrete composition. <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> randomly places cement particles in a digital box in-order to develop anhydrous microstructure, Figure 1, which can be used to initiate the dissolution and chemical reaction of the cementitious components to develop the hydrated microstructure [12]. This anhydrous microstructure will have characteristics based off of the 2D image and user input a lot of factors such as distribution, surface area, phase volume.</p><p>A three-dimensional (3D) image is developed based on user defined concrete constituents and algorithms designated for constituent distribution. The 3D digital space is made up of voxels designated to the chemical composition and particle size distribution of the material. The randomly oriented cement particles are then designated as silicate or aluminates and then finally as tri-calcium silicates or di-calcium silicates [13]. The end result is a cement microstructure developed in a digital space by a multitude of algorithms.</p><h4>Phase Development</h4><p>Growth of the cementitious microstructure is initiated and progressed in the environmental conditions defined by the user. Growth of reactive voxels propagates based on predefined models for dissolution, diffusion and reaction. An initial scan is made through all elements present in the 3D microstructure to identify voxels in contact with pore water.</p><p>A voxel is determined if it is eligible for dissolution and assigned solubility parameters, which dictate: specific dissolution stage and solubility probability. If both parameters allow dissolution, the particle (collection of voxels) is converted into a collection of ions [12,13]. Diffusion and reaction of the cementitious media is allowed in available pore space. Particle interaction and boundaries are regulated by rules that govern voxel interaction, in Appendix A of this series.</p><p>As hydration in the confined digital space progresses the growth of the cementitious phases change. The connectivity between the particles is defined through percolation theory; the connection between the pores within the hydrated cement matrix [8]. The detailed ascertained from the VCCTL that are connected with percolation include: degree of hydration, connectivity of phases and capillary porosity.</p><p>The hydrated structure is simulated through finite element procedures combined with knowledge of individual phase moduli to quantitatively predict elastic moduli as a function of degree of hydration. The composite can also include the impact of the inert voxels (aggregate, fillers) on the material modeled.</p><h4>Elastic Properties</h4><p>The elastic properties are determined by a differential effective medium theory (D-EMT) by Sun et al which assigns elastic moduli to corresponding bulk paste matrix, interfacial zone (ITZ) between matrix-aggregate and aggregate [13]. In the D-EMT technique, each aggregate particle, surrounded by a shell of ITZ of uniform thickness and properties, is mapped onto an the inert particle with uniform elastic moduli. This multi-scale and phase model is used to map the complex microstructure so the phases can be treated as having uniform properties [13].</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=c457d238bfb" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Concrete Video Games — Part 2, Definitions]]></title>
            <link>https://medium.com/@Int_Concrete/concrete-video-games-part-2-definitions-4ab2e112412b?source=rss-e2ee65b6f29a------2</link>
            <guid isPermaLink="false">https://medium.com/p/4ab2e112412b</guid>
            <category><![CDATA[engineering]]></category>
            <category><![CDATA[science]]></category>
            <category><![CDATA[education]]></category>
            <category><![CDATA[concrete]]></category>
            <category><![CDATA[computer-science]]></category>
            <dc:creator><![CDATA[Intelligent Concrete]]></dc:creator>
            <pubDate>Sat, 14 Jul 2018 20:56:06 GMT</pubDate>
            <atom:updated>2018-07-14T20:56:06.729Z</atom:updated>
            <content:encoded><![CDATA[<h4>by Whitney B. Belkowitz and Jon S. Belkowitz, PhD</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/500/1*VHz5Qpg_3QW8kb5iRbrzFg.png" /><figcaption>An example of the simulated cementitious microstructure from <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a>.</figcaption></figure><p>Concrete is one of the most popular construction materials used throughout the construction industry. Concrete formulation and experiments are needed to determine fresh and hardened properties need to place the material as well as ensure its engineering properties are adequate to support structural loads. Concrete experiments in the laboratory and field require excessive amounts of: time, money, labor, and materials. New means and methods for understand specific mix design is needed.</p><h4>Purpose</h4><p>The purpose of this research was to illustrate a new approach in concrete design and analysis, modeling and simulation, which can establish an approximate understanding of materials and how they combine together to form concrete [1]. This time and material saving technique can be used on a wide variety of concrete types analyzing changes based on material type, shape, chemical composition, as well as curing environment. A specific software package (<a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">Virtual Cement and Concrete Testing Laboratory, VCCTL</a>) was employed throughout this research endeavor as an example of modeling and simulation in concrete formulation [10–13]. Laboratory mixes were batched and cast to compare the laboratory samples to the <a href="https://www.nist.gov/programs-projects/virtual-cement-and-concrete-testing-laboratory">VCCTL</a> model [10–13].</p><h4>Modeling and Simulation Defined</h4><p>The definition of a model in this research endeavor is assumed to be the following: a mathematical expression mathematical expression key principles or rules to represent a physical phenomenon [1,6,7]. A model is a set of mathematical expressions, which describe a physical phenomenon or event. When more complex models are used, fewer assumptions are normally made and the math becomes.</p><p>The most popular concrete model known and used has to be Duff Abram’s w/c law, Equation 1, which was developed in 1919 [2,3]. Though the model is adequate for design and engineering analysis, it requires a lot of assumptions to be made to include — assuming concrete strength is based totally on the hydrating cementitious environment.</p><h4>What is a Concrete Model?</h4><p>In order to distinguish a higher resolution (or more results) from concrete models and simulations, more information is needed about our hydrating materials with respect to: (1) growth over time, (2) thermokinetics of hydrating cement particles, and (3) strength of finished products [1,6,7,10]. By analyzing the modeled concrete, an approximate understanding of concrete strength development can facilitate another method to understanding this complex process. Equation (1) illustrates the inverse relationship between the w/c ratio and concrete compressive strength (f’c)[2,3].</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/67/1*Jd1yMKf0NxaTz29mPWVTiA.png" /><figcaption>Equation 1 — Duff Abram’s w/c law.</figcaption></figure><p>Where K1 and K2 are empirical constants summarizing the effects of cement type, aggregate, curing, testing conditions, and concrete age at the time of test, w/c is the mass of water over the mass of cement, and f’c is the compressive strength of the cured concrete in MPa.</p><p>Given this inverse relation, it would mean that Abram’s law delivers the highest compressive strength value when the w/c is the lowest value. The goal of project was to analyze the impact of different w/c ratios on the mechanical strength of concrete, and to compare the modeling results developed here with associated experimental data.</p><p>Ultimately, concrete models employ mathematical equations that can represent the growth and strength development of our hydrating concrete mixture. From the development of the microstructure to the determination of hydrated and mechanical properties a wide variety of models are taken advantage of in order to represent the concrete composite. These models have been established based on empirical data — the closer we can get to measuring the kinetics of hydration, the more accurate our models and simulations.</p><h4>What is a simulation?</h4><p>A simulation is the collection of mathematical models in a number of routines to express a physical event. When these equations are expressed in the form of changing over time, the mathematical models can be used to predict the change in our materials properties over time. Analyzing this takes a considerable amount of numerical analysis. In lieu of running these analyses by hand — computer software was developed to collect these models and use them analyze change in simulated properties.</p><h4>Advantages of Concrete Video Games</h4><p>The advantages for the application of modeling and simulation in the concrete industry are: (1) saving time and money, (2) approximate understanding of concrete properties due to material changes and (3) design and analysis of new concrete mixtures. With VCCTL, you can create and simulate the hydration of virtual specimens of cement paste, mortar or concrete.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=4ab2e112412b" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>