<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by SHOEBOX Audiometry on Medium]]></title>
        <description><![CDATA[Stories by SHOEBOX Audiometry on Medium]]></description>
        <link>https://medium.com/@SHOEBOX_Aud?source=rss-69d62a4d8850------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/1*RfgKCrDE5ueUWNBQVeaMEA.png</url>
            <title>Stories by SHOEBOX Audiometry on Medium</title>
            <link>https://medium.com/@SHOEBOX_Aud?source=rss-69d62a4d8850------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Tue, 24 Nov 2026 03:11:55 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@SHOEBOX_Aud/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Vision Care & Hearing Health: A Natural Partnership]]></title>
            <link>https://medium.com/@SHOEBOX_Aud/vision-care-hearing-health-a-natural-partnership-47558dbc2a56?source=rss-69d62a4d8850------2</link>
            <guid isPermaLink="false">https://medium.com/p/47558dbc2a56</guid>
            <category><![CDATA[health]]></category>
            <category><![CDATA[business]]></category>
            <category><![CDATA[healthcare]]></category>
            <category><![CDATA[hearing]]></category>
            <category><![CDATA[vision]]></category>
            <dc:creator><![CDATA[SHOEBOX Audiometry]]></dc:creator>
            <pubDate>Thu, 20 Dec 2018 19:36:00 GMT</pubDate>
            <atom:updated>2018-12-20T19:36:00.734Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*stkF8L0LWRLlNV7uacotuA.png" /></figure><p><a href="https://stadelmaier.ch/">Stadelmaier Optik AG</a> has been providing vision and hearing healthcare for more than 50 years. This family run business operates out of 2 locations in Switzerland. They are motivated by seeing how their exceptional products and services help to improve the quality of life for their clients.</p><p>Recently, Stadelmaier acquired <a href="http://www.shoebox.md/">SHOEBOX QuickTest</a> from <a href="http://www.beyond-medical.com/">Beyond Medical Solutions AG</a> (GMS). QuickTest is a simple, self-administered hearing screening test available on an iPad. They set the system up in their optical centers as a way of offering additional services to their clients. While they wait for their eye appointment, or for their glasses to be serviced or repaired, they can perform a quick assessment of their hearing health. The service offers added value for their customers, but it also helps Stadelmaier generate additional revenue for their hearing center.</p><p>In Switzerland, 1 in 10 people say they suffer some hearing loss. And less than 4 out of 10 of them use hearing aids even if they could benefit from them.<a href="https://www.shoebox.md/case-studies/vision-care-hearing-health-partnership/#_ftn1">[1]</a> This is not an isolated problem. According to the <a href="http://www.who.int/">World Health Organization</a> (WHO) 466 million people worldwide suffer disabling hearing loss. By 2050 that number is estimated to grow to 900 million.<a href="https://www.shoebox.md/case-studies/vision-care-hearing-health-partnership/#_ftn2">[2]</a></p><p>It has been well reported that the average person waits 7 to 10 years before deciding to do something about their hearing loss. When they do finally seek treatment, they will often say that the problem only started in the last few months. That is rarely the case. There are many reasons for the long delay. One not to be minimized is the stigma attached to wearing a hearing aid. This often demands an acceptance that “I’m getting older”. But hearing loss left untreated can have much more serious and long-lasting effects. There is even research connecting the dots between hearing loss and dementia.<a href="https://www.shoebox.md/case-studies/vision-care-hearing-health-partnership/#_ftn3">[3]</a></p><p>Given the magnitude of the problem, it is clear that the small number of hearing healthcare specialists cannot handle all the demand for their service. Partnerships with other healthcare providers can play a crucial role. For example, affiliated stores or clinics could help to identify and refer those in need of follow-up services. Stadelmaier Optik AG is a perfect example.</p><p>In addition to their two optical stores, Stadelmaier has a hearing center located on the second floor of the shop in Chur. The hearing center has two goals. First is to educate their optical customers about the problems of hearing loss. The second is to generate business for the hearing center from their existing optical clinic clients. To do this, Stadelmaier turned to BMS in June of 2018 looking for a solution that would allow them to offer hearing screening services in the optical clinic. BMS recommended SHOEBOX QuickTest.</p><p>QuickTest is a simple, self-administered hearing screening test that can be performed in under a minute. It offers a fast, effective, and simple assessment of general hearing health. At the beginning of the test the individual is asked to provide some basic contact information, like email or phone number. At the end of the test, the user will be told if their hearing is fine, or if further testing may be required.</p><p>A big selling feature of the system is that it can be monitored by someone with no special training in hearing health. The optician simply provides some basic instruction on how to get started and then they can leave the user alone to conduct the test themselves.</p><p>For those whose test indicates that there may be some hearing loss, it is a very simple process for the optician to refer the individual to the hearing specialist on the second floor. If the hearing specialists isn’t available at that time — say they were busy with another client — then the optician can book a follow-up appointment at a later date. And if for any reason the appointment could not be scheduled at that time, the individuals contact details were captured at the start of the test, so a future email or phone call can be made to book time into the hearing center.</p><p>And for the client, the value of one-stop-shopping can’t be under estimated. Rather than driving around town to multiple locations for different services, now they can have all of their vision and hearing services provided under one roof.</p><p>Before signing on to a full annual commitment of SHOEBOX QuickTest, Stadelmaier conducted a 3-month pilot project. BMS came onsite for a full day to install and set up the equipment and provide training for the clinic employees. For that 3-month period, they paid $690USD (698 CHF) for 2 systems. That enabled them to:</p><ul><li>Conducted 150 hearing screening tests</li><li>Book 25 appointments into the hearing center</li><li>Sell 4 additional sets of hearing aids</li></ul><p>Given the price of the hearing aids sold, Stadelmaier reported at 1000% return on their 3-month investment.</p><p>“Thanks to the professional support of BMS, the set-up and deployment of our pilot went very smoothly. And the systems quickly gained wide acceptance by our opticians because they are so easy to use,” says Andri Persenico, manager of the hearing center. “Now, we also use them outside of our stores, at trade fairs for example, to help us acquire new customers. We get back in hearing aid sales several times the monthly cost of each system.”</p><p>_________</p><p><a href="https://www.shoebox.md/case-studies/vision-care-hearing-health-partnership/#_ftnref1">[1]</a> <a href="https://www.hear-it.org/switzerland-one-in-ten-say-they-have-a-hearing-loss-">https://www.hear-it.org/switzerland-one-in-ten-say-they-have-a-hearing-loss-</a></p><p><a href="https://www.shoebox.md/case-studies/vision-care-hearing-health-partnership/#_ftnref2">[2]</a> <a href="http://www.who.int/news-room/fact-sheets/detail/deafness-and-hearing-loss">http://www.who.int/news-room/fact-sheets/detail/deafness-and-hearing-loss</a></p><p><a href="https://www.shoebox.md/case-studies/vision-care-hearing-health-partnership/#_ftnref3">[3]</a> <a href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3277836/">https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3277836/</a></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=47558dbc2a56" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[No Matter What They Say — Tablet Audiometry is Here to Stay]]></title>
            <link>https://medium.com/@SHOEBOX_Aud/no-matter-what-they-say-tablet-audiometry-is-here-to-stay-cd64c9f348b8?source=rss-69d62a4d8850------2</link>
            <guid isPermaLink="false">https://medium.com/p/cd64c9f348b8</guid>
            <category><![CDATA[healthcare]]></category>
            <category><![CDATA[tablets]]></category>
            <category><![CDATA[ipad]]></category>
            <category><![CDATA[audiology]]></category>
            <category><![CDATA[hearing]]></category>
            <dc:creator><![CDATA[SHOEBOX Audiometry]]></dc:creator>
            <pubDate>Mon, 17 Dec 2018 19:31:00 GMT</pubDate>
            <atom:updated>2018-12-17T19:31:00.937Z</atom:updated>
            <content:encoded><![CDATA[<h3>No Matter What They Say — Tablet Audiometry is Here to Stay</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*NxSKcQl20ZhblbNhCRDI8A.jpeg" /></figure><p>A shift is happening in Occupational Hearing Conservation. Many of you have embraced this change since the beginning. You can attest to how tablet audiometry — and <a href="https://www.shoebox.md/">SHOEBOX</a> specifically — is helping you be more flexible while saving you time and money on your program and on the services that you provide your clients.</p><p>But as the rest of you do your due diligence to assess the validity of tablet technology, some traditional incumbents have been attempting to instill fear, uncertainty, and doubt regarding this new, innovative way to monitor hearing levels. It makes sense that those who profit from the status quo would be resistant to change. Even if that change benefits service providers and employers alike.</p><p>We realize that by enabling audiometric testing outside of a sound booth in a mobile van, we are disrupting the traditional model of occupational hearing testing. But in doing so, you should know that the clinical validity of our approach and the results we produce is a top priority for our entire team of almost 60 full-time employees.</p><p>You may also be interested to know that 600 customers — some who are Fortune-500 companies — have generated over 100,000 audiograms using SHOEBOX Audiometry. Audiologists and otolaryngologists from institutions including Johns Hopkins, Harvard, and Duke University use, and recommend, this highly adaptable solution. Notably, there are currently no fewer than 40 research projects and clinical trials underway that include SHOEBOX as part of an audiometric testing protocol.</p><p>Can you imagine any audiometer being accepted by these users in these conditions if it hadn’t been proven to produce clinically accurate results?</p><p>The most forward-thinking Hearing Conservationists — whether they manage their program in-house or provide services for their clients — have embraced the benefits of tablet audiometry. Their ultra-portability offers flexibility not possible in a mobile van. Namely, bringing the testing closer to the employee at a time that is most convenient for them. But there are several other important considerations. Where you test, who administers those tests, how equipment is calibrated, how noise is monitored, compliance requirements, and more. Let’s address a few of those now.</p><h3>Open-room testing</h3><p>Although sound booths can make hearing testing somewhat easier, they are not imperative to obtain a clinically valid hearing test. An entire ANSI Standard has been published to address this topic 1 :ANSI S3.1–1999. SHOEBOX Audiometry incorporates several sets of Maximum Permissible Ambient Noise Levels (MPANLs) to choose from depending on the test environment. Should these levels be exceeded during a testing session, there are several types of notifications that SHOEBOX will alert the administrator to.</p><h3>Supervision</h3><p>SHOEBOX Audiometry offers three testing modes — Manual, Automated, or Assisted mode — all of which can cater to the level of supervision that works best for your hearing conservation testing. The testing portion can easily be done without continuous supervision. In studies to date, researchers have reported that many employees prefer the self-testing method to conventional button-press audiometry. Whether you run your program in-house or provide testing as a service, leaving the employees to self-test can free up time for your administrator to perform other tasks.</p><h3>Daily Calibration Check</h3><p>SHOEBOX Audiometry offers a special function where a daily tone check can be easily performed and documented within seconds. Testing all OSHA frequencies by means of a biological verification would take approximately 8 minutes per testing day.</p><h3>Calibration</h3><p>All SHOEBOX transducers are calibrated before they are shipped. ANSI/ASA S3.6–2010 requires calibration to within +/- 3dB accuracy. Our various transducers are calibrated to a much higher accuracy of +/- 0.1dB.</p><h3>Validation</h3><p>There are a growing number of independent and peer-reviewed published validation studies examining different aspects of the SHOEBOX Audiometry family of products 2,3,4. These studies provide scientific calculations of sensitivity and specificity in various test environments with both a 5- and 10- dB comparative criteria. For several decades +/-10 dB was considered the acceptable test-retest credential for clinical equality in audiometry. We agree that +/- 5dB is a better comparator and SHOEBOX Audiometry demonstrates excellent reliability here. Several of these validation studies compare the Automated Mode of SHOEBOX Audiometry to conventional audiometry done by an audiologist in a double-walled sound booth with excellent results. Note that this level of accuracy is not what is being provided in many mobile hearing testing units. Often times, mobile testing trucks are using audiometers that are 30 years old and staffed by unskilled technicians. These audiometers are not known to be as accurate as the advanced clinical audiometers compared to in our studies. Our testing algorithm is highly sophisticated and employs smart algorithms to monitor for patient compliance and response accuracy. Furthermore, our customers report that in many cases the quiet clinic rooms where they test with SHOEBOX Audiometry have less environmental noise than experienced in mobile vans.</p><h3>Sound Level Monitoring.</h3><p>The built-in iPad microphone does not exhaustively meet the technical specifications for an ANSI Type-2 Sound Level Meter (SLM), mainly due to its form factor and recalibration challenges. However, we have compared the iPad microphone to a Type-2 SLM and obtained acoustic equivalency in its ability to measure frequency-specific ambient noise levels. Notably, if a SHOEBOX customer would like to use a Type-2 SLM, there are many third-party options that can easily be used in conjunction with our mobile system. SHOEBOX offers several options for ambient noise monitoring at different stages of testing. Furthermore, to address the issue of background noise, SHOEBOX Audiometry offers noise-attenuating headphones that effectively insulate the employee’s ears against a significant amount of ambient noise during testing.</p><h3>OSHA Compliance</h3><p>To be clear, OSHA doesn’t endorse or certify audiometers. We do not claim that they do. We do, however, meet (and exceed) the requirements for an audiometer to be used in an OSHA-compliant hearing conservation program.</p><h3>Medical Device Compliance</h3><p><a href="https://www.shoebox.md/">SHOEBOX Audiometry</a> is listed with FDA, Health Canada, and the EU. We maintain compliance to the ISO 13485 medical device quality standard and are audited annually by a third-party assessor. We meet or exceed all the requirements for a Type 3 diagnostic audiometer under ANSI/ASA S3.6–2010 and IEC 60645–1–2017 standards.</p><p>There are a variety of tablet audiometers on the market, many of which are designed to be screening tools used by individual consumers to validate their own hearing. They are not designed to act as medical devices. Sometimes people confuse the two. Our team of experienced and dedicated clinical, product, and market professionals are proud to offer a highly sophisticated and customizable hearing health solution, not a simple screening tool.</p><p>The bottom line is that SHOEBOX Audiometry is potentially more accurate than testing in mobile vans, is preferred by the majority of employees over conventional testing methods and exceeds OSHA’s audiometer requirements.</p><p>We hope that as you evaluate modern, mobile solutions for your Hearing Conservation program or practice that you will consider SHOEBOX Audiometry. If you are met with any reservations, reach out to us and give us a chance to respond. But we’re sure you’ll agree — this is the future of Occupational Hearing Conservation. Are you ready to make the shift? If so, consider <a href="http://www.shoebox.md/demo">booking a demo</a> and let us show you how to get started today.</p><p>— — —</p><p>References:</p><ol><li><a href="https://www.whisperroom.com/pdf/ANSI-ASA-S3.1-1999-R2008.pdf">Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms. ANSI S3.1–1999. New York: Acoustical Society of America.</a></li><li><a href="http://journals.sagepub.com/doi/abs/10.1177/0194599816683663">Saliba, J., Al-Reefi, M., Carriere, J.S., Varma, N., Provencal, C., Rappaport, J.M. Accuracy of Mobile-Based Audiometry in the Evaluation of Hearing Loss in Quiet and Noisy Environments. J. of Otolaryngol Head and Neck Surg. 2016 Dec 1 DOI: 10.1177/0194599816683663 PMID:28025906</a></li><li><a href="https://www.ncbi.nlm.nih.gov/pubmed/26183518">Thompson GP, Sladen DP, Borst BJ, Still OL. Accuracy of a Tablet Audiometer for Measuring Behavioral Hearing Thresholds in a Clinical Population. J of Otolaryngol Head Neck Surg. 2015 Nov;153(5):838–42. DOI: 10.1177/0194599815593737 PMID: 26183518.</a></li><li><a href="https://www.ncbi.nlm.nih.gov/pubmed/23663317">Yeung J, Javidnia H, Heley S, Beauregard Y, Champagne S, Bromwich M. The new age of play audiometry: prospective validation testing of an iPad-based play audiometer. J Otolaryngol Head Neck Surg. 2013 Mar 11;42:21. DOI: 10.1186/1916–0216–42–21 PMID: 23663317</a></li></ol><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=cd64c9f348b8" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[A Hearing Health Mission to Peru]]></title>
            <link>https://medium.com/@SHOEBOX_Aud/a-hearing-health-mission-to-peru-883299e4f79a?source=rss-69d62a4d8850------2</link>
            <guid isPermaLink="false">https://medium.com/p/883299e4f79a</guid>
            <category><![CDATA[outreach]]></category>
            <category><![CDATA[mission]]></category>
            <category><![CDATA[health]]></category>
            <category><![CDATA[audiology]]></category>
            <category><![CDATA[hearing]]></category>
            <dc:creator><![CDATA[SHOEBOX Audiometry]]></dc:creator>
            <pubDate>Wed, 12 Dec 2018 18:01:01 GMT</pubDate>
            <atom:updated>2018-12-12T18:01:01.000Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*PlWq6qiUpdK1InTnDpCejQ.jpeg" /></figure><p>Half a billion people have trouble with regular conversation due to disabling hearing loss and 80% of them live in the developing world. For people in this situation, it means a lower income, poor educational achievement and a cycle of poverty. However, some groups like <a href="https://www.wwhearing.org/">World Wide Hearing</a> (WWH) and <a href="http://www.shoebox.md/">SHOEBOX Audiometry</a> are on a mission to provide access to affordable hearing healthcare — from testing to diagnosis to rehabilitation. I joined them for a hearing health mission in Peru last November for a transformational 8-day medical mission along with volunteers from the <a href="http://www.cheo.on.ca/">Children’s Hospital of Eastern Ontario</a> (CHEO), <a href="https://www.uottawa.ca/en">The University of Ottawa</a>, <a href="http://www.discovervibes.com/">VIBES</a> and <a href="https://www.hear-the-world.com/en">Hear the World Foundation</a>.</p><p>WWH has set a goal to provide 30,000 hearing tests for children who otherwise wouldn’t have access. Peru is in particular need due. They have a shortage of audiology services with only 10 audiologists in a country of almost 32 million people. They also suffer limited access to hearing aids due to a low average monthly income of around $600. Interestingly, while hearing loss remains an underserved area in healthcare the Peruvian government has committed to developing a universal hearing screening program. When fully implemented, all babies would be tested at birth. At present only 20% of children are screened so there remains a huge gap in services, resources, and programming for children with hearing loss.</p><p>One key piece in solving the global hearing healthcare crisis is the ability to improve access to simple, inexpensive, and reliable testing. As an ENT physician at CHEO, I see the same problems in Canada’s North and rural areas. It is clear that a better understanding of the causes, types, and location of people with hearing loss is needed to advocate for the resources required for hearing rehabilitation. One of the exciting aspects of this Peru project is that it will be the first time that data from Peru will be collected in a single large database that can be used to help us understand hearing loss.</p><p>SHOEBOX worked with WWH by providing the iPad audiometers, support, software, and access to a global medical database. The CHEO team provided medical support, nursing, volunteer training, and documentation. Together with the other volunteers, there were about 20 people participating in the mission. The entire team worked with 3 local coordinators to visit clinics, schools, and orphanages providing hearing screening and medical services followed by rehabilitation where needed.</p><p>Some of the time was also spent on educational work. Lectures were given to students, speech pathologists, community physicians, technicians, and ENT residents on various ear related pathologies and skills. At the end of the trip, 40 new technicians were trained and left behind to continue the work.</p><p>Hearing loss is an invisible disability and as such, it is hard to recognize without proper screening. However, the improvements made by treatment are so dramatic that it is well worth the effort to identify appropriate patients. Out of the 2,100 children screened over 10 days on this mission, 34 were identified with hearing loss and 12 were candidates for further hearing rehabilitation. There is no question that their lives have been positively altered as a result.</p><p>While the outcomes are clearly desirable, the provision of care in low and middle-income countries is fraught with difficulty. Local engagement, longitudinal care, and sustainable solutions are three important aspects to the success of outreach programs. Through WWH, local employees worked with governments, school boards, teachers, and healthcare to develop a screening program that was both acceptable to the population but also well understood and efficient. The inclusion of local assistance, trainees, and volunteers were essential. However, screening for disease is only as good as the proposed treatment. Hence, being part of a longitudinal program that provides follow-up is essential. Finally, the solutions proposed must be sustainable in the local environment. This means that mechanisms for equipment repair, services, and the provision of batteries must be considered.</p><p>We encountered additional challenges when moderately quiet environments for hearing screening weren’t available. However, with the use of noise occluding headphones and noise monitoring software, we were able to manage most cases. Ideally, rooms far away from regular school activity can be secured, and lines of waiting children can be kept away from testing areas. The most efficient day of screening was achieved by those who facilitated the easy flow of children in and out of the screening area. Furthermore, knowing the timing of each activity allowed us to apply the appropriate number of people to each station. For example, we had 8 screening units, 2 otoscopy stations, 2 secondary testing stations and 1 medical ENT. This ratio proved to be the most efficient.</p><p>In North America, hearing loss is the most common workplace injury that many of us will encounter. Similarly, age-related loss is also likely to affect most of us at some point. While the impact of hearing loss is important in adults it is even more critical to the normal social development of children. The 10-day mission in Peru was a small step toward delivering on our promise of hearing healthcare for everyone.</p><p>Written by: <a href="https://www.linkedin.com/in/matthew-bromwich-92569a10/">Dr. Matthew Bromwich</a></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=883299e4f79a" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[What Do We Mean by Frequency and Intensity in Audiometric Testing?]]></title>
            <link>https://medium.com/@SHOEBOX_Aud/what-do-we-mean-by-frequency-and-intensity-in-audiometric-testing-9349d25f912e?source=rss-69d62a4d8850------2</link>
            <guid isPermaLink="false">https://medium.com/p/9349d25f912e</guid>
            <category><![CDATA[hearing]]></category>
            <category><![CDATA[frequency]]></category>
            <category><![CDATA[intensity]]></category>
            <category><![CDATA[hearing-loss]]></category>
            <category><![CDATA[audiology]]></category>
            <dc:creator><![CDATA[SHOEBOX Audiometry]]></dc:creator>
            <pubDate>Tue, 04 Dec 2018 14:51:00 GMT</pubDate>
            <atom:updated>2018-12-04T14:51:00.698Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*c2zhLGvqYQLs473gpcUSpQ.jpeg" /></figure><p>Even during times of near total silence, we will almost always experience some amount of background noise. How well we hear it, and how distracting it may be, depends on its frequency and intensity, as well as our individual hearing ability.</p><p>Sound is a type of energy comprised of vibrations that travel through a transmission medium such as gas, liquids, or solids. These vibrations move in waves creating compressions and refractions. Once these waves reach the ear, the vibrations create movement through the eardrum allowing us to hear these vibrations as sounds.</p><h3>What is ‘Intensity’ in Audiometric Testing?</h3><p>We often turn up the volume to hear our favorite song on the radio more clearly, to drown out the background noise when watching television, or to draw focus to the things we really want to hear. But turning up the volume isn’t always the ideal solution, and can actually be a key identifying factor in determining hearing loss.</p><p>Volume — also known as intensity- are the levels at which sounds can be heard. When performing a hearing test, clinicians — including audiologists, hearing instrument specialist, and hearing technicians, use different levels of intensity for specific sounds that are then presented one ear at a time to the client.</p><h3>How is it Used?</h3><p>Intensity is used in audiometric testing to understand the volume level at which a specific frequency can be heard by the client. It is measured in decibels (dB) distributed at different increments throughout the testing process. The range of human hearing is typically between -10dB and 120dB. Presentation levels are determined by the audiologist starting at a clearly audible level and lowering using a bracketing technique until the softest level at a particular frequency is identified.</p><p>As far as loudness — or intensity — is concerned, humans can generally start to hear at -10dB. The average human conversation registers at roughly 60dB. But once sound levels (loudness) start to reach 85dB, they can be considered dangerous to long-term hearing, especially if an individual is exposed for prolonged periods of time.</p><h3>What is ‘Frequency’ in Audiometric Testing?</h3><p>We’ve all seen the dog who comes running to his master after a whistle is blown that none of us could here. That’s because the frequency of a dog whistle can be undetectable to the average human ear. Frequency, also known as pitch, is used in conjunction with different intensity levels to help determine hearing abilities.</p><p>Typically sounds characterized as ‘low frequency’ are considered to be deep noises — think low rumbling thunder or the sound of a tuba — and ‘high frequency’ sounds (a squeak, squeal, or a child’s voice) have a high pitch.</p><p>The pitch of a frequency is determined by the length of the sound wave. The shorter the wave length, the higher the frequency pitch.</p><h3>How is ‘Frequency’ Used?</h3><p>Frequency, measured in Hertz (Hz), is used to establish the levels of intensity of specific tones that can be heard by the patient. It is commonly stated that a healthy young person can hear frequency ranging from 20Hz to 20kHz. Audiometric testing is generally performed at 250–8000Hz since this range represents the human speech spectrum.</p><p>Everyone is unique in their ability to hear different frequencies at different intensities. There are a number of factors that play into this differentiation including age, overall health, profession, past noise exposures, and daily routines. Using this information, clinicians are able to clearly pinpoint specific types of hearing loss, and make recommendations for treatment and the healthy maintenance of hearing levels.</p><h3>Reading an Audiogram</h3><p>Audiology utilizes a number of unique tools in order to accurately read and interpret the overall status of a patient’s hearing ability. Audiometers, including <a href="http://www.shoebox.md/">SHOEBOX Audiometry</a>, work by presenting a series of tones at varying frequencies and intensity levels. The patient is then expected to identify when they hear those tones, even if they are barely perceivable. The results are recorded as an audiogram which provides a graphical representation of the hearing test results.</p><p>Audiograms use a grid pattern with a vertical and horizontal axis. Located on the axes are the intensity (y-axis) and frequency (x-axis) levels. When the softest level of a particular tone that the client is able to perceive is identified (also known as a threshold), a data point will be inserted onto the graph, displaying the results.</p><p>Each ear is displayed using unique symbols in order to properly distinguish results. Specific symbols, often presented in red, are used to display the results for the right ear. Another set of symbols, often presented in blue, are used to represent the left ear. In interpreting the various symbol sets, clinicians are able to determine the exact levels of the client’s hearing and qualify the type of hearing loss which determines potential next steps.</p><p>Many factors influence whether or not an individual is able to hear different sounds. We hope you have learned a thing or two about some of the key aspects of human hearing. The more we know, the more we can protect this wonderful sense that helps so many of us effectively communicate and enjoy the magical sounds of life.</p><p>Written by: <a href="https://www.linkedin.com/in/trevor-griffith/">Trevor Griffith</a></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=9349d25f912e" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Long Term Effects of Pediatric Ear Infections]]></title>
            <link>https://medium.com/@SHOEBOX_Aud/long-term-effects-of-pediatric-ear-infections-8b438904d49b?source=rss-69d62a4d8850------2</link>
            <guid isPermaLink="false">https://medium.com/p/8b438904d49b</guid>
            <category><![CDATA[health]]></category>
            <category><![CDATA[pediatrics]]></category>
            <category><![CDATA[children]]></category>
            <category><![CDATA[hearing]]></category>
            <category><![CDATA[healthcare]]></category>
            <dc:creator><![CDATA[SHOEBOX Audiometry]]></dc:creator>
            <pubDate>Sat, 24 Nov 2018 17:41:01 GMT</pubDate>
            <atom:updated>2018-11-24T17:41:01.663Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*xvfskMQdKWfb-7iLAFbMww.png" /></figure><p>Roughly 80% of children will have at least one ear infection before the age of three. Almost all of them will fall victim to at least one before they turn six. And they are the most common reason why parents bring their children to the doctor’s office. Although anyone can develop an ear infection, children, and particularly those under seven years of age, are particularly susceptible. Left untreated, the long term consequences can be surprising, and severe.</p><h3>What is an Ear Infection?</h3><p>An ear infection, also known as otitis media (OM), is the result of fluid that builds up behind the eardrum producing bacteria and causing an inflammation of the middle ear. There are three different types of ear infections.</p><h4>Acute otitis media (AOM)</h4><p>This is the most common of the three and is the most frequent diagnosis in sick children. It’s particularly prevalent in infants and preschoolers. It causes parts of the middle ear to become infected and swollen due to fluid being trapped behind the ear drum. This bacterial buildup dampens the vibrations of the eardrum, typically resulting in short-term hearing loss for the duration of the infection. Severe cases may even result in a bulging or perforated eardrum — causing significant pain in the ear. If this happens, medical treatment may be required in order to treat the perforation in the eardrum.<br>Chronic ear drum perforations become serious when they fail to close up on their own. The perforation may become big enough that the eardrum cannot move correctly — this then affects the way sound reaches the organ of hearing, potentially causing <a href="https://www.asha.org/public/hearing/Conductive-Hearing-Loss/">conductive hearing loss</a> which can be highly problematic in a child’s early language development years. Chronic ear drum perforations are treated by repairing the hole with surgery.</p><h4>Otitis media with effusion (OME)</h4><p>The Eustachian tube normally drains fluid from your ears to the back of your throat — otitis media with effusion occurs when this tube becomes clogged. While OME isn’t an ear infection, the two are often related — otitis media with effusion can develop when the fluid remains trapped behind the eardrum even after an ear infection has run its course. This fluid can remain in the ear for weeks, even months at a time.<br>Children often show minimal or no symptoms for OME. The only common sign is hearing difficulties, which can be difficult for a child to express — so watch out for any suspicious behaviour (turning up the TV, speaking louder, not being able to localise sounds, tugging on the ear, etc). A doctor may be able to see the fluid when looking at the eardrum, but that is not possible in all cases. OME isn’t necessarily associated with permanent hearing loss. However, if associated with frequent ear infections, more complications can occur. These complications include,</p><ul><li>Cysts in the middle ear</li><li>Eardrum scarring (tympanosclerosis)</li><li>Damage to the ear, causing hearing loss</li><li>Affected speech or language delay</li></ul><h4>Chronic otitis media with effusion (COME)</h4><p>This is when the fluid remains in the middle ear for a long time or repeatedly returns even when there’s no active infection. This is undesirable because when left untreated, the consequences could potentially include persistent hearing loss as well as an inability of the central auditory nervous system to reach its full potential.</p><h3>Signs &amp; Symptoms of an Ear Infection</h3><p>Since ear infections are so common in young children — and for many even before they begin to talk — it’s a good idea to familiarize yourself on the signs and symptoms to look out for:</p><ul><li>Fussy, irritable behaviour</li><li>Problems sleeping</li><li>Fever</li><li>Issues balancing</li><li>Lack of appetite</li><li>Fluid draining from the ear</li><li>Trouble hearing</li><li>Pulling at the ear(s)</li><li>Red outer ear</li></ul><p>These are often symptoms associated with upper respiratory infections such as a stuffy, runny nose or a cough. Children are prone to catching these kinds of infections when exposed to groups of kids — as in child care, school or the playground. They will first catch the upper respiratory infection which may then develop into otitis media. Other known risks consist of exposure to tobacco smoke, air pollution, and certain atmospheric conditions.</p><p>All that to say, if you child is frequently congested, it could be more than just a regular cold. It may be manifesting itself as an ear infection and is worth seeing your family doctor or pediatrician.</p><h3>The Long-term Impact of Ear Infections</h3><p>Those who develop any level of otitis media before the age of six months will almost always have more frequent ear infection later on in their developing years. Ear infections, although common, must be treated appropriately. Most people with middle ear infection or fluid will have some degree of temporary hearing loss. Conductive hearing loss is when the transmission of sound from the environment to the inner ear is impaired, typically from a blockage in the external auditory canal or middle ear — this can either be temporary or permanent. Either way, it will reduce the amount of language processing practice the child is benefitting from in those early developmental years. Other challenges may include:</p><h4>Delayed Language</h4><p>It’s important for children to hear consistent and clear speech sounds in order to develop strong language skills. Periods of hearing loss, even reduced hearing at an early age can have a major impact on a child’s language development. Their language development can plateau — they may begin mispronouncing words, which is an issue that could persist even after the child’s hearing has recovered.</p><h4>Learning Difficulties</h4><p>Hearing loss/reduction caused from an ear infection can make it harder for kids to listen and follow instructions, especially while in the classroom. Consistent ear infections at an early age can also impact the development of a child’s auditory pathway, making it hard for them to process what it is they’re hearing. This is known as an auditory processing deficit. Kids with this typically have trouble processing two or more instructions or pieces of information, and also have trouble understanding speech in noise. This makes it difficult for them to stay focused, and they can miss key instructions in the presence of background noise.</p><h4>Reading Issues</h4><p>Due to the potential negative impact on developing auditory processing that chronic otitis media can have, it is not surprising that associated skills can also be affected. Due to the inability to break up phonemes in words, a child who has had numerous ear infections can be at higher risk for reading difficulties, including <a href="https://www.gemmlearning.com/blog/dyslexia/9-surprising-clues-of-dyslexia-in-children/">dyslexia</a>.</p><h3>What to do?</h3><p>To be clear, not all ear infections will lead to these kinds of repercussions. As mentioned earlier, almost every child will face one (or multiple) ear infection at some point — but I do want to stress the importance of appropriately monitoring their hearing health. This simply means to take action when action is needed. Keep an eye (or an ear) out for any concerning behaviour, and ask your doctor about a hearing test. According to the <a href="https://www.shoebox.md/school-aged-hearing-screening/">iHear</a> program and the <a href="https://www.cdc.gov/ncbddd/hearingloss/documents/aaa_childhood-hearing-guidelines_2011.pdf">American Academy of Audiology</a>, children should be getting their hearing tested in preschool, kindergarten, grade 1, 3, 5 and either 7 or 9. A simple hearing test isn’t much to ask for, especially when it comes to the long term well-being of our children.</p><p>Written by: <a href="https://www.linkedin.com/in/olivia-allan-b82398137/">Olivia Allan</a></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=8b438904d49b" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Unilateral Hearing Loss Vs. Bilateral Hearing Loss]]></title>
            <link>https://medium.com/@SHOEBOX_Aud/unilateral-hearing-loss-vs-bilateral-hearing-loss-c200704b918c?source=rss-69d62a4d8850------2</link>
            <guid isPermaLink="false">https://medium.com/p/c200704b918c</guid>
            <category><![CDATA[healthcare]]></category>
            <category><![CDATA[health]]></category>
            <category><![CDATA[hearing-loss]]></category>
            <category><![CDATA[hearing]]></category>
            <dc:creator><![CDATA[SHOEBOX Audiometry]]></dc:creator>
            <pubDate>Wed, 21 Nov 2018 16:26:01 GMT</pubDate>
            <atom:updated>2018-11-21T16:26:01.955Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*6-caAP0PEYZE02gkHdFAgQ.png" /></figure><p>Have you ever wondered why some people don’t seem to be listening, or why others require the television to be just a little bit louder? Have you ever noticed a friend or family member who seems uncomfortable in noisy social settings, or a child who has trouble concentrating? The reason for these actions may surprise you.</p><p>Hearing loss is more common than you may think (6–8% of the global population suffers from disabling hearing loss) and can be a challenging obstacle to overcome. The truth of the matter is, many don’t even realize that their hearing ability is having an impact on their lives. And it will affect individuals differently, depending on their age, experiences, and even genetics.</p><p>Hearing loss can be categorized as unilateral or bilateral — meaning in one ear or in both. Furthermore, hearing levels can be different or similar between the ears — known as asymmetrical or symmetrical hearing. Unique in their own specific ways, all have the ability to have varying impacts from person to person.</p><h3>What is Unilateral Hearing Loss?</h3><p>How many times have you heard, “I can’t hear what you’re saying, come around to my good side”. Do people really have a good side and a bad side in terms of hearing? For some, the answer is a yes. When hearing is within normal limits in one ear but the other ear is affected, the term used to describe this is unilateral hearing loss, but can also be referred to as “one-sided hearing loss”.</p><p>Unilateral hearing loss can present as either a reduced ability or complete inability to hear out of one ear. Many who suffer from this type of hearing impairment have difficulty determining the direction of sound, and can struggle to separate background noise and speech.</p><h3>What Causes Unilateral Hearing Loss?</h3><p>There are a number of different factors including:</p><ul><li><em>Exposure to loud, impulsive sounds</em></li><li><em>Illness or medical conditions</em></li><li><em>Tumors or head injuries</em></li><li><em>Ototoxic medications</em></li><li><em>Congenital malformations</em></li></ul><h3>What is Bilateral Hearing Loss?</h3><p>Bilateral hearing loss, or, “double-sided hearing loss” means just that — a reduced ability to hear in not one, but both ears. The continuum of hearing loss covers a range of levels — from mild to profound to anacusis (which is complete lack of hearing ability). Double-sided hearing loss impairs both ears, albeit possibly at different levels. Most people have one ear that hears better than the other. When hearing impairment is present and the overall severity is the same in both ears, it is known as symmetrical bilateral hearing loss. When hearing loss levels exist in both ears but at varying degrees, this is referred to as asymmetrical bilateral hearing loss.</p><h3>What Causes Bilateral Hearing Loss?</h3><p>There are a number of possible contributing factors but some of the most common causes of bilateral hearing loss include:</p><ul><li><em>Advanced age (1 in 3 over the age of 65 has some hearing loss)</em></li><li><em>Exposure to loud noise</em></li><li><em>Ototoxic medications</em></li><li><em>Genetics</em></li><li><em>Head injuries</em></li><li><em>Severe illness or viral infection</em></li></ul><h3>Protect Your Hearing</h3><p>Although there isn’t very much that we can do about getting older, or our genetic makeup, we can certainly all be more cognizant when it comes to guarding against loud noise exposure. If you work in a constantly noisy environment, you are likely mandated by law to wear hearing protection. If you like listening to music through headphones or earbuds, try turning down the volume. And why not use earplugs when using loud tools or machinery like chainsaws, snow blowers, or lawnmowers around your house? But most importantly — get your hearing tested! With the same frequency that we have our eyes checked, or our cholesterol levels measured, we should have our hearing tested (read more about <a href="https://www.shoebox.md/blog/">hearing testing in primary care practices</a>). Changes can happen slowly, over time, and in ways that we barely recognize — until one day we are having a hard time following conversation and find ourselves retreating socially. Hearing loss is the most common disability in the world so if — and when — your hearing starts to change, know that you are not alone. Reach out. Get tested.</p><p>Written by: <a href="https://www.linkedin.com/in/trevor-griffith/">Trevor Griffith</a></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=c200704b918c" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Partnering with The Union and Vital Strategies to Include SHOEBOX Audiometry in Multi-drug…]]></title>
            <link>https://medium.com/@SHOEBOX_Aud/partnering-with-the-union-and-vital-strategies-to-include-shoebox-audiometry-in-multi-drug-11fcc8517056?source=rss-69d62a4d8850------2</link>
            <guid isPermaLink="false">https://medium.com/p/11fcc8517056</guid>
            <category><![CDATA[clinical-trials]]></category>
            <category><![CDATA[tuberculosis]]></category>
            <category><![CDATA[health]]></category>
            <category><![CDATA[clinical]]></category>
            <category><![CDATA[hearing]]></category>
            <dc:creator><![CDATA[SHOEBOX Audiometry]]></dc:creator>
            <pubDate>Fri, 23 Mar 2018 19:06:56 GMT</pubDate>
            <atom:updated>2018-03-23T19:08:07.377Z</atom:updated>
            <content:encoded><![CDATA[<h3>Partnering with The Union and Vital Strategies to Include SHOEBOX Audiometry in Multi-drug Resistant Tuberculosis Clinical Trials</h3><p>In honour of #WorldTBDay tomorrow — March 24th, you should check out how we’ve partnered with The Union and Vital Strategies to Include SHOEBOX Audiometry in Multi-drug Resistant Tuberculosis Clinical Trials…</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*rdhIRZZ7hlrau8g95a7Aaw.jpeg" /></figure><p>I’m on a short plane ride home reflecting on my last few days spent with The International Union Against Tuberculosis and Lung Disease (<a href="https://www.theunion.org/">The Union</a>) and its affiliate<a href="https://www.vitalstrategies.org/">Vital Strategies</a>. Together they have been working on a Phase III Clinical Trial to test simpler and shorter treatment regimes for patients suffering from multidrug-resistant tuberculosis (MDR-TB).</p><p>Tuberculosis (TB) is a disease caused by bacteria that affects the lungs. In 2014 just over 9.6 million people were newly diagnosed with TB, and there were 1.5 million TB-related deaths worldwide. It is highly infectious and those suffering from a compromised immune system are at a significantly increased risk of becoming symptomatic.</p><p>TB is curable and preventable but the bacteria that causes the disease can develop resistance to the drugs used to treat it. This happens for a number of reasons including the incorrect use of the drugs, or through ineffective formulations. In some countries, it is becoming increasingly difficult to treat multidrug-resistant TB. Also in 2014, there were an estimated 480,000 new cases of MDR-TB and it is estimated that this disease killed 190,000 people worldwide that same year.</p><p>STREAM is the clinical study being conducted by The Union and Vital Strategies in numerous countries including Mongolia, Ethiopia, and South Africa. They are working to evaluate simpler and shorter treatment regimes for patients with MDR-TB. That’s the good news. The bad news is that some of the other regimes are highly ototoxic meaning that there is a strong possibility of hearing loss as a side effect of being treated for the disease.</p><p>That’s why I was in New York meeting with this group. We are so proud to be part of this very important trial. Phase II STREAM sites have begun using <a href="https://www.shoebox.md/products">SHOEBOX Audiometry</a> — a clinically validated iPad audiometer that performs diagnostic threshold hearing testing — to test patients’ hearing levels. We are working to help equip all of the eligible Phase II sites with SHOEBOX audiometers to monitor this very important side effect. Patients have their hearing testing once admitted into this phase of the trial, and every month thereafter. If a significant deterioration in hearing levels is detected, a change in treatment is often prescribed.</p><p>The vast majority of these study patients will not have ever had a hearing test, and although they have other very serious health concerns, it is important to manage impairments that can be prevented. Often in low-resource countries, having hearing loss can be the factor that prevents an individual from finding and/or maintaining employment. This can be devastating not only for that individual but also for the family members that also rely on their income to live. The ability to communicate is one that is often taken for granted and only when it is compromised do we gain an understanding of how crucial it is to our livelihood.</p><p>Notably, the Union and its esteemed partners have been so pleased with the capabilities of SHOEBOX Audiometry that they have been recommending it to other groups currently running MDR-TB clinical trials. I speak for the entire Ottawa-based team when I say that we are thrilled at this development and hope to help make a significant impact in the important detection of hearing loss and its prevention worldwide.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=11fcc8517056" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[What Is Included in a Comprehensive Hearing Evaluation?]]></title>
            <link>https://medium.com/@SHOEBOX_Aud/what-is-included-in-a-comprehensive-hearing-evaluation-10e5d0b5ebcc?source=rss-69d62a4d8850------2</link>
            <guid isPermaLink="false">https://medium.com/p/10e5d0b5ebcc</guid>
            <category><![CDATA[speech]]></category>
            <category><![CDATA[hearing]]></category>
            <category><![CDATA[testing]]></category>
            <category><![CDATA[comprehension]]></category>
            <category><![CDATA[evaluation]]></category>
            <dc:creator><![CDATA[SHOEBOX Audiometry]]></dc:creator>
            <pubDate>Wed, 14 Mar 2018 15:36:26 GMT</pubDate>
            <atom:updated>2018-03-14T15:36:26.296Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*57uMJhdzTMgxdc3PbXZzpw.jpeg" /></figure><p>Hearing health professionals perform multiple tests as part of a comprehensive hearing evaluation. The methods used vary based on the age of the person, the environment, and the purpose of the test. Read on to familiarize yourself with what test might be performed at your next hearing appointment. You have one scheduled, right?</p><h3>Pure Tone Test</h3><p>The most common is <a href="https://www.asha.org/public/hearing/pure-tone-testing/">pure-tone testing</a>. Sounds are projected at different tones, intensities, and frequencies. The patient then indicates which sounds they are able to hear. This test can differentiate between <a href="https://www.shoebox.md/unilateral-hearing-loss-vs-bilateral-hearing-loss/">one-sided versus bilateral hearing loss</a>.</p><p>There are two transducer modes of pure tone testing: air conduction and bone conduction. During an air conduction test the sounds are delivered through a set of head or earphones. Bone conduction is a little different.</p><h4>Bone Conduction Test</h4><p>This test uses a device called a bone oscillator. It is a transducer that looks like a small square box attached to the end of a metal headband. The headband is placed over the head with the square box resting on top of the mastoid bone behind the ear.</p><p>Again, the test is performed by projecting sound at different tones and frequencies. But this time the sounds will be ‘heard’ through the vibration of the mastoid bone in the skull. By by-passing the outer and middle ear, the test is able to confirm that a hearing impairment is not the result of a conductive blockage. Rather, a sensorineural, or nerve-related, hearing loss is present.</p><p>The results of a pure tone test are recorded on an audiogram. This is a graphical representation of how loud sounds must be before the patient is able to perceive them.</p><h3>Speech Test</h3><p>Like pure tone testing, there are various types of <a href="https://www.asha.org/public/hearing/speech-testing/">speech tests</a>that can be performed as part of a comprehensive hearing evaluation. One can check how loud speech needs to be for it to be detected. Another checks for how well the words can be heard and distinguished at a conversational level.</p><h4>Speech Reception Threshold (SRT) Test</h4><p>During this test, the patient is asked to repeat a list of known words presented at different volumes. The test determines the lowest volume at which speech can be heard and recognized. In conjunction with pure tone testing, it validates the patient’s hearing threshold.</p><h4>Speech Discrimination Test</h4><p>Hearing loss and speech discrimination often go hand in hand. During this test, the patient listens and then repeats a list of one-syllable words. Results are recorded as a percentage of the number of words correctly repeated back. The test helps to determine an individual’s level of candidacy for hearing amplification. As such, it is often used in the selection and fitting of hearing aids.</p><h3>Tests of the Middle Ear</h3><p>The middle ear is integral to hearing. Comprised of 3 tiny bones, membranes, and tubes, it transmits sound from the outer to the inner ear. The three <a href="https://www.asha.org/public/hearing/Tests-of-the-Middle-Ear/">tests used to evaluate the function of the middle ear</a>are:</p><ul><li>Tympanometry (evaluation of the eardrum)</li><li>Acoustic reflex threshold (ART)</li><li>Static acoustic impedance</li></ul><h4>Tympanometry</h4><p>Using a tympanometer, variations in air pressure are presented to the middle ear. This test helps to determine eardrum mobility, resting middle ear pressure, eardrum compliance, and cumulatively how effective the eardrum is at transmitting sound to the middle ear cavity and therefore the inner ear as well.</p><h4>Acoustic reflex threshold (ART)</h4><p>Responding to relatively high-intensity sound, the connective tissue of the middle ear will contract involuntarily. ART measures the sound pressure level that will trigger this reflex and compares it to norms for individuals with hearing within normal limits.</p><h4>Static acoustic impedance</h4><p>This is a test to measure air pressure flow in the ear canal. It is used to identify blockages or even a hole in the eardrum. It can also detect if there is fluid behind the eardrum.</p><h3>Auditory Brainstem Response (ABR) Testing</h3><p><a href="https://emedicine.medscape.com/article/836277-overview?pa=v%2BVzXLECLFgidN2WehP8IrZajeOLELZUMvT%2FMhL7q2bB8Oc6PYMqCO1y01cP1amttEQOTx6xUoiWmdhs3ICrFnBa6qMPn9v9%2B17kWmU%2BiQA%3D">ABR</a> is a neurologic test of the function of the auditory system through to the brainstem. During a comprehensive hearing evaluation, it is used to measure the hearing nerve’s response to sound. The patient must lie perfectly still. In very young children the test can be performed while they sleep. Three to four electrodes are applied to the patient’s head and in front of their ears. Using a computer, sound is delivered through earphones. The electrodes then measure how the hearing nerve responds to the sound stimuli.</p><h3>Otoacoustic Emissions Testing (OAE)</h3><p>This is a <a href="https://www.audiologyonline.com/articles/otoacoustic-emissions-beyond-newborn-hearing-838">test</a> of the inner ear or cochlea. It measures emissions, which are sounds given off by the inner ear in response to sound. When the hair cells of the inner ear vibrate, they produce a quiet response that echoes back into the middle ear. This sound — or OEA — is a measure to help determine if hearing is within normal limits or not.</p><p>OAE tests can also help determine if there is a blockage in the outer or inner ear. If there is a blockage, no sound will get through meaning that no vibration or sound will be measurable by the OAE probe.</p><p>During a comprehensive hearing evaluation, your hearing health professional will employ one or several of the tests described above. Again, each patient, environment, and reason for the test will determine what combination he or she may perform. Furthermore, there is a variety of equipment that can be used. Having your hearing fully evaluated is important. Did you know that hearing loss is the world’s leading disability? Don’t put it off. Make an appointment today.</p><p>~ <a href="https://www.shoebox.md/blog/?utm_source=medium&amp;utm_medium=blog%20post&amp;utm_campaign=What%20Is%20Included%20in%20a%20Comprehensive%20Hearing%20Evaluation%3F%20-%20medium">SHOEBOX Audiometry Blog</a></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=10e5d0b5ebcc" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Tinnitus — What You Need To Know]]></title>
            <link>https://medium.com/@SHOEBOX_Aud/tinnitus-what-you-need-to-know-80bf7cee37c?source=rss-69d62a4d8850------2</link>
            <guid isPermaLink="false">https://medium.com/p/80bf7cee37c</guid>
            <category><![CDATA[hearing-loss]]></category>
            <category><![CDATA[health]]></category>
            <category><![CDATA[tinnitus]]></category>
            <category><![CDATA[hearing]]></category>
            <category><![CDATA[audio]]></category>
            <dc:creator><![CDATA[SHOEBOX Audiometry]]></dc:creator>
            <pubDate>Wed, 07 Feb 2018 16:21:09 GMT</pubDate>
            <atom:updated>2018-02-07T16:21:09.079Z</atom:updated>
            <content:encoded><![CDATA[<p>The ear is a complicated piece of anatomy. Simply put, sound waves pass through the ear canal causing the eardrum to vibrate which in turn moves the small bones of the middle ear. The movement of the last small bone taps on the cochlea — the spiralled tube known as the inner ear — which is filled with liquid and microscopic cells including stereocilia that have hair-like endings. When sound reaches the cochlea, vibrations move the hairs creating a nerve signal understood by the brain as sound. When everything is working well, messages are received loud and clear. But with so many moving parts there are many ways and degrees to which we can do damage to our hearing. This article explores tinnitus, one of the possible side effects of not properly protecting our hearing. According to the U.S Centers for Disease Control, approximately 15% of the general public, or 50 million Americans, experience some form of tinnitus in their lifetime.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1000/1*wNqZsqkgqYIiJ1MQbgG_-g.jpeg" /></figure><h3>What is tinnitus?</h3><p>Tinnitus is the “perception” of sound. It can occur secondary to different situations and depending on the type, can originate in different places within the auditory system. It often presents as a persistent ringing or buzzing in the ear, but those suffering from tinnitus can experience it quite differently. Some describe the sound in their ear as roaring, rushing, hissing, chirping, beeping, buzzing, whistling, or clicking. Tinnitus can be a temporary (acute) condition or an ongoing (chronic) health ailment. The sound may be high-pitch, low-pitch, or even multi-toned. It might be barely noticeable, but it could also be incredibly loud. Either way, it is a very unpleasant, disturbing feeling.</p><h3>What causes tinnitus?</h3><p><a href="https://www.ata.org/understanding-facts/causes">Tinnitus</a> in itself is not a disease, but it is a condition, and one that could be a symptom of another underlying health issue. It can be the result of many things, but the most common cause of tinnitus is damage to the tiny sensory hair cells in the cochlea. This can be the result of the normal aging process, but more commonly it is also caused by prolonged exposure to excessively loud noise, and in conjunction with noise-induced hearing loss (NIHL).</p><h4>Noise Induced Hearing Loss (NIHL)</h4><p>NIHL results from exposure to loud noise either in one single traumatic experience, or over a cumulative period of time. Loud noise is qualified as anything over 85 dBA — for example farm machinery, construction tools, gunfire, amplified music, drilling or explosive devices, and much more. The louder and longer you are exposed to this level of noise, the higher your risk of developing tinnitus. It may not present as a symptom right away and it may be temporary at first, but for those who spend long periods of time exposed to these kinds of noise levels, taking adequate precautions by wearing hearing protection is highly recommended.</p><h4>Trauma</h4><p>Tinnitus can also be a symptom of head or neck trauma. Patients who suffer a severe injury to the head or neck can suffer from nerve, muscle, and blood flow issues that could all result in the perception of tinnitus. It is also common to report having tinnitus after suffering a traumatic brain injury. More specifically, it is possible to damage the brain’s auditory processing areas and pathways following concussive shock and this in turn, can generate tinnitus symptoms.</p><h4>Obstructions</h4><p>Outer and middle ear obstructions can also cause tinnitus symptoms to surface. Blockages caused by excessive ear wax, dirt, foreign objects, or head congestion can cause pressure to build up in the ear or create a closed compartment which naturally amplifies sound. This is also the reason why many of us notice our tinnitus at night when we put our heads on a pillow. When closing off the ear canal by lying on a pillow, we are creating a closed cavity which will amplify the natural biological sounds that we all experience regularly but don’t generally perceive. In cases where the ear canal or middle ear is obstructed, tinnitus symptoms generally subside once the blockage is removed.</p><h4>Ototoxic Medications</h4><p>Tinnitus is also a potential side-effect of some prescription medications. Ototoxicity is a condition in which damage to the inner ear or auditory system is caused by a drug or chemical agent. Ototoxicity can include hearing loss, but also tinnitus and disruptions to the balance system which is also part of the inner ear. Tinnitus secondary to ototoxicity has the potential to either cause acute, short-lived symptoms or, in some cases, permanent effects. Drugs known to be ototoxic for some individuals include some antibiotics, non-steroidal anti-inflammatory drugs, quinine-based medications, certain cancer medications, water pills, and diuretics.</p><h3>What to do</h3><p>Loud or prolonged exposure to dangerous noise will always pose a threat to our hearing health. We can’t always control the sounds around us, but we can take precautions to help protect our ears. Be prepared. If you know you will be exposed to loud noise — whether at work or at play — wear hearing protection like ear plugs. Educate yourself on noise. Know how long it is safe to be exposed to various decibel levels. For example the average rock concert, loud symphony, or sporting event can reach 129 dB. Most mobile devices can go as loud as 120 dB. It is only safe to listen at this level for a maximum of 10 minutes. That same mobile device can also use a pretty decent sound meter in the form of an application. Use it to determine how loud your environment is. If you have tinnitus, it is import to know your triggers. For some sufferers red wine, caffeine, and loud noise can make symptoms worse. And turn down the volume. Sometimes you simply need to give your ears some rest.</p><p>Finally, might it be time to consider having your hearing tested? Most of us are careful to never miss our annual physical, but when was the last time you had your hearing checked? For many, it was probably as a child. This may be because testing is typically performed by professionals in specialized clinics and it may seem inconvenient, or wait times could be lengthy. But new advances in hearing testing technology are making it possible for more healthcare providers to perform diagnostic hearing testing right in the doctor’s office or even at your place of work.</p><p><a href="https://www.shoebox.md/?utm_source=Medium&amp;utm_medium=social&amp;utm_campaign=Tinnitus%20%E2%80%93%20What%20You%20Need%20To%20Know%20-%20Medium">SHOEBOX Audiometry</a> is an automated, interactive audiometer that functions almost like playing a game. Ask your doctor for a hearing test, and about SHOEBOX Audiometry today.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=80bf7cee37c" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Eliminate the Most Common
Challenges in Audiometric
Testing
A Case for Tablet Audiometry in…]]></title>
            <link>https://medium.com/@SHOEBOX_Aud/eliminate-the-most-common-challenges-in-audiometric-testing-a-case-for-tablet-audiometry-in-ff5933a9697d?source=rss-69d62a4d8850------2</link>
            <guid isPermaLink="false">https://medium.com/p/ff5933a9697d</guid>
            <category><![CDATA[audio]]></category>
            <category><![CDATA[hearing]]></category>
            <category><![CDATA[healthcare]]></category>
            <category><![CDATA[occupational-safety]]></category>
            <category><![CDATA[audiology]]></category>
            <dc:creator><![CDATA[SHOEBOX Audiometry]]></dc:creator>
            <pubDate>Mon, 29 Jan 2018 20:21:56 GMT</pubDate>
            <atom:updated>2018-01-29T20:21:56.635Z</atom:updated>
            <content:encoded><![CDATA[<h3>Eliminate the Most Common<br>Challenges in Audiometric<br>Testing<br><strong>A Case for Tablet Audiometry in<br>Occupational Hearing Conservation</strong></h3><p><strong>AUDIOMETRIC TESTING</strong></p><p>Audiometric testing is simply put, a “hearing test”. It is performed using a highly precise medical device called an audiometer which is used to evaluate an individual’s ability to hear sounds at varying tones and intensities.</p><p><strong>SETTING A BASELINE</strong></p><p>As part of a company’s occupational hearing conservation program, audiometric testing typically begins with a baseline audiogram. A baseline is not intended to identify whether or not an employee has any hearing loss, but rather, to determine their level of hearing at the start of employment.</p><p>Once a baseline has been established, the employee must be re-tested on an annual basis to determine if any shift in hearing levels as compared to that initial baseline have occurred. If a shift is detected, particularly as a result of workplace conditions, there are prescribed “next steps” that must be followed to help protect the hearing health of the employee, and the safety of their colleagues</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*AWVZ5hiqMeXDFyWVFhfUGQ.jpeg" /></figure><p><strong>TYPICAL CHALLENGES IN AUDIOMETRIC TESTING</strong></p><p>For those who run hearing conservation programs in-house, are service providers who perform audiometric testing on behalf of clients, or are considering adding audiometric testing to the services currently offered, you are likely faced with one or more of these common challenges:</p><p>SCHEDULING<br>Whether you service 10’s or 100’s of employees or clients, scheduling can pose a logistical nightmare — especially when attempting to schedule everyone’s annual exam over a short period of time once per year. It is not uncommon in large organizations for those who manage the hearing conservation program to spend in excess of 2 full weeks on scheduling alone. Admittedly, not a highly efficient use of time for skilled professionals.</p><p>Also consider pre-employment screenings. We know how important it is for that baseline audiogram to be performed at — or very near — to a new hire’s start date. But what happens when your annual round of testing isn’t slated for another 10 months and when your new hire’s first baseline is performed it indicates some hearing loss? Did that employee join your firm with that level of hearing, or was the loss brought on by noise at work? This can be difficult to determine if testing is regimented to only once per year.</p><p>And, after weeks of planning and booking the calendars of every employee — often in organizations that operate 24-hour shifts — inevitably there will be a group of people who will miss their test and need to be rescheduled. Such is life. But now what? More scheduling, paid time off work to visit an off-site clinic, transportation costs to and from appointments, clinic fees, and more.</p><p>COST<br>It will come as no surprise to anyone reading this paper that traditional audiometric equipment is expensive to purchase, expensive to maintain and calibrate, and requires a lot of real estate.</p><p>If you are a service provider then you most likely maintain one or more mobile clinics — trucks outfitted with 4–6 sound booths, audiometers, and a desk-top computer that serves as a central control for the testing stations. These trucks are driven around the country and brought on-site to client locations where employees sit in the booths to take their hearing tests.</p><p>The benefit of a traditional mobile clinic is that multiple employees can be tested at the same time allowing for a higher volume of throughput. And of course, the truck offers a quiet, controlled environment to administer the tests. But the cost of gas, insurance, maintenance, calibration of the booths and testing equipment, not to mention the full- time staff member required to drive and operate the clinic is high and continually climbing.</p><p>Let’s come back to scheduling for a moment. What happens when employees miss their scheduled test? Is the mobile clinic expected to be driven back to the client site to test only a handful of people? What if your client has a large main facility and a handful of small satellite locations? It is not cost efficient for the mobile clinic to drive to several locations where only a small number of tests may be required, nor is it reasonable to expect the client to have employees travel to the main facility for their annual tests.</p><p>OUTDATED EQUIPMENT<br>For both service providers and in-house programs, traditional audiometers and sound booths have remained relatively unchanged in more than 30 years. Equipment is bulky, only minimally portable, and manually operated, which requires that testing only be performed by technicians who have been certified by the Council for Accreditation in Occupational Hearing Conservation (CAOHC).</p><p>Although there are options to move and store the data produced by these devices in a digital format, the process is rarely seamless. And see the point above — cost. This is usually a for-fee service offered by another service provider. For those who opt not to pay for this type of service, there will be a great deal of paperwork. Records that needs to be filed and archived for long periods of time.</p><p>To summarize, audiometric testing as part of an occupational hearing conservation program — whether done in house or provided as a service — presents logistical challenges, is expensive, and current processes and workflows are fairly antiquated.</p><p><strong>THE CASE FOR TABLET AUDIOMETRY — INTRODUCING SHOEBOX</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/560/1*LcP6hM_Wgo-GynS-Q4sukA.png" /></figure><p><a href="https://www.shoebox.md/?utm_source=blog&amp;utm_medium=medium&amp;utm_campaign=Eliminate%20the%20Most%20Common%20Challenges%20in%20Audiometric%20Testing%20A%20Case%20for%20Tablet%20Audiometry%20in%20Occupational%20Hearing%20Conservation%20-%20blog">SHOEBOX Audiometry</a> is the first clinically validated iPad audiometer, and a total solution for occupational hearing conservation programs. It is comprised of two main components. First is the testing equipment; an iPad-based audiometer, software, and a set of calibrated high-attenuating transducers. Second is a web-based data management system.</p><p>TESTING EQUIPMENT<br>The SHOEBOX audiometer is equipped with our smart background noise monitoring functionality, making it is optimized for use outside of a sound booth. The iPad’s built-in microphone is controlled by the software and actively monitored to ensure background noise levels in the room are appropriate when testing is performed. SHOEBOX also comes pre-installed with OSHA and ANSI test parameters for volume limits, frequencies, and Maximum Permissible Ambient Noise Levels (MPANLs). Based on the standard you select for your testing, the system will notify both you and the employee if the MPANL has been exceeded, and prompts them to “pause” until levels have returned to an acceptable level. All of this is designed to help you meet your OSHA compliance requirements even if testing is performed outside of a sound booth.</p><p>SHOEBOX Audiometry also offers the option to perform testing in either automated or manual modes. In <strong>automated</strong> mode, the system uses a modified Hughson-Westlake protocol (step-up/step-down methodology). After instruction (with an option to watch a short instructional video), the employee self-tests by completing a simple drag-and- drop sorting game based on whether or not they hear sounds presented at various frequencies and intensities. The output is a threshold seeking, clinically valid<br>audiogram. Even the results interpretation is automated which means that almost anyone can administer a valid hearing testing. And that administrator does not need to be CAOHC certified.</p><p>SHOEBOX in <strong>manual</strong> mode offers a full range of clinical audiometric capabilities and is often the system of choice for audiologists, physicians, and CAOHC-certified hearing conservationists. It offers advanced functionality including Extended High Frequency (EHF) testing, bone conduction testing, speech discrimination testing, and more. To use SHOEBOX Audiometry in manual mode, CAOHC certification is required as all results interpretation is performed manually.</p><p>DATA MANAGEMENT<br>SHOEBOX Data Management — the second component of the system — is a simple, easy-to-use, web-based portal designed for moving data off of the iPad and storing, accessing, and managing employee data and test results from any web browser. Data syncs automatically whenever you are in a connected environment. It is even possible to upload historical information and audiometric data that was captured using a different hearing testing system. We offer templates to facilitate this import or we can perform the import for you as a service.</p><p>SHOEBOX Data management is also used to easily set baselines and automate the process of detecting any shifts against that baseline. You can even group your employees into “teams” for group-based reports. For service providers, this makes it easy to organize data by client and for in-house programs, to organize data by locations, test dates, or departments for example.</p><p>It is also used to generate both individual and group reports for OSHA compliance purposes. Our out-of-the-box reports include:</p><ul><li><em>Individual Summary Report:</em> This is a complete summary of an individual<br>employee’s hearing test results. It provides not only their most recent<br>audiogram, but also a summary of any shifts in their hearing levels. It also<br>provides space for both the employee and test administrator to date and sign<br>the reports.</li><li><em>Roster Report:</em> This is a high-level overview of test results for any given group within a specific date range. For in-house hearing conservation programs, this report can be useful for identifying trends in your workplace environment. For example, if you see shifts against a baseline for a group of people who work in a common area, it could be an indication that additional measures need to be taken to protect employees in that location, or on that shift. For service providers, this report will provide your clients a summary of all the employees you tested on a specific day.</li><li><em>Shift Report:</em> Similar to the roster report that it provides results for multiple people on one page, a Shift Report will summarize results for only those employees tested whose results indicate a shift in their level of hearing against their baseline audiogram.<br>This report is essential for identifying everyone who needs to be referred out to an audiologist for subsequent testing.</li></ul><p>Finally, for those who already use an EMR or other data management system, SHOEBOX Data Management can be used to export data as a .csv file or in PDF format that can then be saved elsewhere.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*IHiARgjphU_wz_FnqED1pA.jpeg" /></figure><p><strong>ELIMINATE THE MOST COMMON CHALLENGES</strong></p><p>Now, let’s contemplate how a system like SHOEBOX Audiometry could be used to eliminate the most common challenges that hearing conservationists face; scheduling, costs, and outdated equipment</p><p>TEST ANY TIME<br>If you manage your program in-house, tablet audiometry can easily enable testing on a regular basis — such as daily or weekly — eliminating the need to schedule everyone over only a few days. You might opt to test entire departments or shifts over the course of a month, then move on to the next one. If your business operates on 24-hour shifts, you can perform testing overnight, ensuring minimal downtime for employees and making testing that much more convenient for them.</p><p>You might even use it as a backup system to your service provider. If you still opt to have them come on site annually to perform testing, you could manage the employees who miss their test yourself. This will help you keep your program on track and eliminate the need to attempt to book testing at an outside clinic.</p><p>And all new employees can have their baseline audiogram performed at their time of hire, not when the next round of annual testing was scheduled. This will let you know for certain, from day one, what that employees baseline results are so that there can be no question if or when a shift occurs.</p><p>AUGEMENT EXPENSIVE MOBILE CLINICS<br>We may never completely replace the mobile clinics. As mentioned, they provide a good controlled environment to test multiple people simultaneously. But there are several valid considerations for augmenting your mobile clinic with tablet audiometry.</p><p>First and foremost, it lets you eliminate the need for a sound booth, which can cost upwards of $15,000. Even if you still want to outfit a mobile clinic with multiple testing stations, you can do so without this added expense. All you need to do is keep that space reasonably quiet and SHOEBOX will monitor to ensure testing remains in accordance to the OSHA or ANSI MPANL that you selected.</p><p>And if your mobile clinic is already outfitted with multiple sound booths, it is still very expensive to bring the truck back to a client site — or even to a small satellite location — to test small numbers of employees who may have missed the originally scheduled test data. In this case, it would be more efficient for you and for your customer to “parachute” into these locations with a single test administrator hand carrying one or more iPads. Remember, SHOEBOX offers automated testing functionality that enables almost anyone to administer a valid hearing test. So, while your CAOHC-certified hearing conservationist(s) drive the truck on to your next client’s location, you can fly a non-CAOCH certified technician in to help administer the rescheduled tests.</p><p>Another advantage of the highly portable iPad is that it means you can set up testing in locations very near to where employees work, minimizing the amount of time they are away from their work station for the hearing test. It would not be uncommon in a large facility for the parking lot that could accommodate a mobile clinic to be a mile or more away from where employees spend their days. One of the key benefits we hear over and over about SHOEBOX Audiometry is that it lets you bring testing right to where the people are rather than requiring them to travel to the test.</p><p>IMPROVE EFFICIENCY AND WORKFLOWS WITH MODERN, MOBILE TECHNOLOGY<br>Finally, there is no denying that tablet technology is state-of-the-art. The advantage of a software-based system is that it is continually being developed. You won’t spend money on a system that will remain unchanged for 10 or more years, or until it is time to purchase your next audiometer. Rather, it will continue to evolve to meet the needs of your program today and years into the future.</p><p>These systems are digital by design, eliminating the need for paper all together. Our web-based data management platform is unmatched in its ability to administer employee demographic data and test results, offering advanced filtering and reporting capabilities to help you adhere to OSHA compliance requirements. It enables an environment where you can organize and view information in meaningful ways, automate processes like baseline setting and shift detections, and generate the reports you need for your specific program.</p><p>And the automated capabilities offered by SHOEBOX Audiometry — from the test itself, to results analysis, and even baseline setting and shift detection — is changing the nature of audiometric testing. Now, it is possible for almost anyone to administer an audiometric test in any reasonably quiet location.</p><p><strong>CONCLUSION</strong></p><p>To summarize, SHOEBOX Audiometry is a complete system for audiometric testing as part of an occupational hearing conservation program. The iPad-based audiometer is ultra-lightweight and portable making it easy to move it between locations and conduct testing anytime and anywhere it’s needed. This is especially useful as part of new-hire onboarding, when employees need to have an annual test rescheduled, and even for those who are considering bringing their entire program in house. It is optimized and validated for use outside of a sound booth making it possible to conduct testing in any reasonably quiet location. Its automated functionality means that almost anyone — including non-CAOHC certified technicians can administer a diagnostic hearing test. And it offers OSHA and ANSI pre-set configurations to help you meet your specific compliance reporting requirements.</p><p>If you would like to learn more about how to use <a href="https://www.shoebox.md/?utm_source=blog&amp;utm_medium=medium&amp;utm_campaign=Eliminate%20the%20Most%20Common%20Challenges%20in%20Audiometric%20Testing%20A%20Case%20for%20Tablet%20Audiometry%20in%20Occupational%20Hearing%20Conservation%20-%20blog">SHOEBOX Audiometry</a> in your in-house hearing conservation program or in the services you provide, contact us at:</p><p><a href="/service/mailto:info@shoebox.md">info@shoebox.md</a><br><a href="https://www.shoebox.md/?utm_source=blog&amp;utm_medium=medium&amp;utm_campaign=Eliminate%20the%20Most%20Common%20Challenges%20in%20Audiometric%20Testing%20A%20Case%20for%20Tablet%20Audiometry%20in%20Occupational%20Hearing%20Conservation%20-%20blog">www.shoebox.md</a><br>877–349–9934</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=ff5933a9697d" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>