<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Alisha Rebecca on Medium]]></title>
        <description><![CDATA[Stories by Alisha Rebecca on Medium]]></description>
        <link>https://medium.com/@alisharebecca.zac?source=rss-755118a8b142------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/0*l-zTBGBI3_5XDey0</url>
            <title>Stories by Alisha Rebecca on Medium</title>
            <link>https://medium.com/@alisharebecca.zac?source=rss-755118a8b142------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Sat, 21 Nov 2026 17:46:02 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@alisharebecca.zac/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Energy Storage: Rethinking How We Cool Data Centres]]></title>
            <link>https://medium.com/@alisharebecca.zac/energy-storage-rethinking-how-we-cool-data-centres-1fe4b816eb65?source=rss-755118a8b142------2</link>
            <guid isPermaLink="false">https://medium.com/p/1fe4b816eb65</guid>
            <category><![CDATA[ai-data-center]]></category>
            <category><![CDATA[cooling-system]]></category>
            <category><![CDATA[energy-storage]]></category>
            <dc:creator><![CDATA[Alisha Rebecca]]></dc:creator>
            <pubDate>Fri, 23 Oct 2026 05:07:27 GMT</pubDate>
            <atom:updated>2026-10-23T05:07:27.611Z</atom:updated>
            <content:encoded><![CDATA[<p>How often do we consider what our electricity gets used for? Electricity supply and demand in a given region is a surprisingly delicate balance to strike. As our use of renewable resources and overall electrical consumption rise, so too does our need for effective methods of energy management.</p><p>AI data centres are the perfect example. Every algorithm response is fuelled by servers that require electricity and subsequently produce heat. This heat waste must be continuously dissipated with more electricity and occasionally, freshwater. When residing in a country where cooling is both necessary year-round and freshwater is a limited resource, we need to find other alternatives to manage our datacentre cooling.</p><p>Energy storage, while often thought of as simply saving electricity for a later time, can be applied to the dissipation of heat and used in conjunction with clever building design to both save energy and reduce a facility’s environmental impact.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*--FHbVDhHesWpRczh1JMoA.png" /><figcaption><em>Figure 1. Interior of an AI data centre. Source: Lawrence Berkeley National Laboratory (2025)</em></figcaption></figure><h3><strong>How Do Data Centres Keep Themselves Cool?</strong></h3><p>Data centres consist of servers that store and process information. Almost all of the electricity used by data centres is converted to waste heat, which must be managed in order to prevent overheating of servers and equipment. As datacentres become larger and more powerful by the day, so does their issue of waste heat dissipation.</p><p>No matter what method of cooling is used, there will be a cost-benefit analysis to evaluate. Factors such as installation cost, electricity consumption, water usage, and environmental impact all play a role in determining the most viable method for a given location. The four main methods of data centre cooling are traditional air conditioning, evaporative cooling, direct-to-chip liquid cooling, and immersion cooling. [1]</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*jpoM24A60t3V5GJ9GEidOQ.png" /><figcaption><em>Figure 2. Cooling infrastructure used to remove heat generated by data-centre servers. Source: Green Mountain, “Cooling” (n.d.)</em></figcaption></figure><h4>Air Cooling</h4><p>Most traditional data centres make use of Computer Room Air Conditioning (CRAC) units, which use fans to circulate air throughout the data centre. The air absorbs the waste heat generated by servers and is then cooled by the CRAC unit before being recirculated.</p><p>However, as data centres become more compact and dense, there is less air to cool, and less space to cool it with. Air is also a poor conductor of heat, so a lot of electricity may be needed for large-scale fans and refrigeration units.</p><p>Trade-off: Easy to implement, but not ideal for high-density server farms.</p><h4>Evaporative Cooling</h4><p>Evaporative Cooling uses the heat absorbed by water during the phase-change from liquid to gas to cool air or water.</p><p>Evaporative cooling is another well-established cooling technique that relies on less electricity than mechanical refrigeration. However, as mentioned above, water must be replenished after it has evaporated, which can be both costly and environmentally taxing. [1, 2] If an evaporative cooling system is used for an industrial facility, the system would consume large amounts of water over the course of its use, depending on the design and climate of the region.</p><p>Trade-off: Evaporative cooling uses less electricity, but more freshwater than other methods.</p><h4>Direct-to-Chip Liquid Cooled Systems</h4><p>Rather than cooling the air inside the server room, direct-to-chip liquid cooling uses an external reservoir of liquid that is pumped through cold plates attached to microprocessors like CPUs and GPUs.</p><p>As liquid is a much better conductor of heat than air, this form of direct cooling is especially useful for modern high-performance computers. Direct-to-chip liquid cooling can reduce the need for large-scale air cooling systems, as well as the consumption of freshwater in the case of a closed liquid system.</p><p>However, direct-to-chip cooling requires additional infrastructure and plumbing to pump and monitor the liquid. The initial investment is much higher than conventional air cooling systems. [1]</p><p>Trade-off: Ideal for high-performance computing, but requires more infrastructure.</p><h4>Immersion Cooling</h4><p>Immersion cooling works similarly to direct-to-chip cooling, but consists of submerging servers and processors in an electrified liquid dielectric fluid. The fluid conducts heat away from the servers and is then cooled via a separate mechanism.</p><p>Due to the nature of immersion cooling, there is no need for mechanical fans or large-scale air conditioning infrastructure. However, there is a higher initial investment in the tanks and associated equipment required for the system, and special precautions must be taken to ensure proper maintenance and prevent electrical hazards. [1]</p><p>Trade-off: An innovative way to tackle high-density cooling, but also more involved and complex than other methods.</p><p>These comparisons bring up a very pertinent point: when it comes to cooling systems, the method that uses the least electricity may not always be the most water-efficient or cost-effective.</p><h3>So Where Does Energy Storage Come In?</h3><p>Cooling doesn’t always have to coincide with the production of electricity. Thermal storage allows for the production of cooling to be separated from the point at which it is needed, which in turn allows for better energy management.</p><p>Thermal storage comes in different forms, the simplest examples of which are chilled-water and ice storage. Chillers use excess electricity to chill a large volume of water, which is then stored in a tank for later use. The chilled water can be circulated to a cooling system, where it can absorb waste heat from servers.</p><p>For ice storage, water is converted to ice at a time when excess electricity would otherwise go to waste. The ice is then used to cool servers, reducing the load on mechanical refrigeration units.</p><p>In both examples, electricity is still needed in order to produce cooling, but the timing at which the electricity is consumed can be manipulated to help reduce overall consumption.</p><p>Thermal storage differs from a conventional battery in that it doesn’t store electricity, but rather stores chilled water or ice for later use in a cooling system.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*5TGg0EzZ3pV_SSrGku4uDA.png" /><figcaption><em>Figure 3. A concrete thermal battery designed to store thermal energy for later use. Source: TechRadar Pro (2026).</em></figcaption></figure><h3>Concrete Thermal Batteries</h3><p>A prototype battery described by TechRadar makes use of engineered concrete and thermosiphons to store heat energy. The prototype battery was able to store up to 150 kWh of energy with a temperature gradient of up to 500°C, and had an efficiency of over 70%. [4]</p><p>Note that this is a high-temperature storage battery, and is unrelated to the topic of data centre cooling. However, it is worth mentioning as it highlights the versatility and potential of thermal storage.</p><p>Concrete thermal batteries work on a similar principle to thermal batteries, but operate at a much higher temperature range. This range of temperatures is useful for industrial processes that require the storage of heat energy.</p><p>For conventional data centres, the question of which kind of thermal battery would be useful depends on the temperature at which the servers are cooled and at what point during the day the servers are in operation.</p><h3>Why Electrical Storage Still Matters</h3><p>Thermal storage batteries are only one part of the solution. Electrical storage (or batteries) provide backup power, respond rapidly to fluctuations in demand, and can reduce a data centre’s peak load.</p><p>Large-scale battery storage is useful at both data centres and the grid level.</p><p>In the UAE, the Hatta Pumped Storage Hydro project is set to reduce the strain on the grid by using excess energy to pump water to a higher elevation and releasing it to produce electricity when needed. The 250 MW, 1,500 MWh pumped-storage hydropower project will allow the country to manage its electricity consumption more efficiently. [5]</p><p>Hatta is not directly related to data centre cooling, but it serves to highlight the importance of electrical storage at the grid level, where it can manage consumption more efficiently.</p><p>Batteries and pumped-storage hydropower are excellent long-term storage solutions that can manage excess electricity consumption. Thermal batteries can be useful for medium-term storage, and directly reducing the peak-time electricity consumption of data centres. Both energy storage technologies can provide valuable backup power for data centres, but batteries have a much faster response time.</p><h3>Why Can’t We Just Use Saltwater?</h3><p>Freshwater is a valuable resource, but if we are looking to reduce our consumption, what better place to start than the most plentiful source of water, seawater?</p><p>Unfortunately, most conventional evaporative cooling facilities rely almost exclusively on freshwater. If seawater were to be used, the resulting salts and minerals would build up in the system, causing excessive deposits on surfaces and within vessels. Seawater contains much higher concentrations of dissolved minerals than freshwater, and using it in an evaporative cooling facility would lead to much faster scaling and corrosion than if freshwater were to be used. [6]</p><p>Does that mean that we cannot use seawater for evaporative cooling? Not necessarily. There are several methods worth investigating.</p><h3>How Can Saltwater Be Used for Cooling?</h3><p>There are four main ways in which saltwater can be used for cooling. One method isn’t entirely dissimilar from evaporative cooling, but the other three all involve some form of separation from or treatment of saltwater to prevent scaling.</p><ul><li>Wet Surface Air Cooling (WSAC): One fluid is passed through pipes while another is sprayed onto the outside. Evaporation removes the heat from the first fluid, which is cooled as a result. Seawater can be used as the spraying fluid, but deposits of salt can build up on the pipes and surfaces, requiring more frequent cleaning and maintenance.</li><li>Closed-loop cooling: Closed-loop cooling functions in a similar way to WSAC, but the seawater is channeled through a heat exchanger, cooling a pipe carrying another fluid instead of spraying onto one.</li><li>Saltwater-to-air heat exchange: Similar to the above, but the seawater is channeled through pipes and exposed to air on the outside. Heat is transferred from the air to the seawater.</li><li>Saltwater evaporative cooling: Seawater can also be used in an evaporative cooling system, but the process requires additional equipment to filter out the salt and minerals.</li></ul><p>The key point to take away from this is that while seawater is a valuable resource for cooling, it must be treated accordingly to avoid damage to infrastructure.</p><h3>When the Location Becomes Part of the Cooling System</h3><p>We have discussed ways in which seawater and freshwater can help with cooling, but what about making use of the surrounding environment?</p><p>Google has a datacentre in Hamina, Finland that makes use of the surrounding seawater of the Bay of Finland to keep temperatures down. Google has also built an offsite heat recovery facility, which captures waste heat from data centres and is able to use it for other purposes. [7]</p><p>Microsoft’s Project Natick looked at a different approach: submerging a data centre in seawater. Microsoft’s Northern Isles module has been tested off the coast of Scotland for two years, with promising results. The underwater servers only experienced a breakdown rate of 1/8 compared to a land-based control group. [8]</p><p>Green Mountain in Norway takes advantage of the cold temperatures of a nearby fjord, using it to cool servers housed in the building. By passing the cold water from the fjord through a heat exchanger, the heating load of the facility is reduced, without having to pass seawater directly through the servers. [3]</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*T9XTbrX_0FResUIr4TZVzA.png" /><figcaption><em>Figure 4. Cold water from a nearby Norwegian fjord is used to help cool Green Mountain’s data centre. Source: Green Mountain (n.d.).</em></figcaption></figure><h3>What About Places Without Cold Seawater?</h3><p>Not every data centre can be built beside a cold body of water, especially not in the UAE, and not not without considering the climate. Although there is plenty of seawater in the UAE, it is much warmer than in a Nordic climate</p><p>Instead of trying to replicate the methods used by Green Mountain, facilities in the UAE would have to make use of other cooling strategies, including closed-loop liquid cooling, seawater heat exchange, and thermal storages to reduce the impact of evaporative cooling on freshwater resources. Is there merit in considering location and electrical storage options before one selects their cooling system?</p><h3>My Hot Take</h3><p>I believe that cooling systems for data centres should be considered as an entire energy-storage system, rather than just the means of heat dissipation.</p><p>Rather than focussing on the production and consumption of electricity, we should rethink the timing of when cooling is produced and consumed, and whether or not it can be stored to be used at a later time.</p><p>I believe that thermal storage can help to make data centres more efficient, by reducing peak time electricity consumption.</p><h3>Conclusion</h3><p>Data centres are growing to be an essential part of our digital infrastructure, but the environmental and physical aspects must be considered before rushing to build new facilities. Servers generate heat that must be dissipated with electricity, and some methods of cooling require a significant amount of freshwater.</p><p>Each technique has its benefits and drawbacks, so we will need multiple methods of cooling to suit multiple locations. While air cooling and evaporative cooling may be useful in some situations, direct-to-chip liquid and immersion cooling are better suited for high-density computing. Seawater can reduce the amount of freshwater needed for large-scale facilities, assuming the system is compatible with saltwater. Thermal storage can reduce the amount of electricity consumed by cooling systems at peak times, and electrical storage can provide both backup power and reduce the demand on the overall power grid.</p><h3>About Me</h3><p>My name is Alisha Rebecca Zacharia, and I am a member of The Knowledge Society (TKS). I am interested in energy storage and how it can help address challenges in our electricity systems, especially as renewable energy and data centres continue to grow. Through this article, I explored how different storage and cooling technologies can work together to make energy use more reliable and efficient.</p><h3>References</h3><p><strong>[1]</strong> Data Center Knowledge. “Data Center Cooling Methods: Costs vs. Efficiency vs. Sustainability.”<br><a href="https://www.datacenterknowledge.com/cooling/data-center-cooling-methods-costs-vs-efficiency-vs-sustainability">https://www.datacenterknowledge.com/cooling/data-center-cooling-methods-costs-vs-efficiency-vs-sustainability</a></p><p><strong>[2]</strong> Environmental and Energy Study Institute (EESI). “Data Centers and Water Consumption.”<br><a href="https://www.eesi.org/articles/view/data-centers-and-water-consumption">https://www.eesi.org/articles/view/data-centers-and-water-consumption</a></p><p><strong>[3]</strong> Green Mountain Data Centers. Information on cooling and facility design.<br><a href="https://greenmountain.no/">https://greenmountain.no/</a></p><p><strong>[4]</strong> TechRadar Pro. “A Concrete Thermal Battery Could Be Key to Cooling Data Centers at Scale.”<br><a href="https://www.techradar.com/pro/a-concrete-thermal-battery-could-be-key-to-cooling-data-centers-at-scale-150kw-prototype-that-can-withstand-up-to-500-degrees-centigrade-is-running">https://www.techradar.com/pro/a-concrete-thermal-battery-could-be-key-to-cooling-data-centers-at-scale-150kw-prototype-that-can-withstand-up-to-500-degrees-centigrade-is-running</a></p><p><strong>[5]</strong> Dubai Media Office. “DEWA Hydroelectric Power Plant in Hatta.”<br><a href="https://mediaoffice.ae/en/news/2023/september/12-09/dewa-hydroelectric-power-plant-in-hatta">https://mediaoffice.ae/en/news/2023/september/12-09/dewa-hydroelectric-power-plant-in-hatta</a></p><p><strong>[6]</strong> Data Center Knowledge. “Turning Off the Tap: The Case for Seawater Cooling in Data Centers.”<br><a href="https://www.datacenterknowledge.com/cooling/turning-off-the-tap-the-case-for-seawater-cooling-in-data-centers">https://www.datacenterknowledge.com/cooling/turning-off-the-tap-the-case-for-seawater-cooling-in-data-centers</a></p><p><strong>[7]</strong> Google Data Centers. “Hamina, Finland.”<br><a href="https://datacenters.google/locations/hamina-finland/">https://datacenters.google/locations/hamina-finland/</a></p><p><strong>[8]</strong> Microsoft Research. “Project Natick.”<br><a href="https://www.microsoft.com/en-us/research/project/natick/overview/">https://www.microsoft.com/en-us/research/project/natick/overview/</a></p><p><strong>[9]</strong> U.S. Department of Energy. “DOE Releases New Report Evaluating Increase in Electricity Demand from Data Centers.”<br><a href="https://www.energy.gov/articles/doe-releases-new-report-evaluating-increase-electricity-demand-data-centers">https://www.energy.gov/articles/doe-releases-new-report-evaluating-increase-electricity-demand-data-centers</a></p><p><strong>[10]</strong> Chen, X.; Wang, X.; Colacelli, A.; Lee, M.; Xie, L. “Electricity Demand and Grid Impacts of AI Data Centers: Challenges and Prospects.” arXiv, 2025.<br><a href="https://doi.org/10.48550/arXiv.2509.07218">https://doi.org/10.48550/arXiv.2509.07218</a></p><p><strong>[11]</strong> Choukse, E. et al. “Power Stabilization for AI Training Datacenters.” arXiv, 2025.<br><a href="https://doi.org/10.48550/arXiv.2508.14318">https://doi.org/10.48550/arXiv.2508.14318</a></p><p><strong>[12]</strong> Wang, D. et al. “Energy Storage in Datacenters: What, Where, and How Much?” <em>ACM SIGMETRICS Performance Evaluation Review</em>, 2012.<br><a href="https://doi.org/10.1145/2318857.2254780">https://doi.org/10.1145/2318857.2254780</a></p><p><strong>[13]</strong> Sun, M. et al. “Hierarchical and Hybrid Energy Storage Devices in Data Centers: Architecture, Control and Provisioning.” <em>PLOS ONE</em>, 2018.<br><a href="https://doi.org/10.1371/journal.pone.0191450">https://doi.org/10.1371/journal.pone.0191450</a></p><p><strong>[14]</strong> Zhang, Y. et al. “Unlocking the Flexibilities of Data Centers for Smart Grid Services: Optimal Dispatch and Design of Energy Storage Systems under Progressive Loading.” <em>Energy</em>, 2025.<br><a href="https://doi.org/10.1016/j.energy.2025.134511">https://doi.org/10.1016/j.energy.2025.134511</a></p><p><strong>[15]</strong> i-TES. “Data Centers as Heat Plants: Thermal Storage as the New Frontier of Energy Efficiency.”<br><a href="https://www.i-tes.eu/en/blog/39/data-centers-as-heat-plants-thermal-storage-as-the-new-frontier-of-energy-efficiency.html">https://www.i-tes.eu/en/blog/39/data-centers-as-heat-plants-thermal-storage-as-the-new-frontier-of-energy-efficiency.html</a></p><p><strong>[16]</strong> Environmental and Energy Study Institute (EESI). “Energy Storage.”<br><a href="https://www.eesi.org/papers/view/energy-storage-2019">https://www.eesi.org/papers/view/energy-storage-2019</a></p><p><strong>[17]</strong> U.S. Department of Energy. Data-centre electricity-demand research and related energy-system resources.<br><a href="https://www.energy.gov/">https://www.energy.gov/</a></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=1fe4b816eb65" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>