<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by AllumiaX Engineering on Medium]]></title>
        <description><![CDATA[Stories by AllumiaX Engineering on Medium]]></description>
        <link>https://medium.com/@allumiax?source=rss-ebc74255bd38------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/2*YKPjWVgxCltYqUqsYhNpvA.png</url>
            <title>Stories by AllumiaX Engineering on Medium</title>
            <link>https://medium.com/@allumiax?source=rss-ebc74255bd38------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Fri, 27 Nov 2026 20:09:04 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@allumiax/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Relay Settings in Real Power System: Requirements And Consideration]]></title>
            <link>https://allumiax.medium.com/relay-settings-in-real-power-system-requirements-and-consideration-4180e69adef2?source=rss-ebc74255bd38------2</link>
            <guid isPermaLink="false">https://medium.com/p/4180e69adef2</guid>
            <dc:creator><![CDATA[AllumiaX Engineering]]></dc:creator>
            <pubDate>Mon, 07 Nov 2022 10:12:42 GMT</pubDate>
            <atom:updated>2022-11-29T07:44:49.777Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*C-Tf2Hm5ola-HsHZvuY-GA.png" /></figure><p>This blog consists of a discussion on the parameters and rules in the relay setting and how they are implemented.</p><p>The power system consists of generators, transformers, transmission lines, and other equipment whose costs is in millions of dollars. Power system equipment can severely be affected by faults, reducing their lifespan, or even getting burst or damaged which also reduces reliability and increases utility costs.</p><p>Power protection devices can be used to protect power systems equipment from getting damaged due to heavy faults and surges. Protective devices ensure the reliable operation of the system by sensing faults, surges, or any abnormal condition and according to the severity takes the right decision at the right time.</p><p>To configure protective devices such as making a relay setting, having all the consideration of the fault severity and decision-making time, it is important to know parameters, rules, and protection zone so that the reliability of the power system having continuous supply, is not compromised. Without prior knowledge of relay settings, reliability is affected badly and it can cause a penalty to the distributor.</p><h3>Stay Sharp &amp; Join our Mailing List!</h3><p>Our surveys show that 90% of the people who join our blog have found the content valuable! <a href="http://bit.ly/3VBmUhn">Join today</a></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/399/1*W_IrEBy8AU9V72A1QoVcaw.png" /><figcaption><a href="http://bit.ly/3VBmUhn"><strong>Signup Now</strong></a></figcaption></figure><h3>Types of Relay</h3><h3>Based on Operating Mechanism:</h3><ul><li>Electromagnetic (mechanical type)</li><li>Static (electronics type)/ Solid State Relay</li><li>Microprocessor-based (programmable and communicating type)</li></ul><blockquote>We’ve also written a blog on <a href="https://www.allumiax.com/blog/advantages-of-numerical-relays-over-electromechanical-relays"><strong>Electromechanical Relays and Numerical Relays</strong></a>.<strong> </strong>If this grabs your interest, check it out and let us know your feedback.</blockquote><h3>Based on Actuating Parameter:</h3><ul><li>Overcurrent</li><li>Under/over voltage</li><li>Impedance</li><li>Under/over frequency</li></ul><h3>Based on Application:</h3><ul><li>Primary</li><li>Backup</li></ul><h3>Based on Protection Scheme:</h3><ul><li>Differential protection (difference in current)</li><li>Distance protection (V/I and time + distance)</li><li>Directional protection (time + direction of current)</li><li>Reverse power relay (negative sequence component)</li></ul><blockquote>Read this blog to learn more about <a href="https://www.allumiax.com/blog/protection-schemes-for-electrical-power-system"><strong>Protection Schemes for Electrical Power Systems</strong></a>.</blockquote><h3>Overcurrent Relay</h3><p>Overcurrent is the most used relay protective scheme as compared to others.</p><h3>Definition:</h3><p>An overcurrent relay works on sensing current. It operates whenever the current exceeds a permissible value or pickup value.</p><h3>Layout:</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/600/1*bFHFpiosTWLI7LzbfNaFjw.png" /></figure><p>An overcurrent relay works such that the system current is sensed by a current transformer (C.T). The primary side of C.T is connected to the system and the secondary side with a relay. In case of:</p><ul><li><strong>Fault/overload/ overcurrent:</strong> the relay operates and gives a trip signal to the breaker with respect to time.</li><li><strong>No fault: </strong>the relay performs no operation</li></ul><h3>Types:</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/855/1*GLSJSnjmoHGk5N0kYKKT9g.png" /></figure><p>Be cleared to avoid damage to the apparatus. Following inverse time characteristics have been standarized.</p><ol><li>Inverse definite minimum time (IDMT) OC relay.</li><li>Very Inverse time OC relay.</li><li>Extremely inverse time OC relay</li></ol><figure><img alt="" src="https://cdn-images-1.medium.com/max/300/1*ds8j2wRNrYl7JlP8VpHVkA.png" /></figure><p>Characteristics of various over-current relays: (a) definite time, (b) IDMT, © very inverse, and (d) extremely inverse.</p><h3>Common Terms:</h3><h3>1. Pickup Current (Ipu):</h3><h4>Definition:</h4><p>Minimum amount of current required for the operation of the relay.</p><h4>Objective:</h4><p>Power system components work properly at a certain allowed current and when the magnitude of current exceeds a certain value (as in case of a fault), it can cause damage to the component and the entire system reliability is compromised. The relays are designed to operate above these rated currents. The pickup current is thus set at the maximum allowed current.</p><h4>Formula:</h4><p><em>Ipu = Rated CT output * %current setting</em></p><p>where,</p><p>Rated CT output is the rated current at the secondary side of the current transformer, typically 1A or 5A.</p><h3>2. Current Setting:</h3><h4>Definition:</h4><p>To adjust the pickup current (Ipu) to the desired value.</p><h4>Objective:</h4><p>C.T output comes in standard for example: <strong>5A</strong> according to IEC and <strong>1A</strong> according to IEEE.</p><p>The current setting sets the pickup value according to it so that the relay can operate at pickup current instead of working at rated C.T output</p><h3>3. Plug Setting Multiplier (PSM):</h3><h3>4. Time Setting Multiplier (TSM):</h3><h3>5. Time/PSM Curve:</h3><blockquote><a href="https://www.allumiax.com/blog/relay-settings-in-real-power-system#commonterms"><em>C</em><strong><em>lick here</em></strong></a><em> to read detailed explanation of each </em>Common Terms<em>.</em></blockquote><h3>Calculation of Relay Operation Time</h3><h3>Procedure:</h3><ul><li><strong>Step1:</strong> Calculating pickup-current.</li><li><strong>Step2: </strong>Converting fault current into relay coil current by dividing fault current with C.T ratio.</li><li><strong>Step3: </strong>Calculating PSM</li><li><strong>Step4: </strong>From the time/PSM curve of a provided relay, determine the value of time of operation (at TSM=1) from the calculated PSM.</li><li><strong>Step5: </strong>Multiplying the time from time/PSM curve with the required TSM to get the time of operation.</li></ul><h3>Solved Example:</h3><p>Considering the following data:</p><p>C.T = 100 / 1</p><p>Breaker continuous current = 80 A</p><p>TSM = 50%</p><p>Fault current = 800 A</p><p>Time = 2s (at PSM=10 for time / PSM curve)</p><p><strong>Solution:</strong></p><p>Current setting = 80 / 100 (from eq2)</p><p>Current setting = 0.8 or 80%</p><p>Ipu = 1*0.8 (from eq 1)</p><p>Ipu = 0.8 A</p><p>Relay coil current = 800 / (100 / 1) (from eq 4)</p><p>Relay coil current = 8</p><p>PSM = 8 / 0.8 (from eq 3)</p><p>PSM = 10</p><p>top = 2 * 50 / 100 (from eq 5)</p><p>top = 1s</p><h3>Principle of Time/Current Grading</h3><p>A time/PSM curve for relays can be set in any of the three ways, which are described as:</p><h4>Discrimination by Time:</h4><p>A constant time setting is given to each relay irrespective of the magnitude of the current.</p><p>The issue with this method is that the relay closest to the source has the largest delay while it has the maximum fault current that could flow within the system, which can damage the system due to a large time delay.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/400/1*cxejV2DE1vPUooWujfMlvg.png" /></figure><h4>Discrimination by Current:</h4><p>This method is based on the phenomenon that fault current amplitude varies with a change in impedance between source and fault.</p><p>The main issue with this method is that there should be a good distance between two breakers as the relay would not be able to detect faults if the distance between two zones breaker is less.</p><h4>Discrimination by both Time and Current:</h4><p>This method is based on the fact that with an increase in fault current, the clearance time should reduce.</p><p>There are three types of inverse time-current characteristic curves:</p><ul><li>Inverse definite minimum time (standard inverse)</li><li>Very inverse time</li><li>Extremely inverse time</li></ul><p>Extremely inverse time has the minimum clearance time with an increase in fault current than very inverse time and lastly inverse definite minimum time.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/404/1*c4lFhPuB9vHCjhnx4xXXSA.png" /></figure><h3>Primary and Backup Protection</h3><h3>Zones of Protection:</h3><p>For better security of elements that is relay associated with faulty area sense and clear the fault on first priority power system components are divided into the region. Faults can be classified into two with respect to the defined zone:</p><ol><li>Internal fault: fault within the zone</li><li>External fault: fault outside the zone</li></ol><p><strong>Reach point: </strong>The farthest point from a relay in a specified zone.</p><p><strong>Reach of the relay:</strong> Distance between relay and reach point.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/250/1*1vt507Y8sWbHnesczf-FGQ.png" /></figure><p>Here the power system zones are being overlapped due to reason that no zones remain unprotected.</p><p>As each power system element generator, transformer, transmission lines, and others have a different structure, cost, and functionality, they are divided into a separate zone for better security. As fault within a zone can be internal and external, depending upon the type of fault protection scheme can be classified into two types:</p><h3>Primary Protection:</h3><p>They are concerned with internal fault and are efficient enough to detect a fault in the least possible time within a zone and gives a trip signal. Primary protection schemes are usually implemented using differential, distance, and directional overcurrent protection.</p><h3>Differential Protection:</h3><p>Differential protection works on the current matching principle that is two CTs are connected in a region in such a way that whenever there is a difference in current within that region, the relay gives a trip signal, else no tripping.</p><p>They are used in power transformers, generators, and bus bar protection schemes.</p><h3>Distance Protection:</h3><p>In transmission lines, it is not possible to implement differential protection. For transmission line protection, distance protection is used which is based on ohm’s law that measures voltage and current, if the measured impedance is less than the transmission line impedance then the relay gives a trip signal.</p><h3>Directional Overcurrent Protection:</h3><p>A directional protection scheme becomes functional in the case of a double-end feed system or parallel lines or a ring main system, where a fault gets fed from both sides. It senses the current magnitude and direction for the decision-making purpose.</p><h3>Backup Protection:</h3><p>For better reliability purposes, backup protection schemes are used. They are less efficient than primary protection but are used for the purpose, if primary protection does not give a trip signal due to some reason in case of fault, the backup protection trips after some delay. They are also used in detecting external faults. Backup protection is achieved using overcurrent relay.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/400/1*V9EMwxH-Gk1aS8o4NWi6Sg.png" /></figure><h3>Coordination Methodology</h3><p>The following methodology is adopted for the overcurrent protection of the power system:</p><h3>Data Required:</h3><ol><li>Single line diagram, indicating rating, manufacturer, and types of each element including C.T, motors, generators, transformer, cables and protective devices (for accurate short circuit calculation and relay coordination)</li><li>Impedance of rotating machines and transformers (as they also take part in fault current)</li><li>Minimum and maximum fault current. (for time-setting purposes)</li><li>Maximum loading ( to get an overload of the system)</li><li>Voltage level (for selection of the type of circuit breaker and relay)</li><li>Starting and inrush current, damage curves of cables and transformer, induction motor stalling time and acceleration time (these variables are considered in order to prevent nuisance tripping)</li></ol><h3>Rules:</h3><ol><li>If possible, relays having similarities in operation should be placed in series.</li><li>Relay farthest from the source must have a current setting less than or equal to the relay behind it, as the relay in front requires less current to operate as compared to the relay behind it.</li></ol><h3>IEEE Standards for Relay Settings:</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*U_hb4BgSFKQFb_nvVsD-XQ.png" /></figure><h3>Coordination for Radial Feeders:</h3><p>Following example shows the coordination of three relays A, B, and C.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/548/1*bUYPledtu0vZU9VOZuGCgA.png" /></figure><p>When a fault occurs in front of relay C, it will be sensed by all 3 relays. Here relay C will act as a primary relay and relay B and A as backup, it will be desired that relay C trips first, then relay B if relay C fails to trip, and then relay A if relay B fails to trip. Here time of operation of relay C is adjusted lowest among the two other relays for maximum and minimum fault front of relay C.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/548/1*ReI49d-bBNzI6fLwDCHClA.png" /></figure><p>When a fault occurs in front of relay B and relay C, it will be sensed by only relay A and B relays. Here relay B will act as a primary relay and relay A as backup, it will be desired that relay B trips first, then relay A if relay B fails to trip. Here time of operation of relay B is minimum than relay A for maximum and minimum fault front of relay C.</p><h3>Directional Overcurrent Relay Setting for Different Scenarios:</h3><p>Following are the cases where directional overcurrent protection is used to fulfill the selectivity requirement.</p><h4>Load Connected to a Generator through Parallel Transmission Line:</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/500/1*ni_i4X_m5Wib2b07AvVuzw.png" /></figure><p>In the given system relay 1 &amp; 4 are non-directional relay while 2 &amp; 3 are directional relay with minimum TMS.</p><h4>Ring System:</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/500/1*sCxXTgHh_cNc-w-q09UNSg.png" /></figure><p>In the given system, 1 &amp; 8 are non-directional relays while 3, 5 &amp; 7 are relays that will sense fault in a clockwise direction, and 2, 4 &amp; 6 in counter-clockwise direction that is 2, 3, 4, 5, 6, 7 are directional relays.</p><p>In this blog we have understood different types of relays, their settings, and their coordination methodology and in last we have included a brief overview regarding directional overcurrent relay for different types of systems. Relay settings are the essential part of protective scheme for Power System and its coordination is one of the prime focuses of protection for Power System.</p><blockquote><em>We here at AllumiaX perform different types of studies related to the protection of Power system. Engineers at AllumiaX are capable of providing high quality protective device coordination study including Protective Relay Settings and Coordination Services. Get in touch with us at </em><a href="/service/mailto:support@allumiax.com"><em>support@allumiax.com</em></a></blockquote><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=4180e69adef2" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Methods of Solar Power Generation]]></title>
            <link>https://allumiax.medium.com/methods-of-solar-power-generation-5d3af3719fc8?source=rss-ebc74255bd38------2</link>
            <guid isPermaLink="false">https://medium.com/p/5d3af3719fc8</guid>
            <dc:creator><![CDATA[AllumiaX Engineering]]></dc:creator>
            <pubDate>Tue, 27 Sep 2022 08:04:50 GMT</pubDate>
            <atom:updated>2022-11-29T13:14:43.974Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*Z1ZbfRjiNlNvgEBfdi25mA.png" /></figure><p>Sun being the infinite source of power, Solar Energy is considered a power source that won’t ever run out. We have multiple energy resources, and most of them are running out as the demand for power increases with the advancement of technology, industrialization, and urbanization. If all the non-renewable energy resources run out, the sun itself would be enough to serve the power demand of the whole world. As time passes by, we are already running out of conventional energy resources, and this signifies how important it is for us to focus on the development of systems that are solely dependent upon Solar Power. This article focuses on the different methods of Power generation through solar energy and discusses the significance and scope of the most advanced and commonly used methods, throughout the globe.</p><h3>Stay Sharp &amp; Join our Mailing List!</h3><p>Our surveys show that 90% of the people who join our blog have found the content valuable! <a href="http://bit.ly/3VBmUhn">Join today</a></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/399/0*KbJ6UKCwGreX0AKL.png" /><figcaption><a href="http://bit.ly/3VBmUhn">Signup Now</a></figcaption></figure><h3>Sources of Solar Power:</h3><p>Sources of Solar Power can be widely categorized into Solar Photovoltaic modules and Solar Thermal Power.</p><p>Photovoltaic modules Based on the type of crystal used, commercially available PV technologies being used in the power systems today can be classified into the following types:</p><ol><li>Crystalline PV cells</li><li>Non-crystalline PV cells</li><li>Hetero junction cells</li></ol><h3>CRYSTALLINE PV CELLS:</h3><p>Crystalline PV modules are made by grouping several individual crystalline silicon solar cells (c-Si) which are in fact silicon atoms combined in the form of a crystal lattice. These are currently the most used type of modules being used frequently for both residential as well as commercial systems due to their higher efficiencies than the other PV technologies.</p><p>Crystalline PV cells can be further categorized into two kinds:</p><ol><li>Monocrystalline cells</li><li>Polycrystalline cells</li></ol><h4>MONOCRYSTALLINE CELLS:</h4><p>Monocrystalline solar cells are those in which each cell is made of a single silicon crystal. These cells have a black hue with rounded edges. Their dark appearance is due to how photons interact with the pure silicon crystal. They have higher energy conversion efficiency than an equally powered polycrystalline solar panel and thus are more space efficient. However, due to the adequate functionality it offers, it is more expensive. It has a high-temperature coefficient which makes it less affected by changes in temperature.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/628/1*TebNG_NlZnIUymtRUzpxkg.png" /></figure><h4>POLYCRYSTALLINE CELLS:</h4><p>Multiple silicon fragments are melted together to produce the wafers of a multi or polycrystalline cell. They tend to have a bluish hue. The electrons in the cell have lesser space to flow due to multiple crystals in the cell thus making this kind less efficient as compared to the monocrystalline solar cells. But are more affordable for consumers. So, if you don’t have a limitation of space, polycrystalline panels might work well to provide the same output power with a couple more panels. The temperature coefficient of polycrystalline cells is lower implying their efficiencies decrease for every one-degree rise in temperature than the panel-rated temperature (usually 25 degrees Celsius or 77 degrees Fahrenheit).</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/633/1*Mhyg9NFvAelvvk9vbMwP4Q.png" /></figure><h3>NON-CRYSTALLINE PV MODULES (THIN FILM)</h3><p>Thin Film solar panels are non-crystalline and comprise of multiple thin layers of PV materials. These are flexible and light weighted. Depending on what they are made from, thin film panels come in both black and blue hues. Thin Film cells deposit a material that can produce a PV effect on a backing medium called a substrate. The substrate can be a glass sheet, PVC roofing material, foil sheet, etc. The name thin film in fact implies that the substrate material is really thin ranging from just nanometers to a few micrometers thick. They cost less than traditional solar PV technology but require large space for installation. Thus, are not recommended for residential systems.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/267/1*LRmj8zSw1lEu0RmqZZh3TA.png" /></figure><p>On the basis of the type of substrate used, there are 4 most commonly used types of thin film panels.</p><ul><li><strong>Cadmium Telluride (CdTe): </strong>A very thin layer of CdTe merely micrometers thick is deposited onto the substrate (usually glass). Another glass sheet is adhered to the first for the protection of the cells thus making these types of thin film panels to be used in place of conventional windows too. The cost of the raw materials used to manufacture this type is very low implying its economic feasibility. However, keeping in mind the fact that tellurium is a rare earth element, mass production of these panels might not be reasonable.</li><li><strong>Amorphous silicon (a-Si): </strong>It is the most prevalent type of thin film module. a-Si has the ability to be combined with non-rigid substrates such as flexible vinyl sheets or PVC roofing materials. This allows a-Si PV modules to be largely used for commercial flat roofs or building integrated photovoltaics. It is an attractive option in terms of aesthetics as well as cost when installed on a relatively larger surface area.</li><li><strong>Copper Indium Gallium Selenide (CIGS): </strong>This type uses four different raw materials, and the substrate material can be both flexible and rigid. It can be manufactured with a few nanometers of the material deposited on the substrate, due to which it has gained popularity in recent years. Less manufacturing material usage reduces cost without reducing efficiency. The cells are manufactured in the form of cylindrical tubes which makes them perpendicular to the sun for longer periods of time, thus increasing energy production.</li><li><strong>Gallium Arsenide (GaAs): </strong>Thin-film solar panels made with Gallium Arsenide are deemed to be the most efficient of all thin-film panels. However, because of their high costs, they are usually used in developing spacecraft and other types of specialized applications where PV energy is essential.</li></ul><h3>HETERO JUNCTION CELLS:</h3><p>Solar cells that are developed by the conjunction of crystalline technology with thin film technology are called heterojunction cells. This technique increases the overall efficiency as well as the power output as it combines the strengths of both and improves the lifespan of the modules. However, making them costly to purchase but otherwise pertains to a decreased Levelized Cost of Energy (LCOE).</p><p>They are typically used in high visibility applications such as solar awnings or patio covers. This technology is less affected by the changes in temperature making it useful for higher temperature locations.</p><p>Following are the three commonly used materials for HJT cells:</p><ul><li>Crystalline Silicon (c-Si)</li><li>Amorphous Silicon (a-Si)</li><li>Indium Tin Oxide (ITO)</li></ul><figure><img alt="" src="https://cdn-images-1.medium.com/max/600/1*_BSMLS5IDsAwUs3YSD7Igw.png" /></figure><h3>COMPARISON OF DIFFERENT TYPES:</h3><p>The table below shows a comparison between different types of commercially available PV technologies.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/850/1*G2Rhkny_tekJebcyA1HV7w.png" /></figure><h3>Solar Technologies Based on Thermal Power (Solar Thermal):</h3><ul><li>Flat plate collectors</li><li>Evacuated tube collectors</li><li>Concentrating Solar Power (CSP) Technology</li></ul><h3>Flat Plate Collectors:</h3><p>A flat plate collector is simply a flat rectangular box, with a layer of glazing sheet to avoid heat loss, a fluid inlet, and an outlet, tubes arranged in parallel through which the fluid flows. The ‘Heat Absorbing Plate’ placed at the bottom absorbs the sun’s heat and efficiently transfers it to the water running through the tubes. Usually, flat plate collectors provide temperatures up to 100 degrees Celsius. This can be utilized for different domestic and industrial applications. Air and water both can be used in flat plate collectors as working fluids, although it’s not used for the sake of power generation, but just to provide effective means of saving energy.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/600/1*hyiiF3h6PahaxK5omjjixg.png" /></figure><h3>Evacuated Tube Collectors:</h3><p>The Evacuated Tube Collectors work in a similar way to a Flat Plate collector, but their components are slightly different which enables them to yield higher efficiency. Unlike Flat Plat collectors, evacuated Tube collectors do not have Flat plates, and each of its pipes has its Individual heat transfer fin and Evacuated tube. As a result of this tubular structure, its capable of facing the sun directly from all locations, while flat plate collectors only receive direct irradiance when the sun is facing it perpendicularly, this attribute of evacuated tube collectors helps them to work at a higher efficiency.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/423/1*IjJaveKMcsuzWJtDb32bOg.png" /></figure><p>Heat pipes contain evaporating and condensing liquids that absorb heat and release it to the heat sink region. This heat is absorbed by the water or any system fluid in the header pipe which is then utilized for the designated purpose.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/650/1*bpubkaBYqzO0VLw9MQAkBA.png" /></figure><h3>Concentrated Solar Power (CSP):</h3><p>Concentrated Solar Power is a different technology than Photovoltaic Systems, and it depends upon using the sun’s Heat Energy to Generate Power. In concentrated Solar Power Systems, huge mirrors are used to concentrate the sun’s light at one point. The working fluid absorbs a high amount of heat energy, which is being focused at one point, this energy is further used to fuel steam turbines and heat engines.</p><p>Following are the types of concentrated systems:</p><ul><li>Parabolic Troughs</li><li>Solar Dish/Parabolic Dish</li><li>Solar Power Tower</li><li>Linear Fresnel Reflectors</li></ul><p>The availability of sun is limited to only in day times, which would limit the performance of a system if we would be completely dependent on the CSP. Therefore, generally, CSP is integrated into the systems where we can also have other means of heating available so that the system would be capable of working in all circumstances.</p><h4>1. Parabolic Troughs:</h4><p>A parabolic trough is a ‘U-shaped’ structure, with mirrors placed inside of it. The Central Heating pipe is present in the middle of this structure, all the sunlight that hits the collector mirrors is reflected to the heating pipe. The rotational axis of this parabolic trough is around the heating pipe, and it rotates around its axis to track the location of the sun.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/700/1*IoqWDNIDSET08790183cQQ.jpeg" /></figure><p>The Central heat pipes are 70mm Heat Collectors, which are surrounded by Vacuum Jackets for the sake of insulation. Vacuum Jackets minimize the heat loss from the Heat transfer fluid. The heat transfer being used here is generally mineral oil or synthetic oil. This fluid goes to a heat exchanger where steam is produced, this steam is used in a conventional reheat steam turbine-generator to produce electricity.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/600/1*az2kc4VREkV-LdHDJXtrBw.png" /></figure><h4>2. Linear Fresnel Reflectors:</h4><h4>3. Parabolic Dish:</h4><blockquote><a href="https://www.allumiax.com/blog/methods-of-solar-power-generation#LinearFresnel"><em>C</em><strong><em>lick here</em></strong></a><em> to read detailed explanation of Liner Fresnel Reflectors and Parabolic Dish.</em></blockquote><h4>4. Solar Power Tower:</h4><p>A Solar Power Tower is surrounded by huge rotating mirrors which track the location of the sun and reflects the sun’s heat to the receiver placed on the top of the Solar Power tower. The receiver contains “Molten Salt” also called nitrate salt (60% NaNO3 and 40% KNO3) which absorbs the suns heat, which can either be stored or used to produce electricity. Molten Salt is used in Solar Power Tower as a working fluid due to its capability of heat transfer and retaining heat for a longer period. Molten salts are usually Solid at room temperature, but as it absorbs heat it gets liquified, and then it is utilized for the sake of power generation.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/330/1*h_f5hNFI2ZxmNkb5P15l2w.png" /></figure><p>Following are the main components of a Solar Tower Power Generation system:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/500/1*XypV6n7PGztc3cz26onuUA.png" /></figure><p>The salt is moved from a Cold Storage tank to the cylindrical receiver where it absorbs the sun’s heat. This salt with a high amount of thermal energy stored in it is then brought to the Hot Storage tank, where it is stored until the power needs to be supplied to the grid. Then it is moved from the Hot Salt Storage to the steam generator, where it provides temperatures up to 565 degrees Celsius and generates steam. This steam is further utilized to run the Steam turbine. The salt that now has deposited its thermal energy in the steam generator is now collected in the Cold Storage tank, and the cycle repeats itself.</p><blockquote>AllumiaX is a licensed Engineering company headquartered in Seattle, Washington USA. We work with sub-contractors to deliver various Power System Engineering studies including DC arc flash and DC short circuit studies for your Solar system. Get in touch with us at <a href="/service/mailto:support@allumiax.com">support@allumiax.com</a></blockquote><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=5d3af3719fc8" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Transfer Switches and Safety Switches]]></title>
            <link>https://allumiax.medium.com/transfer-switches-and-safety-switches-a148e07cfb1d?source=rss-ebc74255bd38------2</link>
            <guid isPermaLink="false">https://medium.com/p/a148e07cfb1d</guid>
            <dc:creator><![CDATA[AllumiaX Engineering]]></dc:creator>
            <pubDate>Mon, 26 Sep 2022 13:12:02 GMT</pubDate>
            <atom:updated>2022-12-02T10:46:44.642Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*5dmHtbOX7vcD4cJsDgMj6g.png" /></figure><h3>Why are Switches used in Industries?</h3><p>One of the most important concerns in an electrical power system is the continuous supply of power to the load. To maintain reliability, various facilities (for example, hospitals, schools, and industries) use different backup power sources (if the primary source (utility) is affected for any reason), that is why switches are used. Switches that are used in the facilities make it safe to close or transfer live circuits. In commercial and industrial facilities where high currents are involved, these switches are an essential component of the distribution system. By closing and opening circuits, they make the transfer of power easy and secure. In this blog we will be discussing about different types of switches (transfer and safety switches), importance, applications and comparison of these switches.</p><h3>Stay Sharp &amp; Join our Mailing List!</h3><p>Our surveys show that 90% of the people who join our blog have found the content valuable! <a href="http://bit.ly/3VBmUhn">Join today</a></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/399/0*IhPvnjGJVNLxESn6.png" /><figcaption><a href="http://bit.ly/3VBmUhn">Signup Now</a></figcaption></figure><h3>What is a Transfer Switch?</h3><p>Transfer switches are used to let you safely transition power from the utility to your standby generator at times when the utility power source fails. This is particularly useful in facilities where continuous power is required, like hospitals, manufacturing facilities, data processing centers and a lot of other commercial and industrial units. Secondary source of power could be a generator or a back-up utility feed depending on the availability of a utility. They are very important for safety of circuits and personnel as they stop the mains power from coming in contact with the backup generator and also prevent back feeding from the generator to the utility risking the lives of unsuspecting electricians working on the grid. Have you installed the right transfer switch in your facility? At AllumiaX we offer Short Circuit and Arc Flash Analysis to check the safety and reliability of the equipment installed, Click <a href="https://www.allumiax.com/arc-flash-study">here </a>to contact our professional.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/383/1*v3L5QAqoCVYl83kl3TbtnQ.png" /></figure><h3>Operation of Transfer Switches</h3><h4><strong>Manual Transfer Switches</strong></h4><p>These transfer switches need to be operated manually, by changing position of a lever mounted on the side of a transfer switch or by pushing a button. Manual transfer switches are robust as they don’t have any electronic parts so chances of them failing are slim. They are a great option when a delay in switching power is not an issue as they are least expensive choice in the options available. They are not ideal for facilities where continuous uptime is a legal or operational requirement because this mode takes the maximum time for switching.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/521/1*glNPgvpEfGdjNxjDB3wjWw.png" /></figure><h4>Non-Automatic Transfer Switches</h4><p>The difference between a non-automatic and manual transfer switch is their function. A non-automatic transfer is manually initiated and electronically operated, it gives you the ease of operating the transfer switch when the operator presses the button placed on the switch, button can also be placed remotely when the transfer switch is difficult to reach or unsafe for a technician to access.</p><p>This increases safety for the technician operating the switch as well as shaving off downtime during transitions because switching is done electromechanically.</p><h4>Automatic Transfer Switches</h4><p>Automatic transfer switches don’t need a person to activate switching, they have a smart controller which decides when to initiate and operate the transfer between the sources present to feed the load. For example, when a power plant for a college campus fails to produce power, an ATS (Automatic Transfer Switch) will detect this power loss automatically and will initiate and operate the mechanism to transfer the source of power from the power plant of the college campus to the utility feed without the need of a person to oversee the operation. Also, automatic transfer switches are used for safety-critical operations when it is necessary to switch power quickly. ATS tend to be more expensive than all the other switches, but they eliminate the need of an operator.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/414/1*1P7csu2HkVa_rFo1VL2cgg.png" /></figure><h3>Transfer Switch Transitions</h3><h4>1. Open Transition</h4><h4>2. Closed Transition</h4><blockquote><a href="https://www.allumiax.com/blog/transfer-switches-and-safety-switches#TransferSwitchTransitions"><em>C</em><strong><em>lick here</em></strong></a><em> to read detailed explanation of each Transfer Switch Transitions.</em></blockquote><h3>Why do we need Safety Switches?</h3><p>Safety Switches are a requirement by the NEC (National Electric Code) in all commercial and industrial applications. According to article 430.102B of the NEC a safety switch must be in sight of motors and all manufacturing equipment. In sight means less than 50 feet from the equipment. Safety switches can be used at service entrances as well, which means that they can be used to cut-off power from the utility to the whole facility.</p><h3>How does a Safety Switch work?</h3><p>A safety switch or a disconnect switch is a device that constantly monitors current and detects fault current in the system, it is essential for safety of people working near the electrical equipment. Upon finding a change in the circuit the safety switch will open the circuit instantly (no intentional delay).</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/270/1*xxEz6PNnBoAJg7WdbHmCdg.png" /></figure><p>One might confuse the working of a safety switch with a circuit breaker. In simple terms, a circuit breaker is a device that protects electrical equipment like lights, wiring and motors from overloading and shorting out which leads to over-heating, fire and damage to other parts of the system. On the other hand, a safety switch is installed to prevent an electrical shock to people while at work in some manufacturing facility or while using a baby monitor at home. The main difference between these two devices is that the circuit breaker (trip unit) is designed to protect equipment from higher currents than its circuits were designed for, while a safety switch was built to keep people safe when there is any leaking current available.</p><h3>Fusible Safety Switches and Non-Fusible Safety Switches</h3><p>Safety switches come in both fusible and non-fusible options, Fusible safety switches have an option to fit fuses in the safety switch, such safety switches provide a convenient means to manually open or close the circuits and provide circuit protection as well.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/250/1*exyRUhT1M5C6rSsoLKoxDw.png" /></figure><p>Non-fusible safety switches provide no such protection from overcurrent, they just offer the functionality to open and close the circuits, protection for the circuits must be provided by external overcurrent protection devices such as fuses or circuit breakers.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/209/1*vNesx4BmztTa-vRDd6hwfA.png" /></figure><h3>Types of Safety Switches</h3><p>According to application, there are four types of safety switches:</p><ol><li>General duty safety switches</li><li>Heavy duty safety switches</li><li>Double door safety switches</li><li>Elevator control safety switches</li></ol><h3>General Duty Safety Switches</h3><p>General duty safety switches that are used in residential and commercial applications. They are suitable for light duty applications, generally facilities where loads are not more than 30–600 amps and Voltages not more than 240 V, they could be used for service entrance applications or light duty motor circuits.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/177/1*0bW0zro_KP_Szw_jOqkxjw.png" /></figure><h3>Heavy Duty Safety Switches</h3><p>Heavy Duty safety switches are used in industrial and commercial applications where service continuity is critical, they have a current rating higher than light duty safety switches as the name suggests, their operating range extends from 30–1200 Amps and are suitable for applications up to 600 V.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/177/1*v-VpUhXtBoPdTBJRUBXU6Q.png" /></figure><h3>Double Door Safety Switch</h3><p>These fusible heavy duty safety switches have compartments that offer isolation from the line side to the load side through the compartmentalized design and the internal barrier that separates the line side from the load side. Contact with line-side power can be fatal for operators, the insulation offered by a double door safety switch ensures safety for operators during maintenance. Operating ranges of double door safety switches are same as heavy duty safety switches that is 30–1200 Amps and up to 600 Volts.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/210/1*tsl3h2oR30LkzdR5ucV1wQ.png" /></figure><h3>Elevator Control Safety Switch</h3><p>This switch helps meet all the codes associated with fire protection and safety requirements in elevators. Elevator control safety switches are ready for quick installation decreasing the amount of time and labor required to put together all components required. Operating ranges of elevator control safety switches are 30–400 A and 208–600V.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/160/1*g6STdZ8HMPEifGrD6xUYJw.png" /></figure><h3>Difference between Transfer Switches and Safety Switches</h3><p>Transfer switches are mostly used for transferring loads from one power source to another. A load could be connected to a utility but upon power outage we can shift the power source from the utility to the generator.</p><p>Safety switches on the other hand are used to connect and disconnect the power source from loads (motors) and used as a disconnecting means for a service entrance. They open the circuit once they detect a change in it, this change in the circuit could be a person who got electrocuted, the safety switch will sense this change and trip in a few milliseconds saving the person from getting a fatal shock.</p><h3>Comparison</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/941/1*P9azHmT24RbnLkou3tq0Sg.png" /></figure><p>We at Allumiax access all safety hazards related to electrical equipment in all industrial and commercial facilities. We can check if the safety switches and transfer switches used in your facility are of the appropriate rating and if they meet all standards or not. <a href="https://www.allumiax.com/blog/short-circuit-study-its-importance-in-power-systems">Click here</a> to learn more about the Short Circuit current rating of Safety switches and other equipment in our Short circuit study article. After testing the equipment we include Arc Flash Labels as attached below in our reports in compliance with NFPA 70E. These labels help Electricians working on the equipment know what level of safety gear to wear.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/326/1*3fSLXeXHWnI_BwUR0qzMbg.png" /></figure><blockquote>Get in touch with us <a href="https://www.allumiax.com/engineering-studies">here </a>to check that the ATS,MTS and safety switches used in your facility are adequately rated according to the short circuit current available and normal operating ranges of your facility.</blockquote><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=a148e07cfb1d" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Integration of Wind Energy Resources with Conventional Grids]]></title>
            <link>https://allumiax.medium.com/integration-of-wind-energy-resources-with-conventional-grids-e8f84734bd33?source=rss-ebc74255bd38------2</link>
            <guid isPermaLink="false">https://medium.com/p/e8f84734bd33</guid>
            <category><![CDATA[power-generation]]></category>
            <category><![CDATA[wind-energy]]></category>
            <category><![CDATA[grid]]></category>
            <category><![CDATA[harmonics]]></category>
            <category><![CDATA[power-factor]]></category>
            <dc:creator><![CDATA[AllumiaX Engineering]]></dc:creator>
            <pubDate>Thu, 18 Aug 2022 10:15:11 GMT</pubDate>
            <atom:updated>2022-12-02T10:49:09.826Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*F9Hw5PAX1cAZMPL582Rtlw.png" /></figure><p>As we are progressing in time, the non-renewable energy resources are running out and soon they won’t be enough to meet our needs. As necessity is the mother of invention, this need keeps pushing us to develop alternative energy resources which will eventually replace all the conventional energy sources one day. This development in the Power Generation sector gives new challenges to Power Engineers each day, and they strive to meet these challenges with the help of the latest technologies. In this blog, we will be discussing one of the most significant renewable energy resources today, which is being used across the globe. This blog will put some light on the technical challenges associated with the generation and integration of Wind Energy systems into conventional grids, and how these challenges are conquered through Power Engineering solutions.</p><h3>Stay Sharp &amp; Join our Mailing List!</h3><p>Our surveys show that 90% of the people who join our blog have found the content valuable! <a href="http://bit.ly/3VBmUhn">Join today</a></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/399/0*aFc-OG6ZkpnX69EG.png" /><figcaption><a href="http://bit.ly/3VBmUhn">Signup Now</a></figcaption></figure><h3>Wind Energy</h3><p>As this self-explanatory term suggests, wind energy means to use wind intelligently in order to generate energy through it. For this purpose, we use wind turbines, which fetch wind kinetic energy and convert it into a rotary motion that is further converted into Electrical Energy through a generator. So, the primary components of a wind turbine are Turbine blades, rotor, gearbox, generator, and sometimes also DC/AC converters. Turbines are categorized as vertical and horizontal axis wind turbines, which can further be categorized into Fixed and Variable speed wind turbines.</p><h3>Types of Wind Turbines</h3><h4>Horizontal Axis Wind Turbines</h4><p>Horizontal Axis wind turbines are the most widely used wind turbines around the globe. As they have relatively higher power generation efficiency in regions with consistent wind conditions, and most wind power plants are situated in areas where we can have higher yields of power with as much as possible consistent winds throughout the year. Horizontal Axis wind turbines have their rotational axis parallel to the wind stream and ground, and they are usually set up high above the ground on tubular structures.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/350/1*S_U9d5dlWhs--N0VeM-rHA.png" /></figure><h4>Vertical Axis Wind Turbines</h4><p>Vertical Axis wind turbines have their fins placed vertically, and the rotational axis of vertical axis wind turbines is perpendicular to the ground. This property provides them the versatility of utilizing the wind from 360 degrees unlike horizontal axis wind turbines and makes them more appropriate for areas with relatively inconsistent wind conditions. Therefore, these are highly applicable in residential areas while on the contrary, horizontal axis wind turbines require more consistent wind conditions which is why they are mostly used in wind power plants.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/350/1*1Jt0b1jYQZ1ui1GwQZiHxw.png" /></figure><h4>Fixed Speed Wind Turbines</h4><p>Fixed speed wind turbines have their speed determined by the gear ratio and generator design according to the Grid Frequency while it is irrespective of the wind speed. These generators are made to work with the highest efficiency at a specific speed, and there is a significant decrease in efficiency when the speed of the wind varies from the specified value. Some of these generators can work efficiently around two different values of wind speed as they are built with two sets of windings. One set, with a higher number of poles, is utilized when the speed is low while the other with a lower number of poles is used when the wind speed is comparatively higher. These generators with two sets of windings provide higher overall efficiency than the former ones. Fixed speed wind turbines have lower costs and higher reliability than variable speed wind turbines.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/640/1*sLdwrZ9auuiHwulXByQLwQ.png" /></figure><h4>Variable Speed Wind Turbines</h4><p>Variable speed wind turbines are becoming increasingly common with the passage of time. Their speed varies with the changes in wind speed, and they always tend to achieve maximum efficiency with respect to the speed of the wind. This increases the complexity of the Wind turbine, and the generators are not directly coupled to the grid while they are connected through the Power Inverters. When power is generated through a variable speed turbine, its frequency varies, and therefore we need to insert power inverters between the generator and grids. Some of these Power inverters generate odd harmonics and consume reactive power. To eliminate harmonics from the system, harmonic filters are used while for reactive power compensation different methods can be used, including the addition of capacitor banks in the system. These factors increase the complexity and cost of the system. Therefore, Variable speed turbines are considered technologically advanced and involve high initial costs. But they provide a significant increase in the efficiency of the system which eventually leads to higher power yields, and relatively puts less mechanical stress on the Turbine itself.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/640/1*XSarFAH_4SRd-x_oveAS4w.png" /></figure><p>The below-mentioned figure shows, the power generated with respect to different Turbine speeds, the line ‘T’ represents fixed speed wind turbine while the curve ‘S’ represents Variable speed wind turbine. It can be observed that there is a significant variation in power generation by both the turbines, but the curve ‘S’ follows the maximum point of each speed curve, which means that the maximum possible output would be generated through the variable speed wind turbine at different wind speeds, while the constant speed wind turbine would only be generating maximum power at 9 m/s, while during all other wind speeds its output will be lesser than the <strong>maximum possible</strong> output power.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/640/1*1L9hREz6ZYKjmNh1gv8n2A.png" /></figure><h3>Factors Affecting the Stability of a Wind Integrated Power Grid</h3><p>For a successful operation of a power generation system and the utilities, it is compulsory to maintain the power quality of the system. Power quality must be maintained while attaining a complete balance between the power being generated, and the power being utilized by the consumer. Among all the considerations regarding the power quality, voltage variations and keeping a smooth sinusoidal wave are major concern that needs to be focused on throughout the power generation process. Now, we are going to see the factors that are to be looked upon in order to attain these outcomes.</p><ol><li>Voltage Instability and Flickering</li><li>Causes of Harmonics and their Effect on Power Quality</li><li>Reactive Power</li><li>Line impedance and Associated Grid Strength</li><li>Maintaining Generation Frequency</li></ol><blockquote><a href="https://www.allumiax.com/blog/integration-of-wind-energy-resources-with-conventional-grids#factors">C<strong>lick here</strong></a> to read detailed explanation of each factor affecting the stability of a wind integrated power grid.</blockquote><h3>How do Power System Studies Increase System Stability, and ensure Power Quality?</h3><p>Power System Design software enables us to Model these grids, and generation resources. A perfectly modeled system would help us simulate and analyze all kinds of scenarios that can take place during the operation of these Generation resources. Through these simulations, we can thoroughly study the response of our system, to all kinds of faults and Source/Load variations. <a href="https://www.allumiax.com/transient-stability-study">Transient stability analysis</a> would enable us to look for the response of each component at any given instant. We can study these responses and propose solutions to counter these effects. Moreover, such proposed remedies, like adding capacitor banks for the sake of voltage stability or increasing the generator’s torque to counter the overloading. These remedies can be further added to the system by modifying our model, and again we can analyze the results and how far are we able to counter such scenarios.</p><blockquote>Engineers at<strong> AllumiaX</strong> perform <a href="https://www.allumiax.com/engineering-studies">Power System Engineering Studies</a> in compliance with NEC, IEC and IEEE Standards. Get in touch with us <a href="https://www.allumiax.com/engineering-studies">here</a> and avail our services.</blockquote><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=e8f84734bd33" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Part 4: Electrical Engineering Queries Asked by Our Valuable Students]]></title>
            <link>https://allumiax.medium.com/part-4-electrical-engineering-queries-asked-by-our-valuable-students-b8439a6b9700?source=rss-ebc74255bd38------2</link>
            <guid isPermaLink="false">https://medium.com/p/b8439a6b9700</guid>
            <category><![CDATA[electrical-engineering]]></category>
            <category><![CDATA[q-and-a]]></category>
            <category><![CDATA[power-system]]></category>
            <category><![CDATA[frequently-asked-queries]]></category>
            <category><![CDATA[questions-answers]]></category>
            <dc:creator><![CDATA[AllumiaX Engineering]]></dc:creator>
            <pubDate>Fri, 29 Jul 2022 13:03:06 GMT</pubDate>
            <atom:updated>2022-07-29T13:03:06.764Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*6uWc5s_xpGxSCkMeg5a4wQ.png" /></figure><p><strong>Q1. Breakers that can decompose the unbalanced set of phasors to their respective sequence components are electronic breakers. Is there hardware inside the breaker that can do this and thus, correctly diagnose what kind of fault is on the system?</strong></p><p>Circuit breakers do not have the ability to decompose a set of unbalanced phasors to their respective sequence components and neither do they diagnose the type of fault. Circuit breakers only sense the current magnitude and then trip.<br>Electronic breakers, however, have a wide range of adjustable long time, short time and instantaneous (LSI) settings to provide better coordination and protection.</p><p><strong>Q2. Why when performing KVL on the negative and zero sequence networks, the initial voltage is zero? Is it because we are considering each network separately? I fail to see how math works if we consider the full faulted sequence network as one continuous loop/circuit since, by the logic, there would be two node voltages that are both zero despite not being physically connected?</strong></p><p>The negative and zero sequence circuits do not have a voltage source, or you can say that their pre-fault voltage is zero. This is because synchronous generator sources are designed to generate balanced voltages only i.e., positive sequence voltages.</p><p>Now, if we consider each network separately or consider a continuous loop. The initial voltage for negative and zero sequence parts will remain zero and will be represented by a short circuit</p><p><strong>Q3. Why are we not considering the transformer impedance when referring to HV side while calculating the sequence voltages?</strong></p><p>According to KVL, if transformer impedance is included that would give us the voltage after the transformer that is, the LV Side. But since we are calculating sequence voltages, immediately before the transformer that is why transformer impedance is excluded. Similarly refer to the Reactance diagram above, if fault occurs on point 2 that is the LV side of transformer, and its sequence voltage is reflected on HV side then 0.08j will not be included. As to your second point, the fault current value has been reflected on HV side both in terms of Magnitude and Phase angle (See part 4c). So, fault current value already accounts for transformer impedance.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/479/0*qTS0raK_2xQaEM9u.jpg" /></figure><p><strong>Q4. How much distance to be checked from fault distance (receiving from substation) if any fault occurred in EHV transmission lines?</strong></p><p>From what we have gathered from your question, it is about fault distance tracing from the fault point to the substation.</p><p>For faults that occur on transmission lines, we use “Distance Relay” that not only isolate the fault, but also give the estimate of fault location to restore the fault.</p><p>The relay issues tripping signal when fault is internal to its zone and restrains from the issuance of tripping signal when fault is external to its zone.</p><p>Figuratively,</p><ul><li>Z Relay &lt;= Z measured, Relay restrains from tripping</li><li>Z Relay &gt; Z measured, Relay issues tripping signal</li></ul><p>Consider the figure above, where fault occurs after the substation on EHV transmission line.</p><p>Since the fault is internal to the zone, the distance relay will issue tripping signal based on the condition mentioned above. As impedance is directly proportional to length of EHV Tx Line, so when the fault occurs at point A, voltage at the fault point decreases. Similarly, current increases exponentially and measured impedance becomes lower than relay set point impedance. This ensures that relay sees the transmission line shortened as before.</p><p><strong>Q5. How to do primary injection test to verify the CT polarity of the other circuits with a reference circuit in the substation (refer to page 351 to 354 of the book Practical Power System and Protective Relays Commissioning by Omar Salah Elsayed Atwa).</strong></p><p>There are several ways to test CT polarity and primary injection testing is certainly one of them, however not common. In my mind, primary injection testing would involve running current through the apparatus in which the CT is connected to. For example, if we a donut style CT measuring current through a cable, then we need to primary inject current into the cable. If we have a CT connected to the bushings of the transformer, then we need to inject current through the transformer. This can become expensive and very quick.</p><p>By far, the most common and practical method for CT Polarity testing is through a dedicated testing unit like the Megger MRCT or something equivalent. These units have special ways and algorithm to inject current on the CT secondary side (as opposed to primary injection) to determine the polarity and many other things. I would highly recommend down</p><p>The easiest way to determine CT polarity is through a Microprocessor-based protective relay and using a metering command. The equipment and apparatus are connected such that power flows from the source (utility) to the load (customers). And it is very typical to have CTs (Current Transformer) designed such that they see a positive current value on the relay during normal operating conditions. So, if have a CT polarity is swapped unintentionally, there is a very high chance that the metering command will show a negative value for normal power flow.</p><p>I know this is a lot of information without referencing the textbook but hopefully, it gives you context around CT polarity and testing methods to get more ahead with your work..</p><p>Megger MRCT: <a href="https://megger.com/current-transformer-excitation,-ratio-and-polarity-test-set-cter-91">https://megger.com/current-transformer-excitation,-ratio-and-polarity-test-set-cter-91</a></p><p><strong>Q6. Explain How non-SCADA coverage areas in power system operations could be supervised and controlled?</strong></p><p>Non-SCADA coverage areas can be supervised and controlled locally onsite with microprocessor protective relays and advanced controllers or personnel who can respond quickly.</p><p>You will get more value with SCADA connectivity (remote monitoring &amp; control) but if coverage is not available, then local supervision and control can still be performed by relays and advanced controllers like mentioned. Systems were monitored and controlled locally with a dedicated staff on property before the days of SCADA availability</p><p><strong>Q7. What is the secondary connection of the connected CT to the Star / delta power transformer?</strong></p><p>Diagram below shows the connections of the CT’s connected to transformer Star-Delta configuration (ignore the relay protection scheme). It is a normal practice to connect CTs in Star/Wye when the transformer is delta connected and CTs are Delta connected on the side where transformer is Y connected. Flipping the whole circuitry (including CT’s connection) horizontally will make it Star-Delta configuration.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/704/0*_9gYZcSPo7d4GFH9.jpg" /></figure><p><strong>Q8. How to wire a ct in delta for a tx secondary star winding for a differential relay?</strong></p><p>We would like you to have a look at the following snapshot taken from the Book “Practical Power System Protection” by Hawitson, pp. 218. It will give you a good idea of how to connect CTs in delta for a transformer’s star winding incorporated in differential protection scheme: .</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/485/0*6-GHG2iAE02Q_KTU.jpg" /></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=b8439a6b9700" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Part 3: Electrical Engineering Queries Asked by Our Valuable Students]]></title>
            <link>https://allumiax.medium.com/part-3-electrical-engineering-queries-asked-by-our-valuable-students-24d0db321cd0?source=rss-ebc74255bd38------2</link>
            <guid isPermaLink="false">https://medium.com/p/24d0db321cd0</guid>
            <category><![CDATA[frequently-asked-queries]]></category>
            <category><![CDATA[q-and-a]]></category>
            <category><![CDATA[questions-answers]]></category>
            <category><![CDATA[electrical-engineering]]></category>
            <category><![CDATA[power-system]]></category>
            <dc:creator><![CDATA[AllumiaX Engineering]]></dc:creator>
            <pubDate>Mon, 18 Jul 2022 13:01:22 GMT</pubDate>
            <atom:updated>2022-07-18T13:01:22.454Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*EXO87JRJhw3Z5AtmitzXNA.png" /></figure><p><strong>Q1.What is a Simo code and what is its function?</strong></p><p>SIMOCODE is the flexible, modular motor management system for low-voltage motors. It can easily and directly be connected to automation systems via PROFBUS or PROFINET. It combines in just one compact system all required protection, monitoring, safety, and control functions. The motor management system thus increases plant availability and allows significant savings to be made for installation, commissioning, operation, and maintenance of a system.</p><p><strong>Q2. What are some effects of open phase on the primary side of the transformer?</strong></p><p>Well, the answer to this question has many implications. To understand, the open phase condition in transformer is also called “single phasing”. When it occurs the currents and the voltages on the primary and the secondary side of the transformer highly depends on the following:<br>- Transformer Winding (Delta, Wye , Delta-Grounded etc.)<br>- Transformer Core construction<br>- Transformer Loading</p><p>Usually, the detection of the open-phase or single-phase condition is difficult to detect. In fact, the ground overcurrent or negative-sequence over current protection may not even detect the open phase condition due to the symmetry and balance of voltages and currents. To do that a detailed analysis of the open phase condition is done, and certain methodologies are implemented to identify and understand the effect of single phasing in a transformer.</p><p><strong>Q3. How to calculate Arc Current and Incident Energy below 600V?</strong></p><p>To provide safety to the people in the work environment Arc Flash studies are done. Appropriate procedures and personal protective equipment are then employed to minimize potential injuries.<br>Calculating the Arc Flash currents, and Incident Energy Levels have a step-by-step procedure. The following link will give you an in-depth look into the manual Arc Flash calculation according to the IEEE (Institute of Electrical and Electronics Engineers) Std. 1584 2002:<br><a href="https://myelectrical.com/notes/entryid/130/arc-flash-calculations-arc-flash-safety">https://myelectrical.com/notes/entryid/130/arc-flash-calculations-arc-flash-safety</a></p><p><strong>Q.4 What do you mean turn on maintenance switch?</strong></p><p>A Maintenance Switch is a toggle switch that is connected to the upstream protective device (relay or trip units) having the “Maintenance Mode” option. The maintenance mode makes use of a different trip setting that reduces the interruption time as compared to the standard instantaneous protection. When the switch is manually operated, the maintenance switch turns the upstream breaker function to “Maintenance Mode”. Under this setting, the protective device can improve the operating safety conditions by reducing the fault clearing time thus lowering the incident energy levels.</p><p>In summary, the maintenance mode or switch changes the settings, so it is sensitive to the change in current. Typically, the protective device (relay or breaker) operates on the lowest set instantaneous setting. If a fault were to occur, the protective device would operate fast without worrying about coordination. The speed of device operation reduces the incident energy levels significantly… and it enhanced safety… When personnel is working on a gear, the maintenance mode/switch would be “turned on” until the work is finished.</p><p><strong>Q5. When we consider arc flash is a hazard…. What level of hazard concerning arc flash to different voltage rating of power source? which is most fatal to deal with arc flash form D.C. or A.C.?</strong></p><p>To answer the first part of your question there are several factors and parameters considered when we can call Arc flash Hazard. For example, arc flash and incident energy levels produced by it differ according to the equipment, voltage at the bus it is type and equipment type. Similarly, when we talk about the power sources, we are referring to the voltage levels and current which are first use in calculating the Short-Circuit-Current and this value of the current is used to calculate the Arc Flash Hazards. For more details you can refer to the article on</p><p>IEEE Xplore: “IEEE Guide for the Specification of Scope and Deliverable Requirements for an Arc-Flash Hazard Calculation Study in Accordance with IEEE Std 1584(TM)”</p><p>and the link: <a href="https://allumiax.com/blog/ieee-1584-2018-in-depth-arc-flash-calculations-using-mathcad-express-etap-19-0-extensive-results-comparison?highlight=WyJoYW5kIl0=">https://allumiax.com/blog/ieee-1584-2018-in-depth-arc-flash-calculations-using-mathcad-express-etap-19-0-extensive-results-comparison?highlight=WyJoYW5kIl0=</a></p><p>Secondly, although our understanding of the Arc Flash has expanded in the recent years but most of the work is done on AC arc flash. Moreover, 2002 IEEE 1584 standard includes only AC arc flash hazards and no standards for the calculation of DC Arc flash. However, NFPA (National Fire Protection Association) 70E Arc Flash standards 2012 and 2015 extracted significant information from the paper: “Arc Flash Calculations for Exposures to DC Systems” and “DC-Arc Models and Incident-Energy Calculations”. It conclusively mentioned that the maximum possible power in a DC arc flash occurs when the arcing voltage is 50 percent of the system voltage. Also, since we must know the Arc Flash Energy levels which matters most, whether they occur into the AC or DC power system, but their method of calculation is surely different.</p><p><strong>Q6. How are relay settings calculated in real System like radial distribution system?</strong></p><p>Radial distribution and other distribution schemes are not usually considered in calculating the relay settings. Once the system distribution scheme is set up and relays are placed, relay settings are then configured according to the voltages, fault currents, loads, sources, and equipment protection. These settings have certain features which ensures desired selectivity, sensitivity, speed, and safety of the system.</p><p><strong>Q7. What do you know about protection relays, what are the main roles in a circuit or protection system?</strong></p><p>Relays, in general, are switches which can make or break the circuit to serve the crucial purpose of protecting power systems. They can be electronically or electromechanically operated. Advancement in relays have enable them to perform several tasks which include:</p><ul><li>sending trip signals to circuit breakers when required (e.g., in case of fault current)</li><li>acting as the brains of overcurrent, differential, earth fault, distance various other protection schemes</li><li>acts as an interface between high power loads and control circuitry</li><li>control and operate switches and other electromechanical devices remotely at large distances</li><li>programmable/ numerical relays incorporate microcontrollers which can be programmed to achieve the desired objective and level of protection</li></ul><p><strong>Q8. Is single derived from its three-phase system directly or per phase model of that three-phase system? Which one is right?</strong></p><p>Single Line Diagram is per phase representation of a three-phase system. It is a simplified notation of a three-phase system, that is why it is also known as One-Line Diagram.</p><p><strong>Q9. What is pre fault voltage in distance relay?</strong></p><p>Pre-fault voltage is the voltage of the system (particularly at the location of fault) when normal load current is flowing through it. The system voltage will be at the pre-fault level until any fault current starts to flow through it. The term ‘pre-fault voltage’ has no meaning in the context of distance relays. The general concept applies everywhere in the power systems.</p><p><strong>Q10. Scenario: 6x 11kV 6MVA generators each feeding a 11/33kV 6MVA transformers. Then paralleled up on a common bus. Question: can we lump generator and transformer values together in the form of MVA to simplify the circuit. i.e., a single generator and single transformer?</strong></p><p>Yes, we can lump the generators and transformers for circuit representation, but it also depends on the type of circuit or say its application.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=24d0db321cd0" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Part 2: Electrical Engineering Queries Asked by Our Valuable Students]]></title>
            <link>https://allumiax.medium.com/part-2-electrical-engineering-queries-asked-by-our-valuable-students-1592483c4111?source=rss-ebc74255bd38------2</link>
            <guid isPermaLink="false">https://medium.com/p/1592483c4111</guid>
            <category><![CDATA[frequently-asked-queries]]></category>
            <category><![CDATA[power-system]]></category>
            <category><![CDATA[q-and-a]]></category>
            <category><![CDATA[questions-answers]]></category>
            <category><![CDATA[electrical-engineering]]></category>
            <dc:creator><![CDATA[AllumiaX Engineering]]></dc:creator>
            <pubDate>Wed, 06 Jul 2022 12:33:53 GMT</pubDate>
            <atom:updated>2022-07-06T12:33:53.278Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*9aVBiPGWh7R6MkiP8iLtSA.png" /></figure><p><strong>Q1. How will we calculate short circuit current in a specific area instead of converting all given circuit in an equivalent circuit and finally applying Ohms Law on it?</strong></p><p>Just remove all the circuits after the point at which you want to calculate the short circuit current and just attach Zload to it. Then solve it using a per-unit system and apply Ohms Law in the end.</p><p><strong>Q2. If in LV (Low Voltage) side any one phase grounded, so what will be the voltage &amp; current in HV (High Voltage) &amp; LV side in delta star 11 transformer.</strong></p><p><strong>LV Side:</strong><br>When a line to ground fault occurs on one line on the LV side then all current will flow from the faulty line. Other two lines will have no current passing through them. Similarly, the line which is faulted will have zero volts on it while having rated voltage on other two lines.</p><p><strong>HV Side:</strong><br>Transformer will feed its maximum fault current which will eventually saturate the transformer with a slight decrease in the rated HV voltage.</p><p><strong>Q3. In the window type current transformer, how does the primary conductor passing through CT, make it ‘one turn’.</strong></p><p>In literal terms, the conductor passing through the window type CT does not have any ‘turns’. However, the term ‘turns’ is extensively used in electrical engineering literature to refer to the number of times the current must travel through a similarly shaped part of the circuit. See the image in the link below which shows a solenoid, where there are 6 ‘turns’ — or say ‘identical portions’ of the circuit, so in a circuit where there are no turns, there will only be one ‘identical portion’ for the current to pass through.</p><p><a href="https://circuitdigest.com/sites/default/files/field/image/What-is-Solenoid.png">https://circuitdigest.com/sites/default/files/field/image/What-is-Solenoid.png</a></p><p>The term ‘turns’ has been adopted for use in several equations, one of the most famous being the transformation ratio of a transformer. To keep consistency with the existing literature, a single straight conductor is called having ‘one turn’.</p><p><strong>Q4. How to bank one 167kva 3phase 280V transformer in 4wires?</strong></p><p>A single 3-phase transformer can be connected in Wye configuration to get a 4-wire system, 3 of the wires will be for each of the 3 phases, while the 4th wire will be used for a neutral connection.</p><p><strong>Q5. If a burden of a CT is reduced, then what happens on primary current Ip after some time?</strong></p><p>A Burden is an estimation of load connected on the secondary side of CT (measured in VA). Ideally, a CT should reflect the current on secondary side as accurately as possible from the current flowing in the primary side.<br>However, this does not happen so because of the presence of magnetization current and other factors that generates an error in the reflection of current on secondary side. Nonetheless, an effort is made to make this error minimal. CT measurement is close to maximum accuracy when the actual CT burden is equal to the rated CT burden.<br>The CT burden influences the accuracy of the CT measured value on the secondary side. Higher burden selection against the required burden results in CT measurement inaccuracy. For instance, if a CT designed for 15 VA burden is operated for 5 VA, there will be a higher error in its measurement even when the CT is operating at its rated current.<br>As to answer your question, the primary current of the CT is independent of the CT burden on the secondary side. Since the primary current depends on the load current flowing through the line.</p><p><strong>Q6. Can power flow in a delta connected power line if two phases are lost (Open)?</strong></p><p>It depends on which two HV Lines are lost. You will have to trace through the transformer connections to see if there are any HV windings that are energized. If there is any HV energized winding, then you can expect power to flow into the LV (Low Voltage) winding.</p><p><strong>Q7. How choose the type of curve of relays?</strong></p><p>To balance the right amount of overcurrent protection against optimal machine operation, we need different trip curves. Selecting a circuit breaker with a trip curve that trips too soon can result in nuisance tripping. Choosing a circuit breaker that trips too late can result in catastrophic damage to machine and cables.</p><p>The X axis represents a multiple of the operating current of the circuit breaker and The Y axis represents the tripping time.</p><p>The three major components of the Trip Curve are:</p><ol><li>Thermal Trip Curve. This is the trip curve for the bi-metallic strip, which is designed for slower overcurrent to allow for in rush/startup, as described above.</li><li>Magnetic Trip Curve. This is the trip curve for the coil or solenoid. It is designed to react quickly to large overcurrent, such as a short circuit condition.</li><li>The Ideal Trip Curve. This curve shows what the desired trip curve for the bi-metallic strip is. Because of the organic nature of the bi-metallic strip, and changing ambient conditions, it is difficult to precisely predict the exact tripping point.</li></ol><p>Trip curves represent the predicted behavior of a circuit breaker in ambient room temperature. This means when the bimetallic strip is within the specified ambient operating temperature for the breaker. If the breaker has experienced a recent thermal trip and has not cooled down to the ambient temperature, it may trip sooner.</p><p>Trip Curves predict the behavior of circuit protection devices in both slower, smaller overcurrent conditions, and larger, faster over current conditions. Choosing the correct trip curve for your application provides reliable circuit protection, while limiting nuisance or false trips.</p><p><strong>Q8. In a 220/132kV Three phase combined winding (Single Equipment) trafo, one of the LV sides fails so what will be the effect to the lv current of remaining phases? Also, will the trafo can be operated with 2phases in LV side?</strong></p><p>Perspective, it receives abnormal voltages and currents from two phases but little (or even zero) from the phase that was lost on the HV side.</p><p><strong>Q9. What is Zs in a system where fault level calculations are done. Input value, Zs = V/Ifault.</strong></p><p>We can define Zs as the maximum impedance due to a single line to ground Earth Fault (also called Earth Fault Loop Impedance). For the maximum fault current, I(fault) and nominal system voltage V, Zs can be calculated by the formula Zs = V/Ifault. Zs is calculated and used in Fault Analysis in power systems. Also, it can be calculated from the time-current curve of the protective device during protection coordination.</p><p><strong>Q10. At (D/Y) transformer, If short circuit in one phase ia (earth fault) at secondary of transformer about 2000 amp, what the effect on primary (D)?</strong></p><p>Typically for any an earth fault that would occur on the LV (Wye) side of the transformer, the impedance reduces and the current on the secondary side will increase causing the current in the primary side (Delta) of the transformer to be increased due to the cascaded effect and the current feeding through the upstream devices will also increase. The overcurrent protection devices will come into play to mitigate the effect of the fault.</p><p>In case you require a more specific response you can choose to specify the size in KVA and %Z of the transformer as well.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=1592483c4111" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Part6— Electrical Engineering Interview Questions & Answers (MCQs)]]></title>
            <link>https://allumiax.medium.com/part6-electrical-engineering-interview-questions-answers-mcqs-a246a7ec0568?source=rss-ebc74255bd38------2</link>
            <guid isPermaLink="false">https://medium.com/p/a246a7ec0568</guid>
            <category><![CDATA[power-flow-equations]]></category>
            <category><![CDATA[ybus-matrix]]></category>
            <category><![CDATA[power-flow-analysis]]></category>
            <category><![CDATA[load-flow-analysis]]></category>
            <category><![CDATA[admittance]]></category>
            <dc:creator><![CDATA[AllumiaX Engineering]]></dc:creator>
            <pubDate>Tue, 07 Jun 2022 13:03:16 GMT</pubDate>
            <atom:updated>2022-06-07T13:03:16.116Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*9AsDjL4euiTs0PvDQ6nMrw.jpeg" /></figure><p>Q.1 What is Admittance?</p><p>(a) It is equal to the Impedance.</p><p>(b) It is the square root of Impedance</p><p>© It is the inverse of Impedance</p><p><strong>Answer:</strong> © It is the inverse of Impedance ✔</p><p><strong>Explanation: </strong>(Z = 1/Y)</p><p>Q.2 Which equation represents the admittance?</p><p>(a) Y=R+jX</p><p>(b) Y=G+jB</p><p>© Y=G+jX</p><p><strong>Answer:</strong> (b) Y=G+jB ✔</p><p>Q.3 What is the inverse of resistance?</p><p>(a) Susceptance</p><p>(b) Reactance</p><p>© Conductance</p><p><strong>Answer:</strong> © Conductance ✔</p><p><strong>Explanation: </strong>(B=1/R=conductance)</p><p>Q.4 If we have the voltage at bus 1 is V₁ and voltage at bus 2 is V₂ and admittance between both buses is Y. what is the formula for finding current flowing between both buses?</p><p>(a) I = V₁₂ * Y</p><p>(b) I = V₁₂ / Y</p><p>© I = Y / V₁₂</p><p><strong>Answer:</strong> (a) I = V₁₂ * Y ✔</p><p>Q.5 If the voltage at bus 1 is Vᵢ and then we have multiple paths and current will flow from all paths. What will be the formula for finding total current which is also at bus 1? (n=total no of paths)</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/343/1*DJoPBInG-4_oAr4iNUjmCw.png" /></figure><p>(a) Iᵢ=∑ⁿ ⱼ₌₁ Yᵢⱼ / Vⱼ</p><p>(b) Iᵢ=∑ⁿ ⱼ₌₁Yᵢⱼ*Vⱼ</p><p><strong>Answer</strong>: (b) Iᵢ=∑ⁿ ⱼ₌₁ Yᵢⱼ*Vⱼ ✔</p><p>Q.6 The voltage at bus 1 is Vᵢ∠δᵢ and voltage at bus 2 is Vⱼ∠δⱼ, If the total current passing from bus 1 is Iᵢ which is the summation of all current passing through bus 1. What will be the total apparent power at bus 1? <br>(Iᵢ=∑ⁿ ⱼ₌₁ Yᵢⱼ ∗ Vⱼ ∠𝜃ᵢⱼ+𝛿ⱼ)</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/339/1*bC5SnbKeb2w3WSmD8GnKQw.png" /></figure><ol><li>Sᵢ=∑ⁿ ⱼ₌₁ Vᵢ ∗ Yᵢⱼ ∗ Vⱼ∠δⱼ−θᵢⱼ−δᵢ</li><li>Sᵢ=∑ⁿ ⱼ₌₁ Vᵢ ∗ Yᵢⱼ ∗ Vⱼ∠δᵢ+θᵢⱼ+δⱼ</li><li>Sᵢ=∑ⁿ ⱼ₌₁ Vᵢ ∗ Yᵢⱼ ∗ Vⱼ∠δᵢ−θᵢⱼ−δⱼ</li></ol><p><strong>Answer:</strong> Sᵢ=∑ⁿ ⱼ₌₁ Vᵢ ∗ Yᵢⱼ ∗ Vⱼ∠δᵢ−θᵢⱼ−δⱼ ✔</p><p><strong>Explanation: </strong>S = VI* = Vᵢ ∗ Iᵢ* = Vᵢ∠δᵢ∑ⁿ ⱼ₌₁ Yᵢⱼ ∗ Vⱼ∠−θᵢⱼ−δⱼ, when we have conjugate on any parameter which is due to current when we find our apparent power then the angle of that parameter is inverted.</p><p>Q.7 If the real power entering at any bus is Pɢ and power leaving from that bus is Pʟ. How we can find the net real power at that bus? <br>Pʙ=Net real power at that bus</p><p>(a) Pʙ = Pɢ = Pʟ</p><p>(b) Pʙ = Pɢ — Pʟ</p><p>© Pʙ = Pɢ + Pʟ</p><p><strong>Answer</strong>: (b) Pʙ = Pɢ — Pʟ ✔</p><p><strong>Explanation: </strong>The net power at any bus is the difference of power entering at that bus and the power leaving from that bus.</p><p>Q.8 Why do we use the Newton Raphson Method in power systems?</p><p>(a) For finding the impedance in a power system</p><p>(b) For solving power flow equations</p><p>© None of the above</p><p><strong>Answer</strong>: (b) For solving power flow equations ✔</p><p>Q.9 Shunt admittance in transmission lines is also referred to as..?</p><p>(a) Line Charging Inductance</p><p>(b) Line Charging Conductance</p><p>© Line Charging Capacitance</p><p><strong>Answer</strong>: © Line Charging Capacitance ✔</p><p>Q.10 If impedance between two buses is j0.05 Ω. What will be admittance between these two buses?</p><p>(a) — j20 Ω</p><p>(b) j20 S</p><p>© — j20 S</p><p><strong>Answer</strong>: © — j20 S ✔</p><p><strong>Explanation: </strong>Y = 1/Z = 1/j0.05 = — j20 Siemens</p><p>Q.11 In the Y Bus matrix, what is meant by Y₂₃?</p><p>(a) Impedance between Bus 2 and Bus 3</p><p>(b) Admittance between Bus 3 and Bus 2</p><p>© Admittance between Bus 2 and Bus 3</p><p><strong>Answer</strong>: © Admittance between Bus 2 and Bus 3 ✔</p><p>Q.12 For a <strong>Y Bus Matrix</strong>, What will be the value of Y₂₃ ? (Given values are admittances)</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/283/1*hnP74PsdnDKDrscOaB1hBg.png" /></figure><p>(a) — j0.25</p><p>(b) j0.3</p><p>© — j0.3</p><p><strong>Answer</strong>: (b) j0.3 ✔</p><p><strong>Explanation: </strong>Y₂₃= — 1( — j0.3) = j0.3</p><p>Q.13 What admittance will we take for diagonal admittance in the Y Bus matrix?</p><p>(a) Diagonal admittance is equal to 1 for all buses</p><p>(b) Diagonal admittance is the sum of all admittances connected to that bus</p><p>© Diagonal admittance is the sum of all admittances connected through all buses</p><p><strong>Answer</strong>: (b) Diagonal admittance is the sum of all admittances connected to that bus ✔</p><p>Q.14 For a Y Bus Matrix, What will be the value of Y₁₁? (Given values are admittances)</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/283/1*hnP74PsdnDKDrscOaB1hBg.png" /></figure><p>(a) — j0.7375</p><p>(b) j0.0125</p><p>© j0.7375</p><p><strong>Answer</strong>: (a) — j0.7375 ✔</p><p><strong>Explanation: </strong>(Y₁₁= — j0.5 — j0.25 + j0.0125 = — j0.7375)</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=a246a7ec0568" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Maximum Demand Indicator (MDI)]]></title>
            <link>https://allumiax.medium.com/maximum-demand-indicator-mdi-e5d1ca3af168?source=rss-ebc74255bd38------2</link>
            <guid isPermaLink="false">https://medium.com/p/e5d1ca3af168</guid>
            <category><![CDATA[capacitor]]></category>
            <category><![CDATA[electricity-bills]]></category>
            <category><![CDATA[energy]]></category>
            <category><![CDATA[load-factor]]></category>
            <category><![CDATA[power-factor]]></category>
            <dc:creator><![CDATA[AllumiaX Engineering]]></dc:creator>
            <pubDate>Fri, 03 Jun 2022 07:42:31 GMT</pubDate>
            <atom:updated>2022-12-02T10:54:40.008Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="New Blog: Maximum Demand Indicator" src="https://cdn-images-1.medium.com/max/1024/1*8pFIFiorQ9iJQyFUW2nUPw.png" /></figure><p>It is essential for any power utility to provide sufficient energy enough for all the loads connected to the system. To achieve this, the generation and distribution system should be equipped with instruments to determine the maximum demand of consumers at all times. This can be done by the instrument called Maximum Demand Indicator (MDI). This blog describes the applications, pros and cons of different types of MDIs and the significance of calculating maximum demand.</p><h3>Maximum Demand</h3><p><em>The greatest power demanded by load on the power station during a given time period is called maximum demand.</em></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/431/1*OAYy1SEriaURRfr-Br0RPg.png" /></figure><p>Where,</p><ul><li>Load factor is the ratio of energy consumed in a given time period to the maximum demand in the specified time period. When the load factor value is low, then it indicates value of maximum demand to be very high. To improve load factor, electrical load operating at the peak time of the day can be shifted to off-peak hours.</li><li>Average Load is the average of loads that occurred in a given time period also known as average demand.</li></ul><figure><img alt="" src="https://cdn-images-1.medium.com/max/649/1*0Inis8W0aPtPB3Dad4JahQ.png" /></figure><p>The demand charge for a given month is determined by the given formula:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/736/1*hIoUZpyDREoGV3QCUAQozQ.png" /></figure><h3>Stay Sharp &amp; Join our Mailing List!</h3><p>Our surveys show that 90% of the people who join our blog have found the content valuable! <a href="http://bit.ly/3VBmUhn">Join today</a></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/399/0*iS3XZRCc18NP67Cx.png" /><figcaption><a href="http://bit.ly/3VBmUhn">Signup Now</a></figcaption></figure><h4>Significance of Maximum Demand:</h4><p>Electricity billing structure by the utilities is usually composed of a two-part tariff structure, one part depends on the actual energy drawn (kWh), while other depends on the power demand (kVA or kW) during the billing cycle. Electric power suppliers charge commercial and industrial consumers such as industry, office buildings, hospitals etc. on the basis of maximum demand and total unit consumption. However, the residential customers are charged just for the “actual” energy (kW) used and not the “total” energy (kVA) supplied. With the increasing trends of energy conservation and cost saving, it is important for any consumer to understand the electricity tariffs.</p><p>Generally, utilities impose different demand charges for Peak and Off-Peak hour based on electricity billing structure. Let us explore the calculation of demand charges by an example.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/782/1*GtHkIFOlYXIsZdC0N7Kezw.png" /></figure><p>Customer’s maximum demand during peak hours = <strong>400 kW</strong></p><p>Maximum demand during off-peak hours = <strong>150 kW</strong></p><p>Demand charges would be calculated as:</p><p>On-peak Demand: 400kW * 15.78 Cents = <strong>6312 Cents</strong></p><p>Off-peak Demand: 150kW * 13.07 Cents = <strong>1960.5 Cents</strong></p><p>Total Demand Charges for the month = On-peak Demand + Off-peak Demand= 6312+1960.5</p><p>Total Demand Charges for the month = <strong>8272.5 Cents</strong> = <strong>$ 82.725</strong></p><p>Now assume another case in which peak demand is reduced during both on and off-peak hours:</p><p>Customer’s maximum demand during peak hours = <strong>150 kW.</strong></p><p>Maximum demand during off-peak hours = <strong>300 kW.</strong></p><p>Demand charges would be calculated as:</p><p>On-peak Demand: 150kW * 15.78 Cents = <strong>2367 Cents</strong></p><p>Off-peak Demand: 300kW * Cents. 13.07 = <strong>3921 Cents</strong></p><p>Total Demand Charges for the month = On-peak Demand + Off-peak Demand= 2367+3921</p><p>Total Demand Charges for the month = <strong>6228 Cents</strong> = <strong>$ 62.28</strong></p><p>In the above example, we can observe a significant reduction in utility bill cost. Hence, we can conclude that when maximum demand is increased, higher will be the charges. There is need to reduce our maximum demand which is indicated by maximum demand indicator. So, maximum demand indicator holds great significance for utilities and consumers.</p><p>The importance of maximum demand lies in the fact that it helps in determining the installed capacity of the station and cost of installation. Higher the value of maximum demand on the station, greater will be the size and cost of installation. As the station capacity is optimized to meet the maximum demand. Now, low maximum demand means low capacity of the plant which, therefore, reduces the cost of the plant. Further, the tax charge and clerical staff depends upon the size of the plant and consequently, depend upon maximum demand.</p><h3>Maximum Demand Indicator:</h3><p>Maximum Demand indicator is a device which records the maximum power used by the consumer at intervals. The indicator should only measure the base and peak load value not the high current values due to sudden short circuit or inrush current.</p><h4>Types of Maximum Demand Indicator:</h4><p>Following are the Types of Maximum Demand Indicators:</p><ol><li>Wright Maximum Demand Indicator</li><li>Merz-Price Demand Indicator</li></ol><h4>Wright Maximum Demand Indicator:</h4><p>Wright MDI is basically a thermal indicator operated by current. It works on the principle of differential thermometer. It is made up of U-shaped glass tube with two bulbs at upper ends of tube. The left side bulb consists of an air and metallic strip around it which is then connected with the load circuit in series. Beneath the right-side bulb, a scale is fitted along with a narrow bore Index tube. The main U-shaped tube is filled with dilute sulphuric acid, having low co-efficient of thermal expansion at low temperature. The traps in each limb prevents the movement of air from one bulb to the other.</p><p>The air inside the bulb expands when the load current flows through the strip. This expansion causes the indicator liquid of right-hand bulb to spill over into the index tube. The expansion of liquid highly depends on the magnitude of load current across the strip of the indicator. Thus, higher the magnitude of load current, the greater will be the expansion of liquid, and as a consequence, higher will be the quantity of liquid overflowing into the index tube. Now, the overflow of liquid will happen only when the load current through the strip exceeds the previous load current value.</p><p>For such indicator, time lag must be incorporated to prevent indication of peak demand of short duration. This time delay is increased by placing cast iron cylinder between bub and metallic strip (heater coil).</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/500/1*gp4OryUR8IcPn-kFWuG7ag.png" /></figure><blockquote><a href="https://www.allumiax.com/blog/maximum-demand-indicator#wrightApplications"><strong>Click here</strong></a> to know about the Applications, Advantages and Disadvantages of Wright Maximum Demand Indicator.</blockquote><h4>Merz Price Indicator:</h4><p>Merz Price Indicator is integrated with the energy meter which measures total energy consumed at particular time interval. The indicator records the maximum demand through a complex speed dial mechanism. Pointer connected to Merz demand indicator is driven by disc mechanism of energy meter using some gearing mechanism. Then, pin moves the dial forward which indicates the total power consumed at particular interval. For the next time interval, pointer will record the total power consumed by the load. The pin will move forward only when energy used by the load exceeds the previous recorded value. The indicator consists of cam and Bell crack mechanism, used to reset the pointer at initial position.</p><p>Merz Price indicator lies under the category of Average Demand Indicator as it shows the maximum value of the load averaged over equal time interval. The mathematical expression to calculate Average Maximum Demand is given as:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/562/1*6FRSI_AZW6MnYo-2YX7CHw.png" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/500/1*Y2S7IkAIszPtDM0qsKYPHg.png" /></figure><blockquote><a href="https://www.allumiax.com/blog/maximum-demand-indicator#merzpriceAdvantages"><strong>Click here</strong></a> to know about the Advantages and Disadvantages of Merz-Price Indicator.</blockquote><h3>Maximum Demand Penalty:</h3><p>Once consumer specify the MD (Maximum Demand) needed during the month to utility, electric power supply company setup the generating station based on MD by load side. In an electrical system, an increase in the demand for electricity by more diverse end user leads to shortfall in capacity to meet demand. To keep up with energy demands, the construction of new generation power plants are costly as well as a long wait prospective. So, utility imposes a penalty on consumer if MD value during the month is higher than the contracted demand. This penalty is accounted in their electricity bill and is termed as MD Penalty.</p><h4>Ways to avoid MD Penalty:</h4><p>MD penalties are incurred by utility because of exceeding the contracted power can be reduced by practicing the following methods:</p><ul><li>Power Factor Improvement</li><li>Peak Shaving of Load Curves</li><li>Load Management using Time of Use (TOU) Method</li></ul><blockquote><a href="https://www.allumiax.com/blog/maximum-demand-indicator#mdPenalty"><strong>Click here</strong></a> to read each method in detail.</blockquote><p>As MD contributes to the considerable portion of the electricity bill cycling, to effectively control the maximum demand during the month, there is a real need of integrating Power Demand Controller. The gap of supply and demand have compelled power engineers to develop techniques for Demand Side Management (DSM) and Load Management such that utility and consumers can make the most of electric energy. MD controllers based on novel techniques have been implemented and proved that managing loads on peak hours increases the reliability of power system by lowering the power cuts.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=e5d1ca3af168" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Ring Main Unit in Electrical Distribution System]]></title>
            <link>https://allumiax.medium.com/ring-main-unit-in-electrical-distribution-system-67d6a1e154ea?source=rss-ebc74255bd38------2</link>
            <guid isPermaLink="false">https://medium.com/p/67d6a1e154ea</guid>
            <category><![CDATA[ringmainunit]]></category>
            <category><![CDATA[electrical-distribution]]></category>
            <category><![CDATA[power-distribution]]></category>
            <category><![CDATA[circuit-breaker]]></category>
            <category><![CDATA[relay]]></category>
            <dc:creator><![CDATA[AllumiaX Engineering]]></dc:creator>
            <pubDate>Thu, 21 Apr 2022 05:50:18 GMT</pubDate>
            <atom:updated>2022-12-02T11:01:22.170Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*-PXYo4sg8jQ5m0J6oQkLCA.png" /></figure><h3>What is a Ring Main Unit?</h3><p>In an electrical power distribution system, a ring main unit (RMU) is a factory assembled, metal enclosed set of switchgear at the load connection points of a ring-type distribution network. It contains different types of switches for different purposes for example some switches connect with load, some feed a distribution transformer etc.</p><p>The metal enclosed unit connects to the transformer either through a bus throat of standardized dimensions or through cables and is usually installed outdoors. Ring main cables enter and leave the cabinet. This type of switchgear is used for medium-voltage power distribution.</p><p>RMU is an extensible and non-extensible ring main unit for the secondary distribution network. RMU can be supplied in various configurations suitable for most switching applications in 24 kV distribution networks. RMU is a completely sealed system with a stainless-steel tank, gas tight metal enclosure, containing all the live parts, switching-disconnector, earth switch, fuse switch, the circuit breaker.</p><p>This blog describes the importance of Ring Main Unit in power distribution and its comparison with other types of switch gear and in which type of power distribution application using ring main unit can be cost effective.</p><h3>Stay Sharp &amp; Join our Mailing List!</h3><p>Our surveys show that 90% of the people who join our blog have found the content valuable! <a href="http://bit.ly/3VBmUhn">Join today</a></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/399/0*fGHsSYfqJMORPtWu.png" /><figcaption><a href="http://bit.ly/3VBmUhn">Signup Now</a></figcaption></figure><h3>Power Distribution System</h3><p>Power system is classified into three main portions which include:</p><ul><li>Generation</li><li>Transmission</li><li>Distribution</li></ul><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*95r_BiUKlJXNjvslFnLt_w.png" /></figure><p>The area between substation that are fed through transmission up till user meter are part of distribution system. It consists of:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/782/1*hScVM39wSVu67Tln0nN4HQ.png" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/400/1*CWv0cgJHygqXjx2yoVAIGg.png" /><figcaption>Fig 1: The figure shows an example of substation, feeder, distributor and service main connection. Here AD, CD, BC, BA shows distributor</figcaption></figure><h3>Connection Schemes in Distribution Scheme</h3><p>Connection schemes shows the arrangement of feeder, distributor, and service main.</p><p>According to connection scheme, distribution system can be classified into three main types:</p><ol><li>Radial System Schematic</li><li>Ring Main System Schematic</li><li>Interconnected System Schematic</li></ol><blockquote><a href="https://www.allumiax.com/blog/ring-main-unit-in-electrical-distribution-system#distribution-schemes"><strong>Click here</strong></a><strong> </strong>to read the detailed explanation of each type of distribution system.</blockquote><h3>Ring Main Unit</h3><h4>Connections in a Distribution Network</h4><p>Ring main unit are used in ring main network for the purpose of connecting feeders to form a loop and monitors fault or any malfunction at feeders and distribution transformer end and make sure that power is provided to the utility without any disturbance and with least possible voltage drop.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*gv0Bc4fm7nMxd-Z_kT0NPw.png" /><figcaption>Fig 2: Connection of RMU forming a loop</figcaption></figure><h4>Ring Main Unit Design</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/756/1*x4gG5Wjqt2uzJKwqRa9aYw.png" /></figure><h4>Features</h4><p>Some features of RMU switch gears are as follows:</p><ul><li>Small in size and compact insulation filled sealed switch gear.</li><li>Used for 11KV/33KV systems. Normally rated for 630 A and 21KA interrupting rating.</li><li>Comprises of three types of insulation: oil, air and SF6 gas. SF6 gas insulation is widely used.</li><li>Normally has 2 incoming and one outgoing and vice versa.</li><li>Have separate protective and measuring devices.</li><li>Can be used in indoor and outdoor</li><li>Reduce hazards related to fire</li></ul><h4>Modular Compartmentalized Design</h4><p>Each RMU consist of at least 3 section/ modular compartment</p><ol><li>Incoming feeder</li><li>Outgoing feeder</li><li>Bus coupler</li></ol><p>Depending on type of distribution scheme, section can also increase in odd number form like 5, 7, 9 and even more in each unit. A 5 section RMU may consist of two incoming and outgoing feeder each and a bus coupler. Similarly, a 7 section RMU may consist of three incoming and outgoing feeder each and a bus coupler and so on.</p><h4>Construction</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/400/1*-xUXPC0ylVyfcFwYOe4ShQ.png" /></figure><ul><li>Cable Test Compartment</li><li>Gas Tank</li><li>Interlocking Latch for Cable Test Compartment</li><li>Padlocking Facilities for Load Break Switch</li><li>Load Break Switch Operating Mechanism</li><li>Padlocking Facilities for Earthing Switch</li><li>Vacuum Circuit Breaker</li><li>Ring Switch Cable Compartment</li><li>MV Cable Fixing Support</li><li>Tee-Off Switch Cable Compartment</li><li>Voltage Presence Indicator</li><li>Switch-disconnector Operation (Motor Optional*)</li><li>Operation Counter</li><li>Circuit Breaker Operation (Motor Optional*)</li><li>Operating Latch for Vacuum Circuit Breaker</li><li>Protection Relay</li><li>Lifting Lugs</li><li>Padlocking Facilities for Vacuum Circuit Breaker</li><li>Vacuum Circuit Breaker Operating Mechanism</li><li>Gas Pressure Indicator</li></ul><h3>Components</h3><p>Following are the main components used in ring main unit:</p><h4>Load Break Switch</h4><p>Load break switch or isolators are used for breaking contact of any feeder isolated due to the reason of fault or maintenance purpose with the load. There is an earth protection switch also available which is used when the feeder is de-energize due to fault condition. Standard followed for load break switch ‘IEC 265/BS 3804’.</p><h4>Circuit Breaker</h4><p>Circuit breaker can be used:</p><ul><li>Either for switching</li><li>Or if used as medium voltage protection then it will be issued with trip signal using relays.</li></ul><p>Standard for circuit breaker involves ‘IEC 56/BS 5311/IS 13118’.</p><blockquote>👉🏼 We also have written a blog titled <a href="https://www.allumiax.com/blog/selecting-the-right-circuit-breaker-and-its-type"><strong>Selecting the Right Circuit Breaker and Its Type</strong></a>. Have a look at it to grab more information about circuit breakers.</blockquote><h4>CT/PT</h4><p>For the purpose of monitoring current and voltages, current and potential transformer are used. CTs can be used for giving the input of current to relays which then senses a normal or fault condition according to the current.</p><h4>Numerical Relays</h4><p>Relays used for over current, under and over voltage protection.</p><h4>Cable Testing Compartment</h4><p>Ring main units offer a safe way of cable testing from the easily accessible cable testing compartment on the front panel. Operators can simply conduct the cable testing through plug-in type connectors after opening the cover. The cable test cover is safely interlocked and cannot be opened unless the load break switch is earthed.</p><h4>Gas Pressure Indicator</h4><p>Gas density is an important operating parameter for SF6 insulated MV equipment. If the required gas density is not sufficient, safe operation cannot be guaranteed. On ring main units, a gas pressure indicator is fitted to the tank for providing a reliable warning indication against low gas levels. The gas pressure indicator has sections to show the minimum pressure for safe operation.</p><h4>Voltage Presence Indication System</h4><p>All ring main units are integrated with a voltage presence indication system. A voltage signal comes from the VPIS through the voltage divider positioned into the cable entrance of bushings. The VPIS can be used to check whether a voltage is present across the cables.</p><h4>SCADA System</h4><p>SCADA systems are used for the trip settings of fault current, over loading and time current curves of the protective devices. There is a connection available for C.T which is used for monitoring purpose. Also there is a communication cable available.</p><p>Standard followed for monitoring and control system involves ‘IEC 801’</p><blockquote>👉🏼 We previously wrote a blog about <a href="https://www.allumiax.com/blog/scada-and-its-application-in-electrical-power-systems"><strong>SCADA and Its Application in Electrical Power Systems</strong></a>. If this finds your interest, check it out and let us know what you think.</blockquote><h3>RMU Operation in case of a Fault</h3><p>For example: if a fault occurs at feeder 1 side then first of all the relay will issue a trip signal at load side circuit breaker to open first and then both isolators disconnect. Now for energizing the load again isolator 2 first connects and then breaker is closed.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*kdDxaxzzCJPH7sWLLdRJ2g.png" /><figcaption>Fig 3: Connection of two feeders with load or distributor in RMU</figcaption></figure><p>The earth switch is available for the protection of human from getting electrical shock while maintenance.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*PiKtxeiEbX4Jx2nHlvifQg.png" /><figcaption>Fig 4: RMU with earth switch</figcaption></figure><h3>Advantages and Disadvantages of RMU</h3><h4>Advantages of RMU</h4><ul><li>Cost and Time Saving</li><li>Less Maintenance Requirement</li><li>Small Size and Compact Design</li><li>Safe and Reliable Operation</li><li>Smart Skills</li></ul><blockquote><a href="https://www.allumiax.com/blog/ring-main-unit-in-electrical-distribution-system#advantages-of-RMU"><strong>Click here</strong></a> to read the details of each advantage of RMU.</blockquote><h4>Disadvantages of RMU</h4><ul><li>Have high capital cost.</li><li>It is less robust as compared to other switch gears. It may have an operation cycle of 2000 which is less as compared to other switch gear.</li><li>Can fail due to leakage of SF6 gas and with moisture entry.</li></ul><h3>Application in Industry</h3><p>As ring main unit are very high in cost due to the use of smart monitoring and SF6 circuit breaker and reliable protective device. They can be cost effective for the application where load requires a reliable and continuous power supply which may include:</p><ul><li>Industries</li><li>Solar panel</li><li>Wind turbine</li><li>Airports, hospital and metro etc.</li></ul><h4>Typical Position of RMU in Network</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/474/1*FVVJC0Cezw4H3ZM2JCEiEA.png" /></figure><p>Above figure explains the location of RMU in a Power system. It can be distributed in 3 levels as shown above. Here the core setting is that every load is fed by 2 sources. In case one source fails other one is connected to load with the help of RMU.</p><h3>Difference between RMU and Conventional VCB Switch Gear</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/712/1*5gA_pNms8FjdBhyayXkG3Q.png" /></figure><p>Conclusively, RMUs are being widely used all around the world so as to proficiently encounter the increasing requirements of reliable energy. We hope that this blog was helpful and gave you valuable information on the topic. Feel free to suggest or ask any questions you might have in the comments section below. Thank you.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=67d6a1e154ea" width="1" height="1" alt="">]]></content:encoded>