<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Alrightservices on Medium]]></title>
        <description><![CDATA[Stories by Alrightservices on Medium]]></description>
        <link>https://medium.com/@alrightservices1118?source=rss-7d8af35bd2a9------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/0*pMNmgBlu3WqqrjQu</url>
            <title>Stories by Alrightservices on Medium</title>
            <link>https://medium.com/@alrightservices1118?source=rss-7d8af35bd2a9------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Tue, 24 Nov 2026 17:39:11 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@alrightservices1118/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Zero and Span Calibration for Gas Detectors: Step by Step]]></title>
            <link>https://medium.com/@alrightservices1118/zero-and-span-calibration-for-gas-detectors-step-by-stepzero-and-span-calibration-what-actually-6ddfea8b5980?source=rss-7d8af35bd2a9------2</link>
            <guid isPermaLink="false">https://medium.com/p/6ddfea8b5980</guid>
            <category><![CDATA[ship]]></category>
            <category><![CDATA[marine]]></category>
            <category><![CDATA[singapore]]></category>
            <category><![CDATA[gas-detectors]]></category>
            <category><![CDATA[calibration]]></category>
            <dc:creator><![CDATA[Alrightservices]]></dc:creator>
            <pubDate>Tue, 24 Nov 2026 12:59:23 GMT</pubDate>
            <atom:updated>2026-11-24T13:07:08.970Z</atom:updated>
            <content:encoded><![CDATA[<p>Zero sets where a detector’s reading starts and span sets how steep it rises. Here’s what happens at each step of a full calibration, and the settings that can turn a “pass” into a wrong reading.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*M7YHBmD7zVr10GJyc8iNSQ.png" /></figure><p><em>Originally published on </em><a href="https://alrightes.com/zero-and-span-calibration-gas-detector/"><em>Alright Engineering Solutions</em></a></p><p>A gas detector can carry a fresh calibration label and still read low at the top of a ballast tank. Usually nothing’s broken. It was zeroed in air that wasn’t clean, spanned against a cylinder that didn’t match the value in its menu, or fed gas at the wrong flow, and each of those still ends with “pass” on the screen. Here’s what zero and span actually set, and what to check at each step.</p><p><strong>What zero and span actually set</strong></p><p>A sensor doesn’t produce a gas reading. It produces a small electrical signal, which the instrument converts into ppm, %LEL or %vol using a line stored in memory. Zero fixes where that line starts and span fixes how steeply it rises, which is why portable detectors normally get by with a two-point calibration.</p><p>MSA’s documentation puts it simply: <a href="https://docs.msasafety.com/x5000/en-us/ULTIMA%20X5000%20Gas%20monitor/Calibration_Types__Zero_.htm">zero calibration resets the baseline reading to zero</a>, and span gas of a known concentration adjusts the reading to that known value. Because the span is measured from the zero, the order matters. If the zero is off, the slope worked out during the span is off too, and the error carries into every reading afterwards. Honeywell’s calibration guidance says the same: zero first, then span.</p><p>There’s no IMO procedure for any of this. SOLAS regulation XI-1/7 requires a suitable means of calibration and leaves the method to the manufacturer, so the manual is the procedure and the details below vary by model. Our article on <a href="https://alrightes.com/msc-581-110-5-gas-requirement/">what MSC.581(110) means for your detectors</a> covers the regulatory side.</p><p><strong>Bump test, calibration check and full calibration</strong></p><p>US OSHA guidance describes a bump test as a <a href="https://www.osha.gov/publications/shib093013">qualitative check that gas reaches the sensors and the alarms work</a>, and it says plainly that a bump test doesn’t measure accuracy. A calibration check applies a known, traceable concentration and confirms the reading falls within the manufacturer’s tolerance, without adjusting anything. A full calibration is the zero and span adjustment this article is about.</p><p>So a detector that passes its daily bump can still read some way off the cylinder value. Our guide to <a href="https://alrightes.com/bump-test-vs-full-calibration-psc/">bump test vs full calibration and what PSC inspectors check</a> covers the difference in full.</p><p><strong>Before you start: gas, regulator and warm-up</strong></p><p>Most calibration errors are locked in before the first button is pressed. Start with the gas: the mix and concentration the manual specifies, certified, traceable and in date. A typical 4-gas detector takes one quad-mix cylinder, such as a <a href="https://alrightes.com/products/4-mix-co-50ppm-h2s-25ppm-2-5-ch450lel-12-o2-balance-n2/">4-gas calibration mix of CO 50 ppm, H₂S 25 ppm, 2.5% methane and 12% O₂</a>. Extra sensors may need a second cylinder from the <a href="https://alrightes.com/products/calibration-gas-mixtures-specialty-gases/">calibration gas mixtures range</a>.</p><p>The regulator depends on how the detector samples. Diffusion detectors take gas through a calibration cap from a <a href="https://alrightes.com/products/fixed-flow-regulators/">fixed-flow regulator</a> at the manufacturer’s rate; MSA designs around 0.25 L/min while 0.5 L/min is common elsewhere, so a regulator borrowed from another kit isn’t always right. Pumped detectors need a <a href="https://alrightes.com/products/2000-2001-series-demand-flow-regulators/">demand-flow regulator</a>, which releases gas only as the pump draws it. A fixed-flow regulator on a pumped unit can deliver too little or too much gas.</p><p>Then give the detector time to stabilise in clean air, for as long as the manual says. Gas applied to a sensor that’s still settling calibrates it against a moving baseline.</p><p><strong>Step 1: take as-found readings</strong></p><p>Before anything is adjusted, apply the span gas and write down what each sensor reads. That’s the as-found reading, and it’s the only record of how far the detector drifted since its last calibration. Once the span adjusts the sensor, that evidence is gone.</p><p>Automatic routines often go straight to adjustment, so this usually means running a calibration check first. A large as-found error is what tells you the interval may be too long or a sensor is ageing; see <a href="https://alrightes.com/gas-detector-sensor-drift/">why sensor readings drift over time</a>.</p><p><strong>Step 2: zero</strong></p><p>Zeroing tells each sensor that what it’s sampling contains none of its target gas, and the instrument takes your word for it. <a href="https://www.indsci.com/en/blog/calibration-and-bump-testing-policies">Industrial Scientific points out</a> that if the air isn’t truly clean, any relevant gas in it gets stored as zero, and readings stay wrong until the unit is zeroed again in fresh air or with zero air.</p><p>On a ship that rules out the engine room, the pump room and anywhere near an exhaust; open deck on the upwind side usually works. Where clean air can’t be confirmed, Honeywell’s guidance is to zero with zero-grade air or <a href="https://alrightes.com/products/n2-pure-nitrogen-99-995vol-balance-air/">high-purity nitrogen</a> instead. Nitrogen reads 0% oxygen, though, so the manual decides which channels it’s used for; many instruments set the O₂ sensor to its fresh-air value (20.9%, or 20.8% on some MSA models) rather than to zero.</p><p>CO₂ is the main exception: outdoor air holds roughly 425 ppm, so some makers won’t zero a CO₂ channel in fresh air at all. See <a href="https://alrightes.com/co2-sensor-marine-gas-detector-calibration/">how CO₂ channels are zeroed and spanned</a>.</p><p>On an <a href="https://alrightes.com/products/msa-altair-4-4x-multi-gas-detector/">MSA Altair 4X</a> the zero takes about ten seconds and ends with ZERO PASS, or ZERO ERR with the failed sensor flagged. Sort out a zero error before spanning.</p><p><strong>Step 3: span</strong></p><p>With the cap fitted and gas flowing at the right rate, wait for the reading to settle (about a minute per sensor in MSA’s table, two minutes or until stable for other makers), then confirm. The instrument recalculates the slope so that reading matches the span value.</p><p>That span value is where calibrations quietly go wrong. MSA’s manual says the sensor span value in the instrument should match the concentration on the cylinder, unless an LEL simulant gas is being used. Suppose the menu still says 25 ppm H₂S from the last cylinder but the new one holds 20 ppm. The detector is set to read 25 when it sees 20, so it reads about 25% high from then on.</p><p>The LEL channel adds two complications. First, simulant gas: catalytic sensors scaled for pentane are usually spanned with methane, and <a href="https://docs.msasafety.com/altair5x5xir/Content/ALTAIR%205X5XiR%20OPM%2010114801/Calibration_Specificatio.htm">MSA’s calibration table</a> spans a pentane-scaled sensor with 1.45% methane at a span value of 58% LEL. A certificate showing 58% LEL against a methane cylinder isn’t a mistake.</p><p>Second, the LEL basis. The US definition (ISO 10156) treats 5.0% vol methane as 100% LEL, while IEC and EN regions use 4.4%, so the same cylinder is a different %LEL depending on the detector’s setting:</p><figure><img alt="Zero and Span Calibration for Gas Detectors: Step by Step" src="https://cdn-images-1.medium.com/max/693/1*kv5LRhqjbpevtvKjsKltvw.png" /></figure><p>Cylinders labelled “2.5% methane, 50% LEL” are on the 5.0% basis; our own <a href="https://alrightes.com/products/hc-hydro-carbon-methane-2-5-50lel-balance-air/">2.5% methane calibration cylinder</a> gives methane’s LEL as 5.0% on its page. If the detector is configured for 4.4%, MSA’s table gives a span value of 57% for that cylinder. Enter 50% instead and the detector reads roughly 12% low on its own scale. Neither basis is wrong, but the cylinder, span value and detector setting have to agree.</p><p>And where methane might be present, calibrate with methane, since a degrading sensor calibrated on propane or pentane can under-read it.</p><p><strong>Step 4: verify, check alarms and record</strong></p><p>Turn off the gas, remove the cap and let the sensors return to baseline in fresh air. One that won’t come back close to zero needs looking at before the detector goes back into service.</p><p>Then check alarm set points and the audible, visual and vibrating alarms, plus pump flow and the actual sample hose on a pumped unit, since a leaking or blocked line changes what reaches the sensor. Record the as-left reading for each sensor.</p><p>The certificate should show the instrument and each sensor, the gas concentrations with cylinder lot and expiry, as-found and as-left readings, alarm results, the next due date and who did the work. Adding the span value and LEL basis makes methane figures easier to check later. See <a href="https://alrightes.com/marine-calibration-certificates-what-psc-inspectors-look-for/">what PSC inspectors look for on calibration certificates</a>.</p><p><strong>When a span won’t take</strong></p><p>Rule out the setup first: an expired or wrong cylinder, a span value that doesn’t match the cylinder, the wrong regulator for the sampling method, a cap that isn’t seated, or a blocked filter. If all of those check out and the sensor still fails, or only passes by using up most of its remaining adjustment, it’s probably near the end of its life. Our article on <a href="https://alrightes.com/gas-detector-sensor-replacement-interval/">when to replace a sensor instead of recalibrating</a> covers how to tell.</p><p><strong>The sequence in short</strong></p><p>The manual governs the detail for each model, but a full calibration generally runs like this:</p><ol><li>Confirm the gas is the right mix, in date, and matches the span values set in the instrument.</li><li>Fit a fixed-flow regulator for a diffusion detector or a demand-flow regulator for a pumped one.</li><li>Switch on and let the detector stabilise in clean air.</li><li>Apply span gas and record the as-found reading for each sensor.</li><li>Zero in clean air, zero air or nitrogen, as the manual specifies for each channel.</li><li>Span each sensor until the reading is stable, checking the LEL basis and span value.</li><li>Return the detector to fresh air and confirm it comes back to baseline.</li><li>Check alarms, pump flow and the sample line.</li><li>Record as-found and as-left readings, gas details and the next due date.</li></ol><p>How often to repeat it depends on the manufacturer and your SMS; our <a href="https://alrightes.com/marine-instrument-calibration-interval-table-singapore/">calibration interval table</a> gathers the common references.</p><p><strong>Getting it done on board in Singapore</strong></p><p>For <a href="https://alrightes.com/gas-detector-calibration-in-singapore/">onboard gas detector calibration in Singapore</a>, our engineers board alongside or at anchorage with the gases your sensors need. They record as-found readings before any adjustment, zero in clean air or nitrogen for O₂-free checks, span against traceable gas, and test alarms, pump flow and sample lines before the certificate is issued. To arrange a visit, <a href="https://alrightes.com/contact-us/">send us</a> the vessel name, IMO number, berth or anchorage, ETA and a list of your detectors with make, model and serial numbers. If you calibrate in-house, span gas and regulators are supplied from Singapore too; see our <a href="https://alrightes.com/services/#ship-fixed-portable">ship fixed and portable gas detection services</a>.</p><p><em>Read the original article on </em><a href="https://alrightes.com/zero-and-span-calibration-gas-detector/"><em>Alright Engineering Solutions</em></a><em>.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=6ddfea8b5980" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Gas Detector Sensor Life: When to Replace Instead of Recalibrate]]></title>
            <link>https://medium.com/@alrightservices1118/gas-detector-sensor-life-when-to-replace-instead-of-recalibrate-e536ddee19cc?source=rss-7d8af35bd2a9------2</link>
            <guid isPermaLink="false">https://medium.com/p/e536ddee19cc</guid>
            <category><![CDATA[marine]]></category>
            <category><![CDATA[gas-detectors]]></category>
            <category><![CDATA[ship]]></category>
            <category><![CDATA[singapore]]></category>
            <dc:creator><![CDATA[Alrightservices]]></dc:creator>
            <pubDate>Mon, 23 Nov 2026 14:16:01 GMT</pubDate>
            <atom:updated>2026-11-23T14:16:01.538Z</atom:updated>
            <content:encoded><![CDATA[<p>There’s no single gas detector sensor replacement interval. Here’s how long each sensor type usually lasts, and the calibration signs that say replace it.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*ztIZNBuYLvbstoyCCoNe6A.png" /></figure><p><em>Originally published on </em><a href="https://alrightes.com/gas-detector-sensor-replacement-interval/"><em>Alright Engineering Solutions</em></a></p><p>The detector fails its span calibration. Someone suggests trying again, someone else wants to order a new sensor, and a third person asks whether it’s time for a new detector altogether. Each of those can be the right answer, and there’s no IMO rule that settles it. SOLAS and MSC.1/Circ.1477 leave calibration and maintenance to the manufacturer’s instructions, so the gas detector sensor replacement interval on your ship comes down to the maker’s figures, the ship’s planned maintenance system and what the calibrations are telling you. This guide covers how long sensors usually last, the signs that a sensor is finished, and what to rule out before you replace anything.</p><p><strong>How long gas detector sensors last</strong></p><p>Sensor life depends mostly on the technology. These are typical figures from manufacturers and distributors, not deadlines:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/691/1*C8IeYrfmKvfHe9MFG9OTSQ.png" /></figure><p>MSA, for example, says many electrochemical cells last two to three years depending on gas type, exposure and environment, with some designs reaching five to seven. Its Altair 5X specification quotes an expected four-year life for the LEL, O₂, CO, H₂S and IR sensors. The K-600 detectors on our site list a sensor life of two years depending on use.</p><p>A figure like “two-year sensor life” can mean different things, though. It might be a typical service life, a period the instrument is programmed to count down, or a fixed date the maker says the sensor must be replaced by. Check which one your manual means, because a fixed replacement date applies even if the sensor still calibrates.</p><p><strong>Why there’s no single replacement interval</strong></p><p>Two identical sensors can age at very different rates. A sensor’s life is closely tied to how much target gas it sees, and the more often and the higher the concentration, the shorter it lasts. The UK gas detection manufacturers’ association CoGDEM made a similar point when it looked at electrochemical sensor lifetime: sensors kept in clean laboratory air showed little degradation after 15 years, while sensors used to measure boiler flue gas were often replaced every two to three years.</p><p>On a ship, the things that shorten sensor life are mostly the ones that cause drift: heat, humidity swings, poisons such as silicone sprays, high-gas alarms and knocks. We covered those in <a href="https://alrightes.com/gas-detector-sensor-drift/">why gas detector sensors drift</a>. The practical result is that a detector used every week for tank entries on a chemical tanker won’t keep its sensors as long as one that lives in a cabinet on a container ship.</p><p><strong>Signs a sensor needs replacing</strong></p><p>The most useful evidence comes from calibration, because that’s when the sensor’s response is measured against a known gas.</p><p><strong>Falling sensitivity.</strong> Industrial Scientific reports this as “span reserve”. Above 100% means the sensor is in new condition and 70 to 99% is good. At 50 to 69% it’s time to plan a replacement, and below 50% it will fail calibration and must be replaced. Other makers show the same thing in different ways, often as an as-found reading on the certificate or an end-of-life symbol on the display. Normal ageing is linear and gradual, so a sudden drop between two calibrations usually means something outside the sensor, such as poisoning or a big gas exposure, has damaged it.</p><p><strong>Repeated failed spans.</strong> On MSA’s Altair 4X, a sensor life indicator appears when the span calibration fails twice, telling you the sensor has reached the end of its life.</p><p><strong>Still responding, but not reliably.</strong> CoGDEM defines end of life as the point where performance decays rapidly, even though the sensor will still respond to test gas. That’s why a bump test pass doesn’t mean a sensor is healthy. The bump gas is usually well above the alarm point, so a weak sensor can still trip it. We explain the difference in <a href="https://alrightes.com/bump-test-vs-full-calibration-psc/">what a bump test can and can’t prove</a>.</p><p><strong>Slow or unstable behaviour.</strong> An oxygen cell that’s slow to settle at 20.9% in fresh air, a toxic sensor that won’t hold a steady zero, or a response that takes much longer than it used to are all common signs of a sensor near the end, once the gas path has been checked.</p><p><strong>Rule these out before you replace anything</strong></p><p>A failed calibration isn’t always the sensor’s fault. MSA’s own manuals warn that a span calibration can fail for many reasons besides an end-of-life sensor, and tell users to check the gas remaining in the cylinder, its expiry date and the calibration cap before repeating the calibration. Before you condemn a sensor, check that the calibration gas is in date, has enough pressure left and matches the concentration set in the detector. Then check the regulator, tubing and calibration cap for leaks, make sure the filters aren’t blocked and the pump is drawing properly, and confirm the detector had its full warm-up time.</p><p>An expired <a href="https://alrightes.com/products/4-mix-co-50ppm-h2s-25ppm-2-5-ch450lel-12-o2-balance-n2/">4-gas calibration mix</a> can fail a perfectly good sensor, and a fresh cylinder sometimes solves the problem. If the calibration still fails with good gas and a sound gas path, the sensor is the likely cause.</p><p><strong>Sensor or whole detector?</strong></p><p>Once a sensor is condemned, the next question is whether to replace that sensor or the detector. Some instruments are built as sealed, maintenance-free units with a fixed working life, and the whole detector is replaced at the end of it. For serviceable detectors, it usually makes sense to replace a single failed sensor on a unit that’s otherwise in good order. When several sensors are near the end at once, the detector is old, or you need a CO₂ channel the current unit can’t take, a new instrument is often the better spend. Our guide to <a href="https://alrightes.com/4-gas-vs-5-gas-detector-ship/">4-gas vs 5-gas detectors on ships</a> covers that last case.</p><p>Spare sensors also have a shelf life. Electrochemical sensors typically keep for about six months to a year before use, and storage in heat shortens that. A box of spare cells bought three years ago and kept in a hot store may be partly used up before it’s ever fitted. Every new sensor also needs a full zero and span calibration once it’s installed, before the detector goes back into use.</p><p><strong>Sensor replacement checklist</strong></p><ol><li>Check the manual for whether the stated sensor life is a typical figure or a fixed replacement date.</li><li>Record each sensor’s install date, and keep its as-found readings from every calibration.</li><li>Plan a replacement when the sensitivity margin is getting low or the as-found error is growing visit by visit.</li><li>When a calibration fails, check the gas, regulator, cap, filters and pump before blaming the sensor.</li><li>Replace any sensor that fails twice with good gas or shows an end-of-life warning.</li><li>Calibrate every new sensor before use and note the replacement on the certificate or maintenance record.</li><li>Don’t stockpile spare electrochemical sensors, and store any you hold somewhere cool.</li></ol><p><strong>Spotting worn sensors early</strong></p><p>During an <a href="https://alrightes.com/gas-detector-calibration-in-singapore/">onboard gas detector calibration in Singapore</a>, our engineers record as-found readings for every sensor before any adjustment and flag worn filters and failed sensors. It’s part of our <a href="https://alrightes.com/services/#ship-fixed-portable">fixed and portable measurement equipment services</a>. Span gas, regulators and replacement detectors are supplied from Singapore, so a failed sensor doesn’t have to hold the ship up, and sensor replacement and repairs can be handled ashore while a spare meter covers the ship. The full range of units is on our <a href="https://alrightes.com/product-category/portable-gas-detectors/">portable gas detectors</a> page, including pumped models such as the <a href="https://alrightes.com/products/co2-gas-detector-k-600m-built-in-pump-5-in-1-available-with-2-category-co2-ir-sensor-catalytic-sensor/">K-600M 5-in-1 detector</a>. If a detector keeps failing calibration, <a href="https://alrightes.com/contact-us/">send us the model and the last certificate</a> and we’ll tell you whether it looks like the sensor, the gas or the unit.</p><p>Back to that failed span calibration. Trying again is right if the gas or the cap was the problem, and the as-found history on the certificates will show whether this sensor has been sliding for a while. Replacing the whole detector only makes sense when the sensors and the unit are both near the end.</p><p><em>Read the original article on </em><a href="https://alrightes.com/gas-detector-sensor-replacement-interval/"><em>Alright Engineering Solutions</em></a><em>.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=e536ddee19cc" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Enclosed Space Entry Atmosphere Testing: Order of Testing, Readings & Permit RecordsEnclosed Space…]]></title>
            <link>https://medium.com/@alrightservices1118/enclosed-space-entry-atmosphere-testing-order-of-testing-readings-permit-recordsenclosed-space-80fb238403da?source=rss-7d8af35bd2a9------2</link>
            <guid isPermaLink="false">https://medium.com/p/80fb238403da</guid>
            <category><![CDATA[gas-detectors]]></category>
            <category><![CDATA[ship]]></category>
            <category><![CDATA[marine]]></category>
            <category><![CDATA[singapore]]></category>
            <dc:creator><![CDATA[Alrightservices]]></dc:creator>
            <pubDate>Sun, 22 Nov 2026 14:46:01 GMT</pubDate>
            <atom:updated>2026-11-22T14:46:01.520Z</atom:updated>
            <content:encoded><![CDATA[<h3>Enclosed Space Entry Atmosphere Testing: Order of Testing, Readings &amp; Permit RecordsEnclosed Space Entry Atmosphere Testing: Order of Testing, Readings &amp; Permit Records</h3><p>A reading is only as good as the way it was taken. Here’s the testing order, sampling technique and permit records that make an enclosed space entry defensible.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*NYF3UInvhiQiaUNfoE5UQQ.png" /></figure><p><em>Originally published on </em><a href="https://alrightes.com/enclosed-space-entry-atmosphere-testing-procedure/"><em>Alright Engineering Solutions</em></a></p><p>In June 2022, three stevedores died in a cargo hold access space on the bulk carrier Berge Mawson at anchorage off Indonesia. The UK’s Marine Accident Investigation Branch found the hold atmosphere hadn’t been tested before anyone went in (<a href="https://assets.publishing.service.gov.uk/media/67d7de37c7a690273792824a/2025-5-BergeMawson-ReportAndAnnexes.pdf">MAIB report</a>). Most ships do test, and most have a permit form. Where things go wrong is usually in the detail: which reading to trust first, where the sample came from, how long the hose took to deliver it, and what ended up on paper. This enclosed space entry atmosphere testing procedure walks through each step against IMO Resolution MSC.581(110), with the paragraph numbers so your SMS can reference them.</p><p><strong>Before you test: the space, the meter and the permit</strong></p><p>Testing starts before the detector is switched on. The space should be in the ship’s Enclosed Space Register, which MSC.581(110) expects to be kept on board and ashore, and a competent person should have assessed its hazards (4.1 to 4.3). That includes connected and adjacent spaces, the cargo history and anything that can consume oxygen or give off gas, such as organic cargoes, sludge or rusting steel.</p><p>Then check the instrument. Paragraph 7.2 asks for “properly calibrated equipment” used by trained people, with the manufacturer’s instructions strictly followed. In practice, check that the calibration label and certificate are in date and that the certificate lists every sensor, CO₂ included. Bump-test the meter before use (we’ve covered <a href="https://alrightes.com/bump-test-vs-full-calibration-psc/">what a bump test can and can’t prove</a>). Then check the pump, hose and probe, which is easiest done by drawing span gas through the full length of hose and confirming the meter responds. Pump flow and sample lines are also something we check during an <a href="https://alrightes.com/gas-detector-calibration-in-singapore/">onboard gas detector calibration</a>.</p><p>Last, make sure the meter can measure what the risk assessment calls for. If CO₂ is a credible hazard and the unit is a 4-gas, you’ll need a CO₂ instrument alongside it. Our guide to <a href="https://alrightes.com/4-gas-vs-5-gas-detector-ship/">4-gas vs 5-gas detectors on ships</a> covers the options.</p><p><strong>Which order to test in</strong></p><p>The “oxygen first, then flammables, then toxics” order is so familiar that most people assume the IMO requires it. It doesn’t. MSC.581(110) lists the entry criteria in paragraph 7.4 as oxygen, CO₂, flammables, then toxics, and the sample permit in Appendix 2 lists oxygen, flammables, toxics, then CO₂. Neither is presented as a mandatory sequence.</p><p>The well-known order comes from US shore regulations. OSHA’s confined space standard, 29 CFR 1910.146, requires testing for oxygen, then flammable gases and vapours, then toxic air contaminants (<a href="https://www.osha.gov/laws-regs/standardinterpretations/1994-07-13">OSHA interpretation letter</a>). It’s a US rule, but the reasoning behind it holds at sea. Most portable LEL sensors are catalytic beads, which need oxygen to burn the gas they’re measuring. In an oxygen-depleted space they can read low, so a reassuring %LEL figure means little until you know the oxygen level.</p><p>A modern multigas meter samples every channel at once, so the order is really about how you read the display. Look at oxygen first. If it’s below 20.9%, MSC.581(110) paragraph 6.5.3 treats the space as unsafe anyway, and the flammable reading on a catalytic sensor can’t be trusted. Only when oxygen is right do the LEL, CO₂ and toxic figures mean what they say.</p><p><strong>Taking a reading you can trust</strong></p><p>Most bad readings come from technique rather than the instrument.</p><p><strong>Stop the ventilation first.</strong> Paragraph 7.6 says gas testing should be done with ventilation stopped and after conditions have stabilised. The sample permit suggests stopping it for about 10 minutes before the pre-entry tests. Testing with the fan running mostly measures the air the fan is pushing in.</p><p><strong>Allow for the hose.</strong> A pumped sample takes time to travel up the tube. A common rule of thumb is at least one second per foot of tubing, roughly three seconds per metre, plus the sensor’s own response time. Some trainers use a more cautious two seconds per foot. On a 20-metre hose, that’s at least a minute before the display is showing gas from the far end. Your detector’s manual has the figure that applies to it, and it’s worth reading.</p><p><strong>Wait for steady readings.</strong> Paragraph 7.4 asks for steady readings of every parameter. A number that’s still climbing or falling isn’t a result yet.</p><p><strong>Test at several levels and openings.</strong> Gases stratify. CO₂ and H₂S are heavier than air and collect low, while methane rises, and pockets can sit behind frames or in bilge wells. Paragraph 7.2 asks for testing at as many levels and areas as necessary, and the resolution’s notes call for samples from several levels and through as many openings as possible. A single reading at the manhole isn’t a test of the space.</p><p>Pumped detectors make this practical. The <a href="https://alrightes.com/products/co2-gas-detector-k-600m-built-in-pump-5-in-1-available-with-2-category-co2-ir-sensor-catalytic-sensor/">K-600M 5-in-1 detector</a>, for example, has a built-in pump rated for sampling through up to 20 metres of hose. Paragraph 7.3 also allows flexible hoses or fixed sampling lines to reach remote areas without anyone entering.</p><p>Even after a good test, paragraph 7.8 says oxygen-deficient areas may still exist and should always be suspected. That’s why the personal detector matters once people are inside.</p><p><strong>Reading the numbers</strong></p><p>These are the MSC.581(110) entry criteria and what each result means for the permit.</p><figure><img alt="Enclosed Space Entry Atmosphere Testing: Order of Testing, Readings &amp; Permit Records" src="https://cdn-images-1.medium.com/max/701/1*5i-ip1X-2r9jmSGWS_eEhg.png" /></figure><p>Paragraph 7.5 says that if any limit isn’t met, more ventilation should be applied and the space retested after a suitable interval. Paragraph 7.7 adds that oxygen and flammability readings tell you nothing about toxicity, so each gas has to be measured in its own right. If you want the background on the CO₂ limit, we explain <a href="https://alrightes.com/msc-581-110-5-gas-requirement/">what MSC.581(110) changed</a>, and why a CO₂ channel’s zero needs care in <a href="https://alrightes.com/co2-sensor-marine-gas-detector-calibration/">how CO₂ sensors are calibrated</a>.</p><p><strong>During entry: retests and when to get out</strong></p><p>The pre-entry test only describes the space at that moment. Paragraph 8.1 says the atmosphere should be tested frequently while the space is occupied, and people should leave if conditions get worse. Each person going in should wear a calibrated, tested personal detector that monitors oxygen, CO₂, flammables and toxic gases including CO (8.2). A clip-on single-gas unit such as a <a href="https://alrightes.com/products/bell-mini-single-gas-detector-o2/">BELL MINI O₂ monitor</a> is useful as a backup, but it doesn’t cover CO₂ or the other gases on its own.</p><p>Ventilation should stay on while people are inside (8.3). After a break, the space has to be retested, and the results verified and recorded, before anyone goes back in. Paragraph 8.4 asks for more frequent testing when conditions change, for example with hot work, a change in temperature, or sludge being disturbed during cleaning.</p><p><strong>What the permit should record</strong></p><p>MSC.581(110) says the master or a nominated responsible person issues the permit, and its validity is set by the risk assessment but should never be longer than eight hours (5.2). The sample permit in Appendix 2 becomes invalid if ventilation stops, and leaving the space unattended voids it too.</p><p>Appendix 2 has fields for each reading with “By” and “Time” next to them. It doesn’t have a field for the instrument used, and that’s the gap we’d close. A reading is only as good as the meter that took it, and without the serial number nobody can link the result to a calibration certificate later.</p><figure><img alt="Enclosed Space Entry Atmosphere Testing: Order of Testing, Readings &amp; Permit Records" src="https://cdn-images-1.medium.com/max/703/1*IMywsstbl5hXemy52eRNUQ.png" /></figure><p>MSC.581(110) doesn’t set a retention period for permits, so your SMS decides how long they’re kept. When you check the certificate behind each meter, our guide to <a href="https://alrightes.com/marine-calibration-certificates-what-psc-inspectors-look-for/">what PSC inspectors look for on marine calibration certificates</a> covers the detail.</p><p><strong>The testing sequence at a glance</strong></p><ol><li>Confirm the space in the Register and complete the risk assessment.</li><li>Check the meter’s calibration date, bump-test it, and check the pump and hose with gas.</li><li>Ventilate, then stop ventilation and wait for conditions to settle (about 10 minutes, per Appendix 2).</li><li>Sample through the hose, allowing for transit time, at several levels and openings.</li><li>Read oxygen first, then CO₂, flammables and toxics, and wait for steady values.</li><li>Compare against the 7.4 criteria; if any fail, ventilate and retest.</li><li>Record every reading with time, location, tester and instrument serial number, then issue the permit for no more than eight hours.</li><li>Restart ventilation, put personal detectors on each entrant, and retest after every break.</li></ol><p><strong>Keeping the meter honest</strong></p><p>All of this depends on a detector that reads true. Our <a href="https://alrightes.com/gas-detector-calibration-in-singapore/">gas detector calibration service in Singapore</a> tests alarm set points, pump flow and sample lines along with every sensor, on board alongside or at anchorage, and the certificate records as-found and as-left readings with the gas lot numbers used. It’s part of our <a href="https://alrightes.com/services/#ship-fixed-portable">fixed and portable measurement equipment services</a>. If you’d like your detectors checked before a run of tank or hold entries, <a href="https://alrightes.com/contact-us/">send us the instrument list</a> and we’ll confirm what’s needed. The full range of portable units is on our <a href="https://alrightes.com/product-category/portable-gas-detectors/">portable gas detectors</a> page.</p><p>The Berge Mawson report is a hard read because there was no test at all. On most ships the risk is quieter: a test that was done, but taken at the hatch with the fan running and the hose half-purged, and written up with no way of telling which meter took it.</p><p><em>Read the original article on </em><a href="https://alrightes.com/enclosed-space-entry-atmosphere-testing-procedure/"><em>Alright Engineering Solutions</em></a><em>.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=80fb238403da" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Sensor Drift Explained: Why a Detector That Passed Last Month Reads Wrong Today]]></title>
            <link>https://medium.com/@alrightservices1118/sensor-drift-explained-why-a-detector-that-passed-last-month-reads-wrong-today-82b2dc8dce7e?source=rss-7d8af35bd2a9------2</link>
            <guid isPermaLink="false">https://medium.com/p/82b2dc8dce7e</guid>
            <category><![CDATA[gas-detectors]]></category>
            <category><![CDATA[singapore]]></category>
            <category><![CDATA[marine]]></category>
            <category><![CDATA[ship]]></category>
            <dc:creator><![CDATA[Alrightservices]]></dc:creator>
            <pubDate>Sat, 21 Nov 2026 10:42:24 GMT</pubDate>
            <atom:updated>2026-11-21T10:42:24.429Z</atom:updated>
            <content:encoded><![CDATA[<p>Every gas sensor drifts. Here’s how each type loses accuracy, what speeds it up on a ship in Singapore’s humidity, and how your calibration certificates show it.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*7JMMLamEabc4xAUEklXRYg.png" /></figure><p><em>Originally published on </em><a href="https://alrightes.com/gas-detector-sensor-drift/"><em>Alright Engineering Solutions</em></a></p><p>A detector was calibrated last month, the certificate is in the folder, and this morning it fails its bump test or reads a few ppm low against the test cylinder. Nothing is broken in the obvious sense. The sensor has drifted, which is what sensors do. OSHA’s guidance on portable gas monitors puts it plainly: calibration drift “happens to all sensors over time” (<a href="https://www.osha.gov/publications/shib093013">OSHA SHIB 09–30–2013</a>). This guide explains how each type of sensor drifts, what speeds it up on a ship, and how to read drift from your own calibration records before it catches someone out.</p><p><strong>What gas detector sensor drift is</strong></p><p>Drift is a slow change in what a sensor reports for the same amount of gas. It shows up in two ways. Zero drift moves the baseline, so the meter shows a small reading in clean air or a slightly wrong one in nitrogen. Span drift changes the sensitivity, so the meter under-reads or over-reads a known concentration. Most drift in portable detectors is a loss of sensitivity, and a sensor that has lost sensitivity reads low, which is the dangerous direction.</p><p>The rate varies by sensor. Manufacturers commonly define drift for electrochemical sensors as somewhere under 2% to under 5% a month, so a cell that read 100 ppm on its calibration day might read 95 ppm a month later. At 5% a month, three months gives a sensor reading about 86% of the true value (our arithmetic), and an H₂S alarm set at 10 ppm then wouldn’t sound until the real level was nearer 12 ppm.</p><p><strong>How each sensor type drifts</strong></p><p>The four sensor types in a typical marine multigas detector age in different ways.</p><figure><img alt="Sensor Drift Explained: Why a Detector That Passed Last Month Reads Wrong Today" src="https://cdn-images-1.medium.com/max/714/1*FozW-yLjUpG7PdsRfdhImw.png" /></figure><p><strong>Electrochemical toxic sensors</strong> contain a liquid electrolyte, often sulphuric acid, that gains water in humid air and loses it in dry air. Sensor makers specify sensitivity loss of up to around 20% a year for some cells. OSHA lists solvent vapours and highly corrosive gases as contaminants that can damage them, and some cleaning alcohols do the same.</p><p><strong>Oxygen cells</strong> are galvanic. The lead anode is consumed as the sensor measures oxygen, so the cell has a fixed life, and when the lead runs out the cell can fail with very little warning. A cell that’s slow to reach 20.9% in fresh air, or struggles to span, is usually close to that point.</p><p><strong>Catalytic LEL beads</strong> are the most exposed to sudden damage. OSHA names volatile silicones, hydride gases, halogenated hydrocarbons and sulphide gases as poisons. Honeywell’s technical note on LEL poisons separates the two effects: poisoning is permanent, while inhibition, for example by H₂S, usually recovers in clean air. Silicone sprays and some engine room lubricants are the usual suspects on a ship. A poisoned bead can sit at zero in fresh air and look perfectly healthy, which is why a bump test or calibration is the only way to catch it.</p><p><strong>NDIR sensors</strong> for CO₂ drift more slowly because nothing in them is consumed, but the lamp and detector still age, and moisture or dirt on the optics shifts the reading. The zero is a particular trap for CO₂, which we cover in <a href="https://alrightes.com/co2-sensor-marine-gas-detector-calibration/">how CO₂ sensors on marine gas detectors are calibrated</a>.</p><p><strong>What speeds drift up on a ship</strong></p><p>OSHA’s bulletin lists the main causes of calibration drift, and several describe ordinary life at sea. Alongside normal ageing and the poisons above, it names extreme temperature and humidity, high levels of airborne particulates, exposure to high concentrations of the target gas, and handling or knocks that affect the electronics over time.</p><p>Humidity matters in Singapore and the region. Some electrochemical cells start absorbing water once relative humidity goes above about 60%, and Singapore’s long-term average sits well above that, at roughly 80 to 85% according to <a href="https://data.gov.sg/dataset/relative-humidity-annual-mean">NEA’s records</a>. The bigger problem is usually the swing. A detector carried from a cold, air-conditioned control room into a hot, damp engine room or tank can collect moisture on or inside the sensor, which can cause baseline drift.</p><p>Storage is the easiest factor to control. A detector kept in a cabinet in the accommodation will usually age more gently than one left on a shelf in the engine room or in a deck locker, and it’s worth logging any time a detector is dropped or saw a big gas alarm, because both are reasons to check it before the next entry.</p><p><strong>Why last month’s pass doesn’t cover today</strong></p><p>It’s reasonable to treat a recent calibration certificate as proof the meter is right. For most of the month it probably is. The trouble is that drift is continuous and some damage happens in a single event, such as one silicone spray, one drop or one very high H₂S reading.</p><p>A bump test helps, but it answers a narrower question. OSHA defines it as a qualitative check that the sensors and alarms respond. A calibration check confirms the readings are within the manufacturer’s limits, and a full calibration adjusts them to a certified gas. A meter can pass a bump test while reading low, because the alarm still trips at the bump gas concentration. We’ve covered the difference in more detail in <a href="https://alrightes.com/bump-test-vs-full-calibration-psc/">what a bump test can and can’t prove</a>.</p><p>US industry guidance from ISEA recommends a bump test or calibration check before each day’s use, with a full calibration if it fails. The IMO doesn’t set an interval. MSC.1/Circ.1477 leaves it to the manufacturer, and MSC.581(110) asks for “properly calibrated” equipment, so the actual schedule sits in your SMS. Our <a href="https://alrightes.com/marine-instrument-calibration-interval-table-singapore/">marine instrument calibration interval table</a> is a reasonable place to start.</p><p><strong>Reading drift on your calibration certificates</strong></p><p>The most useful drift data you have is probably already in your files. A good calibration certificate records an as-found reading, taken before any adjustment, and an as-left reading after it. The as-found figure tells you how far each sensor had drifted since the last visit.</p><p>Put two or three certificates for the same detector side by side and patterns appear. For example, a CO sensor that was 3% low last time and 12% low this time is ageing faster than the interval allows for. An O₂ cell that needed more adjustment at each visit is heading for replacement. A catalytic sensor that suddenly lost half its response points to poisoning rather than age. None of that is visible from a pass or fail label. It’s why our <a href="https://alrightes.com/gas-detector-calibration-in-singapore/">gas detector calibration in Singapore</a> records as-found and as-left readings for every sensor, along with the calibration gas lot numbers. For how inspectors read those documents, see <a href="https://alrightes.com/marine-calibration-certificates-what-psc-inspectors-look-for/">what PSC inspectors look for on marine calibration certificates</a>.</p><p>The gas matters as well. OSHA advises using only certified, traceable test gas within its expiry date. An expired <a href="https://alrightes.com/products/4-mix-co-50ppm-h2s-25ppm-2-5-ch450lel-12-o2-balance-n2/">4-gas calibration mix</a> or a single-gas cylinder such as <a href="https://alrightes.com/products/h2s-hydrogen-sulphide-25-50ppm-balance-air-n2/">H₂S 25 ppm</a> that’s past its date can make a drifting sensor look fine, or a good one look faulty.</p><p><strong>Drift checks for the ship</strong></p><ol><li>Bump-test each detector before the day’s use, with in-date gas.</li><li>Log any drop, heavy knock or high gas alarm, and check that detector before its next entry.</li><li>Keep silicone sprays and solvent cleaners away from detectors and their storage.</li><li>Store detectors away from the engine room, and let them settle before use after a big temperature change.</li><li>Compare as-found readings across your last few certificates and note any sensor getting worse.</li><li>Replace sensors that keep failing calibration rather than adjusting them again.</li></ol><p><strong>Getting drift measured properly</strong></p><p>Drift isn’t a fault you can fix once. It’s something you measure and manage. Our engineers calibrate portable and personal detectors on board, alongside or at anchorage, as part of our <a href="https://alrightes.com/services/#ship-fixed-portable">fixed and portable measurement equipment services</a>, and record what each sensor read before adjustment so you can see the trend. If you’d like to check a detector you’re unsure of, <a href="https://alrightes.com/contact-us/">send us the model and your last certificate</a>. Replacement units and single-gas monitors such as the <a href="https://alrightes.com/products/bell-mini-single-gas-detector/">BELL MINI H₂S detector</a> are on our <a href="https://alrightes.com/product-category/portable-gas-detectors/">portable gas detectors</a> page.</p><p>Back to the detector that passed last month. It was probably right on the day it was calibrated. What its certificate can’t tell you is how much it has moved since, and only certified gas will show that.</p><p><em>Read the original article on </em><a href="https://alrightes.com/gas-detector-sensor-drift/"><em>Alright Engineering Solutions</em></a><em>.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=82b2dc8dce7e" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Is Your 4-Gas Detector Still Compliant? 4-Gas vs 5-Gas for Enclosed Space Entry]]></title>
            <link>https://medium.com/@alrightservices1118/is-your-4-gas-detector-still-compliant-4-gas-vs-5-gas-for-enclosed-space-entry-1b33a231465f?source=rss-7d8af35bd2a9------2</link>
            <guid isPermaLink="false">https://medium.com/p/1b33a231465f</guid>
            <category><![CDATA[calibration]]></category>
            <category><![CDATA[singapore]]></category>
            <category><![CDATA[gas-detectors]]></category>
            <category><![CDATA[mariners]]></category>
            <category><![CDATA[ship]]></category>
            <dc:creator><![CDATA[Alrightservices]]></dc:creator>
            <pubDate>Fri, 20 Nov 2026 14:36:01 GMT</pubDate>
            <atom:updated>2026-11-20T14:36:01.671Z</atom:updated>
            <content:encoded><![CDATA[<p>Your 4-gas meter still meets SOLAS, but it can’t see CO₂. Here’s how to decide between adding a CO₂ monitor, fitting a sensor or replacing the unit.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*N7lYqSHawjiLZGPlkfvfOQ.png" /></figure><p><em>Originally published on </em><a href="https://alrightes.com/4-gas-vs-5-gas-detector-ship/"><em>Alright Engineering Solutions</em></a></p><p>Your 4-gas detector still meets SOLAS. What it can’t do is read carbon dioxide, and the IMO’s revised enclosed space guidance now asks for a CO₂ reading below 0.5% by volume before anyone goes in. Whether that leaves your meter “non-compliant” depends on your flag, your cargoes and how your SMS treats the guidance, so the honest answer is more useful than a yes or no. This guide sets out what each type of detector measures, where the 4-gas meter stands today, and three practical ways to close the CO₂ gap.</p><p><strong>What a 4-gas and a 5-gas detector each measure</strong></p><p>A standard 4-gas meter reads the four gases SOLAS regulation XI-1/7 has required since 2016. A marine 5-gas unit adds a fifth sensor for CO₂, almost always infrared.</p><figure><img alt="Is Your 4-Gas Detector Still Compliant? 4-Gas vs 5-Gas for Enclosed Space Entry" src="https://cdn-images-1.medium.com/max/689/1*Ox46OxkDMsEZ_W5VG6Eqhg.png" /></figure><p>The oxygen sensor won’t stand in for the missing CO₂ channel. The CO₂ table in <a href="https://wwwcdn.imo.org/localresources/en/KnowledgeCentre/IndexofIMOResolutions/MSCResolutions/MSC.581(110).pdf">Appendix 5 of MSC.581(110)</a> gives 3% CO₂ as a 10-minute ceiling exposure limit, and at that level the O₂ reading would only have dropped to about 20.3%. We go through the sensor side in <a href="https://alrightes.com/co2-sensor-marine-gas-detector-calibration/">how CO₂ sensors on marine gas detectors are calibrated</a>.</p><p><strong>Compliant with what?</strong></p><p>“Compliant” needs a reference point, and there are three that matter here.</p><p><strong>SOLAS XI-1/7.</strong> This is mandatory, and a calibrated 4-gas meter still satisfies it. The regulation names oxygen, flammables, CO and H₂S, plus a suitable means of calibration. CO₂ isn’t on the list.</p><p><strong>MSC.581(110).</strong> The IMO’s revised recommendations took effect on 3 December 2025. Paragraph 7.4.2 sets the CO₂ limit before entry, and paragraph 8.2 lists CO₂ among the gases each entrant’s personal detector should monitor. It’s a recommendation, though, and the resolution invites governments to bring it to shipowners’ attention rather than amending SOLAS. We cover the detail in <a href="https://alrightes.com/msc-581-110-5-gas-requirement/">what MSC.581(110) actually asks of your detectors</a>.</p><p><strong>Your flag.</strong> This is where the recommendation turns into a rule, or doesn’t. The Danish Maritime Authority wrote MSC.581(110) into law from 1 July 2026 and gave Danish ships until 1 December 2026 to get CO₂ devices on board (<a href="https://www.soefartsstyrelsen.dk/Media/639184136799484507/DMA%20RO%20Circular%20no.%20035%20Delayed%20implementation%20date%20of%20MSC.581(110)%20Rev%2001.pdf">DMA Circular 035</a>). The Isle of Man went further back in 2024. Its <a href="https://iomshipregistry.com/media/nmch0f0b/005-24-enclosed-space-entry-gas-detection-and-co2-hazards.pdf">Technical Advisory Notice 005–24</a> treats the basic four-gas detector as insufficient for organic cargoes, and says CO₂-emitting cargoes shouldn’t go on a ship’s cargo list unless CO₂ detection is on board.</p><p>Class societies have told owners to align their SMS with the resolution, taking their flag into account, and the Tokyo MOU has a joint inspection campaign on enclosed space entry planned with the Paris MoU for 2027. So even where your flag hasn’t legislated, it would be unwise to plan around the 4-gas meter alone.</p><p><strong>When a 4-gas meter still earns its place</strong></p><p>Some pages tell owners to bin every 4-gas detector. That’s poor advice. A working, calibrated 4-gas meter is still a valid SOLAS instrument, and plenty of ships bought theirs because it was exactly what the rules asked for.</p><p>The difficulty is arguing that CO₂ doesn’t matter for a given entry. Paragraph 8.2 names CO₂ for every entrant’s detector. Paragraph 10.5.7 says ships carrying organic cargoes in bulk should keep testing for CO₂ before entry and frequently afterwards, because those cargoes continue to emit it. Rust uses up oxygen too, and ABS’s summary of the resolution notes that testing in steel-related spaces such as chain lockers has to allow for oxygen lost to oxidation. A risk assessment that rules CO₂ out entirely is hard to defend for most cargo ships.</p><p>So the realistic role for a 4-gas meter is alongside a CO₂ instrument, or as the second SOLAS set, rather than on its own. That’s also how ABS frames it in its <a href="https://ww2.eagle.org/content/dam/eagle/regulatory-news/2025/Regulatory%20News%20-%20Revised%20Recommendations%20for%20Confined%20Space%20Entry.pdf">guidance on the resolution</a>: verify what your detectors can measure, then replace or supplement them.</p><p><strong>Three ways to close the CO₂ gap</strong></p><figure><img alt="Is Your 4-Gas Detector Still Compliant? 4-Gas vs 5-Gas for Enclosed Space Entry" src="https://cdn-images-1.medium.com/max/717/1*WBHt6dYScYJXiqPQSU-mDg.png" /></figure><p>The first route is quicker than it sounds. Single-gas CO₂ personal monitors using NDIR sensors exist, so a ship can cover the gap without replacing every instrument. The cost is discipline, because two devices mean two charging routines, two bump tests and two lines in the calibration schedule, and the CO₂ monitor is the one most likely to be left in the cabinet. An <a href="https://alrightes.com/gas-detector-calibration-in-singapore/">onboard gas detector calibration</a> visit can at least cover both instruments in one attendance.</p><p>The second route depends entirely on the hardware. Many 4-gas designs have exactly four sensor positions. The <a href="https://alrightes.com/products/msa-altair-4-4x-multi-gas-detector/">MSA Altair 4X</a>, for example, takes LEL, oxygen and up to two toxic gases, and there’s no option for CO₂. Other platforms are built for it. MSA’s Altair 5X IR can carry one infrared sensor for CO₂, and Dräger offers IR CO₂ sensors for several of its X-am models. If you’re not sure which you have, check the model number against the manual before ordering a sensor.</p><p>The third route suits ships whose existing sensors are close to the end of their life anyway. The <a href="https://alrightes.com/products/co2-gas-detector-k-600m-built-in-pump-5-in-1-available-with-2-category-co2-ir-sensor-catalytic-sensor/">K-600M pumped 5-in-1 detector</a> is one example, with an IR CO₂ sensor reading 0 to 5% by volume. The rest of the range is on our <a href="https://alrightes.com/product-category/portable-gas-detectors/">portable gas detectors</a> page.</p><p><strong>What to check before you buy</strong></p><p>Whichever route you take, a few specifications decide whether the instrument is fit for enclosed space work.</p><p><strong>Hazardous-area certification.</strong> MSC.1/Circ.1477 says the SOLAS instrument should be intrinsically safe. Not every CO₂ monitor on the market is. Some single-gas CO₂ units are sold for safe areas only, so check the Ex marking and the certificate before anything goes near a hold or tank.</p><p><strong>Range and resolution near 0.5%.</strong> A sensor that reads in 0.1% steps gives you five steps up to the limit. One that reads in 0.01% steps gives you fifty. For a pass or fail decision at 0.5%, the finer resolution is worth having.</p><p><strong>Pump or diffusion.</strong> Pre-entry testing from outside the space needs a pump and hose. Paragraph 7.2 also asks for readings at as many levels and areas as necessary, because gases stratify. A diffusion-only personal monitor is fine on the belt, but it won’t sample the bottom of a tank from the manhole.</p><p><strong>Run time and power.</strong> IR-equipped units usually run for less time between charges. MSA’s specification lists at least 17 hours for the IR version of the Altair 5X against 20 hours for the standard unit, and only the non-IR units have an alkaline battery option. That matters on long tank inspections.</p><p><strong>Span gas.</strong> A CO₂ channel needs its own calibration gas. The four-gas cylinder most ships carry has no CO₂, so budget for <a href="https://alrightes.com/products/1-3-5-10-15-carbon-dioxide-bal-n2/">CO₂ span gas in nitrogen</a> at the concentration the manual specifies.</p><p><strong>Numbers of sets.</strong> Paragraph 7.3 asks for at least two sets of gas detection equipment, with two more on ships carrying cargoes that need regular entry for inspection or cleaning. Plan the CO₂ coverage across all of them, not only the one the chief officer carries.</p><p><strong>A detector review checklist</strong></p><ol><li>List every portable and personal detector on board with make, model, serial number and fitted sensors.</li><li>Mark which units have a CO₂ channel and which could take one.</li><li>Check each unit’s Ex certification and its CO₂ range and resolution.</li><li>Compare the number of CO₂-capable sets with paragraph 7.3 and your cargo profile.</li><li>Read your flag’s latest circular on MSC.581(110) and note any deadline.</li><li>Confirm the ship holds CO₂ span gas, in date, and that every certificate lists all sensors with as-found and as-left readings.</li><li>Update the SMS, the entry permit and crew training to cover the CO₂ readings and the instrument you’ve chosen. EEBDs aren’t suitable for entry, as paragraph 9.2 reminds, so the plan should never lean on them.</li></ol><p><strong>Getting your detectors reviewed in Singapore</strong></p><p>Our <a href="https://alrightes.com/gas-detector-calibration-in-singapore/">gas detector calibration service in Singapore</a> covers the 4-gas meters you keep as well as new CO₂-capable units, on board alongside or at anchorage, with certificates showing as-found and as-left readings for every sensor. On that page we also suggest a 5-gas unit or a separate CO₂ monitor where a 4-gas meter lacks a CO₂ channel, which is the same choice this article sets out. If you’d like a second opinion first, <a href="https://alrightes.com/contact-us/">send us your detector list</a> and we’ll mark which route fits each unit, as part of our <a href="https://alrightes.com/services/#ship-fixed-portable">fixed and portable measurement equipment services</a>. For what inspectors look for afterwards, see our posts on <a href="https://alrightes.com/bump-test-vs-full-calibration-psc/">what a bump test can and can’t prove</a> and <a href="https://alrightes.com/top-psc-detainable-deficiencies-linked-to-uncalibrated-equipment/">PSC deficiencies linked to uncalibrated equipment</a>.</p><p>The 4-gas meter in your locker isn’t obsolete, and it may be reading perfectly well. It’s just answering four of the five questions the entry permit now asks.</p><p><em>Read the original article on </em><a href="https://alrightes.com/4-gas-vs-5-gas-detector-ship/"><em>Alright Engineering Solutions</em></a><em>.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=1b33a231465f" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[CO₂ Sensors on Marine Gas Detectors: Why NDIR, and How They’re Calibrated]]></title>
            <link>https://medium.com/@alrightservices1118/co%E2%82%82-sensors-on-marine-gas-detectors-why-ndir-and-how-theyre-calibrated-235e37066aea?source=rss-7d8af35bd2a9------2</link>
            <guid isPermaLink="false">https://medium.com/p/235e37066aea</guid>
            <category><![CDATA[ship]]></category>
            <category><![CDATA[singapore]]></category>
            <category><![CDATA[co₂-sensors]]></category>
            <category><![CDATA[gas-detectors]]></category>
            <category><![CDATA[mariners]]></category>
            <dc:creator><![CDATA[Alrightservices]]></dc:creator>
            <pubDate>Thu, 19 Nov 2026 14:31:01 GMT</pubDate>
            <atom:updated>2026-11-19T14:31:01.853Z</atom:updated>
            <content:encoded><![CDATA[<p>Fresh air isn’t a true zero for CO₂. Here’s how NDIR sensors on marine gas detectors work, and how to zero and span them so the 0.5% entry limit means something.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*RXgkwJ-GAWsqFdUS7_EuLg.png" /></figure><p><em>Originally published on </em><a href="https://alrightes.com/co2-sensor-marine-gas-detector-calibration/"><em>Alright Engineering Solutions</em></a></p><p>A lot of ships now carry a gas detector with a CO₂ channel, mostly because IMO Resolution MSC.581(110) sets a pre-entry limit of 0.5% CO₂ by volume (5,000 ppm). It’s only useful if it reads true near that limit, and it’s calibrated differently from the O₂, LEL, CO and H₂S sensors the crew already know. Get the zero or the span gas wrong and the entry decision gets made on a number that’s off by a sizeable fraction of the limit. This guide covers how the sensor works, what makes it drift, and what a sound CO₂ calibration looks like.</p><p><strong>Why CO₂ has to be measured directly</strong></p><p>It’s tempting to assume the oxygen sensor will catch a CO₂ build-up, since CO₂ displaces air. The numbers say otherwise. Fresh air is about 20.9% oxygen, so if CO₂ rises to 3% by volume and displaces air evenly, oxygen only falls to roughly 20.3%. That’s still above the 19.5% low-oxygen alarm many detectors are set to, while CO₂ sits at six times the entry limit.</p><p>That’s why MSC.581(110) names CO₂ separately, and why the Isle of Man Ship Registry told owners back in 2024 that the basic four-gas detector isn’t enough for organic cargoes. We cover the regulation itself in <a href="https://alrightes.com/msc-581-110-5-gas-requirement/">what MSC.581(110) actually asks of your detectors</a>. The rest of this article is about the sensor.</p><p><strong>How an NDIR CO₂ sensor works</strong></p><p>Almost every portable CO₂ channel uses non-dispersive infrared (NDIR). An infrared source shines through a small gas cell onto a detector fitted with a filter tuned to about 4.26 µm, a wavelength CO₂ absorbs strongly. The more CO₂ in the cell, the less light reaches the detector, and the instrument converts that loss into a concentration.</p><p>Most designs add a second, reference channel at a wavelength CO₂ doesn’t absorb. Because both channels see the same lamp and the same temperature, comparing them cancels out much of the drift from an ageing source or a warm engine room.</p><p>For marine work, NDIR has two practical advantages. It doesn’t consume oxygen to make a measurement, which matters because MSC.581(110) paragraph 7.1 asks for CO₂ devices that work correctly in oxygen-depleted air. And it isn’t poisoned by silicones or sulphur compounds the way a catalytic LEL bead can be.</p><p><strong>What still makes an NDIR reading drift</strong></p><p>NDIR is stable, but it doesn’t correct itself. Room CO₂ sensors in offices often run automatic background calibration, quietly treating the lowest reading of the week as about 400 ppm. A safety detector shouldn’t be trusted that way. Its accuracy is set and checked with gas.</p><p>Three things move the reading over time. The lamp and optics age, and the reference channel only compensates for part of that. The sensor counts molecules, so changes in sample pressure shift the result, and a sensor without pressure compensation will underreport at lower pressure. Moisture is the third, and the most practical one on a ship. A pumped sample drawn up a long hose from a damp ballast tank or hold can condense in the line or on the optics, and condensation isn’t an acceptable way to condition a sample. Our <a href="https://alrightes.com/case-study-consilium-sw2020-analyser-pump-leakage-singapore/">case study on a Consilium SW2020 analyser</a> is a different instrument, but it shows how a fault can sit in the sample path rather than the sensor.</p><p><strong>Getting the zero right</strong></p><p>The zero is where CO₂ calibration differs most from the other channels. Clean outdoor air isn’t CO₂-free. NOAA’s measurements put the global background at 425.62 ppm in 2025, and it’s still rising by around 2 ppm a year.</p><p>Manufacturers handle this differently, which is why the manual matters:</p><figure><img alt="CO₂ Sensors on Marine Gas Detectors: Why NDIR, and How They’re Calibrated" src="https://cdn-images-1.medium.com/max/693/1*NYd9c0YbXsmq8cX-gJLfnA.png" /></figure><p>The MSA approach assumes fresh air holds 300 ppm. Today’s background is closer to 425 ppm, so there’s a built-in offset of roughly 125 ppm, which is small against a 5,000 ppm limit. The bigger risk is where the zero gets done. Run a fresh-air zero in a closed control room or a crowded mess where CO₂ is at 1,500 ppm, and the instrument may read low by around 0.12% vol for the rest of its service. That’s nearly a quarter of the entry limit. Zeroing with <a href="https://alrightes.com/products/n2-pure-nitrogen-99-995vol-balance-air/">high-purity nitrogen</a> takes the room out of the equation, where the manual allows it.</p><p><strong>Matching the span gas</strong></p><p>The span step sets the sensor’s sensitivity against a known concentration, and two mistakes are easy to make.</p><p>The first is using the wrong mix. The four-gas cylinder most ships hold, such as <a href="https://alrightes.com/products/4-mix-co-50ppm-h2s-25ppm-2-5-ch450lel-12-o2-balance-n2/">CO 50 ppm, H₂S 25 ppm, methane at 50% LEL and 12% O₂ in nitrogen</a>, contains no CO₂ at all. It can’t bump-test or span the fifth channel. The Isle of Man notice says plainly that span gas for any CO₂ meter should be supplied to the vessel.</p><p>The second is a mismatch between the cylinder and the instrument’s programmed span value. If the detector expects 2.5% CO₂ and someone connects a 3% cylinder without changing the setting, the calibration will “pass” and leave the channel reading wrong. MSA lets you change span values through its software when you’re using different cylinders, and other makers have similar settings. Either buy the concentration the manual names, or change the setting to match the cylinder you have. We supply <a href="https://alrightes.com/products/1-3-5-10-15-carbon-dioxide-bal-n2/">CO₂ span gas in nitrogen</a> at 1%, 3%, 5%, 10% and 15%, and other <a href="https://alrightes.com/products/calibration-gas-mixtures-specialty-gases/">calibration gas mixtures</a> can include CO₂. Check the cylinder’s certificate of analysis and expiry date either way.</p><p><strong>Bump test, calibration and who does them</strong></p><p>A bump test exposes the sensor to gas to show it responds and the alarm sounds. A calibration measures the error against certified gas, adjusts it, and records the as-found and as-left values. We’ve written up <a href="https://alrightes.com/bump-test-vs-full-calibration-psc/">what a bump test can and can’t prove</a>, and the difference matters most on a channel the crew hasn’t worked with before.</p><p>No IMO document sets a calibration interval for portable detectors. MSC.1/Circ.1477 leaves it to the manufacturer’s instructions, and MSC.581(110) asks only for “properly calibrated” equipment. Your SMS sets the schedule, and our <a href="https://alrightes.com/marine-instrument-calibration-interval-table-singapore/">marine instrument calibration interval table</a> is a reasonable starting point.</p><p>Flags differ on where the work happens. Transport Malta accepts calibration at a manufacturer’s approved shore facility as a suitable means under SOLAS XI-1/7, while the Isle of Man expects regular CO₂ bump testing on board with span gas supplied. Plenty of SMSs combine the two, with crew bump tests between full calibrations. If class or a charterer asks about the calibrating lab, our note on <a href="https://alrightes.com/iso-17025-vs-manufacturer-calibration-which-does-class-accept/">manufacturer versus ISO 17025 calibration</a> covers what’s usually accepted.</p><p><strong>What the certificate should show for CO₂</strong></p><p>A CO₂ line on a calibration certificate is worth very little without the detail behind it. These are the fields to check:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/699/1*Z4hhxFGgblONYu1vHaO7SQ.png" /></figure><p>For how inspectors read these documents, see <a href="https://alrightes.com/marine-calibration-certificates-what-psc-inspectors-look-for/">what PSC inspectors look for on marine calibration certificates</a>.</p><p><strong>A CO₂ channel check before your next port call</strong></p><ol><li>Find the CO₂ zero and span instructions in each detector’s manual, and note the span concentration it expects.</li><li>Confirm the ship holds that CO₂ span gas, in date, and not only a four-gas mix.</li><li>Check the span value programmed in each detector matches the cylinder.</li><li>If the crew zero in fresh air, make sure they do it outdoors on deck, not in an enclosed room.</li><li>Inspect sampling hoses and filters for moisture after use in wet spaces.</li><li>Check that the last calibration certificate lists the CO₂ channel with as-found and as-left readings.</li></ol><p><strong>Calibrating CO₂ channels in Singapore</strong></p><p>Our <a href="https://alrightes.com/gas-detector-calibration-in-singapore/">gas detector calibration service in Singapore</a> covers infrared CO₂ sensors on 5-gas and single-gas instruments, on board alongside or at anchorage, with certificates showing as-found and as-left readings for every sensor. It’s part of our <a href="https://alrightes.com/services/#ship-fixed-portable">fixed and portable measurement equipment services</a>. If you’re choosing new equipment, the <a href="https://alrightes.com/products/co2-gas-detector-k-600m-built-in-pump-5-in-1-available-with-2-category-co2-ir-sensor-catalytic-sensor/">K-600M pumped 5-in-1 detector</a> uses an IR CO₂ sensor over a 0 to 5% range. NDIR is the same technology used in scrubber analysers, and our <a href="https://alrightes.com/egcs-scrubber-analyser-calibration-in-singapore-so2-co2-compliance-under-marpol-annex-vi/">EGCS analyser calibration guide</a> covers that side. <a href="https://alrightes.com/contact-us/">Send us your detector models and the span gas you carry</a> and we’ll confirm what matches before we attend.</p><p>Going back to the 3% CO₂ example at the start, the O₂ sensor would have shown 20.3% and stayed quiet. The CO₂ channel is the only thing on the instrument that would have caught it, which is a good reason to make sure its zero and span are right.</p><p><em>Read the original article on </em><a href="https://alrightes.com/co2-sensor-marine-gas-detector-calibration/"><em>Alright Engineering Solutions</em></a><em>.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=235e37066aea" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[IMO MSC.581(110) Explained: The 5-Gas Enclosed Space Entry Rule and Your Detectors]]></title>
            <link>https://medium.com/@alrightservices1118/imo-msc-581-110-explained-the-5-gas-enclosed-space-entry-rule-and-your-detectors-05523777f75c?source=rss-7d8af35bd2a9------2</link>
            <guid isPermaLink="false">https://medium.com/p/05523777f75c</guid>
            <category><![CDATA[marine]]></category>
            <category><![CDATA[ship]]></category>
            <category><![CDATA[5-gas]]></category>
            <category><![CDATA[singapore]]></category>
            <category><![CDATA[gas-detectors]]></category>
            <dc:creator><![CDATA[Alrightservices]]></dc:creator>
            <pubDate>Wed, 18 Nov 2026 12:19:31 GMT</pubDate>
            <atom:updated>2026-11-18T12:19:31.025Z</atom:updated>
            <content:encoded><![CDATA[<p>The “5-gas rule” is shorthand. Here’s what MSC.581(110) actually says about CO₂, oxygen-depleted spaces and detector calibration.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*xqX9sHzcSGdgaM4HTsKqdA.png" /></figure><p><em>Originally published on </em><a href="https://alrightes.com/msc-581-110-5-gas-requirement/"><em>Alright Engineering Solutions</em></a></p><p>InterManager’s figures, submitted to the IMO, show 14 enclosed space incidents in 2022 and another 14 in 2023. Deaths in those incidents rose from 18 to 34. That jump sits behind IMO Resolution MSC.581(110), and it’s why superintendents are asking whether their 4-gas meters are still good enough. A 4-gas meter can show a clean oxygen, LEL, CO and H₂S reading in a hold where carbon dioxide is already above the new entry limit. What the resolution actually asks for isn’t quite the “MSC.581(110) 5 gas requirement” you’ll see quoted online.</p><p><strong>What MSC.581(110) changed for atmosphere testing</strong></p><p>The Maritime Safety Committee adopted MSC.581(110), the Revised Recommendations for Entering Enclosed Spaces Aboard Ships, on 27 June 2025. It took effect on 3 December 2025 after the IMO Assembly endorsed it, and it replaces Resolution A.1050(27).</p><p>The change that matters most for detectors is in paragraph 7.4. Before anyone enters, the resolution asks for steady readings of all of the following:</p><figure><img alt="IMO MSC.581(110) Explained: The 5-Gas Enclosed Space Entry Rule and Your Detectors" src="https://cdn-images-1.medium.com/max/700/1*y8FFNX43sz6qWmwJlvESTg.png" /></figure><p>If the readings fall short, paragraph 7.5 says to ventilate further and retest after a suitable interval. Testing should be done with ventilation stopped (7.6), and the sample permit in Appendix 2 suggests stopping it for about 10 minutes first. The resolution also warns that oxygen and flammability readings tell you nothing about toxicity (7.7), and that oxygen-deficient pockets should always be suspected (7.8).</p><p>Once people are inside, the atmosphere should be tested frequently (8.1), and personal detectors should monitor oxygen, carbon dioxide, flammable gases or vapours and toxic gases including carbon monoxide (8.2). After a break, the space has to be retested before anyone goes back in (8.3), and single-person entry isn’t permitted at all.</p><p><strong>Where the “5-gas” label comes from</strong></p><p>Plenty of pages say MSC.581(110) requires a five-gas detector, though they don’t agree on which five. The resolution itself doesn’t use the phrase, and it doesn’t mention hydrogen sulphide anywhere.</p><p>What it names is oxygen, CO₂, flammables, toxic gases including CO, and any other gas the risk assessment identifies for that space or cargo. H₂S comes in from a different document. SOLAS regulation XI-1/7, in force since 1 July 2016, requires ships to carry a portable atmosphere testing instrument that can measure, as a minimum, oxygen, flammable gases or vapours, hydrogen sulphide and carbon monoxide, with suitable means of calibrating it. MSC.1/Circ.1477, the IMO’s guidelines for selecting that instrument, uses the same four.</p><p>So “5-gas” is shorthand for SOLAS’s four plus the CO₂ limit in MSC.581(110). A CO₂-capable multi-gas unit covering all five is the tidiest way to satisfy both documents with one instrument, but it doesn’t cover everything. If the risk assessment for a cargo flags ammonia, phosphine or benzene, a five-gas meter won’t see them, and you’ll need another sensor, detector tubes or a separate instrument.</p><p>It’s worth being fair to the 4-gas meter here. For nearly a decade it was exactly what SOLAS and Circ.1477 asked for, and buying one was the sensible decision. It still covers the SOLAS minimum today. What it can’t do is give you the CO₂ reading paragraph 7.4.2 asks for, so it needs a CO₂ instrument alongside it or a replacement with the channel built in. ABS’s guidance on the resolution describes the options as replacing or supplementing existing detectors, which is fairer than the “non-compliant” label some sales pages use. We set out the wider SOLAS picture in our earlier guide to <a href="https://alrightes.com/portable-gas-detector-calibration-in-singapore-imo-solas-requirements/">portable gas detector calibration under IMO and SOLAS</a>.</p><p><strong>Is it a requirement or a recommendation?</strong></p><p>MSC.581(110) is a set of recommendations. The resolution invites governments to bring it to the attention of shipowners; it doesn’t amend SOLAS. It gets legal force when a flag state writes it into national rules.</p><p>Denmark is a clear example. The Danish Maritime Authority implemented MSC.581(110) through Order no. 472 from 1 July 2026, then gave Danish-flagged ships until 1 December 2026 to acquire portable CO₂ detection devices because of limited availability and long delivery times. The authority was explicit that the extension didn’t relax anything else in the resolution.</p><p>A sharp reader will point out that if your flag hasn’t legislated, you’re technically still working to SOLAS XI-1/7 alone. That’s true as far as it goes. In practice, class societies including ABS, DNV and LR have told owners to update their safety management systems against MSC.581(110), taking their flag’s requirements into account, and the Tokyo MOU has announced a joint concentrated inspection campaign with the Paris MoU on enclosed space entry for 2027. Singapore’s MPA listed the resolution among the MSC 110 outcomes in Shipping Circular №07 of 2025. Check your own flag’s circulars rather than assuming either way.</p><p><strong>The ship’s instrument and the personal detector do different jobs</strong></p><p>Two kinds of detector show up in these documents. The SOLAS XI-1/7 instrument is ship’s equipment. It tests the space from outside before anyone goes in, usually drawing a sample through a hose with a pump. Circ.1477 says plainly that its guidelines don’t cover a personal detector carried by someone inside the space.</p><p>The personal detector is what paragraph 8.2 is about. It goes in with the entrant and alarms if conditions change while they’re working. A clip-on single-gas monitor such as a <a href="https://alrightes.com/products/bell-mini-single-gas-detector-o2/">BELL MINI O₂ detector</a> does that job for one hazard, which is why it can’t stand in for a multi-gas unit with a CO₂ channel.</p><p>On numbers, paragraph 7.3 says all ships should carry at least two sets of gas detection equipment as required by SOLAS XI-1/7. Ships carrying cargoes that can create a hazardous atmosphere, and that need regular entry for inspection or cleaning, should carry two more. The four-set figure applies to that cargo category, not to every ship. Fixed systems in pump rooms and compressor rooms are a separate subject, covered in our guide to <a href="https://alrightes.com/fixed-gas-detection-calibration-for-chemical-tankers-oil-tankers-lpg-and-lng-carriers/">fixed gas detection calibration for tankers and gas carriers</a>.</p><p><strong>Paragraph 7.1, and why some sensors struggle in thin air</strong></p><p>Paragraph 7.1 says gas detection equipment, including CO₂ devices, should be capable of operating correctly even in an oxygen-depleted atmosphere. That’s a statement about sensor physics.</p><p>Most portable LEL channels use a catalytic bead, or pellistor, which measures flammable gas by burning it on a heated catalyst. It needs oxygen to do that, and one manufacturer gives a minimum of about 10% by volume. In a depleted or inerted space the bead can’t oxidise all the gas present, so the %LEL figure reads low, and a low reading there isn’t proof the space is free of flammables. Infrared LEL sensors don’t need oxygen, but they can’t see hydrogen, so the right choice depends on what the space might hold. The oxygen analyser on an inert gas plant is a different instrument again, covered in our guide to <a href="https://alrightes.com/oxygen-analyser-calibration-for-inert-gas-systems/">oxygen analyser calibration for inert gas systems</a>.</p><p>CO₂ is almost always measured by non-dispersive infrared (NDIR). The reading depends on the pressure, temperature and humidity of the gas reaching the optical cell, and it still drifts over months of use. Oxygen, CO and H₂S are usually electrochemical cells, which have a finite life and lose sensitivity as they age.</p><figure><img alt="IMO MSC.581(110) Explained: The 5-Gas Enclosed Space Entry Rule and Your Detectors" src="https://cdn-images-1.medium.com/max/702/1*vLLCSrgbRlOnAnN9ANG_sA.png" /></figure><p>If you’re choosing a replacement, look at the sensor list before the gas count. The <a href="https://alrightes.com/products/co2-gas-detector-k-600m-built-in-pump-5-in-1-available-with-2-category-co2-ir-sensor-catalytic-sensor/">K-600M pumped 5-in-1 detector</a>, for example, uses an IR sensor for CO₂ over a 0 to 5% range and comes with either an IR or a catalytic sensor for methane. The full range is on our <a href="https://alrightes.com/product-category/portable-gas-detectors/">portable gas detectors</a> page. If you’re keeping existing meters, an <a href="https://alrightes.com/gas-detector-calibration-in-singapore/">onboard gas detector calibration</a> visit records as-found readings for each channel, which shows quickly whether drift is a problem.</p><p><strong>Calibrating the fifth channel</strong></p><p>Neither SOLAS nor the resolution sets a calibration interval. Circ.1477 says the manufacturer’s instructions should define clear calibration requirements, and the interval follows the manufacturer. MSC.581(110) asks for “properly calibrated” equipment (7.2 and 6.5.3) and crew training in calibration (3.6). Your SMS sets the actual schedule, and our <a href="https://alrightes.com/marine-instrument-calibration-interval-table-singapore/">marine instrument calibration interval table</a> is a reasonable starting point if you’re building one.</p><p>Adding a CO₂ channel changes the calibration kit. The quad mix many ships hold, such as <a href="https://alrightes.com/products/4-mix-co-50ppm-h2s-25ppm-2-5-ch450lel-12-o2-balance-n2/">CO 50 ppm, H₂S 25 ppm, methane at 50% LEL and 12% O₂ in nitrogen</a>, has no CO₂ in it, so it can’t bump-test or span the fifth sensor. You’ll need a <a href="https://alrightes.com/products/1-3-5-10-15-carbon-dioxide-bal-n2/">CO₂ span gas in nitrogen</a>, sold in concentrations from 1% to 15%, or a mix that includes CO₂, matched to whatever the detector’s manual specifies. <a href="https://alrightes.com/products/n2-pure-nitrogen-99-995vol-balance-air/">Pure nitrogen</a> is handy for zeroing the O₂ cell.</p><p>A bump test and a calibration aren’t the same thing either. A bump test exposes the sensors to gas to confirm they respond and alarm, while a calibration measures the error against certified gas and corrects it. Neither MSC.581(110) nor Circ.1477 mentions bump testing, so its frequency comes from the manufacturer and your SMS. We’ve written separately about <a href="https://alrightes.com/bump-test-vs-full-calibration-psc/">what a bump test can and can’t prove</a>.</p><p>When a detector comes back from calibration, the certificate should list every channel, CO₂ included, with as-found and as-left readings, calibration gas concentrations, cylinder lot numbers and expiry dates, the alarm set points tested and the next due date. We cover that detail in <a href="https://alrightes.com/marine-calibration-certificates-what-psc-inspectors-look-for/">what PSC inspectors look for on marine calibration certificates</a>.</p><p><strong>A readiness check before your next Singapore call</strong></p><ol><li>List every portable and personal detector on board with make, model and fitted sensors, and mark which ones have a CO₂ channel.</li><li>Check the LEL sensor type on each multi-gas unit against the spaces you enter, especially inerted tanks and holds with oxygen-depleting cargo.</li><li>Count your sets against paragraph 7.3, including the extra two if your cargoes call for regular entry.</li><li>Confirm your span gas covers CO₂ and that the cylinders are in date.</li><li>Check that the latest calibration certificates name every sensor, with as-found and as-left data.</li><li>Record the testing means for each space in the Enclosed Space Register, as paragraph 4.2 asks.</li><li>Read your flag’s latest circular on MSC.581(110) so you know whether it’s law or guidance for your ships.</li></ol><p><strong>Getting your detectors checked in Singapore</strong></p><p>Our <a href="https://alrightes.com/gas-detector-calibration-in-singapore/">gas detector calibration service in Singapore</a> covers portable, personal and fixed detectors on board, alongside or at anchorage, with certificates showing as-found and as-left readings for each sensor, and it’s part of our <a href="https://alrightes.com/services/#ship-fixed-portable">fixed and portable measurement equipment services</a>. <a href="https://alrightes.com/contact-us/">Send us your detector makes, models and sensor lists</a> and we’ll tell you which units can cover the CO₂ limit and which need attention before you sail.</p><p>As for the 4-gas meter from the start, it may well be reading accurately. It just can’t see the gas MSC.581(110) added, and on a ship carrying grain, logs or coal, CO₂ is often one of the gases building up behind a closed hatch.</p><p><em>Read the original article on </em><a href="https://alrightes.com/msc-581-110-5-gas-requirement/"><em>Alright Engineering Solutions</em></a><em>.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=05523777f75c" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Oxygen Analyser Calibration for Inert Gas Systems]]></title>
            <link>https://medium.com/@alrightservices1118/oxygen-analyser-calibration-for-inert-gas-systems-e9fcff924afb?source=rss-7d8af35bd2a9------2</link>
            <guid isPermaLink="false">https://medium.com/p/e9fcff924afb</guid>
            <category><![CDATA[ship]]></category>
            <category><![CDATA[calibration]]></category>
            <category><![CDATA[oxygen-analyser]]></category>
            <category><![CDATA[mariners]]></category>
            <category><![CDATA[vessel]]></category>
            <dc:creator><![CDATA[Alrightservices]]></dc:creator>
            <pubDate>Mon, 26 Oct 2026 02:31:01 GMT</pubDate>
            <atom:updated>2026-11-18T04:01:25.344Z</atom:updated>
            <content:encoded><![CDATA[<p>When the oxygen reading is wrong, the inert gas is too</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*ebNqAebyK3DYyuEHcUGfFw.png" /></figure><p><em>Originally published on </em><a href="https://alrightes.com/oxygen-analyser-calibration-for-inert-gas-systems/"><em>Alright Engineering Solutions</em></a></p><p>An inert gas system exists to keep the cargo tank atmosphere out of the flammable range, and the oxygen analyser is the instrument that tells everyone whether it’s working. If that reading is off, the crew is deciding about inerting, purging, and cargo operations on bad information. The chain is short. An inaccurate reading can mean an unsafe atmosphere, and even in the best case it means a SIRE observation, a delayed cargo operation, or closer PSC attention.</p><p>That’s why oxygen analyser calibration isn’t a routine housekeeping job. It’s a safety-critical one, and inspectors treat it that way. This guide covers what the rules require, why the type of analyser matters, where marine analysers go wrong, and how to get one calibrated in Singapore without losing the cargo window.</p><p><strong>The 5% Rule and the 24-Hour Check</strong></p><p>Under SOLAS and the FSS Code, an inert gas system has to deliver inert gas to the cargo tanks with no more than 5% oxygen by volume at the required flow rate. OCIMF guidance explains the thinking behind the numbers: keeping a positive tank pressure and an atmosphere below 8% oxygen makes the tank atmosphere non-flammable, and the 5% limit at the delivery main is the stricter design requirement that gives a margin.</p><p>SIRE guidance adds a timing expectation. The fixed oxygen analyser should be calibrated not more than 24 hours before the inert gas system is started, and records should show calibration before each cargo, purging, or inerting operation. Inspectors also tend to check whether the local and remote oxygen recorders agree, whether span gas is on board, and whether the officers can explain how the analyser is operated and calibrated.</p><p>There are two different jobs hiding in that paragraph. The pre-use calibration is the crew’s routine, done with onboard gas before each operation. The periodic calibration, repair, and certification by an accredited provider is a separate job, and it’s the one that gives the crew’s routine something trustworthy to stand on. Both need to be in order.</p><p><strong>Zirconia vs. Paramagnetic: Know What’s Fitted</strong></p><p>“Oxygen analyser” covers two quite different instruments, and treating them the same is a common source of calibration errors. The manual and nameplate will tell you which one you have.</p><figure><img alt="Zirconia vs. Paramagnetic: Know What’s Fitted" src="https://cdn-images-1.medium.com/max/703/1*y5DB7n6CJnFdxFoo35yzxw.png" /></figure><p><strong>Why Marine Analysers Drift</strong></p><p>Most analyser problems at sea come from a short list of causes. Soot builds up on sensing surfaces in combustion gas. Zirconia elements crack when heated or cooled too quickly. Condensate collects in sample lines and corrodes fittings or skews readings. Vibration wears on mechanical sensing parts. Span gas passes its expiry date, or the wrong gas gets used for the wrong step.</p><p>Sample lines deserve special attention, because a perfectly healthy analyser can read wrongly behind a failing sample path. A small leak that draws in outside air pushes the oxygen reading up, which is the opposite of what an inert gas system needs to see. We’ve traced a <a href="https://alrightes.com/case-study-consilium-sw2020-analyser-pump-leakage-singapore/">sampling-path fault on a Consilium SW2020 analyser</a> that looked fine at the sensor and wasn’t, and the same logic applies here: calibrating the analyser doesn’t prove the line feeding it is sound.</p><p>Gas matters just as much. Other gases in the sample, including the CO₂ present in flue-gas-based inert gas, can affect some analyser designs, so following the manufacturer’s procedure and using the right reference gases isn’t optional.</p><p><strong>Zeroing and Spanning: What Inspectors Watch For</strong></p><p>The practical sequence for most paramagnetic analysers is simple. Zero against an oxygen-free gas such as <a href="https://alrightes.com/products/n2-pure-nitrogen-99-995vol-balance-air/">high-purity nitrogen</a>, let the reading stabilise, then check span against fresh air at 20.9% oxygen or a certified <a href="https://alrightes.com/products/20-9-oxygen-bal-n2/">20.9% oxygen span gas</a>. The manufacturer’s procedure always has the final word, and the readings at each step should be written down.</p><p>A single check at 20.9% tells you the analyser works at the top of its range, but the number that matters operationally is near 5%. Where the manufacturer’s procedure allows it, a mid-range check against a gas close to the limit, such as a <a href="https://alrightes.com/products/5-5-oxygen-bal-n2/">5.5% oxygen mix</a>, shows whether the analyser reads correctly where the decision actually gets made. A broader range of <a href="https://alrightes.com/products/calibration-gas-mixtures-specialty-gases/">certified calibration gases</a> is useful to have onboard for this reason.</p><p>Inspectors tend to ask crews to explain the steps. An officer who can say what gas is used at each stage, why, and how the readings were recorded is showing the human side of compliance, and it counts for as much as the certificate.</p><p><strong>What an Audit-Ready Calibration Record Contains</strong></p><p>A certificate that just says “calibrated” isn’t enough. A useful record shows the date and time, the reference gases used (concentration, cylinder identification, and expiry), the as-found and as-left readings, the tolerance or measurement uncertainty, who did the work, and the traceability of the reference standards.</p><p>If a laboratory carries out the calibration, check its accreditation scope too. SAC-SINGLAS accredits laboratories against ISO/IEC 17025 for specific tests and calibrations, and accreditation covers only what’s listed in the lab’s stated scope. A lab accredited for pressure gauges isn’t automatically accredited for oxygen analysers. The difference between a quick function check and a full calibration comes up constantly in inspections, and we’ve written about <a href="https://alrightes.com/bump-test-vs-full-calibration-psc/">how bump testing and full calibration differ</a> under PSC scrutiny.</p><p><strong>Getting It Done in Singapore</strong></p><p>Timing is where Singapore calls get tight. A ship at anchor has a narrow window between arrival and the next cargo, purging, or inerting operation, and an analyser that needs repair or shore-side calibration has to fit inside it. Agree collection, calibration, certification, and return with the provider before the vessel arrives, not after the problem shows up, and keep a spare, in-date supply of zero and span gas onboard for the pre-use routine.</p><p>A structured <a href="https://alrightes.com/marine-instrument-calibration-interval-table-singapore/">calibration interval schedule</a> helps here, because it shows well ahead of arrival when the periodic calibration falls due. Our <a href="https://alrightes.com/services/#ship-fixed-portable">fixed and portable measurement equipment calibration service</a> handles the shore-side side of this, and our <a href="https://alrightes.com/services/#ship-fixed-measurements">fixed measurement and automation service</a> covers fixed analysers and their sample systems.</p><p><strong>Before the Next Inerting Operation</strong></p><ol><li>Confirm which type of analyser is fitted, and keep the manufacturer’s calibration procedure at hand.</li><li>Check zero and span gas cylinders against their expiry dates.</li><li>Run and record the pre-use calibration within the 24-hour window, with readings at each step.</li><li>Check the sample line for leaks, condensate, and blockages, and compare local and remote oxygen readings.</li><li>Confirm the periodic shore-side certificate is in date, shows as-found and as-left data, and comes from a provider whose accreditation scope covers oxygen analysers.</li></ol><p><em>Read the original article on </em><a href="https://alrightes.com/oxygen-analyser-calibration-for-inert-gas-systems/"><em>Alright Engineering Solutions</em></a><em>.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=e9fcff924afb" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Oil Mist Detector Calibration and Testing in Singapore: MK5, MK6 and MK7 Service Guide]]></title>
            <link>https://medium.com/@alrightservices1118/oil-mist-detector-calibration-and-testing-in-singapore-mk5-mk6-and-mk7-service-guide-8146a010ae31?source=rss-7d8af35bd2a9------2</link>
            <guid isPermaLink="false">https://medium.com/p/8146a010ae31</guid>
            <category><![CDATA[mk6]]></category>
            <category><![CDATA[mk7]]></category>
            <category><![CDATA[oil-mist]]></category>
            <category><![CDATA[oil-mist-detector]]></category>
            <category><![CDATA[mk-5]]></category>
            <dc:creator><![CDATA[Alrightservices]]></dc:creator>
            <pubDate>Sun, 25 Oct 2026 02:31:01 GMT</pubDate>
            <atom:updated>2026-10-25T02:31:01.976Z</atom:updated>
            <content:encoded><![CDATA[<p>Pressing the test button isn’t a calibration</p><figure><img alt="Oil Mist Detector Calibration and Testing in Singapore: MK5, MK6 and MK7 Service Guide" src="https://cdn-images-1.medium.com/max/1024/1*pL4XZBkD8ZGDD32x3jWkIA.png" /></figure><p><em>Originally published on </em><a href="https://alrightes.com/oil-mist-detector-calibration-and-testing-in-singapore-mk5-mk6-and-mk7-service-guide/"><em>Alright Engineering Solutions</em></a></p><p>An oil mist detector is an early warning for one of the worst events in an engine room, a crankcase explosion. It works by sampling the crankcase atmosphere, measuring how dense the oil mist is, and raising an alarm or triggering a slowdown before the concentration gets dangerous. If the optics are coated, a sample line is blocked, or the alarm point has drifted, the warning comes late or not at all, and nothing about the front panel necessarily shows it.</p><p>That’s why servicing an OMD is a safety job as much as a compliance one. This guide covers what the rules expect, what the different levels of testing actually prove, how the Graviner MK5, MK6 and MK7 differ in practice, and what a service report should show when a surveyor or PSC officer asks for it.</p><p><strong>What SOLAS and IACS Expect</strong></p><p>SOLAS Chapter II-1, Regulation 47(2) calls for crankcase oil mist detectors, bearing temperature monitors, or equivalent devices on larger diesel engines. The threshold in the regulation is engines of 2,250 kW or above, or with a cylinder bore greater than 300 mm.</p><p>IACS UR M67 sets the performance requirements for the equipment itself. The alarm has to be set at no more than 5% of the lower explosive limit, which works out to roughly 2.5 mg/l of oil mist in air. That figure is the reason set-point integrity matters. Anything that quietly moves the alarm point upward moves the warning later.</p><p>It helps to separate two ideas here. Type approval under UR M67 shows that a design performs as required in a test setting. Routine servicing is how you keep an installed system performing that way. The manufacturer’s manual and the vessel’s planned maintenance system define the second part, and a surveyor will usually want to see both.</p><p><strong>How the System Works</strong></p><p>An OMD pulls samples from individual crankcase compartments through sampling pipes and measures the mist density, commonly by optical obscuration or light scattering. Many designs compare the sample against a clean reference path, so the reading reflects mist and not just a dirty lens. If the concentration passes the alarm point, the system raises an alarm and, depending on the installation, signals an engine slowdown or shutdown.</p><p>The chain is simple: sample, measure, compare, alarm, record. Every link depends on something physical, such as a clear sampling path, a clean optical surface, a working pump or blower, and an alarm point that’s still where it was set. A good service looks at all of them, and a poor one checks only the last.</p><p><strong>Testing Versus Calibration</strong></p><p>A service can mean several different things, and it helps to know which one you’ve bought. Roughly from simplest to most thorough:</p><p>A visual and functional check confirms power, self-test, display, communications, and alarm indication. A test with an OEM-approved test kit confirms that a detector head responds to a known test medium. A zero or sensitivity verification checks the baseline condition and response against the manufacturer’s procedure. An alarm set-point verification confirms that the configured alarm still sits within the approved limits, which is what protects the 5% LEL principle. A full calibration may go further, using approved equipment to generate controlled reference conditions, and it may need authorized service support depending on the model.</p><p>The important point is that these aren’t interchangeable. A self-test button confirms the electronics are alive. It doesn’t tell you whether the optics are clean, whether a sample line is open, or whether the alarm would trigger at the right concentration. The same distinction between a quick check and a full calibration comes up in gas detection, and we’ve written about <a href="https://alrightes.com/bump-test-vs-full-calibration-psc/">how bump testing and full calibration differ</a> under PSC scrutiny.</p><p>Test method matters as well. Use the manufacturer’s test kit and procedure and not an improvised aerosol, because a poorly executed test can leave residue on the optics and cause the very problem you’re checking for.</p><p><strong>MK5, MK6 and MK7: Same Aim, Different Details</strong></p><p>The compliance objective is shared across the Graviner generations, but the hardware, test kit, alarm logic, and serviceable parts differ by model. Treat the table below as a guide to emphasis, and follow the manual for the model you have.</p><figure><img alt="MK5, MK6 and MK7: Same Aim, Different Details" src="https://cdn-images-1.medium.com/max/707/1*Tm0f8fzrRK4sDSdCH6HqGw.png" /></figure><p>Other makes exist too, such as the <a href="https://alrightes.com/products/visatron-vn115-87-plus-oil-mist-detection-system/">Visatron VN115/87 Plus</a>, and the same principles apply even where the procedures don’t.</p><p><strong>Why Detectors Give False Alarms or Miss Real Ones</strong></p><p>Most faults come from a short list. An oil film or soot on the optics cuts the light and shifts the reading. Sampling pipes get blocked, kinked, or develop leaks, and moisture condenses in them. A detector head fails or its light source degrades. A pump or blower weakens, so the sample isn’t moving as it should. After a board replacement or a software change, an alarm setting can end up somewhere other than where it should be. And a careless test can contaminate the very parts it’s meant to check.</p><p>False alarms and missed alarms often share a root cause, which is why a service that only silences nuisance alarms isn’t a fix. A fouled optical path can drive both, one by triggering spurious alarms, the other by hiding a real one. Our range includes the parts that tend to wear, from <a href="https://alrightes.com/products/graviner-mk6-main-pcb-44782-k071-02/">main boards</a> to <a href="https://alrightes.com/products/graviner-mk6-lcd-display-43785-k120/">LCD displays</a>, along with a <a href="https://alrightes.com/products/graviner-commissioning-kit-part-no-d9221-026/">Graviner commissioning kit</a> and <a href="https://alrightes.com/products/graviner-service-kit-part-no-d9221-027/">service kit</a>.</p><p><strong>What a Service Report Should Contain</strong></p><p>A report that says “tested OK” gives a surveyor little to go on. A useful one names the vessel, the engine, the OMD make and model, the serial numbers, and the detector head locations. It shows the date, the technician, and the manufacturer’s procedure used. It records the visual inspection, the condition of the heads and sampling lines, the functional test result, the response to the test kit, and the verification of the alarm set point. It gives the as-found and as-left condition, lists any parts replaced, and shows the next service due date with a sign-off.</p><p>If a failed part gets replaced, the report should say so, because a swapped board or head can shift settings. That ties the paperwork back to the set-point question from the start.</p><p><strong>How Often</strong></p><p>The manual, the vessel’s PMS, and class requirements decide the interval. Many providers describe an annual full service as standard practice, with more frequent checks depending on operating hours and engine condition. A pattern that’s common in practice is a regular built-in self-test, periodic inspection and cleaning of the heads and sample path, an annual full service, and immediate verification after an alarm event, major engine maintenance, or any component replacement. Treat that as a starting point and not a rule, and set the actual frequencies in the PMS.</p><p>A structured <a href="https://alrightes.com/marine-instrument-calibration-interval-table-singapore/">calibration interval schedule</a> is a handy way to keep the OMD on the same visible calendar as the rest of the vessel’s instruments.</p><p><strong>Getting It Done in Singapore</strong></p><p>Singapore calls are short, so it pays to sort out the details before arrival: which OMD model and how many heads, what spares and test kit are on board, when the last full service happened, and who’s attending. A good visit inspects and cleans the heads and sample lines, runs the manufacturer’s tests, verifies the alarm points, replaces what’s worn, and leaves a report the Chief Engineer can file straight away.</p><p>Several Singapore providers advertise MK5, MK6 and MK7 support, so the difference comes down to technical depth and the quality of the paperwork. Our <a href="https://alrightes.com/services/#ship-fixed-measurements">fixed measurement and automation service</a> and <a href="https://alrightes.com/services/#ship-fixed-portable">fixed and portable measurement equipment calibration service</a> cover instrument work for vessels calling at Singapore.</p><p><strong>Before the Next Survey or Inspection</strong></p><ol><li>Check the OMD’s last service date against the PMS and the manufacturer’s manual.</li><li>Confirm the service report shows the alarm set point verified, not just a functional test.</li><li>Inspect sampling pipes for kinks, leaks, and condensate, and the detector heads for oil film and soot.</li><li>Check that any part replaced since the last service is recorded, with settings reverified afterward.</li><li>Confirm the test kit on board is the manufacturer’s approved one for your model.</li></ol><p><em>Read the original article on </em><a href="https://alrightes.com/oil-mist-detector-calibration-and-testing-in-singapore-mk5-mk6-and-mk7-service-guide/"><em>Alright Engineering Solutions</em></a><em>.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=8146a010ae31" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Wash Water Monitoring: pH and PAH Sensor Calibration for Marine ScrubbersWash Water Monitoring: pH…]]></title>
            <link>https://medium.com/@alrightservices1118/wash-water-monitoring-ph-and-pah-sensor-calibration-for-marine-scrubberswash-water-monitoring-ph-d0d0fcb69216?source=rss-7d8af35bd2a9------2</link>
            <guid isPermaLink="false">https://medium.com/p/d0d0fcb69216</guid>
            <category><![CDATA[singapore]]></category>
            <category><![CDATA[ship]]></category>
            <category><![CDATA[wash-water-monitoring]]></category>
            <category><![CDATA[vessel]]></category>
            <dc:creator><![CDATA[Alrightservices]]></dc:creator>
            <pubDate>Sat, 24 Oct 2026 02:31:01 GMT</pubDate>
            <atom:updated>2026-10-24T02:31:01.750Z</atom:updated>
            <content:encoded><![CDATA[<h3>Wash Water Monitoring: pH and PAH Sensor Calibration for Marine ScrubbersWash Water Monitoring: pH and PAH Sensor Calibration for Marine Scrubbers</h3><p>A washwater sensor can look fine and still be wrong</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*ezIV3bhgl5e_9cBIJE3vjQ.png" /></figure><p><em>Originally published on </em><a href="https://alrightes.com/wash-water-monitoring-ph-and-pah-sensor-calibration-for-marine-scrubbers/"><em>Alright Engineering Solutions</em></a></p><p>A pH sensor can give a perfectly believable reading and still be off. A PAH monitor can report a steady, reassuring number through a window with a film nobody has cleaned. Neither fault announces itself, and a scrubber discharging through a drifted sensor can end up outside its limits, or unable to prove it stayed inside them.</p><p>Under the IMO’s EGCS guidelines, pH, PAH, turbidity, and temperature have to be monitored and recorded continuously whenever a scrubber operates in ports, harbours, or estuaries. This guide covers what each sensor is proving, how the pH and PAH calibrations differ, why the sensors drift at sea, and what a record needs to contain to satisfy an inspector.</p><p><strong>What the Monitoring System Measures</strong></p><p>Four parameters make up the washwater dataset, and each has a different job.</p><figure><img alt="Wash Water Monitoring: pH and PAH Sensor Calibration for Marine Scrubbers" src="https://cdn-images-1.medium.com/max/683/1*OCpnlz4IT_kwsm_G_cmWdw.png" /></figure><p>Turbidity and temperature matter more than they look. A turbidity sensor that’s drifted can quietly undermine a PAH reading, and a temperature error feeds straight into pH compensation.</p><p><strong>The Limits the Sensors Have to Prove</strong></p><p>The pH of the discharge has to be at least 6.5 at the overboard discharge. During manoeuvring and transit, the guidelines allow a maximum difference of 2 pH units between inlet and outlet instead. For PAH, the continuous concentration can’t exceed 50 µg/L PAHphe above the inlet water’s PAH, normalised to a washwater flow rate of 45 tonnes per MWh.</p><p>PAH isn’t a direct measure of oil. It’s a proxy: the instrument responds to fluorescence and reports the result as if the sample were phenanthrene. That’s why the calibration standard matters so much, because the number only means something relative to the standard behind it.</p><p>The guidelines also set a recording rate. pH, PAH, and turbidity have to be recorded at no less than 0.0111 Hz, which works out to roughly one reading every 90 seconds. A sensor that’s calibrated but logging with gaps still leaves a hole in the record.</p><p><strong>pH Calibration: Buffers, Slope, and Temperature</strong></p><p>The guidelines call for a pH electrode and meter with 0.1 pH unit resolution and temperature compensation. MPA Singapore’s circular on EGCS requirements also names standards for the electrode (BS 2586 or ASTM D1293–18) and the meter (IEC 60746–2:2003 or an equivalent), so it’s worth checking that the fitted equipment matches.</p><p>Calibration starts before any buffer comes out. Check the electrode for fouling, cracking, depleted electrolyte, and air bubbles, and clean it using the manufacturer’s method. Then calibrate against certified pH buffers, normally at least two points that span the range the sensor works in, following the manufacturer’s procedure. Verify the slope, the offset, the response time, and the temperature compensation, and record the as-found and as-left values.</p><p>The slope and offset checks are what separate a calibration from a quick look. A sensor can read plausibly in the middle of its range while its slope has drifted enough to be wrong at the 6.5 line, which is exactly where it needs to be right.</p><p><strong>PAH Calibration: Phenanthrene and the 5% Rule</strong></p><p>PAH monitors typically work by UV fluorescence, and the guidelines require them to be calibrated with phenanthrene, with results reported as PAHphe. The equipment has to measure up to at least twice the applicable discharge limit, and it has to stay accurate within 5% in discharge water whose turbidity is within the working range of the application.</p><p>Manufacturers set their own triggers for recalibration. One manufacturer’s manual says calibration is needed when validation deviates by more than 5% either way from the nominal standard concentration, where that concentration is at least 80% of the sensor range. Your sensor’s manual may say something different, so treat that as an example and not a universal rule.</p><p>The sensible order of work is simple. Clean and inspect first, then validate against the phenanthrene-equivalent standard, then recalibrate or replace if the reading falls outside tolerance, and finally write down the as-found and as-left results. Cleaning comes first for a reason: a fouled optical window can look exactly like a calibration problem, and calibrating over a dirty window just bakes the error in.</p><p><strong>Why pH and PAH Sensors Fail at Sea</strong></p><p>Washwater is rough on instruments. Deposits build up on pH electrodes. Biofouling, silt, and scale coat the optical windows of PAH sensors, and high turbidity interferes with fluorescence readings. Sample flow can be blocked, air bubbles can form, and pumps degrade. Temperature compensation can go wrong, standards can pass their expiry or get stored badly, and the data logger can have gaps or the wrong range configured.</p><p>Several of these are sample-path problems, not sensor problems, which is why the whole system needs checking and not just the probe. A different instrument, but the habits carry over: our walkthrough of <a href="https://alrightes.com/annual-ows-15ppm-calibration-on-a-fellow-kogyo-focas-1800-what-the-job-actually-involves/">an annual OWS 15ppm calibration on a Fellow Kogyo Focas 1800</a> shows how an oil-in-water monitor is cleaned, checked, and documented, and the same discipline applies here.</p><p><strong>What an Audit-Ready Calibration Record Contains</strong></p><p>A certificate that says “calibrated” isn’t enough. A useful record names the vessel, the EGCS unit, the sensor serial numbers, and the monitoring system model. It shows the date, time, and place, and who did the work. For pH, it gives the buffer lot numbers, values, and expiry dates, plus the slope, offset, and temperature compensation results. For PAH, it gives the standard’s concentration, its phenanthrene-equivalent value, and the certificate number and expiry. It records the as-found and as-left readings, the pass or fail decision against the tolerance, and any cleaning, repair, or replacement carried out. Finally, it points to the Record Book entry and the data logger confirmation.</p><p>Calibration and drift data have to end up either in the data-recording system or in the EGCS Record Book, as set out in the vessel’s Onboard Monitoring Manual. If an outside lab or service company does the work, check its accreditation scope as well. SAC-SINGLAS accredits calibration laboratories to ISO/IEC 17025, and only for the specific calibrations in a lab’s stated scope.</p><p><strong>How Often: The Manual Sets the Interval</strong></p><p>There isn’t a single interval that applies everywhere. Calibration frequency should follow the vessel’s Onboard Monitoring Manual and the sensor manufacturer’s instructions. Some manufacturers specify multi-year intervals for certain sensors, but a vessel shouldn’t wait that long after fouling, maintenance, an alarm event, or a reading that doesn’t look right. A structured <a href="https://alrightes.com/marine-instrument-calibration-interval-table-singapore/">calibration interval schedule</a> is a good way to keep the manual’s intervals visible and the extra checks on the calendar.</p><p><strong>Getting It Done in Singapore</strong></p><p>The practical approach is to settle the details before the ship arrives. Confirm which sensors and monitoring system are fitted, that the buffers and phenanthrene standards are in date, and when the last validation and calibration were done. A good visit cleans the sensors, checks the flow and sample path, validates pH and PAH against fresh standards, records the as-found and as-left readings, and leaves a record the Chief Engineer can file straight into the Record Book.</p><p>Our <a href="https://alrightes.com/services/#ship-fixed-portable">fixed and portable measurement equipment calibration service</a> and <a href="https://alrightes.com/services/#ship-fixed-measurements">fixed measurement and automation service</a> cover instrument work for vessels calling at Singapore.</p><p><strong>Before the Next Scrubber Operation</strong></p><ol><li>Check the Onboard Monitoring Manual and the sensor manuals for the calibration interval and validation tolerance on each sensor.</li><li>Inspect the pH electrode and the PAH optical window for fouling, deposits, and bubbles, and clean them per the manufacturer.</li><li>Check buffer and phenanthrene standards against their expiry dates and storage conditions.</li><li>Confirm the as-found and as-left readings are recorded, and that the entry is in the data system or the EGCS Record Book.</li><li>Check the data logger for gaps, and confirm turbidity and temperature are being recorded alongside pH and PAH.</li></ol><p><em>Read the original article on </em><a href="https://alrightes.com/wash-water-monitoring-ph-and-pah-sensor-calibration-for-marine-scrubbers/"><em>Alright Engineering Solutions</em></a><em>.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=d0d0fcb69216" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>