<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Communications Power Zone on Medium]]></title>
        <description><![CDATA[Stories by Communications Power Zone on Medium]]></description>
        <link>https://medium.com/@communications_21063?source=rss-b8fb9cc12b8a------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/0*Q-So5ZdgwdsNps_j.</url>
            <title>Stories by Communications Power Zone on Medium</title>
            <link>https://medium.com/@communications_21063?source=rss-b8fb9cc12b8a------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Thu, 19 Nov 2026 20:36:04 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@communications_21063/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Selling Centrifugal & Reciprocating Pumps & Engineering Industrial Fluid
Handling Systems]]></title>
            <link>https://medium.com/@communications_21063/selling-centrifugal-reciprocating-pumps-engineering-industrial-fluid-handling-systems-598f32c1fb5?source=rss-b8fb9cc12b8a------2</link>
            <guid isPermaLink="false">https://medium.com/p/598f32c1fb5</guid>
            <category><![CDATA[oil-and-gas-industry]]></category>
            <category><![CDATA[oil-and-gas]]></category>
            <category><![CDATA[centrifugal-pump]]></category>
            <category><![CDATA[energy]]></category>
            <category><![CDATA[reciprocating-pump]]></category>
            <dc:creator><![CDATA[Communications Power Zone]]></dc:creator>
            <pubDate>Tue, 04 Jun 2019 17:53:54 GMT</pubDate>
            <atom:updated>2019-06-04T17:53:54.102Z</atom:updated>
            <content:encoded><![CDATA[<iframe src="https://cdn.embedly.com/widgets/media.html?src=https%3A%2F%2Fwww.youtube.com%2Fembed%2Fg4Lnu-GV3Sw%3Ffeature%3Doembed&amp;url=http%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3Dg4Lnu-GV3Sw&amp;image=https%3A%2F%2Fi.ytimg.com%2Fvi%2Fg4Lnu-GV3Sw%2Fhqdefault.jpg&amp;key=a19fcc184b9711e1b4764040d3dc5c07&amp;type=text%2Fhtml&amp;schema=youtube" width="854" height="480" frameborder="0" scrolling="no"><a href="https://medium.com/media/90eaa73a5cd7760148c930ac6bcf5ea9/href">https://medium.com/media/90eaa73a5cd7760148c930ac6bcf5ea9/href</a></iframe><p>Our President Don Toews sat down with <a href="https://www.crownsmen.com/podcast/"><strong><em>The Crownsmen Podcast</em></strong></a> to examine the ins and outs of supplying the oil and gas and mining sectors with industrial pumps. At Power Zones we deal with some of the most complex systems to manage fluid handling operations during the oil and gas extraction process including oilfield <a href="https://www.powerzone.com/industries/water"><strong><em>water management</em></strong></a> and drilling waste management. In this interview you not only hear our story but how</p><p>Don came to found the company. Learn how Power Zone evolved from only offering used pumps to offering industrial pump engineering services in not only the USA but around the world.</p><p>Over the years we have offered fluid handling solutions for everything from <a href="https://www.powerzone.com/industries/oilandgas"><strong><em>oil and gas</em></strong></a> fields to <a href="https://www.powerzone.com/industries/mining"><strong><em>mining operations</em></strong></a>, and even <a href="https://www.powerzone.com/industries/agriculture"><strong><em>agriculture</em></strong></a>. From this interview you will have a better understanding of our engineering process for <a href="https://inventory.powerzone.com/search/centrifugal-pumps"><strong><em>centrifugal pump packages</em></strong></a>, both <a href="https://inventory.powerzone.com/search/single-stage-centrifugal-pumps"><strong><em>single-stage centrifugal pumps</em></strong></a> and <a href="https://inventory.powerzone.com/search/multi-stage-centrifugal-pumps"><strong><em>multi-stage centrifugal pumps</em></strong></a> as well as <a href="https://inventory.powerzone.com/search/reciprocating-positive-displacement-pumps"><strong><em>reciprocating pumps</em></strong></a>, including single acting <a href="https://inventory.powerzone.com/search/triplex-pumps"><strong><em>triplex pumps</em></strong></a> and <a href="https://inventory.powerzone.com/search/reciprocating-double-acting-pumps"><strong><em>double<br>acting reciprocating pumps</em></strong></a>.</p><p>We hope you enjoy and look forward to your feedback on the show!</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=598f32c1fb5" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Serbia Steel Mill Pump Rebuild]]></title>
            <link>https://medium.com/@communications_21063/serbia-steel-mill-pump-rebuild-508586fdc73b?source=rss-b8fb9cc12b8a------2</link>
            <guid isPermaLink="false">https://medium.com/p/508586fdc73b</guid>
            <category><![CDATA[repair]]></category>
            <category><![CDATA[steel-mill-pump]]></category>
            <category><![CDATA[industrial-pumps]]></category>
            <category><![CDATA[oil-and-gas]]></category>
            <category><![CDATA[oil-and-gas-industry]]></category>
            <dc:creator><![CDATA[Communications Power Zone]]></dc:creator>
            <pubDate>Tue, 18 Sep 2018 17:43:47 GMT</pubDate>
            <atom:updated>2018-09-18T17:43:47.235Z</atom:updated>
            <content:encoded><![CDATA[<p>Power Zone overhauled a 4000 horsepower 7 stage descaling pump for a steel mill in eastern Europe. The mill had three 50% pumps and was in its 5th month awaiting repair in the shop of a major pump OEM. When the second pump suffered major vibrations, they were forced to operate at a reduced output and needed the second pump repaired quickly. Power Zone accepted one of its most challenging equipment rebuilds yet, returned the pump to the customer in just 10 weeks.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/500/0*gNuxP9QE7sdmBadl.JPG" /><figcaption>Damaged Cut-Water</figcaption></figure><p>The pump was a classic basket case. The first impeller was broken and the wear rings had been stripped off. Pieces of the first and second stage wear rings were found lodged in the next 4 impellers. The interstage piece between the first and second stage impeller was similarly destroyed, taking its saddle fit in the casing with it. The pieces lodged in the first impeller caused severe cavitation, which removed about an inch and a half of material from the cutwaters. An 8 square inch piece of the shroud on the 5th impeller had broken out. The shaft was bent, and the bearing housings were warped.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/500/0*rYrYzrkATVYoZfi2.JPG" /><figcaption>Damaged impeller and missing wear ring</figcaption></figure><p>We had new impellers cast for the 1st and 5th impellers, made a new shaft, replaced all the impeller rings, re-machined the case rings, replaced the shaft mounted lube oil pump, made a new interstage piece, new throttle, and center bushings, and repaired the throttle and center sleeves. Add new packing sleeves, weld repair the cutwaters and casing saddle fits, clip-and-bore the casing and bearing housings, balance the rotor, and the pump was re-assembled.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/338/0*ZHshw9MtOhiHnc41.JPG" /><figcaption>Broken impeller as a result of catastrophic pump failure</figcaption></figure><p>And then we put it on our test stand and ran it, developing the full performance curve with power draw, efficiency, and NPSH curves included. 10 weeks after receiving it, we crated the pump up and returned it to the (very happy) client. Then we assisted in the on-site re-commissioning of the pump a few weeks later. The first pump was still at the OEM repair shop 7 months after our pump was placed into service.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/500/0*wDhmgmM0WSTrx43l.JPG" /><figcaption>One of several re-cast impellers for the rebuilt pump</figcaption></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=508586fdc73b" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[New Pump Smell]]></title>
            <link>https://medium.com/@communications_21063/new-pump-smell-b8ffa2ab61e9?source=rss-b8fb9cc12b8a------2</link>
            <guid isPermaLink="false">https://medium.com/p/b8ffa2ab61e9</guid>
            <category><![CDATA[oil-and-gas]]></category>
            <category><![CDATA[oil-and-gas-industry]]></category>
            <category><![CDATA[energy]]></category>
            <category><![CDATA[industrial-pumps]]></category>
            <dc:creator><![CDATA[Communications Power Zone]]></dc:creator>
            <pubDate>Mon, 17 Sep 2018 18:04:37 GMT</pubDate>
            <atom:updated>2018-09-17T18:04:37.650Z</atom:updated>
            <content:encoded><![CDATA[<p>I buy used cars. My frugal self just can’t part with the extra money it takes to get from “serves my needs well” to “two digits on the odometer”. I can research the history, the year, and model of the car to see how much maintenance they take compared to others. And, I can afford more car.</p><p>Can the same logic be used for pumps and other rotating equipment? Well, depends on what you are after. For pumps, in many cases, the answer is a very strong yes. The first few reasons are fairly obvious:</p><ul><li>Price should be lower than a new pump</li><li>Lead time should be substantially shorter. Many large pumps have lead times of 40–50 weeks. Rebuilding a pump can have a near-new unit in your hands in 10 weeks. Lost time equals lost an opportunity and lost profits.</li><li>There may be exact replacement pumps available in the used equipment market, meaning you can avoid messing with changing your piping, bases, foundations, etc. to fit a different model of pump. And then you can have your first pump rebuilt and ready as a spare.</li></ul><p>Remember that you can also afford more pump. In the recent past, inexpensive multistage pumps have been produced that have seriously challenged any notion of long term reliability. If customers can be distracted by the nice curves, low price, and relatively fast delivery, they can overlook the pump’s expected lifespan. There are some customers who are fine with that. Replacements after 5 years could be an acceptable option for some.</p><p>That rubs me wrong. I buy the most durable car that fits my needs and I expect it to last more than 60,000 miles. Several times over. Same with pumps. By investing a similar amount of capital (probably just a bit more) into a heavy multistage horizontal split case pump rather than a quick and cheap pump, the future returns can far outweigh the incremental cost increase. I’d rather have a used Camry than a new Fiat.1</p><p>But aren’t new pumps better? Maybe, but there is a huge population of big, heavy pumps that have been running since the 1940s. That is proven reliability. And not much has changed in the intervening years. Rebuilding a surplus pump to restore the clearances, check for cracks, and reassemble with precision can deliver a high-quality product with lots of life left in them.</p><p>Remember that surplus and previously owned don’t necessarily mean used. The recent oil bust resulted in lots of projects being canceled after the pumps were delivered to the end user. The end user sells off those now homeless pumps and they usually wind up in the yard of a surplus pump dealer, unused and some still in the original packing crates. If your application matches, you can score brand new pump equipment at a fraction of its original price, with no lead time.</p><p>Another often overlooked benefit of considering used and surplus pumps is the companies who deal with them. Many of the used pump dealers have years of experience with all sorts of different brands and models and can give opinions about available options. Those companies are generally smaller and can be significantly easier to deal with than a large OEM. Ask for sample rebuild reports to check the standards of your potential supplier. Several of the surplus companies offer services beyond basic pump reconditioning: complete packages with drivers, baseplates, seal systems, lube systems, enclosures, instrumentation, and controls can be added to the pump to provide a complete one-stop solution. Customizing systems like this might be difficult or even impossible with a major OEM.</p><p>To calm nerves, request testing. Have a complete performance test run on your pump to prove it out before taking delivery. Nobody likes losing sleep worrying if the equipment is going to work properly once installed. Buying a motor or engine? Same standards. Ask for dyno results, Meggerr tests, surge tests, or whatever else you need to be sure you are satisfied with the equipment.</p><p>So, is there any equipment that should not be purchased surplus, used, or rebuilt? Here are things to consider:</p><ul><li>Well servicing pumps are notoriously abused. They are used for a range of high-pressure jobs and can wear out faster than other pumps. Have the dealer or your representative check it over VERY closely before investing in used well service pumps.</li><li>Slurry pumps are designed for services that wear them out. Again, be sure the pump is relatively new as many of the major parts can have service lives of a few years, depending on how they are applied.</li><li>Electric motors. Unlike the slight changes in pumps over the past years, motors have evolved. The efficiencies are up and the new motors are almost all compatible with VFDs. The hazardous area classifications may rule out many older motors, and the shaft seals standard on IEEE 841 motors are a great addition. Be sure the surplus motors are not too old, and consider what testing you need to avoid heartburn.</li><li>Diesel engines — Like electric motors, the regulations for diesel engines are constantly evolving. The latest move to Tier 4 units may have some a bit taken aback at the new prices. Before purchasing an older engine, become familiar with the regulations. Rental units may be regulated differently than permanent installations.</li></ul><p>Based on Consumer Report reliability ratings</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=b8ffa2ab61e9" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Duplex Pump]]></title>
            <link>https://medium.com/@communications_21063/duplex-pump-6b912f0df6e7?source=rss-b8fb9cc12b8a------2</link>
            <guid isPermaLink="false">https://medium.com/p/6b912f0df6e7</guid>
            <category><![CDATA[oil-and-gas-industry]]></category>
            <category><![CDATA[energy]]></category>
            <category><![CDATA[industrial-pumps]]></category>
            <category><![CDATA[oil-and-gas]]></category>
            <category><![CDATA[duplex-pump]]></category>
            <dc:creator><![CDATA[Communications Power Zone]]></dc:creator>
            <pubDate>Fri, 14 Sep 2018 17:54:54 GMT</pubDate>
            <atom:updated>2018-09-14T17:54:54.393Z</atom:updated>
            <content:encoded><![CDATA[<h4>A designation of a <a href="https://www.powerzone.com/resources/glossary/reciprocating-pump">reciprocating pump</a> that uses two drive rods.</h4><p>Duplex pumps are common in both single and dual acting designs. Due to some of the benefits over simplex pumps, and simpler design than other <a href="https://www.powerzone.com/resources/glossary/reciprocating-pump"><em>reciprocating pumps</em></a>, they are often a preferred pump for many applications.</p><p>Essentially, a single action duplex pump is two simplex pumps running at 180 degrees from each other. As one plunger or piston is pumping fluid into the outlet port, the other is drawing in from the inlet. A dual action is similar in style but is only offset at 90 degrees. Theoretically, a dual action duplex operates using four single-acting plungers or pistons. Keeping the rotation at 180 degrees would create two overlapping sets of plungers or pistons. A 90-degree offset helps to stabilize the flow. See the flow characteristics below for more information.</p><h3>Duplex Pump Flow Characteristics</h3><p>Duplex pumps have a steadier flow than <a href="https://www.powerzone.com/resources/glossary/simplex"><em>simplex pumps</em></a>. However, their flow still has a large variation. In a single action duplex pump, the maximum flow velocity is 160% of the average. That is, every rotation of the crankshaft, the flow varies from 0% to 160% of the average flow rate. In a double acting duplex pump, the maximum flow velocity only varies between 111% and 79% of the average flow rate.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/796/0*mMHz_SlPSmmvqXp3.png" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/796/0*MGIpi6pj4XMroNAD.png" /></figure><p>Note that the dual action charts are made specifically for a plunger pump. In a dual action piston pump, pump chambers one and three would look similar to that shown above, but chambers two and four would have a slightly lower relative velocity. This is due to the fact that one side of the piston requires the drive rod, reducing the usable volume within these pump chambers.</p><h3>Duplex Pump Example Applications</h3><p>Duplex pumps are used in low flow applications across many industries. Several example applications may include:</p><ul><li>Crude Oil Transfer</li><li>Hydrocarbon Condensate Collection</li><li>Coke Oven Tar</li><li>Bauxite Slurry</li><li>Salt Water Disposal</li><li>Hot Oil</li><li>Cement</li><li>Aluminum Ore Slurry</li><li>Coal Slurry</li><li>Cryogenic Service</li><li>Steam</li><li>Ore Slurry</li><li>Drilling Mud</li></ul><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=6b912f0df6e7" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Single Action Pump]]></title>
            <link>https://medium.com/@communications_21063/single-action-pump-1ca4ebea0c7b?source=rss-b8fb9cc12b8a------2</link>
            <guid isPermaLink="false">https://medium.com/p/1ca4ebea0c7b</guid>
            <category><![CDATA[single-action-pump]]></category>
            <category><![CDATA[reciprocating-pump]]></category>
            <category><![CDATA[oil-and-gas-industry]]></category>
            <category><![CDATA[industrial-pumps]]></category>
            <category><![CDATA[oil-and-gas]]></category>
            <dc:creator><![CDATA[Communications Power Zone]]></dc:creator>
            <pubDate>Thu, 13 Sep 2018 16:21:58 GMT</pubDate>
            <atom:updated>2018-09-13T16:21:58.368Z</atom:updated>
            <content:encoded><![CDATA[<h4>A reciprocating pump design that produces a pressure differential across the pump in only one direction of drive rod motion.</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*0yt7016W9GupXscL.gif" /></figure><p>Single action pumps only use a single pump chamber per drive rod. They are only capable of producing pressure while the plunger or piston is moving into the pump chamber. Single action pumps are common in all sizes of reciprocating plunger and piston pumps.</p><h3>Single Action Pump Characteristics</h3><p>Single action pumps have design advantages and disadvantages over <a href="https://www.powerzone.com/resources/glossary/dual-acting"><em>dual acting</em></a> designs. A single action or double action pump should be selected based off of system requirements and design.</p><p>The flow of a single action pump will have more variation in the flow compared to a double action pump of the same size. Each drive rod is producing a pressure differential across the pump through half of the drive shaft’s rotation. The unsteady flow results in larger pressure waves. Attention to surrounding system design, or the addition of a <a href="https://www.powerzone.com/resources/glossary/pulsation-dampener"><em>pulsation dampener</em></a><em>,</em> may be more important for single action, and all reciprocating pumps. Especially in smaller sizes. For example, <a href="https://www.powerzone.com/resources/glossary/simplex"><em>simplex</em></a>, <a href="https://www.powerzone.com/resources/glossary/duplex"><em>duplex</em></a>, and <a href="https://www.powerzone.com/resources/glossary/triplex"><em>triplex</em></a><em> pump sizes</em>.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=1ca4ebea0c7b" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Septuplex Pump]]></title>
            <link>https://medium.com/@communications_21063/septuplex-pump-ad4c71d09f3d?source=rss-b8fb9cc12b8a------2</link>
            <guid isPermaLink="false">https://medium.com/p/ad4c71d09f3d</guid>
            <category><![CDATA[triplex-pump]]></category>
            <category><![CDATA[industrial-pumps]]></category>
            <category><![CDATA[energy]]></category>
            <category><![CDATA[quintuplex-pump]]></category>
            <category><![CDATA[septuplex-pump]]></category>
            <dc:creator><![CDATA[Communications Power Zone]]></dc:creator>
            <pubDate>Wed, 12 Sep 2018 17:27:11 GMT</pubDate>
            <atom:updated>2018-09-12T17:27:11.022Z</atom:updated>
            <content:encoded><![CDATA[<h4>A reciprocating pump which utilizes seven drive rods to transfer linear motion to the pump’s pistons or plungers.</h4><p>Septuplex pumps are not as common as other pumps using fewer drive rods. In many applications, a single <a href="https://www.powerzone.com/resources/glossary/quintuplex"><em>quintuplex</em></a>, or two <a href="https://www.powerzone.com/resources/glossary/triplex"><em>triplex</em></a> in parallel are used to meet flow requirements. Septuplex pumps are used in applications where flow variation and pressure pulsations are needed to be kept to a minimum.</p><h3>Septuplex Pump Flow Characteristics</h3><p>Septuplex pumps have roughly half of the flow variation of quintuplex pumps. The flow in a septuplex pump fluctuates between 97% and 101% (4% variation) from the average flow rate. There is and additional variation after the pump reaches its maximum flow rate at 101%. The flow will drop to 99% before returning back to its maximum, and then to its minimum. The maximum to minimum flow rate variation takes place seven times per crankshaft revolution.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/770/0*JPQzcpzztKxJGRMz.png" /></figure><h3>Septuplex Pump Example Applications</h3><p>Septuplex pumps are routinely used for low to medium flow applications such as:</p><ul><li>Amine Circulation</li><li>Reverse Osmosis</li><li>Crude Oil Transfer</li><li>Hydraulic Fracturing</li><li>Descaling</li><li>Salt Water Injection</li><li>Hydrocarbon Condensate</li><li>Well Service</li><li>Water Jetting</li><li>CO2 Injection</li><li>Water Flooding</li></ul><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=ad4c71d09f3d" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Iveco C13 Diesel Engine Run Test — Testing Diesel Engines]]></title>
            <link>https://medium.com/@communications_21063/iveco-c13-diesel-engine-run-test-testing-diesel-engines-5ab2d71ae336?source=rss-b8fb9cc12b8a------2</link>
            <guid isPermaLink="false">https://medium.com/p/5ab2d71ae336</guid>
            <category><![CDATA[manufacturing]]></category>
            <category><![CDATA[diesel-engines]]></category>
            <category><![CDATA[oil-and]]></category>
            <category><![CDATA[caterpillar]]></category>
            <category><![CDATA[cummins]]></category>
            <dc:creator><![CDATA[Communications Power Zone]]></dc:creator>
            <pubDate>Tue, 11 Sep 2018 16:18:47 GMT</pubDate>
            <atom:updated>2018-09-11T16:18:47.592Z</atom:updated>
            <content:encoded><![CDATA[<iframe src="https://cdn.embedly.com/widgets/media.html?src=https%3A%2F%2Fwww.youtube.com%2Fembed%2FmpJ-U_Uvwzw%3Ffeature%3Doembed&amp;url=http%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3DmpJ-U_Uvwzw&amp;image=https%3A%2F%2Fi.ytimg.com%2Fvi%2FmpJ-U_Uvwzw%2Fhqdefault.jpg&amp;key=a19fcc184b9711e1b4764040d3dc5c07&amp;type=text%2Fhtml&amp;schema=youtube" width="854" height="480" frameborder="0" scrolling="no"><a href="https://medium.com/media/9fa0bf365c61db32fb87d538836e2ff8/href">https://medium.com/media/9fa0bf365c61db32fb87d538836e2ff8/href</a></iframe><p>Power Zone offers a wide range of new, used and reconditioned engines including Diesel Engines, Natural Gas Engines, Gas Engines, Propane Engines, and Hit &amp; Miss Engines, sometimes referred to as Putt &amp; Putt Engines or Pumpjack Engines. We provide these engines from many different manufacturers including Caterpillar, MTU, Detroit, Cummins, John Deere Ajax and Arrow. We have engines for most applications including Portable Power Units, Heavy Machinery, Fluid Pumping, Air Compression and Backup Power for the municipal, manufacturing, oil &amp; gas, mining and agriculture sectors.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=5ab2d71ae336" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Engine Powered Generators | Components and Types of Generators]]></title>
            <link>https://medium.com/@communications_21063/engine-powered-generators-components-and-types-of-generators-e9d55d608e90?source=rss-b8fb9cc12b8a------2</link>
            <guid isPermaLink="false">https://medium.com/p/e9d55d608e90</guid>
            <category><![CDATA[energy]]></category>
            <category><![CDATA[engine-generator]]></category>
            <category><![CDATA[heavy-equipment-companies]]></category>
            <category><![CDATA[industrial-equipment]]></category>
            <category><![CDATA[oil-and-gas-industry]]></category>
            <dc:creator><![CDATA[Communications Power Zone]]></dc:creator>
            <pubDate>Wed, 05 Sep 2018 16:26:18 GMT</pubDate>
            <atom:updated>2018-09-05T16:26:18.513Z</atom:updated>
            <content:encoded><![CDATA[<p><strong>Know About Generators — Engine driven Generators</strong></p><p>A <a href="http://inventory.powerzone.com/search/generators"><em>generator</em></a> is best described as a machine, which transforms mechanical energy into electrical energy through combustion of a fuel. Although most of the engine driven generators have been argued to be hazardous to the environment but they offer various advantages to the users in industries.</p><p>An engine generator set is more commonly known as <strong>“Genset”</strong>. They are generally rated in horsepower or a torque, watts or Kilowatts. The main components of an engine driven generator includes an engine, fuel supply mechanism, a constant engine speed regulator and a generator voltage regulator, cooling and exhaust systems, and lubrication system which have been described in detail in this article.</p><p>Generators usually use the following as fuel: gasoline, diesel, natural gas, propane, biodiesel, water, sewage gas or hydrogen. Generators of small size use gasoline (petrol) or diesel as a fuel, and the larger ones run on diesel, natural gas or propane. Some engines may also operate on diesel and gas simultaneously.</p><p><strong>Components of an engine driven generator:</strong></p><ul><li><strong>Engine:</strong> In an engine driven generator, the engine is the main component. It creates mechanical energy that gets converted into electricity. A generator engine’s design and size determine the maximum power output it can create by running on a specific fuel or another power source.</li><li><strong>Fuel Mechanism — Fuel tank, Fuel pipes, Fuel filter etc:</strong> The entire system contains a tank for storage of fuel and fuel pipes connecting the tank and the engine. The fuel pump moves the fuel through the fuel pipes to the engine and a fuel filter helps filter any debris from the fuel before delivery to the engine. This ensures maximum efficiency and increases the durability of the engine. The fuel injector injects the fuel directly into the combustion chamber of the engine.</li><li><strong>Alternator: </strong>The alternator consists of the stator and the rotor. A set of coils that conduct electricity is called a stator which is a stationary part, whereas a rotor moves to create a constantly rotating electromagnetic field around the stator.</li><li><strong>Voltage Regulator:</strong> A voltage regulator is primarily used to regulate the voltage produced, which is suitable for the application or purpose of a generator.</li><li><strong>Cooling and Exhaust System:</strong> the Cooling system is required in a generator to avoid overheating or regulate the temperature when in use. An exhaust is required to dispel harmful gases emitted during operation of a generator. Generators often use a fan, coolant or both to control the temperature of the generator at work.</li><li><strong>Lubricating System:</strong> Since generators comprise of many moving parts, they require regular oiling to ensure smooth functioning. The lubricating system in a generator helps in performing this function.</li></ul><p>All these components play a crucial role in smooth functioning of a generator. The working principle of a generator is simple. The mechanical energy needed to turn the generator comes from the combustion of fuel through the fuel system. The coiled wires used, spin inside a magnetic field which causes an electric current to flow in the wire. The voltage regulator helps to control the amount of electric current that is produced. The coolant and exhaust system functioning in a generator helps to regulate temperature and dispel gases respectively.</p><p><strong>Types of generator</strong></p><p>Generators are mainly of two types, <strong>Induction (Asynchronous) generator and Synchronous generator</strong>.</p><ul><li><strong>Induction Generators:</strong> An induction generator is also called as an asynchronous generator. It is a type of Alternating Current (AC) electrical generator, which principally works similar to the working of an induction motor to produce power. Induction generators are operated by mechanically turning their rotors faster than synchronous speed. They are generally very useful in applications such as mini hydro power plants, wind turbines, or in reducing high-pressure gas streams to lower pressure.</li><li><strong>Synchronous generator: </strong>In general, a synchronous generator is equipped with two parts, namely rotor and stator. The rotor part consists of field poles and stator part consists of armature conductors. The rotation of field poles induces an alternating voltage which results in electrical power generation.</li></ul><p>Commercial electrical energy is mainly sourced by synchronous generators. Most common uses of these generators are to convert the mechanical power output of steam turbines, gas turbines, reciprocating engines and hydro turbines into electrical power for the grid which is mainly used in power plants.</p><p>These generators are designed to operate in complex and rigid processes of marine and industrial applications. They are highly efficient, reliable and certified by the most demanding Marine certifying agencies like DNV, ABS, BV, Lloyds. Common applications of these generators include diesel and gas driven reciprocating engines, prime and standby power and propulsion power for marine vessels.</p><p>Construction of induction generators is less complicated in comparison to synchronous generators as they do not require brushes and slip ring arrangements. Brushes are required in synchronous generator to supply DC voltage to the rotor for excitation.</p><p><strong>Diesel Generator Sets</strong> are generators that use diesel to run. These are commonly used as backup units for emergency power supply. They are available in both single and three-phase. Diesel engines in these gensets are sturdy and reliable. On the other hand, <strong>Natural Gas Generators</strong>, which use natural gas, works in a manner similar to other generators, however, they are widely used and efficient means of generating power since it uses the most affordable and effective fuels among non-renewable resources for power generation.</p><p>But in comparison, diesel generators are far more efficient. Also from a safety point of view, it is more preferable, since diesel is used which is less flammable than other fuel sources. New models of diesel gensets are less noisy. However, they are more expensive and may be bulky. A natural gas generator will use more fuel than a diesel generator.</p><p>Now, with the advent of biodiesel generators, disadvantages of a natural gas generator or a diesel generator can be discounted and they may become more of buyer’s preference.</p><p>Engine driven generators are widely used in power generation, renewable energy, <a href="https://www.powerzone.com/industries/oilandgas"><em>oil &amp; gas</em></a>, data storage &amp; <a href="https://www.powerzone.com/industries/manufacturing"><em>manufacturing industry </em></a>and are mainly used for emergency power generation, backup power generation, wind power generation and hydroelectric power.</p><p>Top and well-known manufacturers of generators offer different designs and features, suitable for all types of applications. Few of them are <a href="http://inventory.powerzone.com/search/generators/Onan"><em>Onan</em></a>, <a href="http://inventory.powerzone.com/search/query/category/generators/makes/Marathon%2CMarathon%20Electric?ranges="><em>Marathon</em></a>, <a href="http://inventory.powerzone.com/search/generators/Kato"><em>Kato</em></a>, Baldor, MTU, and <a href="http://inventory.powerzone.com/search/generators/Caterpillar"><em>Caterpillar</em></a>.</p><p>When it comes to choosing a generator, one must consider the following main deciding factors such as understanding the main purpose the generator, its noise level, fuel tank capacity, price, kilowatt rating and efficiency, RPM and frequency, controls and related switchgear etc. They are available in different sizes and horsepower of engines.</p><p>We shall be happy to assist in choosing the right one for you.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=e9d55d608e90" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Double Action / Dual Action]]></title>
            <link>https://medium.com/@communications_21063/double-action-dual-action-c30636244f53?source=rss-b8fb9cc12b8a------2</link>
            <guid isPermaLink="false">https://medium.com/p/c30636244f53</guid>
            <category><![CDATA[oil-and-gas]]></category>
            <category><![CDATA[heavy-equipment-companies]]></category>
            <category><![CDATA[mining-industry]]></category>
            <category><![CDATA[oil-and-gas-industry]]></category>
            <category><![CDATA[mining]]></category>
            <dc:creator><![CDATA[Communications Power Zone]]></dc:creator>
            <pubDate>Thu, 30 Aug 2018 16:06:38 GMT</pubDate>
            <atom:updated>2018-08-30T16:06:38.324Z</atom:updated>
            <content:encoded><![CDATA[<h4>A reciprocating pump design which produces a pressure differential across the pump on both the in and out stroke of each drive rod.</h4><p>Dual action pumps use two separate pumping chambers per drive rod. On the forward stroke, it pushes fluid out of the first chamber, and draws fluid into the other. On the back stroke, it the draws water into the first chamber and pushes fluid out of the other.</p><h3>Dual Action Plunger Pump Concepts</h3><p>Dual action pumps use either a swab on a piston rod, a piston, or two plungers. When two separate plungers or pistons are used, both of them move in unison, in the same direction as the drive rod. Although different designs allow for different configurations, the basic concept is shown below.</p><h3>Dual Action Piston Pump Operation</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/750/0*lUTL1Hi5B7sPR5oO.gif" /></figure><p>In this instance, packing is used to seal the pumping chamber around the piston rod. Additional sealing is required around the piston to prevent fluid from flowing around the piston.</p><p>Note that a double action piston pump with the above configuration shares one of the pumping chambers with the drive rod. The shared volume reduces the output volume and pressure of this chamber. In many designs, it is considered negligible and factored into the pump’s overall maximum pressure and flow rating. In a double action plunger pump with the configuration shown below, both chambers are able to reach equal pressures and flow rates.</p><h3>Double Action Plunger Pump Operation</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/450/0*Ms0x0D7YgmTzCg2r.gif" /></figure><p>Since double acting pumps are designed to produce pressure on both a “push” and a “pull” stroke, wear is different than in single acting pumps. The forces variations seen within the power end increase per revolution of the crankshaft. Power ends of dual acting pumps are generally designed slightly larger than single acting pumps of the same horsepower rating. This larger size is able to withstand wear and increase the life expectancy of the pump.</p><p>Dual acting pumps are most commonly found as a <a href="https://www.powerzone.com/resources/glossary/duplex">duplex pump</a> design.They can also be found in other reciprocating pump sizes, but are generally less common.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=c30636244f53" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Simplex Pump]]></title>
            <link>https://medium.com/@communications_21063/simplex-pump-79ae7464b3f3?source=rss-b8fb9cc12b8a------2</link>
            <guid isPermaLink="false">https://medium.com/p/79ae7464b3f3</guid>
            <category><![CDATA[mining-industry]]></category>
            <category><![CDATA[oil-and-gas-industry]]></category>
            <category><![CDATA[mining]]></category>
            <category><![CDATA[oil-and-gas]]></category>
            <dc:creator><![CDATA[Communications Power Zone]]></dc:creator>
            <pubDate>Wed, 29 Aug 2018 17:04:38 GMT</pubDate>
            <atom:updated>2018-08-29T17:04:38.106Z</atom:updated>
            <content:encoded><![CDATA[<h4>A simplex is the designation of a reciprocating pump which utilizes a single drive rod design.</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/695/0*RaXgZwzU5XCwkq1G.gif" /></figure><p><strong>ABOVE: SINGLE ACTING SIMPLEX PLUNGER PUMP</strong></p><p>Simplex pumps use a single drive rod to pump the fluid. They are available in both single and dual acting designs.</p><p>The number of pump chambers is not the best way to determine if a pump is a simplex design. The pump may have a single pumping chamber in a single acting pump, and two chambers in a dual acting pump. However, both are a considered a simplex pump because they only use a single drive rod.</p><h3>Simplex Pump Properties</h3><p>Simplex pumps are a simpler design than other reciprocating pumps which use more drive rods (such as <a href="https://www.powerzone.com/resources/glossary/triplex">triplex</a>, or <a href="https://www.powerzone.com/resources/glossary/quintuplex">quintuplex</a>). This simple design makes them easier to use, repair, and maintain. Their cost also tends to be lower due to a lower number of moving parts. Despite these benefits, simplex pumps have flow variations that require additional consideration when designing a pump system.</p><p>The image below references a single action simplex piston pump. Notice that fluid is only moving through the inlet of the pump when the piston is drawing back. Similarly, fluid is only moving through the outlet when the piston is pushing into the pumping chamber. As a result, the pump is only providing flow 50% of the time. The fluid in either the inlet or outlet is stagnant for 50% of the time.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1000/0*oe7peS5dj147YmUj.gif" /></figure><p>This change in flow creates <a href="https://www.powerzone.com/resources/glossary/pulsation-dampener"><em>pressure pulsations</em></a>, and acceleration head. Each time the flow changes from stagnant to flowing, or flowing to stagnant, pressure differentials are created through the pump and the surrounding piping. Depending on the amplitude of these pulsations, damage to the pump and surrounding system may be possible.</p><p>These pulsations can be relieved by providing a vent to atmospheric pressure, or through a pulsation dampener. It is important to ensure correct design of the system to prevent potential problems created by the changing flow.</p><p>The uneven flow characteristics for simplex reciprocating pumps can be seen below. Notice that the velocity of the flow reaches up to 320% of the average flow velocity for a single action, and up to 160.2% for a dual action. For example, if pumping a fluid at a flow rate of 10 GPM in a single action simplex pump, the flow is fluctuating between 0 and 32 GPM with each rotation of the crankshaft.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/796/0*134ZLYpW0ljJ1sAS.png" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/796/0*UTXhs2MpxpQ5svRJ.png" /></figure><h3>Example Uses for Simplex Pumps</h3><p>Despite uneven flow characteristics, simplex pumps can be good candidates for:</p><ul><li>Pump Jacks</li><li>Steam Pump</li><li>Watter Jetting</li><li>Water Wells</li><li>Metering Pump</li><li>Glycol Circulation</li><li>Injection Molding</li><li>Hot Oil</li><li>Hand Pumps</li></ul><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=79ae7464b3f3" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>