<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by ENGINEERS IN MAKING on Medium]]></title>
        <description><![CDATA[Stories by ENGINEERS IN MAKING on Medium]]></description>
        <link>https://medium.com/@engineeringandindustry?source=rss-5c9e39dc8b83------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/1*fjySHV7cMgevM6EqTNHaEw.jpeg</url>
            <title>Stories by ENGINEERS IN MAKING on Medium</title>
            <link>https://medium.com/@engineeringandindustry?source=rss-5c9e39dc8b83------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Sun, 22 Nov 2026 23:01:33 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@engineeringandindustry/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Vapour Compresion Refrigeration V/S Vapour Absorption Refrigeration Systems]]></title>
            <link>https://engineeringandindustry.medium.com/vapour-compresion-rrefrigeration-v-s-vapour-absorption-refrigeration-systems-dfcf0d12dd2f?source=rss-5c9e39dc8b83------2</link>
            <guid isPermaLink="false">https://medium.com/p/dfcf0d12dd2f</guid>
            <category><![CDATA[vcr]]></category>
            <category><![CDATA[refrigeration]]></category>
            <category><![CDATA[absorption]]></category>
            <category><![CDATA[compression]]></category>
            <category><![CDATA[var]]></category>
            <dc:creator><![CDATA[ENGINEERS IN MAKING]]></dc:creator>
            <pubDate>Mon, 10 May 2021 04:08:48 GMT</pubDate>
            <atom:updated>2021-05-10T06:07:46.401Z</atom:updated>
            <cc:license>https://creativecommons.org/publicdomain/mark/1.0/</cc:license>
            <content:encoded><![CDATA[<p><strong>VAPOUR COMPRESSION REFRIGERATION:</strong></p><p>VCR stands for Vapour Compression Refrigeration Cycle. It is the most widely used refrigeration system in which the working fluid is a vapor which readily evaporates and condenses (changes alternatively between the vapor and liquid phase) without leaving the refrigerating plant.</p><p>During evaporation, it absorbs heat from the cold body and this heat is used as its latent heat for converting it from liquid to vapour; whereas in condensing or cooling, it rejects heat to external bodies, thus, returning back to liquid form.</p><p><strong>Components of Vapour Compression Refrigeration System:</strong></p><p>1. Compressor:</p><p>The vapour at low pressure and low temperature enters the compressor from the evaporator where it is compressed to high pressure and high temperature. This high pressure and temperature vapour refrigerant is discharged into the condenser through the discharge valve.</p><p>2. Condenser:</p><p>The condenser or cooler consists of coils of pipe in which the high pressure and temperature vapour refrigerant are cooled and condensed. The refrigerant while passing through the condenser gives up its latent heat to the surroundings which is normally air or water.</p><p>3. Receiver:</p><p>The condensed liquid refrigerant from the condenser is stored in a vessel known as a receiver from where it is supplied to the evaporator through the expansion valve.</p><p>4. Expansion Valve:</p><p>It is also called a throttle valve. Its function is to allow the liquid refrigerant under high pressure and temperature to pass through it where it reduces its temperature and pressure.</p><p>5. Evaporator:</p><p>It also consists of coils of pipe in which liquid-vapour refrigerant at low pressure and temperature is evaporated and converted into vapour refrigerant at low pressure and temperature.</p><figure><img alt="Fig 1: Schematic diagram of Vapour Compression Refrigeration System" src="https://cdn-images-1.medium.com/max/810/1*Ms9UYhoNY3YfT5V4B6YeJQ.png" /><figcaption>Fig 1: Schematic diagram of Vapour Compression Refrigeration System</figcaption></figure><p><strong>Working of Vapor Compression Refrigeration System:</strong></p><p>The working of Vapor Compression Refrigeration System can be completed under 4 processes and are as follows.</p><p>Stage 1: Compression</p><p>The refrigerant (for example R-717 or R-22) enters the compressor at low temperature and low pressure. It is in a gaseous state. Here, compression takes place to raise the temperature and refrigerant pressure. The refrigerant leaves the compressor and enters the condenser. Since this process requires work, an electric motor may be used. Compressors themselves can be scroll, screw, centrifugal or reciprocating types.</p><p>Stage 2: Condensation</p><p>The condenser is essentially a heat exchanger. Heat is transferred from the refrigerant to the water which is flowing outside the condenser. This water goes to a cooling tower for cooling or is air-cooled. As the refrigerant flows through the condenser, it is in a constant pressure. To maintain this pressure, there are several pressure-controlling devices.</p><p>Stage 3: Throttling and Expansion</p><p>When the refrigerant enters the throttling valve, it expands and releases pressure. Consequently, the temperature drops at this stage. Because of these changes, the refrigerant leaves the throttle valve as a liquid vapor mixture, typically in proportions of around 75 % and 25 % respectively.</p><p>Throttling valves play two crucial roles in the vapor compression cycle:</p><ol><li>They maintain a pressure differential between low and high-pressure sides.</li><li>They control the amount of liquid refrigerant entering the evaporator.</li></ol><p>Stage 4: Evaporation</p><p>At this stage of the Vapor Compression Refrigeration Cycle, the refrigerant is at a lower temperature than its surroundings. Therefore, it evaporates and absorbs latent heat of vaporization. Heat extraction from the refrigerant happens at low pressure and temperature. Compressor suction effect helps maintain the low pressure.</p><p><strong>Advantages of VCR:</strong></p><p>The Advantages of Vapor Compression Refrigeration system are as follows.</p><p>1. The temperature at the evaporator section can be controlled by employing regulation of the expansion valve.</p><p>2. It exhibits a high Coefficient of Performance.</p><p>3. The initial cost is lower as compared to VAR because of a lesser number of components.</p><p>4. It produces a cooling effect quickly as compared to VAR cycle.</p><p><strong>Disadvantages of VCR:</strong></p><p>The disadvantages of Vapor Compression Refrigeration system are as follows.</p><p>1. Refrigerants can leak from the pipes/hose.</p><p>2. Refrigerants are not cheap, nor readily available.</p><p>3. Refrigerants can adversely affect the atmosphere.</p><p>4. The running cost of the system is high because vapour compression requires more power.</p><p>5. Load variation affects the working efficiency of VCR.</p><p><strong>Vapour Compression Refrigeration System Applications:</strong></p><p>The applications of Vapor Compression Refrigeration system are as follows.</p><p>1. It is used in domestic refrigeration for keeping the food.</p><p>2. It is helpful in food processing and cold storage.</p><p>3. It is useful in Industrial refrigeration for chemical processing, heating and cooling.</p><p>4. It is useful in Cryogenic refrigeration, Medical refrigeration, Transport refrigeration and Electronic cooling.</p><p><strong>VAPOUR ABSORPTION REFRIGERATION:</strong></p><p>The Vapor Absorption Refrigeration system comprises all the processes in the vapor compression refrigeration system like compression, condensation, expansion and evaporation. In the vapor absorption system the refrigerant used is ammonia with water as the absorber, or, water if used as a refrigerant with lithium bromide as the absorber. This cycle does not have a compressor. Instead, an absorber, a generator, a pump and a pressure reducing valve are used in order to replace the compressor of the VCR. The refrigerant produces a cooling effect at the evaporator and releases the heat to the atmosphere via the condenser.</p><figure><img alt="Fig 2: Simple Vapour Absorption Refrigeration System" src="https://cdn-images-1.medium.com/max/420/1*Efv796dI-bVMZU61FoqFgg.png" /><figcaption>Fig 2: Simple Vapour Absorption Refrigeration System</figcaption></figure><p><strong>Components and Working of Vapour Absorption Refrigeration System:</strong></p><p>Refer to the above schematic diagram to understand the components and working of VAR.</p><p>1. Absorber — The absorber is used to absorb the refrigerant. The absorber should have a higher affinity for the refrigerant vapours at low temperature, and lower affinity for refrigerant at higher temperatures. For NH3-H2O pairs of refrigerant-absorber, a strong aqua ammonia (NH3-H20) solution is formed which is further fed to the generator through a pump. The formation of this solution releases heat which increases the solution’s temperature and hence, a cooling jacket for the absorber is required to maintain a low temperature for efficient absorption of the refrigerant.</p><p>2. Pump — The pump increases the pressure of the strong solution of ammonia and water to condenser pressure and pumps it from the absorber to the generator.</p><p>3. Generator — The generator receives the high pressure solution of refrigerant. This solution is heated in the generator using a low-grade energy source, such as heat energy. This heat energy could be obtained from a large heat reservoir (such as a furnace), or solar energy may be used. This increase in temperature lowers the absorber’s affinity to the refrigerant. Since the boiling point of NH3 is lower than that of water, high temperature- high pressure refrigerant vapours are released from the generator into the further cycle.</p><p>4. Pressure Reducing Valve — The weak aqua ammonia solution remaining in the generator after refrigerant vapours are released is fed back to the absorber via a Pressure Reducing valve which lowers its temperature and pressure.</p><p>5. Condenser- Condenser is used to convert the ammonia vapour back into liquid phase. This condenser can be either water-cooled or air-cooled. The liquid refrigerant has a high temperature and pressure.</p><p>6. Expansion Valve- It reduces the temperature and pressure of the liquid refrigerant obtained at the condenser.</p><p><strong>Practical Vapour Absorption Refrigeration:</strong></p><p>The replacement of the compressor by the simple arrangement as shown in the above figure is not very economical in practice. In order to make improvements certain additional auxiliary items are provided in the system. They include an analyzer, a rectifier, and two heat exchangers. The practical absorption cycle was developed after incorporating these all auxil­iary items.</p><figure><img alt="Fig 3: Practical Vapour Absorption refrigeration" src="https://cdn-images-1.medium.com/max/388/1*5qwGsUqtmhsOgvlqcyM7iQ.png" /><figcaption>Fig 3: Practical Vapour Absorption refrigeration</figcaption></figure><p>Analyzer: The ammonia vapours leaving the generator may contain some moisture, and therefore it should be made free from any trace of water vapour before passing on to the condenser and then to the expansion valve, otherwise the water vapour is likely to get freeze at some small valve passage and may choke the flow. The analyzer is an open type of cooler and is mounted on the top of the generator. Both the strong aqua-ammonia solution from the absorber and the condensate removed in the rectifier are introduced from the top of the generator and they flow downwards.</p><p>Rectifier: It is a closed type of cooler and is actually a miniature condenser where any traces of water vapour left in the ammonia vapour are removed by condensation. The condensed water is drained back to the generator through the analyzer.</p><p>Heat Exchangers: Two heat exchangers are provided to internally exchange heat from the higher tempera­ture fluid to the lower temperature fluid so that one is cooled and the other is heated. One heat exchanger is provided between liquid receiver and evaporator so that the liquid is sub-cooled and vapour is heated up. Another heat exchanger is located between generator and absorber so that the strong aqua-ammonia solution is heated up before going on to the generator and weak aqua-ammonia solution is cooled before entering the absorber.</p><p><strong>Single-Effect and Double-Effect VAR:</strong></p><p>In vapour absorption refrigeration system, the temperature of the heat source plays an important role. The heat given by the source may be used in one single stage or in more than one stage. Accordingly the system is called a single stage or single effect cycle of operation and if the heat is supplied in two stages then the system is called two stage or double effect cycle of operation.</p><p>It is found that when the temperature of the heat source is up to 105°C, the heat is utilized in a single stage and the cycle is a single effect cycle. When the temperature of a heat source is greater than 105°C, then generally the heat is utilized in two stages and the system becomes a double-effect cycle.</p><p>1. Single Effect VAR:</p><p>A simple and practical absorption system using ammonia as refrigerant and water as absorbent described previously is an example of a single-effect cycle system for vapour absorption refrigeration system.</p><p>2. Double Effect VAR:</p><p>The schematic sketch of the double-effect VAR Cycle with Water and Lithium-Bromide (Li-Br) as the refrigerant- absorber pair is shown below. Here, water is the refrigerant and Lithium-Bromide is the absorber. Vapors of refrigerants are generated in two stages as shown. For this purpose two heat exchangers are used.</p><figure><img alt="Fig 4: Double Effect Water &amp; Li-Br VAR cycle" src="https://cdn-images-1.medium.com/max/419/1*H3Lx0K7EdGUlXjAWUMje_A.png" /><figcaption>Fig 4: Double Effect Water &amp; Li-Br VAR cycle</figcaption></figure><p>A double effect system consists of two heat exchangers and two generators (high and low pressure). It is an absorption system with improved efficiency which employs a second generator which uses water vapour from the first generator to provide its heat supply.</p><p>The evaporator pressure is maintained very low, so refrigerant water evaporates quickly after absorbing the heat, and the water vapors are absorbed by a strong Li-Br solution in the absorber. This absorption makes the Li-Br solution weak.</p><p>This weak solution is then pumped to the first, high pressure generator where it is heated up. While going towards the generator, it passes through a heat exchanger where it absorbs heat from the strong, high temperature Li-Br solution coming from the high pressure generator.</p><p>Heating up of the weak Li-Br solution in the first generator leads to evaporation of some portion of water, thereby making the Li-Br solution strong. This strong Li-Br solution is now throttled to lower pressure to that of the second generator causing the solution to develop flash vapour which is liquefied at the condenser and the remaining strong Li-Br solution is passed back to absorber via another heat exchanger. The strong Li-Br solution in the second, lower pressure generator is also heated, thereby releasing more water vapor to the condenser.</p><p>The condensate from the condenser is sent to the evaporator thus completing the cycle.</p><p><strong>Advantages of VAR:</strong></p><ol><li>The whole system will operate over a huge temperature range.</li><li>Running cost of the cycle is low because liquid compression requires lesser power.</li><li>Load variation does not affect performance of the cycle.</li><li>No need of supplying any high-grade energy source for the running of the refrigerator.</li><li>Refrigerants used are cheap and readily available.</li></ol><p><strong>Disadvantages of VAR:</strong></p><ol><li>Efficiency of the absorption system is low as compared to VCR.</li><li>Time required to produce a cooling effect is more than time taken by the VCR system.</li><li>If kerosene/oil/gas flame is used for heating in the generator, it will emit a bad smell.</li><li>Initial cost of the Vapor Absorption Refrigeration System will be higher than Vapour Compression Refrigeration System because of additional components required.</li><li>Lithium bromide which will be used in VARS can be corrosive in nature which may affect the overall life of the system.</li></ol><p><strong>Applications of VAR:</strong></p><p>1. Used for Air Conditioning in Recreational Vehicles, campers and caravans.</p><p>2. Used for waste heat recovery industries where a large amount of heat is generated.</p><p>3. Used in Absorption chillers for Conditioning.</p><p>4. Used in Domestic Electrolux Refrigerators.</p><p><strong>COMPARISON BETWEEN VAPOUR COMPRESSION &amp; VAPOUR ABSORPTION REFRIGERATION SYSTEMS:</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/675/1*R4OsPmPSY9a5SmpvH2ZH8w.png" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/675/1*I3IIKerItBXOTeZsnJUI3g.png" /></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=dfcf0d12dd2f" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[READING A PRODUCTION DRAWING]]></title>
            <link>https://engineeringandindustry.medium.com/reading-a-production-drawing-1d0fc94f45eb?source=rss-5c9e39dc8b83------2</link>
            <guid isPermaLink="false">https://medium.com/p/1d0fc94f45eb</guid>
            <category><![CDATA[gd-and-t]]></category>
            <category><![CDATA[production-drawing]]></category>
            <category><![CDATA[tolerance]]></category>
            <category><![CDATA[production-design]]></category>
            <category><![CDATA[engineering-design]]></category>
            <dc:creator><![CDATA[ENGINEERS IN MAKING]]></dc:creator>
            <pubDate>Sun, 27 Dec 2020 07:51:22 GMT</pubDate>
            <atom:updated>2021-05-10T04:16:45.817Z</atom:updated>
            <content:encoded><![CDATA[<h3>Reading a Production Drawing</h3><h3>Engineering Drawing vs. Production Drawing</h3><p>Engineering Drawing is what most of us have learnt during the preliminary years of engineering — Isometric drawings to orthographic projection and vice versa. A small example of such practice can be:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/400/0*MzfQ_s31Pl1NhiG5.jpg" /></figure><p>But these drawings are incomplete not very useful during the actual manufacturing of the desired part. During production, a lot of additional information needs to be given to the manufacturer.</p><p>For example:</p><p>i. the allowable amount of deviation from actual dimensions or geometry,</p><p>ii. The standard dimensions and number of holes (if any),</p><p>iii. Information on threading- internal or external, pitch, etc.,</p><p>iv. Information on surface finish.</p><p>For this purpose, GD&amp;T is used on engineering drawings or mechanical drawings to convert it into a production drawing.</p><h3>What is GD&amp;T?</h3><p>GD&amp;T stands for <em>Geometric Dimensioning and Tolerancing</em> — a system to define tolerances. It is a symbolic language used on engineering drawings and computer generated 3D models to define the allowable deviation of the feature’s geometry from its nominal dimensions.</p><p>It is us engineers’ very own code language! Although knowing GD&amp;T is a must for Design Engineers, it is must that each and every engineer should know GD&amp;T to properly read and decode a production drawing.</p><h3>Let’s understand production drawings..</h3><p>Production drawings are complete a sets of drawings that have detailed description of the manufacturing and assembly of designed products. The main purpose of production drawings is to define the size, shape, location and production of the component. Machine operators, production line workers and supervisors all use production drawings.</p><p>Design engineers use orthographic as the basis for both the component and assembly drawings. Production drawings contain graphic information prepared by the design team for use by the production team. Orthographic projections are supplied in production drawing, giving views of machine parts and their assembly in an accessible form. Sometimes an exploded from is given to explain the individual components.</p><h3>Additional characteristics of production drawings:</h3><ul><li>The production drawings may describe the preferred order in which to assemble components.</li><li>If the engineering drawings call for a screw fastener to be tightened, the production drawings would typically describe the tool to be used and how it should be calibrated.</li><li>Material and component specifics are also commonly provided in the title block of a production drawing.</li><li>Assemblies of components are usually shown and the production drawings may specify where each assembled component will be built.</li><li>Production drawings also record the number of parts that are required for making the assembled unit and may be required to authorise the production of the item described.</li></ul><p>Take a look at the example of production drawing of a<em> Companion Flange</em> and notice how it is different from engineering drawing:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/640/0*xU_JU-koTbA5uHLD.png" /></figure><p>This component actually looks something like this :</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/312/0*c8u57g3ibAuPyIT1.jpeg" /><figcaption>Front View</figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/169/0*yDUkZpRBlT11RPUW.jpeg" /><figcaption>Side View</figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/276/0*foYEn0nSM2ji0Bq-.jpeg" /><figcaption>Isometric View 1</figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/291/0*NPrG1YzGFYgHOx4Y.jpeg" /><figcaption>Isometric view 2</figcaption></figure><p>Notice how the drawing specifies all geometrical and dimensional constraints that a manufacturer should consider while manufacturing the component. To understand what the constraints are, and what each symbol means, let us first study what is meant by tolerance.</p><h3>What is meant by Tolerance?</h3><p>The permissible variation of a size is called tolerance. It is the difference between the maximum and minimum permissible limits of the given size. Tolerance can be given in two directions of basic size. On that basis, it can be:</p><p>1. <strong>Unilateral Tolerance:</strong> If the variation is provided on one side of the basic size, it is termed as unilateral tolerance.</p><p>2. <strong>Bilateral Tolerance:</strong> If the variation is provided on both sides of the basic size, it is known as bilateral tolerance.</p><p>Great care and judgement must be exercised in deciding the tolerances which may be applied on various dimensions of a component. If tolerances are to be minimum, that is, if the accuracy requirements are severe, the cost of production increases. In fact, the actual specified tolerances dictate the method of manufacture. Hence, maximum possible tolerances must be recommended wherever possible.</p><h3>Types of Tolerance:</h3><h4>1. Dimensional Tolerances:</h4><p>It is the total amount of a specific dimension permitted to vary from its basic size, which is the difference between maximum and minimum permitted limits of sizes of that feature.</p><p>Dimensional tolerances are shown in drawings by three methods:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/274/0*cw35hZ1AVrXcBYDW.png" /></figure><p>Eg: The maximum and minimum values for radius of the companion flange is shown by method 1, as highlighted in the drawing below.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/314/0*KaGFQH9ie4bBQKaF.png" /></figure><p>The dimensional tolerance over the radius of the component can be at maximum, 100 mm and at minimum, 99 mm.</p><h4>2. Geometrical Tolerances</h4><p>Geometrical tolerances are used to convey in a brief and precise manner the complete geometrical requirements on engineering drawings. They should always be considered for surfaces which come into contact with other parts, especially when close tolerances are applied to the features concerned.</p><p>Geometrical tolerances are indicated on drawings by symbols, tolerances and datum references, all contained in compartments of a rectangular frame, which looks like follows:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/531/0*mnCOWc_61UJf1CDK.png" /></figure><p>This set of representation is known as a <em>drawing callout</em>. A lot of useful information about the tolerances over a feature can be given via a callout.</p><p>As we saw earlier, GD&amp;T is an engineer’s code language. Each type of geometric tolerance has its own specific symbol.</p><p>Refer to the table below to understand what geometric characteristics can be given a tolerance and what are the symbols to represent them.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/640/0*2oFW4Ze0fKn95zH7.png" /></figure><p>Now, let us consider the above example of production drawing of a Companion Flange (used in drive shafts for effective power transmission) and go through each tolerance mentioned in it and understand what it means:</p><p><em>Let’s take a look at all the </em><strong>dimensional tolerances</strong><em> mentioned in the side view of the drawing:</em></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/640/0*BkBz3jdi94wNdyPn.png" /></figure><p>All the highlighted parts above indicate the dimensional tolerances on the features indicated.</p><p><em>Now, let us move on to the </em><strong>geometric tolerances:</strong></p><p><strong>1. Perpendicularity:</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/294/0*-hiMHanCkW30ILzh.png" /><figcaption>Perpendicularity Tolerance</figcaption></figure><p>The highlighted callout describes the perpendicularity of feature w.r.t. datum A, which is 0.08 mm in terms of diametric dimensions.</p><p>In other words, two parallel planes or lines are oriented perpendicular to the datum feature or surface 0.08 mm apart. These planes are held perpendicular to the datum, but only ensure that the entire feature falls within the tolerance zone of 8 microns.</p><p><strong>2. Parallelism:</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/320/0*gF7sH8BQwO1R61Lx.png" /><figcaption>Parallelism Tolerance</figcaption></figure><p>This callout represents that the indicated feature is parallel to datum A within 0.06 mm. Su<strong>rface Parallelism</strong> is a tolerance that controls parallelism between two <em>surfaces</em> or features. The surface form is controlled similar to flatness with two parallel planes acting as its tolerance zone. In this case, the tolerance zone being 0.06 mm on either side of nominal dimension of the feature.</p><p><strong>3. Threading and Positioning:</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/314/0*NMF1a--iwr1L2WLI.png" /><figcaption>Threading Specifications and its Position Tolerance</figcaption></figure><p>In this callout, M42 refers to Metric thread of 42 mm diameter and having pitch 1.5 mm. 6g is the tolerance class on the major diameter of the thread. The geometric tolerance is of the position of the centre of the M42 hole.</p><p>Position tolerance is defined as the total permissible variation that a feature can have from its “true” position. This callout signifies that the centre of the M42 thread is restricted to be within an imaginary cylinder of 0.1 mm diameter with the datum B (highlighted axis) as the centre.</p><p>The symbol of M enclosed in a circle stands for Maximum Material Condition.</p><p><strong>4. Flatness:</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/314/0*fjdOWxJfJ-GoicmG.png" /><figcaption>Flatness Tolerance</figcaption></figure><p>Flatness is a straightforward GD&amp;T symbol indicating how flat a feature should be regardless of any datum. The flatness tolerance references two parallel planes (parallel to the surface that it is called out on) that define a zone where the entire feature surface must lie. Flatness tolerance is always less than the dimensional tolerance associated with it.</p><p>In this case, the indicated surface must lie enclosed within two planes defined at 0.01 mm on both sides of the feature, i.e., flatness of entire surface is constrained within 0.02 mm.</p><p><strong>5. Radial Run-out:</strong></p><p>This type of tolerance is typically used for features which rotate about an axis, i.e., circular parts.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/314/0*kNsbm2lEo2Gdv4I4.png" /><figcaption>Radial Runout tolerance</figcaption></figure><p>Runout is how much one given feature can vary with respect to another datum when the part is rotated 360° around a datum’s axis. It is essentially how much “wobble” the feature’s surface has when it is rotated about the axis of the datum.</p><p>So, in this case, for the 20 mm diameter hole, runout is specified as 0.14 mm from datum A and C, which means when rotated about these datums, the surface of the hole should lie within 140 microns. Similarly, for the circular feature of diameter 31.6 mm, radial runout is 100 microns w.r.t. datum B.</p><p>And finally, moving on to the callout on the front view,</p><p><strong>6. Positioning and Holes:</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/320/0*mJNqtU90T7NJ7wOw.png" /><figcaption>Specifying number of holes and their type along with position tolerance</figcaption></figure><p>The callout says 8X, i.e., the tolerance mentioned is the same for 8 holes, which are given to be 45◦ apart placed symmetrically around the circular part.</p><p>The diameter of the holes have a dimensional tolerance between 7.9 mm — 8.1 mm. The position of the centre axis of the holes are restricted to be within 0.14 mm of the axes of datums A and C.</p><p>The dimension of Φ86 is a basic dimension and does not have tolerance. However, it must be kept as close as possible to given dimension for proper alignment of holes in the part.</p><p>Hope this walkthrough of basic tolerances has been helpful for you future engineers!</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=1d0fc94f45eb" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Fuel Cell Electric Vehicles]]></title>
            <link>https://engineeringandindustry.medium.com/fuel-cell-electric-vehicles-ea4bc9e0b520?source=rss-5c9e39dc8b83------2</link>
            <guid isPermaLink="false">https://medium.com/p/ea4bc9e0b520</guid>
            <category><![CDATA[fuel-cell-market]]></category>
            <category><![CDATA[fuel-cell]]></category>
            <category><![CDATA[electric-car]]></category>
            <category><![CDATA[fuel-cell-vehicles]]></category>
            <category><![CDATA[fuel-cell-india]]></category>
            <dc:creator><![CDATA[ENGINEERS IN MAKING]]></dc:creator>
            <pubDate>Thu, 24 Dec 2020 11:04:59 GMT</pubDate>
            <atom:updated>2021-05-10T04:15:24.655Z</atom:updated>
            <content:encoded><![CDATA[<p>Along with battery electric vehicles, there is a lot of buzz about use of fuel cell technology for driving electric vehicles. Both battery EVs and FCEVs are equally green and are considered as potential replacement to IC engine vehicles.</p><p>Although battery electric vehicles and fuel cell electric vehicles appear nearly same, they majorly differ in production and harvesting of electricity. As the name goes, fuel cell EVs use fuel cell as their energy source. One of the most common fuel used for fuel cell is hydrogen. The hazardous effects of pollutants from conventional fuel vehicles have caused the scientific world to move towards environmentally friendly energy sources. Though we have various renewable energy sources, the perfect one to use as an energy source for vehicles is hydrogen.</p><p><strong>About Hydrogen:</strong></p><p>One of the major reasons for hydrogen being used as fuel is its energy density. Hydrogen has energy density of around 33000watt hour/kg. Because of this major reason it has been used earlier in space programs and submarines. Comparing this to other energy sources, petrol has energy density of 3000watt hour/kg and Li ion batteries stand with just 200–300-watt hour/kg.</p><p><strong>Knowing more about Fuel cell:</strong></p><p>If we have to define fuel cell then, it is an electrochemical device that can produce electricity by allowing chemical gases and oxidants as reactant. With anodes and electrolytes, the fuel cell splits the cation and the anion in the reactant to produce electricity. Fuel cells use reactants, which are not harmful to the environment and produce water as a product of the chemical reaction. The reaction between hydrogen and oxygen can be used to generate electricity via a fuel cell.</p><p>A simple diagram below shows operation of fuel cell</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/334/0*hhHbCwz_OGGuRBoQ.png" /></figure><p>Fig: Operation of Fuel Cell</p><p>The most common type of fuel cell for vehicle applications is the polymer electrolyte membrane (PEM) fuel cell. In a PEM fuel cell, an electrolyte membrane is sandwiched between a positive electrode (cathode) and a negative electrode (anode). Hydrogen is introduced to the anode, and oxygen (from air) is introduced to the cathode. The hydrogen molecules break apart into protons and electrons due to an electrochemical reaction in the fuel cell catalyst. Protons then travel through the membrane to the cathode.</p><p>The electrons are forced to travel through an external circuit to perform work (providing power to the electric car) then recombine with the protons on the cathode side, where the protons, electrons, and oxygen molecules combine to form water.</p><p><strong>Fuel cell EV:</strong></p><p>The figure below shows basic fuel cell electric vehicle</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/400/0*Du1o-GeaWOJ3FPVM.png" /></figure><p>Fig: Basic Fuel Cell Electric Vehicle</p><p>The electricity generated in the fuel cell of a hydrogen engine can take two routes, depending on the demands of the specific driving situation. It either flows to the electric motor and powers the FCEV directly or it charges a battery, which stores the energy until it’s needed for the engine. This battery, known as a Peak Power Battery, is significantly smaller and therefore lighter than the battery of a fully electric car, as it’s being constantly recharged by the fuel cell.</p><p><strong>Advantages of FCEVs:</strong></p><ul><li>As hydrogen has high energy density, FCEVs have a range of about 300–350 miles per fill/charge which is much better than BEVs.</li><li>The range of fuel cell vehicles is not dependent on the outside temperature.</li><li>Another major advantage of FCEVs is its charging time. Hydrogen tanks take merely 4–5 minutes to fill up to their full capacity.</li></ul><p><strong>Efficiency of fuel cell electric vehicles:</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/400/0*Q0YmUzjozDAR9JY1.jpg" /></figure><p>Fig: Efficiency of Fuel Cell Vehicle considering all conversions</p><p>Hydrogen fuel cell EVs look good with greater range and high energy density fuel but considering whole energy conversion cycle in today’s era, they stand with lesser efficiency.</p><p>Though hydrogen as an element is abundant in universe, it is mostly available in the form of hydro carbons. Pure hydrogen needs to be manufactured. This is done through two processes, electrolysis and natural gas reforming. During this conversion, almost 20% of energy is lost.</p><p>Further the PEM fuel cell are only 80% efficient so more 20% energy is lost in this case.<br>The most efficient AC/DC converter is itself 92% efficient which counts to more 8% loss.<br>Hydrogen needs to be compressed for its storage. This compression can be accounted as 12% of more energy. As the hydrogen infrastructure is not well developed, transportation losses account to 5%.</p><p>If we consider all the above factors then the final efficiency that we get is just about 35%</p><p><strong>Major disadvantages:</strong></p><p>As mentioned earlier, considering technological development in up till now, fuel cell vehicles have very low energy chain efficiency. Infrastructure for hydrogen is not well developed and will require considerable amount of investment from all countries.</p><p>The natural gas reforming method of producing hydrogen is also not a green process and has large amounts of carbon emissions.</p><p>Moreover, the production cost of hydrogen itself is high. The E-ROI of hydrogen is less than 1 which makes it even more difficult for its use as fuel for vehicles. This also makes manufacturing and running cost of FCEVs quite high as compared to battery electric vehicles.</p><p><strong>Scenario in India:</strong></p><p>Tata Motors, in collaboration with Indian Oil Corporation, just flagged off the country’s first hydrogen fuel cell powered bus. The bus is named Fuel Cell Starbus. The test results generated power of 85 kW at 275 VDC, which is capable of running Fuel cell bus up to 450 km with single refuelling of on-board hydrogen.</p><p>India currently has two hydrogen refuelling stations. One, at Indian Oil R&amp;D Centre, Faridabad and other at National Institute of Solar Energy, Gurugram.</p><p>India’s largest power producer and a central PSU under Ministry of Power, NTPC Ltd, has invited global expression of interest (EoI) to provide 10 Hydrogen fuel cell (FC) based electric buses and an equal number of Hydrogen Fuel Cell-based electric cars in Leh and Delhi.</p><p>The move to launch hydrogen-powered vehicles aims at decarbonizing the mobility segment.</p><p><strong>Future of FCEVs:</strong></p><p>Though the FCEVs stand below battery electric vehicles in today’s scenario, with growth in hydrogen infrastructure we could see more and more hydrogen-based FCEVs.</p><p>Countries like China, Japan are investing in fuel cell technology and are aiming to have around 1 million running FCEVs by 2030.</p><p>Although hydrogen fuel cell may not seem suitable for passenger vehicles, it can find its use in heavy duty transport and marine vehicles.</p><p>With all these points, as of now we can say that battery electric vehicles are going stay and rule for this decade at least.</p><p>Writers: Dhiraj Ghode, Hrishikesh Gawand, Ranveer Ghorpade, Sanika Gaykar, Sankalp Gharmalkar</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=ea4bc9e0b520" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>