<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Indee Labs on Medium]]></title>
        <description><![CDATA[Stories by Indee Labs on Medium]]></description>
        <link>https://medium.com/@indeelabs?source=rss-cc3b372b101a------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/1*LNkIe251XHfLbks7u3rxpQ.png</url>
            <title>Stories by Indee Labs on Medium</title>
            <link>https://medium.com/@indeelabs?source=rss-cc3b372b101a------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Sat, 28 Nov 2026 16:54:01 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@indeelabs/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[What is Microfluidic Vortex Shedding?]]></title>
            <link>https://medium.com/@indeelabs/what-is-microfluidic-vortex-shedding-54e91b3630c9?source=rss-cc3b372b101a------2</link>
            <guid isPermaLink="false">https://medium.com/p/54e91b3630c9</guid>
            <category><![CDATA[bioengineering]]></category>
            <category><![CDATA[microfluidics]]></category>
            <category><![CDATA[innovation]]></category>
            <category><![CDATA[pharmaceutical]]></category>
            <category><![CDATA[biotechnology]]></category>
            <dc:creator><![CDATA[Indee Labs]]></dc:creator>
            <pubDate>Wed, 24 Mar 2021 20:38:21 GMT</pubDate>
            <atom:updated>2021-03-24T20:52:51.023Z</atom:updated>
            <content:encoded><![CDATA[<p><strong>By Fong L. Pan, B.Sci M.Sci. — </strong>Simulations Engineer @ <a href="https://www.indeelabs.com/"><strong>Indee Labs</strong></a>.</p><p>Original blog post available <a href="https://www.indeelabs.com/articles/what-is-microfluidic-vortex-shedding"><strong>here</strong></a>.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*MieuoMe8i3mtzYcOwnyc_A.png" /></figure><h3>Microfluidic vortex shedding</h3><p>Microfluidic vortex shedding (<em>µVS</em>) has been shown to enable the efficient delivery of various constructs like mRNA, plasmid DNA and Cas9 RNPs (CRISPR) to primary human T cells [1]. But, what is <em>µVS</em>? And, how does <em>µVS</em> enable intracellular delivery of constructs to primary cells like activated T cells?</p><p>In this blog post, we provide some background on vortex shedding and use single-phase simulation to explain what happens to cellVortex shedding and the related Kármán vortex street are not novel. These phenomena can be found in rivers or streams as they flow past boulders, and even in the clouds as they move past mountains or islands. Vortex shedding has also been used to precisely mix fluids on the microscale [2].</p><p>The gist of it is, vortex shedding has been well-studied and for a while [3]. The team at Indee Labs, however, is the first to apply microfluidic vortex shedding (<em>µVS</em>) to gene delivery and has received a number of granted patents as a result.</p><p>During <em>µVS</em>, cells are mixed in suspension with the desired construct then exposed to hydrodynamic conditions or fluid forces sufficient to temporarily porate the cell membrane — this allows for constructs like Cas9 ribonucleoproteins (Cas9-RNPs) to enter the cell cytoplasm. Our current <em>µVS</em> prototypes can quickly process tens of million of cells while preserving native cell states1. This is measured by T cell activation, exhaustion, cytokine profiling and transcriptome-wide sequencing. Serendipitously, these are the ideal characteristics of an intracellular delivery technology for gene-modified cell therapies like chimeric antigen receptor T cells or CAR-T.</p><figure><img alt="Plots of the cytokine profiles for µVS relative to handling, media and activation controls" src="https://cdn-images-1.medium.com/max/1024/1*E3EVVZG3lA7CSq6YkwV8Gg.png" /><figcaption><strong>Plots of the cytokine profiles for <em>µVS</em> relative to handling, media and activation controls</strong></figcaption></figure><h3><strong>What is vortex shedding?</strong></h3><p>Vortex shedding occurs in the near wake of a bluff body due to instability created at the right flow conditions. Put simply, if you flow a fluid like air or water past a bluff body such as a post, boulder or mountain at the right conditions you create fluctuating flow fields along with drag and lift forces acting on the bluff body. This results in vortex shedding where a Kármán vortex street can frequently be observed.</p><p>For a cylindrical post, the onset of vortex shedding occurs at an object Reynolds number of about 40 (<em>Reo &gt; 40</em>)4. These vortex shedding patterns become more complicated with an increasing object Reynolds number or with increasing numbers of bluff bodies and their proximity.</p><figure><img alt="Vortex Shedding Regimes" src="https://cdn-images-1.medium.com/max/1024/1*f_Qx5IaprUOJtqnHB-ZLwQ.png" /><figcaption><strong>Overview of different vortex shedding regimes</strong></figcaption></figure><h3><strong>What is a Reynolds number?</strong></h3><p>In fluid dynamics, Reynolds number is the non-dimensional ratio of inertial forces to viscous forces. This means vortex shedding typically occurs when the inertial forces of a fluid flow around a bluff body are at least 40 times greater than the viscous forces acting on the fluid. For <em>Re_o &gt; 40, we should see downstream flow instability and resultant vortices. Herein, the Reynold number for flow past a bluff body is denoted as the object Reynolds number (Re</em>_o).</p><p>For the team at Indee Labs, understanding the intricacies of vortex shedding is essential. This knowledge allows us to engineer vortex shedding such that our <em>µVS</em> devices and protocols result in optimal yield or the percentage of recovered, viable and modified T cells.</p><p>In more detail, a numerical study of detailed wake patterns of laminar flow past microarrays platform is briefly presented here. Our standard <em>µVS</em> device geometry for activated T cells is used for this simulation. This array consists of 16 circular cylinders in side-by-side arrangements with total 6 columns in parallel positioned as shown below. The flow condition is considered laminar due to low flow cell (<em>Refc), channel (Rec) and gap (Reg</em>) Reynolds numbers.</p><p>Not all Reynolds numbers are alike and there are different Reynolds numbers for the flow cell, individual channels, gap and posts. Under typical <em>µVS</em> processing conditions for activated T cells, we see Reynolds numbers according to the table below.</p><figure><img alt="Reynolds Number and Value" src="https://cdn-images-1.medium.com/max/578/1*Mc2I6v11R2UwxUYILvq2MA.png" /></figure><p>Flow in the device flow cell and channels is definitively laminar. When considering flow through a flow cell and channels, laminar flow occurs between <em>1 &lt; Re &lt; 2,100</em> [4]. Thus, we know the vortices shown in the simulation below are likely a result of vortex shedding since the object Reynolds numbers estimated to be 146 or much greater than 40 while all other Reynolds numbers are much less than 2,100.</p><figure><img alt="Contour plot of instantaneous velocity for a transient simulated instantaneous flow field" src="https://cdn-images-1.medium.com/max/1024/1*AFq5rVsSxn7-5PTdRbA9Sw.png" /><figcaption><strong>Contour plot of instantaneous velocity for a transient simulated flow field (units are in m s-1).</strong></figcaption></figure><p>Vortex shedding as a result of flow past a single bluff body is one thing. Vortex shedding as a result of flow through a post array is an additional field of research. We are not the first to study flow over multiple cylinders, and a lot of the prior work has been focused on dual cylinders due to simple configuration [5–7]. Others have studied the effects of vortex shedding on more complex post arrays, however, this is to minimize vortices for high-fidelity cell separation and the opposite of our intent [8]. Select prior work concluded that flow could be summarized into two major regimes with a complex transition region between the two [9–12].</p><p>For two cylindrical posts in close proximity, the flow is periodic and the wake is a single Kármán vortex street as if the flow past a single bluff body. When the same two cylinders are further, coupled and synchronized vortex streets in the wake has been observed. Lastly, intermediate spacing leads to a very complex transitional patterns such as bi-stable biased gap flow as observed by Kim and Durbin [13].</p><figure><img alt="Plots of instantaneous vorticity contours" src="https://cdn-images-1.medium.com/max/1024/1*xR9JXM9btQaInzgIuB2Z3Q.png" /><figcaption><strong>Plots of instantaneous vorticity contours (left) and streamlines (right) for these wake patterns: (a) unsteady antiphase-synchronized, (b) unsteady in-phase-synchronized, © unsteady flip-flopping, (d) steady single bluff-body, (e) steady deflected and (f) steady pattern14.</strong></figcaption></figure><p>Sangmo has performed two-dimensional numerical studies on various dual cylinders arrangements at a range of low Reynolds number <em>40 &lt; Re_o &lt; 160</em> and a gap ratio (gap width / cylinder diameter) of less than 5 [14]. Sangmo’s numerical results have identified a total of six different kinds of wake patterns in the flow field. These wake patterns are named and categorized as the following, more detail of these patterns can be found from his paper:</p><ol><li><strong>Unsteady anti-phased synchronized pattern</strong></li><li><strong>Unsteady in-phased synchronized pattern</strong></li><li><strong>Unsteady flip-flopping pattern</strong></li><li><strong>Steady single bluff-body pattern</strong></li><li><strong>Steady deflected pattern</strong></li><li><strong>Steady pattern</strong></li></ol><p>Typically, the flow characteristics significantly depend both on the object Reynolds number and relative gap spacing [14].</p><h3><strong>What does this have to do with intracellular or gene delivery?</strong></h3><p>Well, at Indee Labs, we need to fine tune each <em>µVS</em> device geometry such that we create the optimal vortex shedding for intracellular delivery. As a starting point, we examined what happens in our standard <em>µVS</em> device when a single-phase flow is simulated at standard conditions.</p><figure><img alt="Contour plot and graph of pressure in a µVS device under typical processing conditions" src="https://cdn-images-1.medium.com/max/1024/1*_V807X1PjCdXjZ9wehmdyA.png" /><figcaption><strong>Contour plot and graph of pressure in a µVS device under typical processing conditions.</strong></figcaption></figure><p>As you can see from above, suspended cells flow through the post array and are pulsed with an approximately 1.4 ATM (20 psig) pressure drop followed by a 0.4 ATM (6 psig) pressure increase. If we use the results of the simulation described above to estimate flow speeds for approximate time scales, then the pressure drop occurs over about 2 <em>µs</em> and the pressure increase occurs over about 40 <em>µs</em>. And, while between post arrays, the cells and surrounding constructs are subject to a high degree of vorticity or ‘mixing.’ This is thought to enhance cell-construct interactions while the cell membrane remains permeable. Cumulatively, intracellular delivery is likely caused by the superposition or combination of both pressure changes and vorticity or ‘mixing.’ More specifically, the combination of these hydrodynamic fluid forces sufficiently permeabilizes the cell membrane to allow various constructs to enter the cell prior to modifying or engineering each cell.</p><p>Single-phase simulation is a great starting point, however, all simulations need to be verified experimentally. Plus, these single-phase simulations assume suspended cells have negligible effect on the fluid dynamics. Developing and verifying more accurate simulations will be no easy feat. This will require imaging objects with a diameter of 1/10 to 1/100 the thickness of a human hair while they are traveling at speeds as high as 20 m s-1 (45 mph).</p><p>We are working on a multi-phase computational model in order to expedite <em>µVS</em> device development for both T cells and other cell types. Verifying that model will involve imaging cell and particle trajectories at frame rates exceed 500,000 frames per second. Technical jargon aside, success with that project will allow us to more readily develop chips for alternative cell types and different processing media. This will accelerate development timelines as we move outside of just primary human T cells.</p><h3><strong>References</strong></h3><ol><li>Jarrell, Justin A., et al. “Intracellular delivery of mRNA to human primary T cells with microfluidic vortex shedding.” <em>Scientific reports</em> 9.1 (2019): 3214.</li><li>Renfer, Adrian, et al. “Vortex shedding from confined micropin arrays.” <em>Microfluidics and nanofluidics</em> 15.2 (2013): 231–242.</li><li>Bearman, Peter W. “Vortex shedding from oscillating bluff bodies.” <em>Annual review of fluid mechanics</em> 16.1 (1984): 195–222.</li><li>Gerhart, Philip M., Andrew L. Gerhart, and John I. Hochstein. <em>Munson, Young and Okiishi’s Fundamentals of Fluid Mechanics, Binder Ready Version</em>. John Wiley &amp; Sons, 2016</li><li>Deng Jian, Ren An-lu, and Zou Jian-Feng, “Three-dimensional flow around two tandem circular cylinders with various spacing at Re=220”, Journal of Hydrodynamics, Ser. B, 2006, 18(1): 48–54.</li><li>Sun Ren, Chwang Allen T., “Interaction of a floating elliptic cylinder with a vibrating circular cylinder”, Journal of Hydrodynamics, Ser. B, 2006, 18(4): 481–491.</li><li>Sumner D., Wong S. S., and Price S. J. et al, “Fluid behavior of side-by-side circular cylinders in steady cross-flow”, Journal of Fluids and Structures, 1999, 13(3): 309–338.</li><li>Dincau, Brian M., <em>et al.</em> “Deterministic lateral displacement (DLD) in the high Reynolds number regime: high-throughput and dynamic separation characteristics.” <em>Microfluidics and Nanofluidics</em> 22.6 (2018): 59.</li><li>Bearman P. W., Wadcock A. J., “The interaction between a pair of circular cylinders normal to a stream”, Journal of Fluid Mechanics, 1973, 61: 499–511.</li><li>Kiya M., Arie M., and Tamura H. et al, “Vortex shedding from two circular cylinders in staggered arrangements”, ASME Journal of Fluids Engineering, 1980, 102(2): 166–173.</li><li>Zdravkovich M. M. “Flow induced oscillations of two interfering circular cylinders”, Journal of Sound and Vibration, 1985, 101(4): 511–521.</li><li>Williamson C. H. K., “Evolution of a single wake behind a pair of bluff bodies”, Journal of Fluid Mechanics, 1985, 159: 1–18.</li><li>Kim H. J., Durbin P. A., “Investigation of the flow between a pair of circular cylinders in the flopping regime”, Journal of Fluid Mechanics, 1988, 196: 431–448.</li><li>Sangmo K., “Characteristics of flow over two circular cylinders in a side-by-side arrangement at low Reynolds number”, Physics of Fluids 15, 2486 (2003).</li></ol><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=54e91b3630c9" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[The Problem with Gene-Modified Cell Therapy Manufacturing]]></title>
            <link>https://medium.com/@indeelabs/the-problem-with-gene-modified-cell-therapy-manufacturing-550dc96bd3c8?source=rss-cc3b372b101a------2</link>
            <guid isPermaLink="false">https://medium.com/p/550dc96bd3c8</guid>
            <category><![CDATA[biotechnology]]></category>
            <category><![CDATA[pharmaceutical]]></category>
            <category><![CDATA[microfluidics]]></category>
            <category><![CDATA[gene-therapies]]></category>
            <category><![CDATA[innovation]]></category>
            <dc:creator><![CDATA[Indee Labs]]></dc:creator>
            <pubDate>Wed, 24 Mar 2021 20:21:29 GMT</pubDate>
            <atom:updated>2021-03-24T21:29:03.359Z</atom:updated>
            <content:encoded><![CDATA[<p>And Microfluidic Vortex Shedding as a Solution for Non-Viral Delivery</p><p><strong>By</strong> <a href="https://www.linkedin.com/in/rpawell/"><strong>Ryan Pawell</strong></a><strong> — </strong>Founder, CEO &amp; Managing Director @ <a href="https://www.indeelabs.com/"><strong>Indee Labs</strong></a><strong>.</strong></p><figure><img alt="Scientist holding petri dish in lab hood" src="https://cdn-images-1.medium.com/max/1024/1*t2ziF13U2j-qWUoD4N155A.png" /></figure><p><strong>Gene-modified cell therapies (GMCTs)</strong> represent the most effective therapeutic platform for many patients with advanced diseases including relapsed and refractory leukemia, non-Hodgkin lymphoma, and other blood cancers [1]. Specifically, chimeric antigen receptor T cell (CAR-T) therapies targeting CD19 have demonstrated remarkable responses and possibly cures in patients with advanced acute lymphoblastic leukemia (ALL) that were unresponsive to all prior therapies. Gene modified CAR-T cells are the first cellular therapy to gain FDA approval for treatment of cancer following demonstration of an 83% remission rate in ALL [2].</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*z-RDAqiIQ8gAOcDhXNaNvQ.png" /><figcaption><strong>CAR-T cells are generated via genetic modification of human T cells to display an extracellular antibody single-chain variable fragment (scFv) linked to a hinge region, one or more co-stimulatory domain(s), and an intracellular activating domain. Image from </strong><a href="https://www.indeelabs.com/"><strong>Indee Labs.</strong></a></figcaption></figure><p>The most problematic step in GMCT manufacturing is the intracellular delivery of nucleic acids via transfection or transduction for expression of the CAR by the T cell. Viral transduction using lentiviruses is the method currently used to generate CAR-T therapies for clinical trial. However, these methods require significant hands-on time during production and require extensive intra- and post-production safety testing to avoid infusion of replication competent viruses at the time of therapy administration [3,4].</p><p>There are several practical metrics when considering intracellular delivery for GMCT development and manufacturing, including:</p><ol><li><strong>Cell recovery</strong></li><li><strong>Cell viability</strong></li><li><strong>Delivery or expression efficiency</strong></li><li><strong>Throughput</strong></li><li><strong>Maintenance of normal or desired cell state and function.</strong></li></ol><p>Physical transfection methods, such as electroporation, are appealing alternatives for GMCT manufacturing [5,6]. Electroporation does not require extensive safety or release precautions and can be used to deliver a broad range of constructs into cells (e.g. DNA, RNA, proteins and/or various complexes), but can result in significant cell losses or alteration of normal cell function [7,8].</p><p>Low cell recovery rates are not ideal due to the large number of cells required for GMCTs. High cell viability is also essential as cells are frequently expanded after modification and low cell viability or the presence of dead cells is known to reduce cell growth rates. Additionally, nonviable cells can induce an adverse immune response9 Regulators require a minimum percentage of viable cells for cell therapies as low cell viability at the time of administration can induce infusion toxicity and lessened therapeutic effect [10,11].</p><p>Delivery should induce a therapeutic effect without altering cell state, and efficiency of cell modification needs to be sufficiently high to avoid the need for additional processing steps like dead cell removal. Zhang et al. used electroporation to transfect naïve T cells with plasmids and found recovery rates to be less than 20% after 24 hours [7]. In addition to greatly reducing viability, electroporation increased expression of T cell surface activation markers, which requires additional post transfection recovery time before therapy administration [7].</p><h3><strong>Intracellular delivery via microfluidic vortex shedding</strong></h3><p><a href="https://www.indeelabs.com/"><strong>Indee Labs</strong></a> is the first to apply microfluidic vortex shedding (<em>µVS</em>) to intracellular delivery, where the fluid forces or hydrodynamic conditions created during <em>µVS</em> are used to gently and temporarily porate the cell membrane, allowing for gene delivery in a novel manner.</p><p>Specifically, these microfluidic devices use a tiny array of posts to induce a well-known fluid dynamics phenomenon called vortex shedding. You can observe vortex shedding in nature by watching as clouds drift past mountains or as streams flow past rocks and boulders.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*vwGX0eoT41T1FGTAKezb5w.png" /><figcaption><strong>Image from </strong><a href="https://www.indeelabs.com/"><strong>Indee Labs</strong></a></figcaption></figure><p>Microfluidics are being used to actively improve upon traditional intracellular delivery methods [12,13]. However, a substantial need for a practical microfluidic intracellular delivery method remains, particularly within the scope of GMCT development and manufacturing. At <a href="https://www.indeelabs.com/"><strong>Indee Labs</strong></a>, we have developed a hydrodynamic intracellular delivery platform based on <em>µVS</em>.</p><p>We have optimized our platform for enhanced green fluorescent protein (EGFP) mRNA delivery to human pan T cells [14]. We demonstrate <em>µVS</em> results in</p><ol><li><strong>High cell recovery (e.g., 96.3 ± 1.1%, mean ± stdev),</strong></li><li><strong>High cell viability (e.g., 83.7 ± 0.7%) and</strong></li><li><strong>High EGFP expression efficiency (e.g., 57.4 ± 6.8%) resulting a</strong></li><li><strong>Yield of 46.3 ± 5.6% recovered, viable, and EGFP expressing pan T cells after intracellular delivery.</strong></li></ol><p>We also demonstrate:</p><ol><li><strong><em>µVS</em> does not adversely affect T cell growth.</strong></li><li><strong><em>µVS</em> results in even EGFP expression profiles amongst T cell types.</strong></li><li><strong><em>µVS</em> does not change T cell activation profiles.</strong></li></ol><p>Now, we are developing a <a href="https://indeelabs.com/technology/"><strong>user-friendly <em>µVS</em> instrument</strong></a> for research then clinical use in collaboration with the Westmead Institute for Medical Research and funded by NSW Health.</p><p>These <em>µVS</em> devices have the potential to completely eliminate the two primary barriers to widespread gene-modified cell therapy like CAR-T: cost and scalability. The device may also reduce or even eliminate many of the challenges described above.</p><p>Visit <a href="https://www.indeelabs.com/"><strong>indeelabs.com</strong></a> and subscribe to our newsletter to stay up-to-date on our progress as we work towards practical and scalable gene-modified cell therapies like CAR-T.</p><h3><strong>References</strong></h3><ol><li>Kochenderfer, J. N. et al. Long-Duration Complete Remissions of Diffuse Large B Cell Lymphoma after Anti-CD19 Chimeric Antigen Receptor T Cell Therapy. Mol. Ther. J. Am. Soc. Gene Ther. 25, 2245–2253 (2017).</li><li>Ledford, H. Engineered cell therapy for cancer gets thumbs up from FDA advisers. Nat. News 547, 270 (2017).</li><li>Wang, X. &amp; Rivière, I. Clinical manufacturing of CAR T cells: foundation of a promising therapy. Mol. Ther. Oncolytics 3, 16015 (2016).</li><li>Levine, B. L., Miskin, J., Wonnacott, K. &amp; Keir, C. Global Manufacturing of CAR T Cell Therapy. Mol. Ther. — Methods Clin. Dev. 4, 92–101 (2017).</li><li>Stewart, M. P. et al. In vitro and ex vivo strategies for intracellular delivery. Nature 538, 183–192 (2016).</li><li>Ramanayake, S. et al. Low-cost generation of Good Manufacturing Practice-grade CD19-specific chimeric antigen receptor-expressing T cells using piggyBac gene transfer and patient-derived materials. Cytotherapy 17, 1251–1267 (2015).</li><li>Zhang, M. et al. The impact of Nucleofection® on the activation state of primary human CD4 T cells. J. Immunol. Methods 408, 123–131 (2014).</li><li>Liu, L., Johnson, C., Fujimura, S., Teque, F. &amp; Levy, J. A. Transfection optimization for primary human CD8+ cells. J. Immunol. Methods 372, 22–29 (2011).</li><li>Peng, Y. et al. Innate and adaptive immune response to apoptotic cells. J. Autoimmun. 29, 303–309 (2007).</li><li>Morgenstern, D. A. et al. Post-thaw viability of cryopreserved peripheral blood stem cells (PBSC) does not guarantee functional activity: important implications for quality assurance of stem cell transplant programmes. Br. J. Haematol. 174, 942–951 (2016).</li><li>Watts, M. J. &amp; Linch, D. C. Optimisation and quality control of cell processing for autologous stem cell transplantation. Br. J. Haematol. 175, 771–783 (2016).</li><li>Ding, X. et al. High-throughput Nuclear Delivery and Rapid Expression of DNA via Mechanical and Electrical Cell-Membrane Disruption. Nat. Biomed. Eng. 1, (2017).</li><li>Woodruff, K. &amp; Maerkl, S. J. A High-Throughput Microfluidic Platform for Mammalian Cell Transfection and Culturing. Sci. Rep. 6, 23937 (2016).</li><li>Twite, A. et al. Intracellular delivery of mRNA to human primary T cells with microfluidic vortex shedding. bioRxiv (2018).</li></ol><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=550dc96bd3c8" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>