<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Millatina M Putri on Medium]]></title>
        <description><![CDATA[Stories by Millatina M Putri on Medium]]></description>
        <link>https://medium.com/@millatinamp?source=rss-7b2b8ba908e4------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/0*v20fBIWnP5sCE7Zh</url>
            <title>Stories by Millatina M Putri on Medium</title>
            <link>https://medium.com/@millatinamp?source=rss-7b2b8ba908e4------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Sun, 22 Nov 2026 22:30:32 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@millatinamp/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Can we just send all the electricity we generate through the transmission line?]]></title>
            <link>https://medium.com/@millatinamp/can-we-just-send-all-the-electricity-we-generate-through-the-transmission-line-e3c5afc606a0?source=rss-7b2b8ba908e4------2</link>
            <guid isPermaLink="false">https://medium.com/p/e3c5afc606a0</guid>
            <category><![CDATA[transmission]]></category>
            <category><![CDATA[renewable-energy]]></category>
            <category><![CDATA[energy]]></category>
            <category><![CDATA[engineering]]></category>
            <category><![CDATA[electricity-distribution]]></category>
            <dc:creator><![CDATA[Millatina M Putri]]></dc:creator>
            <pubDate>Fri, 02 Oct 2026 18:45:01 GMT</pubDate>
            <atom:updated>2026-10-02T18:45:01.721Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/792/1*4BfDyXNVI3Rif_03vyTH-Q.jpeg" /></figure><p>I’m currently working on a feasibility study of a new wind farm project in Eastern Eyre Peninsula, South Australia. A model representing the <a href="https://www.aemo.com.au/energy-systems/electricity/national-electricity-market-nem">National Electricity Market (NEM)</a> is currently being built where it not only considers the generation and demand constraints, but also the transmission itself. With this model, we can simulate how much revenue the wind farm is able to get during its lifecycle and the client will be able to make an informed decision.</p><p>Before this, my <a href="https://handbook.unimelb.edu.au/2022/subjects/engr90032">Energy Supply and Value Chain </a>class has taught me how to model the electricity network and conduct renewable project feasibility, so this is not something new for me. What I understand was, to model a transmission, we should consider the line’s thermal limits. Honestly, I thought this was the only constraint, apparently not.</p><p>Based on <a href="https://www.aemo.com.au/energy-systems/electricity/national-electricity-market-nem/nem-forecasting-and-planning/forecasting-and-reliability/nem-electricity-statement-of-opportunities-esoo">AEMO’s published 2026 NEM Electricity Statement of Opportunities (ESOO)</a>, AEMO includes multiple parameters in their transmission constraints:</p><ol><li><strong>Thermal limit (line overload): </strong>Represents the maximum power flow the line can accommodate before it heats up, deteriorates, and potentially causes damage.<em> E.g. S&gt;&gt;S_NIL_HUWT1: This constraint limits power flow on the Waterloo to Hummocks 132kV line during normal system operation.</em></li><li><strong>Voltage constraints (voltage collapse): </strong>The voltages at the receiving end of the transmission line will fluctuate depending on the total power flow sent from the source. The network operator needs to make sure this voltage is maintained within an acceptable band (typically around 5–10%). Operating above this will cause the system to fail or trip. Unlike thermal limits that are applicable per line, voltage constraints are often expressed as a system-wide boundary. <em>E.g. S^NIL_SA_NORTH: This constraint limits total generation in Northern SA, so that if one of the 275kV lines between Davenport and Para or Tungkillo were to trip, the voltage at the receiving end would not collapse.</em></li><li><strong>Stability constraints (transient / oscillatory): </strong>Even if a line is not thermally overloaded or the voltage is within its limit, the system will still need to protect itself from a sudden change or fault. In AEMO, these are often expressed as a conservative constraints as they protect the system against a worst-case scenario rather than normal operating conditions. <em>E.g. S:VS_800: Caps the combined Heywood and Murraylink flow at 800 MW to avoid power oscillations growth. The constraint makes sure that if there’s disturbance, it will die instead of escalating into uncontrolled oscillation and trip the system.</em></li><li><strong>System strength: </strong>Sets a minimum level of synchronous generators running to maintain the grid’s protection system working reliably. Synchronous generators provide this naturally through the physics of spinning turbines (which inverter-based resources cannot). <em>E.g. S_NIL_STRENGTH_1: Set a maximum limit on South Australian non-synchronous generation, to make sure enough synchronous generators remain online.</em></li></ol><p>So no, you can’t just send all the electricity you generate. It’s not enough to consider the thermal limit of the line. We need to consider at least these four constraints to know how much electricity actually makes it through</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=e3c5afc606a0" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>