<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Neal Wareing on Medium]]></title>
        <description><![CDATA[Stories by Neal Wareing on Medium]]></description>
        <link>https://medium.com/@nealjameswareing?source=rss-80a5ca657d36------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/1*HOd8nQgWf8617PMtDIWB-g.jpeg</url>
            <title>Stories by Neal Wareing on Medium</title>
            <link>https://medium.com/@nealjameswareing?source=rss-80a5ca657d36------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Thu, 19 Nov 2026 14:36:35 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@nealjameswareing/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[UK electricity generation per person has been falling for 20 years.]]></title>
            <link>https://medium.com/@nealjameswareing/uk-electricity-generation-per-person-has-been-falling-for-20-years-1547f0a0b02d?source=rss-80a5ca657d36------2</link>
            <guid isPermaLink="false">https://medium.com/p/1547f0a0b02d</guid>
            <category><![CDATA[field-service-technician]]></category>
            <category><![CDATA[findfst]]></category>
            <category><![CDATA[field-service]]></category>
            <category><![CDATA[industrial-maintenance]]></category>
            <category><![CDATA[energy]]></category>
            <dc:creator><![CDATA[Neal Wareing]]></dc:creator>
            <pubDate>Sun, 15 Nov 2026 19:46:55 GMT</pubDate>
            <atom:updated>2026-11-15T19:50:30.851Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*DUfPxiXVhP9eRS0f" /></figure><p>Some of the UK drop is efficiency. LEDs, better motors, better drives. That’s fine.</p><p>Some of it is factories that shut or moved abroad. That’s a problem.</p><p>Coal is gone. Gas and nuclear are down. Renewables have grown, but not enough to fill the hole, so more of our power is now imported.</p><p>We switched off power we could control faster than we replaced it. And the power we replaced it with doesn’t run when the wind drops or the sun isn’t shining (which is most of the year in the UK).</p><p>The UK now has the highest industrial electricity prices of any IEA country. When power costs that much, nobody builds a production line here.</p><p>They build it somewhere else and ship the product in, France for example. Cheap, abundant electricity is what makes it worth building things here. Factory floors, skilled trades, the local butty van all benefit.</p><p>Every machine I’ve ever commissioned needed one thing before anything else.</p><p>Power.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*sHSgUh9W630KI2ZK" /></figure><p><em>Originally published at </em><a href="https://www.findfst.com/life/uk-electricity-generation-per-person-has-been-falling-for-20-years"><em>https://www.findfst.com</em></a><em> on November 16, 2026.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=1547f0a0b02d" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Wireway covers belong back on, even the ones we didn’t remove… | FindFST]]></title>
            <link>https://medium.com/@nealjameswareing/wireway-covers-belong-back-on-even-the-ones-we-didnt-remove-findfst-301ac6a2ae84?source=rss-80a5ca657d36------2</link>
            <guid isPermaLink="false">https://medium.com/p/301ac6a2ae84</guid>
            <category><![CDATA[manufacturing]]></category>
            <category><![CDATA[field-service]]></category>
            <category><![CDATA[electrical-engineering]]></category>
            <category><![CDATA[technician]]></category>
            <category><![CDATA[field-service-technician]]></category>
            <dc:creator><![CDATA[Neal Wareing]]></dc:creator>
            <pubDate>Tue, 27 Oct 2026 10:02:03 GMT</pubDate>
            <atom:updated>2026-10-27T10:01:17.470Z</atom:updated>
            <content:encoded><![CDATA[<p>Wire cuttings belong in the bin, not on the floor. Leaving a mess behind says a lot about attitude. Customers notice. They might not mention it on the day, but it registers. When the next job comes around, they remember the engineer who left things tidy. A site visit is the technical fix, report, and the state of the place when you leave. Tidying up wire cuttings and putting covers back you never took off is part of the job.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/928/0*7xD23Mfwc80wpNHD" /></figure><ul><li>Field Service</li><li>Controls Engineering</li><li>Industrial Maintenance</li></ul><p><em>Originally published at </em><a href="https://www.findfst.com/life/wireway-covers-belong-back-on-even-the-ones-we-didn-t-remove"><em>https://www.findfst.com</em></a><em> on December 23, 2026.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=301ac6a2ae84" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Looks fine. No comms. | FindFST]]></title>
            <link>https://medium.com/@nealjameswareing/looks-fine-no-comms-findfst-d08855945bd6?source=rss-80a5ca657d36------2</link>
            <guid isPermaLink="false">https://medium.com/p/d08855945bd6</guid>
            <category><![CDATA[findfst]]></category>
            <category><![CDATA[fault-finding]]></category>
            <category><![CDATA[industrial-maintenance]]></category>
            <category><![CDATA[field-service-technician]]></category>
            <category><![CDATA[field-service]]></category>
            <dc:creator><![CDATA[Neal Wareing]]></dc:creator>
            <pubDate>Mon, 26 Oct 2026 18:59:16 GMT</pubDate>
            <atom:updated>2026-10-27T09:56:43.884Z</atom:updated>
            <content:encoded><![CDATA[<p>Profinet plug was in the right port, nothing obviously wrong. But the machine wasn’t talking. Then look closer and you can see the profinet plug isn’t properly closed. The fix isn’t pretty. Pipe grips, steady pressure, make sure every pin is actually biting into the conductor. Caveman engineering. But it works. The temptation is always to replace the cable and move on. Takes longer, costs more, and half the time the new one has the same problem if you don’t know what you’re looking for. A proper crimp tool and a decent RJ45 plug would have avoided all of it.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/511/0*m_AsheE-Rjbx3jxv" /></figure><ul><li>Field Service</li><li>Fault Finding</li><li>Industrial Maintenance</li></ul><p><em>Originally published at </em><a href="https://www.findfst.com/life/looks-fine-no-comms"><em>https://www.findfst.com</em></a><em> on December 30, 2026.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=d08855945bd6" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Measure twice, cut once right… | FindFST]]></title>
            <link>https://medium.com/@nealjameswareing/measure-twice-cut-once-right-findfst-6db813a3b8b7?source=rss-80a5ca657d36------2</link>
            <guid isPermaLink="false">https://medium.com/p/6db813a3b8b7</guid>
            <category><![CDATA[field-service-technician]]></category>
            <category><![CDATA[electrical-cabling]]></category>
            <category><![CDATA[welding]]></category>
            <category><![CDATA[findfst]]></category>
            <category><![CDATA[industrial-engineering]]></category>
            <dc:creator><![CDATA[Neal Wareing]]></dc:creator>
            <pubDate>Mon, 26 Oct 2026 12:00:39 GMT</pubDate>
            <atom:updated>2026-10-27T10:00:27.994Z</atom:updated>
            <content:encoded><![CDATA[<p>Upgrade project in South Africa. Asked the lads to make a small hole for 6 cables. Short coffee break later, gaping hole. Factory is incredibly dusty. Cabinets need to be airtight. The lads spent the next 2 days cutting and welding. (work goes slow in SA). Next time I’ll draw the cut mark on the cabinet. What should have been a 30 minutes job turned into 2 days.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*Nxrkh3oQnqStokr5" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*UfRtwVtf38xNV_s_" /></figure><ul><li>Industrial Engineering</li><li>Welding</li><li>Electrical Cabling</li></ul><p><em>Originally published at </em><a href="https://www.findfst.com/life/measure-twice-cut-once-right"><em>https://www.findfst.com</em></a><em> on October 26, 2026.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=6db813a3b8b7" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Engineer vs technician. People use them interchangeably. They’re not the same thing. | FindFST]]></title>
            <link>https://medium.com/@nealjameswareing/engineer-vs-technician-people-use-them-interchangeably-theyre-not-the-same-thing-findfst-e0499cecf762?source=rss-80a5ca657d36------2</link>
            <guid isPermaLink="false">https://medium.com/p/e0499cecf762</guid>
            <category><![CDATA[industrial-maintenance]]></category>
            <category><![CDATA[field-service-technician]]></category>
            <category><![CDATA[field-service]]></category>
            <category><![CDATA[findfst]]></category>
            <dc:creator><![CDATA[Neal Wareing]]></dc:creator>
            <pubDate>Mon, 26 Oct 2026 12:00:29 GMT</pubDate>
            <atom:updated>2026-10-27T09:59:51.626Z</atom:updated>
            <content:encoded><![CDATA[<p>I saw an engineer stripping wire with a pair of scissors once. An engineer designs the system. A technician makes it work in the real world. I’ve worked alongside engineers who couldn’t read a wiring diagram under pressure. I’ve worked with technicians who could diagnose a fault faster than most people could find the manual. The title matters less than the capability. Job specs ask for a degree to do a job that needs hands and experience. You fault-find a servo drive with time served, not a qualification.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*P478gPq_wMe0Pk3L" /></figure><ul><li>FieldService</li><li>FieldServiceTechnician</li><li>IndustrialMaintenance</li></ul><p><em>Originally published at </em><a href="https://www.findfst.com/life/engineer-vs-technician-people-use-them-interchangeably-they-re-not-the-same-thing"><em>https://www.findfst.com</em></a><em> on October 26, 2026.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=e0499cecf762" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Machine down, no signals to the HMI, Profibus communication not working. | FindFST]]></title>
            <link>https://medium.com/@nealjameswareing/machine-down-no-signals-to-the-hmi-profibus-communication-not-working-findfst-72300734b0f1?source=rss-80a5ca657d36------2</link>
            <guid isPermaLink="false">https://medium.com/p/72300734b0f1</guid>
            <category><![CDATA[automation]]></category>
            <category><![CDATA[profibus]]></category>
            <category><![CDATA[field-service-technician]]></category>
            <category><![CDATA[findfst]]></category>
            <category><![CDATA[industrial-automation]]></category>
            <dc:creator><![CDATA[Neal Wareing]]></dc:creator>
            <pubDate>Sun, 25 Oct 2026 21:08:13 GMT</pubDate>
            <atom:updated>2026-10-27T09:56:32.942Z</atom:updated>
            <content:encoded><![CDATA[<p>First question I ask to the maintenance guys: “What work has been done?” Customer had replaced one of the motors… Changing a motor shouldn’t affect comms. Motor limit switch cover had been re installed and wire trapped in between the casing causing this short. Same 24V used for the WAGO modules (bad practice) making a short and the entire Profibus network to come down. First question always: what changed.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/714/0*gOPsuBaD3M4-o8ws" /></figure><ul><li>FieldServiceTechnician</li><li>Automation</li><li>Profibus</li><li>Industrial Automation</li></ul><p><em>Originally published at </em><a href="https://www.findfst.com/life/machine-down-no-signals-to-the-hmi-profibus-communication-not-working"><em>https://www.findfst.com</em></a><em> on November 5, 2026.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=72300734b0f1" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[The most qualified person isn’t always the best fault finder. | FindFST]]></title>
            <link>https://medium.com/@nealjameswareing/the-most-qualified-person-isnt-always-the-best-fault-finder-findfst-793a91e5acb1?source=rss-80a5ca657d36------2</link>
            <guid isPermaLink="false">https://medium.com/p/793a91e5acb1</guid>
            <category><![CDATA[field-service-technician]]></category>
            <category><![CDATA[maintenance]]></category>
            <category><![CDATA[industrial-engineering]]></category>
            <category><![CDATA[findfst]]></category>
            <dc:creator><![CDATA[Neal Wareing]]></dc:creator>
            <pubDate>Sun, 25 Oct 2026 12:00:42 GMT</pubDate>
            <atom:updated>2026-10-25T20:38:49.198Z</atom:updated>
            <content:encoded><![CDATA[<p>I’ve seen it both ways. The degree qualified engineer hits the checklist, finds nothing obvious, swaps parts, power-cycles. Fault’s back next week. The other type won’t walk away from a fault they haven’t found. They’ll pull the same connector three times. Come back after dinner and a cheeky beer. Sleep on it. Those are the ones who find: * The pin not quite seated. * The wire clamped on insulation instead of copper. * The intermittent contact that only drops under load. I know who I’d rather have on a breakdown.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*9fT3qJ6LHgj06UlF" /></figure><p><em>Originally published at </em><a href="https://www.findfst.com/life/the-most-qualified-person-isn-t-always-the-best-fault-finder"><em>https://www.findfst.com</em></a><em> on October 25, 2026.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=793a91e5acb1" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Rookie mistake that cost me a full day | FindFST]]></title>
            <link>https://medium.com/@nealjameswareing/rookie-mistake-that-cost-me-a-full-day-findfst-3e32e9ded8a0?source=rss-80a5ca657d36------2</link>
            <guid isPermaLink="false">https://medium.com/p/3e32e9ded8a0</guid>
            <category><![CDATA[findfst]]></category>
            <category><![CDATA[field-service-technician]]></category>
            <category><![CDATA[industrial-maintenance]]></category>
            <category><![CDATA[field-service]]></category>
            <category><![CDATA[fault-finding]]></category>
            <dc:creator><![CDATA[Neal Wareing]]></dc:creator>
            <pubDate>Sun, 25 Oct 2026 12:00:27 GMT</pubDate>
            <atom:updated>2026-10-27T09:58:56.777Z</atom:updated>
            <content:encoded><![CDATA[<p>First time I installed new cables, I did it as fast as possible. Get to the cabinet and all the plugs were damaged, cannot connect them. Spent the remainder of the day fiddling with a screw drive trying to re form the plugs. Spend an extra 10 minutes wrapping the sub-D plugs properly before running new cables. Save yourself hours of messing around trying to re form the plug later. It’s a mistake you make once but a sure way to tell if someone is experienced</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*Au088mB7-3WJlJ7n" /></figure><ul><li>Field Service</li><li>Industrial Maintenance</li><li>Fault Finding</li></ul><p><em>Originally published at </em><a href="https://www.findfst.com/life/rookie-mistake-that-cost-me-a-full-day"><em>https://www.findfst.com</em></a><em> on October 25, 2026.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=3e32e9ded8a0" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[12 years in field service, you pick up a few tricks. | FindFST]]></title>
            <link>https://medium.com/@nealjameswareing/12-years-in-field-service-you-pick-up-a-few-tricks-findfst-aae386f00556?source=rss-80a5ca657d36------2</link>
            <guid isPermaLink="false">https://medium.com/p/aae386f00556</guid>
            <category><![CDATA[fst-life]]></category>
            <category><![CDATA[troubleshooting]]></category>
            <category><![CDATA[field-service-technician]]></category>
            <category><![CDATA[industrial-maintenance]]></category>
            <category><![CDATA[findfst]]></category>
            <dc:creator><![CDATA[Neal Wareing]]></dc:creator>
            <pubDate>Sun, 25 Oct 2026 12:00:00 GMT</pubDate>
            <atom:updated>2026-10-25T20:28:20.476Z</atom:updated>
            <content:encoded><![CDATA[<p>Intermittent overspeed fault on a servo motor. Cycle the power, fault clears, runs fine for a few days, then it’s back. Drive replaced. Motor replaced. Wiring “checked”. When someone says they checked the wiring, it’s usually a visual check. Doesn’t catch this. My trick: run a long wire to the pin at the motor plug, continuity test from the far end, measure resistance on each wire individually. Should be around 1 ohm. Pink wire came back at 70 ohms. That’s not a wire fault, that’s a connection fault. Pin wasn’t properly seated in the plug. Faults like this get power-cycled away for years without ever getting fixed. The drive and motor were never the problem.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/787/0*xHgTg0z61mLVH8lc" /></figure><p><em>Originally published at </em><a href="https://www.findfst.com/life/12-years-in-field-service-you-pick-up-a-few-tricks"><em>https://www.findfst.com</em></a><em> on October 25, 2026.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=aae386f00556" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[More often than I can count, the long journey has ended with a straightforward fix. | FindFST]]></title>
            <link>https://medium.com/@nealjameswareing/more-often-than-i-can-count-the-long-journey-has-ended-with-a-straightforward-fix-findfst-a3bb17b9aed6?source=rss-80a5ca657d36------2</link>
            <guid isPermaLink="false">https://medium.com/p/a3bb17b9aed6</guid>
            <category><![CDATA[power-cycle]]></category>
            <category><![CDATA[field-service-technician]]></category>
            <category><![CDATA[fault-finding]]></category>
            <category><![CDATA[intermittent-faults]]></category>
            <category><![CDATA[findfst]]></category>
            <dc:creator><![CDATA[Neal Wareing]]></dc:creator>
            <pubDate>Sat, 24 Oct 2026 12:00:41 GMT</pubDate>
            <atom:updated>2026-10-25T20:45:05.489Z</atom:updated>
            <content:encoded><![CDATA[<p>This was one of them. Intermittent faults are the ones that get your brain working. No pattern, no error code, machine runs fine for days then stops without warning. Power cycle, back to normal. Repeat. When someone says it happens randomly, that’s the signal to look harder, not accept it. Attention to detail is what separates a proper diagnosis from a parts swap and a prayer. The photo says it all. Screws too long, plug not properly secured. The slightest vibration or movement interrupts the connection. Machine stops, customer power cycles, runs fine for another few days. Meanwhile the waste from every unplanned stop is quietly adding up. The fix took minutes. Finding it was the job.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/520/0*KVy6FMfdYyZWPo96" /></figure><p><em>Originally published at </em><a href="https://www.findfst.com/life/more-often-than-i-can-count-the-long-journey-has-ended-with-a-straightforward-fix"><em>https://www.findfst.com</em></a><em> on October 24, 2026.</em></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=a3bb17b9aed6" width="1" height="1" alt="">]]></content:encoded>