<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Toheeb Ogunshina on Medium]]></title>
        <description><![CDATA[Stories by Toheeb Ogunshina on Medium]]></description>
        <link>https://medium.com/@ogunshinatoheeb15?source=rss-e7d84c030437------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/0*HUoyk-GBEP1FVmne.jpg</url>
            <title>Stories by Toheeb Ogunshina on Medium</title>
            <link>https://medium.com/@ogunshinatoheeb15?source=rss-e7d84c030437------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Tue, 24 Nov 2026 15:36:43 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@ogunshinatoheeb15/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Solar Energy System Upgrade: From Tubular Batteries to a 30kWh Lithium-Ion Storage System]]></title>
            <link>https://medium.com/@ogunshinatoheeb15/solar-energy-system-upgrade-from-tubular-batteries-to-a-30kwh-lithium-ion-storage-system-2118d85e2f0e?source=rss-e7d84c030437------2</link>
            <guid isPermaLink="false">https://medium.com/p/2118d85e2f0e</guid>
            <category><![CDATA[10kw-inverter-system]]></category>
            <category><![CDATA[project-management]]></category>
            <category><![CDATA[30kwh-lithium-bat-setup]]></category>
            <category><![CDATA[renewable-energy-projects]]></category>
            <category><![CDATA[operations-management]]></category>
            <dc:creator><![CDATA[Toheeb Ogunshina]]></dc:creator>
            <pubDate>Wed, 09 Sep 2026 11:21:27 GMT</pubDate>
            <atom:updated>2026-09-09T11:21:27.853Z</atom:updated>
            <content:encoded><![CDATA[<h3>Project Overview</h3><p>As part of a solar energy system upgrade project, I was involved in the transformation of an existing backup power system consisting of a <strong>5kVA inverter and 12 tubular batteries</strong> into a more efficient and scalable hybrid solar power system.</p><p>The existing system relied on multiple tubular batteries, which required regular maintenance and had limitations in terms of usable energy capacity, charging efficiency, depth of discharge, and long-term operational reliability.</p><p>The objective of the upgrade was to improve the system’s <strong>energy storage capacity, operational efficiency, reliability, and scalability</strong>, while reducing the maintenance requirements associated with the existing battery technology.</p><p>The upgraded system consisted of:</p><ul><li><strong>2 × 5kW Solis inverters connected in parallel</strong></li><li><strong>30kWh lithium-ion battery storage</strong></li><li><strong>24 × 500W solar panels</strong></li><li>Total PV capacity: <strong>12kWp</strong></li><li>Replacement of the existing 5kVA inverter and 12 tubular batteries</li><li>Integrated solar generation, battery storage, and backup power management</li></ul><h3>The Challenge</h3><p>The original system was based on a 5kVA inverter supported by 12 tubular batteries. Although the system provided backup power, the configuration presented several operational challenges.</p><p>The tubular battery bank required proper maintenance and battery management, while its usable capacity was limited by the recommended depth of discharge. Battery performance could also deteriorate over time, affecting backup duration and overall system reliability.</p><p>From an operations perspective, the system also had limited scalability. Increasing the available power capacity or improving the backup duration would require significant modifications to the existing configuration.</p><p>The project therefore required a solution that could provide:</p><ul><li>Higher usable energy storage</li><li>Improved battery efficiency</li><li>Better backup performance</li><li>Reduced battery maintenance</li><li>Increased inverter capacity</li><li>Improved solar generation</li><li>Greater system scalability</li><li>Better monitoring and operational control</li></ul><h3>Project Planning and System Design</h3><p>The first stage involved assessing the existing system and determining the requirements of the upgraded system.</p><p>Rather than simply replacing the batteries, the project was approached as a complete system upgrade. This involved evaluating the expected load, available installation space, solar generation potential, battery capacity, inverter requirements, protection requirements, cabling, and system compatibility.</p><p>The proposed architecture used <strong>two 5kW Solis inverters operating in parallel</strong>, providing a combined inverter capacity of approximately <strong>10kW</strong>.</p><p>The solar array consisted of <strong>24 × 500W panels</strong>, providing:</p><p><strong>24 × 500W = 12,000W = 12kWp</strong></p><p>This provided sufficient PV capacity to support battery charging while also supplying loads during periods of solar generation.</p><p>The energy storage system was upgraded to a <strong>30kWh lithium-ion battery bank</strong>, providing significantly greater usable energy compared with the previous tubular battery configuration.</p><h3>Battery Technology Upgrade</h3><p>One of the key decisions in the project was replacing the tubular battery bank with lithium-ion storage.</p><p>Lithium-ion technology offered several operational advantages for this application, including:</p><ul><li>Higher usable depth of discharge</li><li>Better charging and discharging efficiency</li><li>Reduced routine maintenance</li><li>Longer expected service life when properly operated</li><li>Better monitoring through battery management systems</li><li>More compact energy storage</li><li>Improved suitability for repeated daily cycling</li></ul><p>The upgrade therefore shifted the system from a traditional lead-acid-based storage approach to a more modern energy-storage architecture.</p><h3>Inverter Upgrade</h3><p>The existing <strong>5kVA inverter</strong> was replaced with <strong>two 5kW Solis inverters connected in parallel</strong>.</p><p>This increased the available inverter capacity to approximately <strong>10kW</strong>, allowing the system to support a larger load profile and providing greater flexibility for future expansion.</p><p>Operating the inverters in parallel also provided a more scalable architecture compared with the previous single-inverter configuration.</p><p>The inverter configuration was coordinated with the lithium battery system and PV array to ensure appropriate power flow between:</p><p><strong>Solar PV → Loads → Battery → Grid/Backup Source</strong></p><p>The system was configured to prioritize available solar energy while using battery storage and other available power sources according to the operational requirements.</p><h3>Solar PV Expansion</h3><p>The upgraded system incorporated <strong>24 × 500W solar modules</strong>, giving a total installed PV capacity of <strong>12kWp</strong>.</p><p>The larger PV array increased the system’s ability to generate energy during daylight hours and recharge the lithium battery bank.</p><p>From an operational perspective, the PV capacity was considered alongside the battery storage capacity rather than treating the solar array and battery as separate components.</p><p>This helped ensure that the system could effectively utilize available solar energy while maintaining sufficient energy storage for periods of low or zero solar generation.</p><h3>Operations &amp; Supply Chain Management</h3><p>A significant part of the project involved coordinating the resources required to execute the upgrade.</p><p>The project required planning around:</p><h3>1. Procurement</h3><p>Key components and materials were identified and coordinated, including:</p><ul><li>Solis inverters</li><li>30kWh lithium battery</li><li>500W solar panels</li><li>DC and AC protection devices</li><li>Cables and connectors</li><li>Mounting and installation materials</li><li>Communication and monitoring accessories</li></ul><p>Procurement planning was important to ensure that critical materials were available before installation commenced.</p><h3>2. Logistics</h3><p>The movement and handling of the equipment were coordinated based on the installation schedule.</p><p>Special attention was given to the handling of lithium batteries and electrical equipment to minimize the risk of damage during transportation and installation.</p><h3>3. Installation Coordination</h3><p>The installation process required coordination between technicians and other project stakeholders.</p><p>Activities included:</p><ul><li>Decommissioning the existing battery/inverter arrangement</li><li>Preparing the new installation</li><li>Installing the lithium battery system</li><li>Installing and configuring the Solis inverters</li><li>Installing the PV modules</li><li>Connecting the DC and AC systems</li><li>Installing protection equipment</li><li>Establishing inverter communication</li><li>Testing and commissioning</li></ul><h3>4. Quality Control</h3><p>Quality checks were carried out throughout the installation process to ensure that equipment, connections, configuration, and system operation met the project requirements.</p><p>Particular attention was given to polarity, cable sizing, protection, battery connections, inverter configuration, communication, and system commissioning.</p><h3>Commissioning and Performance Monitoring</h3><p>Following installation, the system was commissioned to verify the performance of the major components.</p><p>The commissioning process included:</p><ul><li>PV voltage verification</li><li>Battery voltage and state-of-charge verification</li><li>Inverter startup and configuration</li><li>Load testing</li><li>Battery charging and discharging tests</li><li>Parallel inverter operation testing</li><li>Protection-device verification</li><li>Communication and monitoring checks</li><li>Verification of power transfer between PV, battery, load, and backup sources</li></ul><p>The system was subsequently monitored to evaluate its operational performance and identify any configuration adjustments required.</p><h3>Project Outcome</h3><p>The upgrade transformed the existing <strong>5kVA tubular-battery backup system</strong> into a significantly larger and more modern energy-storage solution.</p><h3>Before</h3><p><strong>5kVA inverter + 12 tubular batteries</strong></p><h3>After</h3><p><strong>2 × 5kW Solis inverters + 30kWh lithium-ion battery + 12kWp solar PV</strong></p><p>The upgraded system provided:</p><ul><li>Increased inverter capacity from approximately 5kVA to 10kW</li><li>Increased energy storage capability</li><li>Greater usable battery capacity</li><li>Improved solar generation capacity</li><li>Reduced battery maintenance requirements</li><li>Improved system scalability</li><li>Better monitoring and control</li><li>A more modern and efficient energy-storage architecture</li></ul><h3>Key Operations &amp; Supply Chain Lessons</h3><p>This project reinforced the importance of viewing technical infrastructure projects from both an <strong>engineering and operational perspective</strong>.</p><p>Successful delivery required more than selecting the right equipment. It required effective coordination of:</p><p><strong>Planning → Procurement → Logistics → Installation → Quality Control → Commissioning → Monitoring</strong></p><p>A technically sound system can still fail to deliver its expected value if equipment arrives late, components are incompatible, installation is poorly coordinated, or commissioning is not properly executed.</p><p>For me, the project demonstrated how effective operations management can directly influence the reliability, cost, efficiency, and long-term performance of an energy infrastructure project.</p><h3>Conclusion</h3><p>The upgrade from a 5kVA inverter and tubular battery system to a <strong>10kW parallel Solis inverter configuration with 30kWh lithium-ion storage and 12kWp solar PV</strong> represented a significant improvement in the system’s overall capability.</p><p>Beyond the technical upgrade, the project provided valuable experience in <strong>project planning, procurement coordination, resource management, installation supervision, quality assurance, commissioning, and post-installation monitoring</strong>.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/810/1*ITakXYpZtC6QGgh5McXA_A.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/810/1*nUzdYG967w1xxM4KLPz17w.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*umKnfIru8tiMCg3p_IeR6Q.jpeg" /><figcaption><strong>A PICTURE OF THE OLD 12 TUBULAR BATTERY AND THE 5KVA INVERTER</strong></figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/607/1*VoL203vww3yNBa1yglnzRA.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/607/1*pVP5DstVrhmD_GwKEgQT-w.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/607/1*xJRcBuKWiy7lisw6fMkRNw.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/607/1*nP5v0cQxo5bSYMw3lviAPA.jpeg" /><figcaption><strong>PROCUREMENT AND LOGISTICS PROCESS OF THE NEW SYSTEM</strong></figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/810/1*dQVKfs7T-XVxKYMWOXvsow.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/607/1*_WbEb4vFVI-wR8_6cQvsFg.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/810/1*2RAiUMn_CzNKOIwNFsypOA.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*FyWBykGRjhoPmbKDbLhfXw.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/810/1*-j2xqi_UpnxzTyzHtk52rA.jpeg" /><figcaption><strong>INSTALLATION PROCESS OF THE NEW SYSTEM</strong></figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/810/1*_umRHwl_YvhnernUom6CzQ.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/810/1*CBVbC3fnzPWYXyGVOA6lMQ.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/810/1*6mz19xR2Fp1zJKX--0FyIA.jpeg" /><figcaption><strong>THE PICTURE OF THE NEW SYSTEM INSTALLATION</strong></figcaption></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=2118d85e2f0e" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>