<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Rahul Rolen on Medium]]></title>
        <description><![CDATA[Stories by Rahul Rolen on Medium]]></description>
        <link>https://medium.com/@rahulrolen?source=rss-16ed799e49a7------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/0*6VKkRMNb1K9j0N6w</url>
            <title>Stories by Rahul Rolen on Medium</title>
            <link>https://medium.com/@rahulrolen?source=rss-16ed799e49a7------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Sun, 29 Nov 2026 08:59:14 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@rahulrolen/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[The components of an HVAC system fall into four working groups: controls, cooling, heating and air…]]></title>
            <link>https://medium.com/@rahulrolen/the-components-of-an-hvac-system-fall-into-four-working-groups-controls-cooling-heating-and-air-89dbf683b229?source=rss-16ed799e49a7------2</link>
            <guid isPermaLink="false">https://medium.com/p/89dbf683b229</guid>
            <category><![CDATA[components-of-an-hvac]]></category>
            <category><![CDATA[hvac-system]]></category>
            <dc:creator><![CDATA[Rahul Rolen]]></dc:creator>
            <pubDate>Tue, 17 Nov 2026 13:32:52 GMT</pubDate>
            <atom:updated>2026-11-17T13:32:52.696Z</atom:updated>
            <content:encoded><![CDATA[<h3>The components of an HVAC system fall into four working groups: controls, cooling, heating and air distribution. Knowing which group a part belongs to makes troubleshooting and system selection easier.</h3><h3># Controls</h3><h4>Thermostat</h4><p>The thermostat reads space temperature and tells the equipment when to start or stop.</p><h3>Cooling Components</h3><h4>Compressor</h4><p>The compressor circulates refrigerant and raises its pressure and temperature. In a split system it is the largest electrical load.</p><h4>Condenser Coil</h4><p>Located in the outdoor unit, the condenser coil rejects the heat absorbed indoors, plus compressor heat, to the outside air.</p><h4>Metering Device</h4><p>A thermostatic expansion valve or fixed orifice drops refrigerant pressure and controls how much enters the evaporator.</p><h4>Evaporator Coil</h4><p>Refrigerant absorbs indoor heat here. Moisture also condenses on the coil, dehumidifying the air.</p><h4>Refrigerant</h4><p>Refrigerant is the working fluid that carries heat between the coils. The correct type and charge come from the manufacturer.</p><h3>Heating Components</h3><h4>Furnace and Heat Exchanger</h4><p>A gas furnace passes hot combustion gases through a heat exchanger while indoor air flows over its outside surface, keeping combustion gases separate from supply air. A cracked heat exchanger is a safety issue, so inspect it. Heat pumps and electric strips are alternatives.</p><h3><strong>Air Distribution Components</strong></h3><h4><strong>Blower</strong></h4><p>The blower moves air across the coil or heat exchanger and through the ducts, and it must match the duct system’s static pressure.</p><h4><strong>Ductwork</strong></h4><p>Supply and return ducts deliver and recover air. Sizing, leakage and layout affect airflow, noise and comfort. Good equipment on poor ductwork often causes complaints.</p><h4><strong>Filters</strong></h4><p>Filters protect the coil and blower. A dirty filter restricts airflow, which can contribute to a frozen evaporator coil and higher energy use.</p><h3><strong>How the Parts Work Together</strong></h3><p>On a cooling call, the thermostat starts the blower and compressor. Refrigerant absorbs heat at the evaporator and rejects it outdoors at the condenser, while the blower circulates cooled air. On a heating call, the furnace or heat pump takes over the same airflow path.</p><h4><strong>Practical Recommendation</strong></h4><p>When diagnosing a comfort complaint, my recommendation is to check airflow before suspecting refrigerant. Start with the filter, blower and ducts, because restricted airflow can mimic a refrigerant problem.</p><p>Commercial buildings add chillers, cooling towers and VAV boxes, but the components of an HVAC system follow the same logic: something makes heating or cooling, something moves it, and controls decide when.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=89dbf683b229" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>