<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Sauna Dekor Spa Solutions on Medium]]></title>
        <description><![CDATA[Stories by Sauna Dekor Spa Solutions on Medium]]></description>
        <link>https://medium.com/@saunadekorspasolutions?source=rss-9a831ade41ce------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/1*tQ02CREyGradjKe5f6igaA.png</url>
            <title>Stories by Sauna Dekor Spa Solutions on Medium</title>
            <link>https://medium.com/@saunadekorspasolutions?source=rss-9a831ade41ce------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Thu, 19 Nov 2026 16:00:37 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@saunadekorspasolutions/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Spa Commissioning in Riyadh: Who Should Witness the Tests]]></title>
            <link>https://medium.com/@saunadekorspasolutions/spa-commissioning-in-riyadh-who-should-witness-the-tests-6caae545c928?source=rss-9a831ade41ce------2</link>
            <guid isPermaLink="false">https://medium.com/p/6caae545c928</guid>
            <category><![CDATA[construction]]></category>
            <category><![CDATA[architecture]]></category>
            <dc:creator><![CDATA[Sauna Dekor Spa Solutions]]></dc:creator>
            <pubDate>Thu, 19 Nov 2026 14:46:01 GMT</pubDate>
            <atom:updated>2026-11-19T14:46:01.776Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="Mosaic steam room with a lit bench and recessed ceiling lights in a villa in Riyadh" src="https://cdn-images-1.medium.com/max/881/1*INTmWzQJmNDC-ByQTbQ3iw.jpeg" /></figure><p><em>Updated: 19 November 2026</em></p><p><strong>Short answer:</strong> At Sauna Dekor Spa Solutions we commission a Riyadh spa in front of four people: the MEP consultant or site engineer, the person who will run the spa every day, the hotel or villa maintenance lead, and the installer’s technician. Each of them watches a different part of the test and signs a different line. If one of them is missing, the handover is still possible, but a question will come back weeks later with nobody who saw the answer.</p><h3>Why does the witness list matter more than the test sheet?</h3><p>A test sheet can be copied from any project. The value of commissioning is that the right people saw the numbers with their own eyes on the day the rooms first ran at full load. In Riyadh hotel and villa projects we often see the opposite: the contractor runs the sauna in the morning, the consultant arrives after lunch, and the spa manager is hired a month later. The paper says “tested”, but no one who will live with the room was there.</p><p>We plan the commissioning day with the witness list first and the test sequence second. The questions on our <a href="https://saunadekor.com/riyadh/">Riyadh spa projects page</a> start the same way: who is the operator, and who signs for the building.</p><h3>Who stands in the room, and what does each person watch?</h3><ul><li><strong>MEP consultant or site engineer</strong> — supply, isolation, earthing, drain flow, ventilation · electrical and mechanical lines</li><li><strong>Spa manager or future operator</strong> — heat-up, setpoints, control panel, cleaning access · operating lines and training record</li><li><strong>Hotel or villa maintenance lead</strong> — generator room, valves, filters, spare-part list · plant room and service access lines</li><li><strong>Installer’s technician</strong> — the full sequence and every reading · the test record as a whole</li></ul><p>On larger hotel projects a fifth person often joins: the steam generator or heater manufacturer’s local representative. That is useful when the equipment warranty asks for a registered start-up, but it does not replace the operator.</p><h3>Which tests should they see running, not just read about?</h3><p>Some checks can be recorded on paper. Others only mean something when the room is working:</p><ul><li><strong>Sauna heat-up.</strong> An electric Finnish sauna heats up in about 1 hour, following the manufacturer’s guidance, and should reach its setpoint inside the normal 80–100 °C range. The operator should see the panel, the sensor position and the time it took.</li><li><strong>First heating smell.</strong> An electric heater must never run without its stones, and the smell at first heating comes from the heater and the stones. Explaining this on the day prevents a worried call the next morning.</li><li><strong>Steam room at working condition.</strong> The room should reach 40–50 °C at close to 100 % relative humidity. Witnesses check that condensate runs to the drain and the steam outlet is shielded.</li><li><strong>Safety cut-outs.</strong> Over-temperature limiter, door contact if fitted, emergency stop and the timer. Each one is tripped once while everyone watches.</li><li><strong>Drains and floor fall.</strong> Water is run until the gullies have taken a full flow. Puddles found on the day are fixed before signing.</li></ul><h3>What should the operator take away from the day?</h3><p>The spa manager does not need wiring diagrams. They need to leave knowing three things: how to start and stop each room, which reading on the panel means “call someone”, and who that someone is. We ask the operator to run one heat-up cycle by hand while the technician watches, not the other way round.</p><p>The maintenance lead takes the plant room side: where the isolators are, how the steam generator is drained, and which parts we keep in stock in Istanbul for the equipment we install.</p><h3>When is the day not ready to be signed?</h3><p>We postpone the signature, not the test, when one of these is open: a room did not reach its setpoint, a safety device did not trip, a drain held water, or the operator was absent. Writing “open item” next to a line is better than a clean sheet that hides it. The warranty clock is a good reason for honesty here: our contracts carry a 24-month warranty on workmanship and manufacturing, a 24-month manufacturer’s warranty on electrical and mechanical equipment, and a 5-year warranty on structure and waterproofing, and all of them start from a handover that should reflect the real state of the rooms.</p><p>For larger hotel projects, the full scope of what we deliver is on our <a href="https://saunadekor.com/hotel-spa-design/">hotel spa design page</a>.</p><h3>FAQ</h3><h3>Can commissioning be done remotely by video?</h3><p>Parts of it can be watched on video, such as the panel display during heat-up. Safety cut-outs, drains and steam distribution need someone in the room, because the camera does not show what a hand on a wall or a foot in a gully shows.</p><h3>Does the operator have to be hired before commissioning?</h3><p>It helps. If the operator is not yet in place, we recommend a second, shorter session on the day the spa team starts, using the same test sheet.</p><h3>Who keeps the signed test record?</h3><p>The building owner keeps the original. The operator and the maintenance team each keep a copy, and we keep one with the project file.</p><h3>Further reading</h3><ul><li><a href="https://en.wikipedia.org/wiki/Building_commissioning">Building commissioning (Wikipedia)</a></li><li><a href="https://en.wikipedia.org/wiki/Sauna">Sauna (Wikipedia)</a></li><li><a href="https://en.wikipedia.org/wiki/Residual-current_device">Residual-current device (Wikipedia)</a></li></ul><p><strong>About the author.</strong> <a href="https://saunadekor.com/products/">Sauna Dekor Spa Solutions</a> · sauna, steam room, hammam and pool manufacturer since 1987, now in our 40th year · manufacturing in Istanbul, team of 19 · TS EN ISO 9001:2015 · 5,000+ projects in 41+ countries.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=6caae545c928" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Şok kovası: çizimde olması gerekenler]]></title>
            <link>https://medium.com/@saunadekorspasolutions/%C5%9Fok-kovas%C4%B1-%C3%A7izimde-olmas%C4%B1-gerekenler-ca680f62c7ee?source=rss-9a831ade41ce------2</link>
            <guid isPermaLink="false">https://medium.com/p/ca680f62c7ee</guid>
            <category><![CDATA[mimarlık]]></category>
            <category><![CDATA[interior-design]]></category>
            <dc:creator><![CDATA[Sauna Dekor Spa Solutions]]></dc:creator>
            <pubDate>Thu, 19 Nov 2026 11:31:02 GMT</pubDate>
            <atom:updated>2026-11-19T11:31:02.252Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="Siyah ve gümüş şerit mozaikli duş hücresinde tavana yakın braketle asılı metal çemberli ahşap şok kovası ve çekme ipi" src="https://cdn-images-1.medium.com/max/1024/1*Dns4LcmSQSzK3--RbTjZRQ.jpeg" /></figure><p><em>Güncelleme: 19 Kasım 2026</em></p><p><strong>Kısa cevap:</strong> şok kovası küçük bir ekipman, ama çizim setinde altı paftada yer alması gerekir: planda kovanın yeri ve kapı açılma alanı, kesitte duvar yapısı ile ankraj ve ipin ucu, elektrikte varsa aydınlatma ve vana beslemesi, su ve gider paftasında soğuk hat ile kovanın altındaki gider, havalandırmada hücrenin egzozu, bitiş paftasında yalıtım geçişleri. Sauna Dekor Spa Solutions kovayı siparişe almadan önce bu altı noktayı çizim üzerinde kontrol ediyor.</p><p>Kova her çekişte içindeki suyun tamamını bir anda boşaltır ve dolu hâliyle duvara ağırlık bindirir. Çizimde bu iki gerçeğin karşılığı yoksa sahada sorun çıkar.</p><h3>Planda ne görünmeli?</h3><p><strong>Çizimde:</strong> kovanın duvardaki ya da tavandaki yeri, kullanıcının durduğu alan, sauna veya buhar odası kapısının açılma yayı, yandaki duş ya da buz çeşmesi gibi komşu öğeler ve kovanın sökülüp temizlenebileceği boşluk.</p><p><strong>Eksikse sahada ne olur:</strong> kova kapının önüne denk gelir, açılan kapı ipe takılır, kova yanındaki duşla aynı noktaya su döker.</p><h3>Kesitte ne görünmeli?</h3><p><strong>Çizimde:</strong> kovanın asılacağı duvarın yapısı (beton, tuğla, gazbeton ya da levha), levha duvarsa arkadaki taşıyıcı profil veya plaka, braket yüksekliği, ipin ucunun yerden yüksekliği ve kovanın üstünde kalan tavan boşluğu.</p><p><strong>Eksikse sahada ne olur:</strong> braket alçı levhaya sıradan dübelle asılır, kova zamanla öne eğilir; ip kısa boylu kullanıcıya yetişmez.</p><h3>Elektrik paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> klasik ipli kova elektrik istemez. Kovanın üstünde ya da çevresinde aydınlatma varsa ıslak hacme uygun armatür, sürücülerin ıslak alanın dışındaki yeri ve kaçak akım koruması gösterilir. Otomatik dolumlu ya da zamanlayıcılı bir modelde selenoid vananın beslemesi de bu paftadadır.</p><p><strong>Eksikse sahada ne olur:</strong> armatür sürücüsü suyun ulaştığı tavana konur, kısa sürede arızalanır.</p><h3>Su ve gider paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> kova için ayrı soğuk su hattı, erişilebilir kesme vanası, şamandıralı dolum vanasının yeri, hat basıncı yüksekse basınç düşürücü, kovanın tam altında gider ve zeminin gidere doğru eğimi.</p><p><strong>Eksikse sahada ne olur:</strong> kova sıcak su ile karışan hatta bağlanır ya da taşar; boşalan su gidere değil koridora gider.</p><h3>Havalandırma paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> kovanın bulunduğu duş hücresinde ya da soğuk alanda egzoz noktası ve kanalın çıkış yolu.</p><p><strong>Eksikse sahada ne olur:</strong> sıcak odadan çıkan kullanıcıların getirdiği nem dar hücrede kalır, tavanda yoğuşma ve lekeler başlar.</p><h3>Bitiş ve detay paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> su yalıtımı katmanları, braket vidalarının yalıtımı geçtiği noktaların sızdırmazlık detayı, gider çevresinde yalıtım bandı ve kaplama derzi.</p><p><strong>Eksikse sahada ne olur:</strong> braket seramik bittikten sonra delinerek takılır, delikler kapatılmaz, duvarın arkasında nem görülür.</p><h3>Pafta kontrol tablosu</h3><ul><li><strong>Plan</strong> — Kova yeri, kullanıcı alanı, kapı yayı, komşu öğeler · Mimar, bizim ölçülerimizle</li><li><strong>Kesit</strong> — Duvar yapısı, ankraj, braket ve ip yüksekliği · Mimar ve biz</li><li><strong>Elektrik</strong> — Aydınlatma, sürücü yeri, varsa vana beslemesi · Elektrik mühendisi</li><li><strong>Su ve gider</strong> — Soğuk hat, kesme vanası, dolum vanası, gider, eğim · Mekanik tesisat mühendisi</li><li><strong>Havalandırma</strong> — Hücrenin egzozu, kanal yolu · Mekanik tesisat mühendisi</li><li><strong>Bitiş ve detay</strong> — Yalıtım geçişleri, sızdırmazlık, derz · Mimar ve biz</li></ul><p>Kova tipleri ve montaj seçenekleri <a href="https://www.saunadekor.com.tr/sok-kovasi/">şok kovası</a> sayfamızda.</p><h3>Sıkça sorulan sorular</h3><h3>Şok kovası için ayrı bir pafta çizilir mi?</h3><p>Genellikle gerekmez. Kova, ıslak alanın mevcut paftalarına işlenir; önemli olan altı paftanın hiçbirinde atlanmamasıdır.</p><h3>Kova tavana asılırsa çizim değişir mi?</h3><p>Evet. Bu durumda kesitte tavan taşıyıcısı ve ankraj detayı gösterilir, kovanın üstündeki boşluk yeniden kontrol edilir.</p><h3>Kovanın ölçülerini kim verir?</h3><p>Biz veriyoruz. Kova hacmi, braket ölçüsü ve ağırlık bilgisi mimara ve tesisat mühendisine çizimden önce gönderilir.</p><h3>Garanti nasıl işliyor?</h3><p>Her projede 24 ay işçilik ve imalat garantisi, elektrik ve mekanik ekipmanda 24 ay üretici garantisi, yapı ve su yalıtımında 5 yıl garanti veriyoruz.</p><h3>Kontrol için hangi çizimler yeterli?</h3><p>Islak alanın planı, kovanın asılacağı duvardan geçen kesit ve tesisat taslağı ilk kontrol için yeterli.</p><h3>Kaynaklar</h3><ul><li><a href="https://tr.wikipedia.org/wiki/Sauna">Vikipedi: Sauna</a></li><li><a href="https://tr.wikipedia.org/wiki/Su_yal%C4%B1t%C4%B1m%C4%B1">Vikipedi: Su yalıtımı</a></li><li><a href="https://en.wikipedia.org/wiki/Ballcock">Ballcock, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Residual-current_device">Residual-current device, Wikipedia</a></li></ul><p><strong>Yazar hakkında.</strong> <a href="https://www.saunadekor.com.tr/urunler/">Sauna Dekor Spa Solutions</a> · 1987&#39;den beri sauna, hamam, buhar odası ve havuz üreticisi · İstanbul’da üretimde 40. yılımızdayız, 19 çalışan · TS EN ISO 9001:2015 · 41+ ülkede 5.000+ proje, 577+ otel ve resort projesi · 32 ülke ve bölgede 732 kayıtlı referans.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=ca680f62c7ee" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Dinlenme odası: çizimde olması gerekenler]]></title>
            <link>https://medium.com/@saunadekorspasolutions/dinlenme-odas%C4%B1-%C3%A7izimde-olmas%C4%B1-gerekenler-c2e32d2f1142?source=rss-9a831ade41ce------2</link>
            <guid isPermaLink="false">https://medium.com/p/c2e32d2f1142</guid>
            <category><![CDATA[mimarlık]]></category>
            <category><![CDATA[interior-design]]></category>
            <dc:creator><![CDATA[Sauna Dekor Spa Solutions]]></dc:creator>
            <pubDate>Thu, 19 Nov 2026 05:52:20 GMT</pubDate>
            <atom:updated>2026-11-19T05:52:20.619Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="Kapalı havuzun yanında minderli ahşap şezlonglar, geometrik desenli cam cephe ve kademeli aydınlatmalı asma tavan" src="https://cdn-images-1.medium.com/max/1024/1*D-fK_rE820jWv_S7etZXMQ.jpeg" /></figure><p><em>Güncelleme: 19 Kasım 2026</em></p><p><strong>Kısa cevap:</strong> dinlenme odasının çizim seti altı paftada eksiksiz olmalı: plan (yatak sayısı, ıslak taraftan kuru tarafa akış, su istasyonu), kesit (akustik tavan, ıslak hacme komşu duvar), elektrik ve aydınlatma (dolaylı ışık devreleri, ısıtmalı yatak hatları), su ve gider (içme suyu noktası, ıslak girişte zemin eğimi), havalandırma ve iklim (nemli hacimlerden gelen hava) ve bitiş detayı (zemin, tekstil, yüzey). Sauna Dekor Spa Solutions dinlenme odasını termal yolculuğun son durağı olarak çizer; oda, önündeki sauna, hamam ve buhar odasıyla birlikte düşünülür.</p><p>Yatak sayısı sabit değildir. İşletmenin terapi hacimlerinin aynı anda kaç kişiye hizmet verdiğine göre çıkar; çizim de bu sayıyla başlar.</p><h3>Planda ne görünmeli?</h3><p><strong>Çizimde:</strong> yatak ve şezlongların sayısı ve dizilişi, aralarındaki geçiş, odaya hangi kapıdan ıslak ayakla girilip hangi yöne kuru olarak çıkıldığı, su ve çay istasyonunun yeri, havlu dönüş noktası. Havuz holüne açık bir dinlenme alanıysa ıslak yürüyüş yolu ile yatak alanı arasındaki sınır çizilir.</p><p><strong>Eksikse sahada ne olur:</strong> ıslak ayak yatakların arasından geçer, zemin sürekli silinir. Su istasyonu sonradan bir köşeye konur, kuyruk yatakların önünde birikir.</p><h3>Kesitte ne görünmeli?</h3><p><strong>Çizimde:</strong> akustik tavanın türü ve yüksekliği, tavan boşluğunda geçen kanallar, ıslak hacme komşu duvarda buhar kesici katman, kapıların conta ve eşik detayı. Duvarın döşemeden tavan döşemesine kadar çıktığı gösterilir.</p><p><strong>Eksikse sahada ne olur:</strong> sert tavan sesi yansıtır, fısıltı bile odaya yayılır. Hamam ya da buhar odasıyla ortak duvar terler, boya kabarır.</p><ul><li><strong>Plan</strong> — yatak sayısı, ıslak-kuru akış, su istasyonu, havlu noktası · mimar ve spa tasarımcısı</li><li><strong>Kesit</strong> — akustik tavan, buhar kesici, kapı detayı · mimar</li><li><strong>Elektrik ve aydınlatma</strong> — dolaylı ışık devreleri, kısma, yatak hatları · elektrik mühendisi</li><li><strong>Su ve gider</strong> — içme suyu noktası, ıslak girişte süzgeç ve eğim · mekanik mühendisi</li><li><strong>Havalandırma ve iklim</strong> — menfez yerleri, nemli hacimlerden ayrım · mekanik mühendisi</li><li><strong>Bitiş ve detay</strong> — kaymaz zemin, silinebilir yüzey, tekstil · iç mimar ve imalatçı</li></ul><h3>Elektrik ve aydınlatma paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> en az iki aydınlatma devresi (dinlenme için dolaylı, temizlik için genel ışık), kısma kumandasının yeri, ısıtmalı yatak varsa her biri için ayrı hat, su istasyonu ve varsa müzik sistemi için prizler. Yatak başında doğrudan göze gelen armatür olmadığı tavan planında görülür.</p><p><strong>Eksikse sahada ne olur:</strong> oda tek devreyle ya karanlık ya parlak kalır, ısıtmalı yataklar ortak hatta bağlanır ve sigorta atar.</p><h3>Su ve gider paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> su istasyonunun temiz su girişi ve gideri, ıslak tarafa bakan girişte yer süzgeci ve zeminin süzgece eğimi, havuz kenarındaki şezlong alanının havuzdan uzağa doğru eğimi.</p><p><strong>Eksikse sahada ne olur:</strong> su istasyonu damacanayla çözülür, girişte su göllenir, şezlongların altında nem kalır.</p><h3>Havalandırma ve iklim paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> taze hava ve emiş menfezlerinin yatağa göre yeri, nemli hacimlerin havasının dinlenme odasına taşınmadığı basınç düzeni, odanın kendi iklim kumandası. Termal hacimlerden çıkan terli beden üşümemeli, oda da bunaltmamalı.</p><p><strong>Eksikse sahada ne olur:</strong> menfez şezlonga üfler, havuz holünün nemli havası dinlenme odasına dolar, tekstiller kurumaz.</p><h3>Bitiş ve detay paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> ıslak ayağa uygun kaymaz zemin, silinebilir ve suya dayanıklı yatak yüzeyi, tekstillerin değiştirilebildiği detay, duvar ve tavanda ses yutan yüzeylerin yeri.</p><p><strong>Eksikse sahada ne olur:</strong> parlak zemin kayganlaşır, kumaş döşeme nem tutar, oda yankılanır.</p><p>Dinlenme odasının kaplamasını, tavanını ve tesisat altyapısını spa programının parçası olarak kuruyoruz. Ayrıntılar <a href="https://www.saunadekor.com.tr/dinlenme-odasi/">dinlenme odası</a> sayfamızda. Her projede işçilik ve imalatta 24 ay, elektrikli ve mekanik ekipmanlarda 24 ay üretici garantisi, taşıyıcı yapı ve su yalıtımında 5 yıl garanti verilir.</p><h3>Sıkça sorulan sorular</h3><h3>Dinlenme odasına kaç yatak konur?</h3><p>Sabit sayı yok. İşletmenin sauna, hamam ve buhar odasının aynı anda kaç kişiye hizmet verdiğine bakılarak hesaplanır.</p><h3>Dinlenme odası havuz holüne açık olabilir mi?</h3><p>Olabilir, ama ıslak yürüyüş yolu ile yatak alanının sınırı planda çizilir ve havuzun nemli havası iklim paftasında ayrıca ele alınır.</p><h3>Akustik tavan şart mı?</h3><p>Sert yüzeyli büyük odalarda şart sayılır. Tavanda ya da duvarda ses yutan yüzey olmazsa en küçük ses bile yankılanır.</p><h3>Su istasyonu için ne hazırlanır?</h3><p>Temiz su girişi, gider ve bir priz. Yeri planda yatakların akışını kesmeyecek bir noktada gösterilir.</p><h3>Mevcut bir oda dinlenme odasına dönüştürülebilir mi?</h3><p>Dönüştürülebilir. Önce mevcut durum çizilir, sonra akış, aydınlatma ve iklim değişiklikleri bu çizimin üstüne işlenir.</p><h3>Kaynaklar</h3><ul><li><a href="https://en.wikipedia.org/wiki/Thermal_comfort">Thermal comfort, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Dropped_ceiling">Dropped ceiling, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Soundproofing">Soundproofing, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Vapor_barrier">Vapor barrier, Wikipedia</a></li></ul><p><strong>Yazar hakkında.</strong> <a href="https://www.saunadekor.com.tr/urunler/">Sauna Dekor Spa Solutions</a> · 1987&#39;den beri sauna, hamam, buhar odası ve havuz üreticisi · İstanbul’da üretimde 40. yılımızdayız, 19 çalışan · TS EN ISO 9001:2015 · 41+ ülkede 5.000+ proje, 577+ otel ve resort projesi · 32 ülke ve bölgede 732 kayıtlı referans.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=c2e32d2f1142" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[A Salt Room: What the Drawings Must Show]]></title>
            <link>https://medium.com/@saunadekorspasolutions/a-salt-room-what-the-drawings-must-show-f878579cd956?source=rss-9a831ade41ce------2</link>
            <guid isPermaLink="false">https://medium.com/p/f878579cd956</guid>
            <category><![CDATA[interior-design]]></category>
            <category><![CDATA[architecture]]></category>
            <dc:creator><![CDATA[Sauna Dekor Spa Solutions]]></dc:creator>
            <pubDate>Thu, 19 Nov 2026 05:50:26 GMT</pubDate>
            <atom:updated>2026-11-19T05:50:26.334Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="Timber sauna lit by LED lines under each bench and behind the backrest, two wall lamps and a heater with stones in a timber guard" src="https://cdn-images-1.medium.com/max/1024/1*sLlirJddCGBQxt5tQCdhBA.jpeg" /></figure><p><em>Updated: 19 November 2026</em></p><p><strong>Short answer:</strong> a salt room drawing set has six parts: a plan with the room, its door, the technical space and the neighbours; a section through the wall build-up and ceiling; an electrical sheet with the halogenerator, lighting drivers and controls; a water and drain note; a ventilation sheet with the room’s own supply and extract; and details of the salt wall, floor edges and threshold. Sauna Dekor Spa Solutions checks these before ordering salt, because most salt room repairs trace back to a sheet nobody drew.</p><h3>Plan: what must the plan show?</h3><p><strong>On the drawing:</strong> the room’s internal dimensions, the door and its swing, the loungers or seats with a clear walkway, the position of every salt wall, and the technical space next door with its own door. The plan also names the neighbouring rooms on every side.</p><p><strong>If it is missing:</strong> the halogenerator ends up inside the room because nobody reserved a space for it, and the salt room shares a wall with a steam room or hammam because the neighbours were never written down. A hammam next door runs room air at 40–50 °C with wet floors; that is a wall the salt should not see.</p><h3>Section: what must the section show?</h3><p><strong>On the drawing:</strong> a cut through each salt wall showing the structural wall, the backing, the air gap, vapour control where needed, the fixing for salt bricks or panels, and the LED position behind the salt. A second cut through the ceiling shows the grille positions and the void above.</p><p><strong>If it is missing:</strong> salt goes straight onto fresh plaster, the air gap is forgotten, and the lighting is fixed wherever it fits. Salt is hygroscopic, so a wall that has not dried passes its water to the salt within weeks.</p><h3>Electrical: what must the electrical sheet show?</h3><p><strong>On the drawing:</strong> the halogenerator’s power point in the technical space, the control position outside the room, the lighting circuits, and every LED driver placed outside the room with its cable route and access point. The maker’s datasheet gives the halogenerator’s supply and its outlet position.</p><p><strong>If it is missing:</strong> drivers are fixed in the wall cavity behind the salt, controls end up inside the room, and the first lighting failure means taking blocks off the wall.</p><h3>Water and drain: what must the drawings say about water?</h3><p><strong>On the drawing:</strong> a clear note that the salt room has no water point and no floor drain, and that the floor base under loose salt is sealed. If a wet room sits above or beside it, the waterproofing of that room is drawn with the salt room in mind.</p><p><strong>If it is missing:</strong> a cleaner adds a hose point “for convenience”, a floor drain appears in the screed, or a leak from a shower above reaches the salt. Salt rooms are cleaned dry; water has no place in them.</p><h3>Ventilation: what must the ventilation sheet show?</h3><p><strong>On the drawing:</strong> the room’s own supply and extract, separate from wet rooms, grille positions that do not blow at the salt walls, a dehumidifier with its drain where the building is humid, and how the technical space is ventilated.</p><p><strong>If it is missing:</strong> the room is connected to the general spa extract, pulls humid air from the steam room corridor, and the salt turns dark by evening. Our <a href="https://saunadekor.com/products/salt-room/">salt room</a> page shows the rooms we build with their own air.</p><h3>Details: what must the detail sheets show?</h3><p><strong>On the drawing:</strong> the joint between salt and the ceiling, the edge trims that hold loose floor salt, the threshold height, the door seal, and the access hatch for each lit section. If the floor is salt tiles instead of loose salt, the tile bed and edge are drawn too.</p><p><strong>If it is missing:</strong> floor salt spills into the corridor, the door does not close over the salt, and the lighting cannot be reached without opening the wall.</p><h3>Which sheets belong in the set, and who draws them?</h3><ul><li><strong>Plan</strong> — room, door swing, loungers, salt walls, technical space, neighbours (architect or spa designer)</li><li><strong>Section</strong> — wall build-up, air gap, vapour control, fixings, ceiling and grilles (salt room builder)</li><li><strong>Electrical</strong> — halogenerator power, controls outside, driver positions, cable routes (electrical engineer)</li><li><strong>Water and drain</strong> — no water point, no drain, sealed base, wet rooms above or beside (MEP engineer)</li><li><strong>Ventilation</strong> — own supply and extract, grille positions, dehumidifier, technical space air (MEP engineer)</li><li><strong>Details</strong> — salt-to-ceiling joint, edge trims, threshold, door seal, access hatches (salt room builder)</li></ul><h3>Frequently asked questions</h3><h3>Who prepares the salt room drawings?</h3><p>The architect or spa designer draws the plan; the salt room builder draws the section and details; the electrical and MEP engineers draw their sheets. One person checks the set together before salt is ordered.</p><h3>Does a salt room need a floor drain?</h3><p>No. It is cleaned dry, so a floor drain only invites water. The floor base is sealed, and loose salt is held by edge trims and a threshold.</p><h3>Where is the halogenerator drawn?</h3><p>In a technical space beside the room, with its outlet through the shared wall and its control outside the door. The maker’s manual gives the outlet height and service clearance.</p><h3>Can the salt room share the spa’s ventilation drawing?</h3><p>It can sit on the same sheet, but it must be its own zone, with its own supply and extract and no connection to the wet rooms’ extract.</p><h3>What happens after the drawings are checked?</h3><p>Missing sheets are drawn, the salt quantity and fixing are fixed from the section, and the build follows in order: services, backing walls, ceiling, drying, salt, floor, halogenerator.</p><h3>Further reading</h3><ul><li><a href="https://en.wikipedia.org/wiki/Architectural_drawing">Architectural drawing, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Hygroscopy">Hygroscopy, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Vapor_barrier">Vapor barrier, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Mechanical_room">Mechanical room, Wikipedia</a></li></ul><p><strong>About the author.</strong> <a href="https://saunadekor.com/products/">Sauna Dekor Spa Solutions</a> · sauna, steam room, hammam and pool manufacturer since 1987 · now in our 40th year of manufacturing in Istanbul · team of 19 · TS EN ISO 9001:2015 · 5,000+ projects in 41+ countries, including 577+ hotel and resort projects · 732 documented references in 32 countries and territories.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=f878579cd956" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Yat saunası: çizimde olması gerekenler]]></title>
            <link>https://medium.com/@saunadekorspasolutions/yat-saunas%C4%B1-%C3%A7izimde-olmas%C4%B1-gerekenler-4d48a4973f6c?source=rss-9a831ade41ce------2</link>
            <guid isPermaLink="false">https://medium.com/p/4d48a4973f6c</guid>
            <category><![CDATA[interior-design]]></category>
            <category><![CDATA[sauna]]></category>
            <category><![CDATA[yachts]]></category>
            <dc:creator><![CDATA[Sauna Dekor Spa Solutions]]></dc:creator>
            <pubDate>Wed, 18 Nov 2026 12:09:42 GMT</pubDate>
            <atom:updated>2026-11-18T12:09:42.740Z</atom:updated>
            <content:encoded><![CDATA[<p><em>Güncelleme: 18 Kasım 2026</em></p><figure><img alt="Cam duvarlı yat saunasında yıldız ışıklı tavan, yarma taş bantlı duvar, altı ışıklı havada duran banklar ve bank üstünde ahşap kova" src="https://cdn-images-1.medium.com/max/1024/1*I6T9Ta5oxUCm6TRSVrsgFg.jpeg" /></figure><p><strong>Kısa cevap:</strong> yat saunasının çizim setinde altı pafta bulunmalı: genel yerleşim üzerinde kabin planı, gövde katmanlarını gösteren kesit, gemi elektriğine bağlanan hat şeması, eşik ve gider detayı, hava giriş ve çıkış yolu, bank konsolu ile aksesuar sabitleme detayı. Karada eksik bir pafta şantiyede telafi edilir; teknede ise kabinin çevresi tersanenin başka ekipleriyle paylaşıldığı için eksik bilgi çoğu zaman sökme demektir.</p><p>Yat saunası 80–100 °C kuru sıcakta çalışır. Çizimi deniz mimarının genel yerleşim planı üzerine kurulur ve her pafta tersane programının bir aşamasına karşılık gelir.</p><h3>Plan paftasında ne görünmeli?</h3><p><strong>Çizimde ne görünmeli:</strong> kabinin iç ölçüleri, kapının açılış yönü, cam cephelerin yeri, bank düzeni ve ısıtıcının konumu. Kabinin geminin hangi bölmesinde olduğu ve çevresindeki servis boşluğu da plana işlenir.</p><p><strong>Eksikse sahada ne olur:</strong> kapı koridora ya da merdivene doğru açılır, servis boşluğu tersanenin boru hattına verilir. Cam cephe sayısı plandan okunamazsa ısıtıcı yanlış hacme göre seçilir; cam ve taş yüzey hacme eklenmesi gereken bir yüktür. Harvia’nın kuralı her m² cam ya da taş için yaklaşık 1,2 m³ eklemektir.</p><h3>Kesitte hangi katmanlar gösterilir?</h3><p><strong>Çizimde ne görünmeli:</strong> teknenin taşıyıcı duvarından içeriye doğru bütün katmanlar: yalıtım, buhar bariyeri, hava boşluğu, gövde levhası ve lambri. Tavan yüksekliği, tavandaki ışık ya da yıldız tavan fiberlerinin geçtiği boşluk ve zemin kotu aynı kesitte okunmalı.</p><p><strong>Eksikse sahada ne olur:</strong> buhar bariyeri cam birleşiminde ya da taş cephede kesilir, nem gövdeye geçer. Tavan boşluğu ayrılmamışsa yıldız tavanın fiberleri için tavan sonradan alçaltılır.</p><figure><img alt="Yat saunasında iki kademeli havada duran banklar, solda yarma taş bant, ön bankın altında siyah dikdörtgen menfez ve beyaz delikli tavan" src="https://cdn-images-1.medium.com/max/1024/1*qeZq9resgAdl18BR7PCGWw.jpeg" /></figure><h3>Elektrik paftasında neler yer alır?</h3><p><strong>Çizimde ne görünmeli:</strong> ısıtıcı hattının geminin hangi panosundan çıkacağı, gemi elektriğinin gerilim ve frekansı, kumanda panelinin yeri, sensörlerin ve ışıkların kablo yolları. Yedek boş boru da bu paftadadır.</p><p><strong>Eksikse sahada ne olur:</strong> ısıtıcı geminin şebekesine uymaz ya da panoda yer kalmaz. Kumanda paneli güverteye bakan bir duvara düşer. Sonradan eklenen her sensör için lambri sökülür.</p><h3>Su ve gider paftası neden gerekir?</h3><p><strong>Çizimde ne görünmeli:</strong> kabin eşiği, güvertedeki ızgaralı kanal, iç zeminin eğimi ve gidere bağlantı. Kabin önünde duş varsa onun gideri de aynı paftadadır.</p><p><strong>Eksikse sahada ne olur:</strong> ıslak ayakla girilen kabinde su eşikte durmaz, bank altına yürür. Mermer zeminde derzler koyulaşır.</p><h3>Havalandırma paftasında ne görünmeli?</h3><p><strong>Çizimde ne görünmeli:</strong> taze hava girişinin ısıtıcıya göre yeri, egzozun çıkış noktası ve kanalın geminin hangi hava sistemine bağlanacağı.</p><p><strong>Eksikse sahada ne olur:</strong> egzoz yaşam alanının hava sistemine verilir ve sıcak hava komşu kamaraya gider. Kabin içinde sıcaklık katmanları bozulur, üst bank ile alt bank arasında fark büyür.</p><h3>Bitiş ve detay paftası neyi gösterir?</h3><p><strong>Çizimde ne görünmeli:</strong> bankların duvara hangi konsolla tutturulduğu, ısıtıcının önündeki sökülebilir servis kapağı, menfezlerin yeri, ışık şeritlerinin sırtlık arkasındaki konumu ve kova, kepçe, sırtlık gibi parçaların sabitleme biçimi.</p><p><strong>Eksikse sahada ne olur:</strong> havada duran banklar için konsol yeri duvarda takviyesiz kalır. Serbest bırakılan aksesuarlar seyirde düşer.</p><p>Turquoise Yachts ile yaptığımız son kabinde banklar özel konsollarla duvara bağlı, EOS 46.U ısıtıcı bank arkasında. Kabinin fotoğrafları <a href="https://www.saunadekor.com.tr/proje/yat-saunasi-turquoise-yachts-2026/">yat saunası proje sayfamızda</a> bulunuyor.</p><h3>Pafta kontrol tablosu</h3><ul><li><strong>Plan</strong>: Olması gereken: Ölçü, kapı yönü, cam cephe, bank, ısıtıcı yeri, servis boşluğu; Kim çizer: Sauna Dekor, deniz mimarının yerleşim planı üzerine</li><li><strong>Kesit</strong>: Olması gereken: Yalıtım, buhar bariyeri, hava boşluğu, gövde, lambri, tavan boşluğu; Kim çizer: Sauna Dekor</li><li><strong>Elektrik</strong>: Olması gereken: Gemi panosu, gerilim, hat, panel yeri, sensör ve ışık yolları, boş boru; Kim çizer: Tersane elektrik ekibi ile Sauna Dekor</li><li><strong>Su ve gider</strong>: Olması gereken: Eşik, ızgaralı kanal, zemin eğimi, duş gideri; Kim çizer: Tersane ile Sauna Dekor</li><li><strong>Havalandırma</strong>: Olması gereken: Taze hava, egzoz, bağlanılan gemi sistemi; Kim çizer: Tersane mekanik ekibi</li><li><strong>Bitiş ve detay</strong>: Olması gereken: Konsol, servis kapağı, menfez, ışık, aksesuar sabitleme; Kim çizer: Sauna Dekor</li></ul><p>Her projede işçilik ve imalatta 24 ay, elektrikli ve mekanik ekipmanlarda 24 ay üretici garantisi, taşıyıcı yapı ve su yalıtımında 5 yıl garanti verilir.</p><h3>Sıkça sorulan sorular</h3><h4>Çizim seti hangi aşamada hazırlanır?</h4><p>Deniz mimarının genel yerleşim planı kesinleştiğinde. İç kaplamalar başlamadan önce elektrik ve hava paftaları tersaneye teslim edilir.</p><h4>Deniz mimarı bizim çizimimizi onaylar mı?</h4><p>Evet. Ağırlık, yangın şartları ve gemi sistemleriyle bağlantılar deniz mimarının ve tersanenin onayından geçer.</p><h4>Cam cephe ısıtıcı seçimini değiştirir mi?</h4><p>Değiştirir. Cam ve taş yüzey ısıyı ahşaptan farklı tutar; Harvia her m² için yaklaşık 1,2 m³ eklenmesini öneriyor.</p><h4>Yıldız tavan için ayrı bir pafta gerekir mi?</h4><p>Gerekmez; kesitte tavan boşluğu ve elektrik paftasında ışık kaynağının yeri gösterilir.</p><h4>Mevcut bir çizimi kontrol edebilir misiniz?</h4><p>Edebiliriz. Genel yerleşim planı ile kabin çizimini gönderirseniz pafta pafta eksikleri yazılı olarak iletiriz.</p><h3>Kaynaklar</h3><ul><li><a href="https://tr.wikipedia.org/wiki/Sauna">Vikipedi: Sauna</a></li><li><a href="https://tr.wikipedia.org/wiki/Yat">Vikipedi: Yat</a></li><li><a href="https://en.wikipedia.org/wiki/Vapor_barrier">Vapor barrier, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/International_Convention_for_the_Safety_of_Life_at_Sea">International Convention for the Safety of Life at Sea, Wikipedia</a></li><li><a href="https://www.harvia.com/en/support/">Harvia, ürün desteği ve kılavuzlar</a></li></ul><p><strong>Yazar hakkında.</strong> <a href="https://www.saunadekor.com.tr/urunler/">Sauna Dekor Spa Solutions</a> · 1987&#39;den beri sauna, hamam, buhar odası ve havuz üreticisi · İstanbul’da 40 yıllık üretim, 19 çalışan · TS EN ISO 9001:2015 · 41+ ülkede 5.000+ proje, 577+ otel ve resort projesi · 32 ülke ve bölgede 732 kayıtlı referans.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=4d48a4973f6c" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[A Hammam in Dubai: Five Mistakes Owners Ask Us to Fix]]></title>
            <link>https://medium.com/@saunadekorspasolutions/a-hammam-in-dubai-five-mistakes-owners-ask-us-to-fix-d33cb1190c7a?source=rss-9a831ade41ce------2</link>
            <guid isPermaLink="false">https://medium.com/p/d33cb1190c7a</guid>
            <category><![CDATA[dubai]]></category>
            <category><![CDATA[interior-design]]></category>
            <category><![CDATA[home-improvement]]></category>
            <dc:creator><![CDATA[Sauna Dekor Spa Solutions]]></dc:creator>
            <pubDate>Wed, 18 Nov 2026 12:04:37 GMT</pubDate>
            <atom:updated>2026-11-18T12:04:37.468Z</atom:updated>
            <content:encoded><![CDATA[<p><em>Updated: 18 November 2026</em></p><figure><img alt="Stone-lined hammam with a barrel-vaulted ceiling and small downlights, a raised stone floor area edged with a lit strip, textured stone basins with bronze taps and hand showers, and a lit lattice panel in an arched niche" src="https://cdn-images-1.medium.com/max/1024/1*cUXDEV-gly_hjSuvo1luzw.jpeg" /></figure><p><strong>Short answer:</strong> the five mistakes owners of hammams in Dubai homes most often ask Sauna Dekor Spa Solutions to fix are: a steam generator in a hot, closed cupboard, stone slabs cut larger than the lift or stair can take, damp and staining after the house is shut for the summer, controls that household staff cannot run, and “cold” water that arrives warm from a roof tank. None of these is about design style; all five come from the climate, the building and the way a villa is lived in.</p><h3>Which five mistakes come up most often?</h3><ul><li><strong>1. Generator in a hot, closed cupboard</strong>: What the owner notices: Generator trips or stops in summer; Fix: Ventilated plant space, or the unit moved</li><li><strong>2. Slabs too large for the route</strong>: What the owner notices: Stone broken in delivery, programme lost; Fix: Slabs re-cut to the lift and stair size</li><li><strong>3. Summer shutdown</strong>: What the owner notices: Damp smell and dark joints on return; Fix: Drying cycle and a shutdown routine</li><li><strong>4. Controls staff cannot run</strong>: What the owner notices: Hammam left off or left on all day; Fix: One simple programme, controls outside</li><li><strong>5. Warm “cold” water</strong>: What the owner notices: Basin water too hot in summer; Fix: Cold feed checked, mixing reset</li></ul><h3>1. Why does the generator stop in summer?</h3><p><strong>What we see:</strong> a steam generator in a closed cupboard in a garage, on a roof or next to a hot-water cylinder, that trips or slows down on summer afternoons.</p><p><strong>Why it happens:</strong> the cupboard has no ventilation, and the air round the generator is far hotter than the maker’s installation guide allows.</p><p><strong>How we fix it:</strong> the cupboard gets a ventilation path, or the generator is moved into a cooled plant room with a short steam line. We pair Condair generators with our rooms; installation limits are the maker’s, and we keep spare parts in stock in Istanbul for the equipment we install.</p><p><strong>How to avoid it:</strong> check the generator position against the maker’s installation guide before the cupboard is built.</p><h3>2. Why did the stone not fit the lift?</h3><p><strong>What we see:</strong> large marble slabs that cannot turn in a stair or enter a service lift, broken corners on delivery and weeks lost while new slabs are cut.</p><p><strong>Why it happens:</strong> the slab layout was drawn for the room, with nobody measuring the route from the street to the hammam.</p><p><strong>How we fix it:</strong> the slab layout is redrawn to the largest piece the route can take, and joints are placed where they read as part of the design.</p><p><strong>How to avoid it:</strong> measure lift cabin, doors and stair turns before the slab layout is approved. The villa hammams we build in the UAE are on our <a href="https://saunadekor.com/hammam-dubai/">hammam</a> page.</p><figure><img alt="Stone hammam seen from the entrance, with a barrel-vaulted ceiling, a lit lattice panel in an arched niche between two smaller lit niches, copper hand showers on both side walls and a raised floor area edged with light" src="https://cdn-images-1.medium.com/max/1024/1*GG1rxMIh9pw-vYikEItKOA.jpeg" /></figure><h3>3. Why is the hammam damp after the summer?</h3><p><strong>What we see:</strong> a damp smell, dark spots in joints and water marks on stone when the family returns after weeks away.</p><p><strong>Why it happens:</strong> the house was shut, the air-conditioning set back, and the hammam was left with water in its traps and no extract running.</p><p><strong>How we fix it:</strong> the room is cleaned and dried, joints are checked, and the extract is set to run on a timer while the house is empty.</p><p><strong>How to avoid it:</strong> agree a shutdown routine at handover: generator drained to the maker’s instructions, door left ajar, extract on a timer.</p><h3>4. Why is the hammam left off, or on all day?</h3><p><strong>What we see:</strong> a hammam that is never used because nobody knows how to start it, or one that runs from morning to night.</p><p><strong>Why it happens:</strong> the control panel sits inside the room or in a cupboard, with settings for every function and no simple start routine.</p><p><strong>How we fix it:</strong> the control is moved outside the room and set to one programme: warm-up, session, drying. The room air is set to 40–50 °C.</p><p><strong>How to avoid it:</strong> ask for a one-page instruction for household staff as part of handover.</p><h3>5. Why is the basin water too hot in summer?</h3><p><strong>What we see:</strong> basin water that is too hot to use in July and August, even with the mixing valve turned to cold.</p><p><strong>Why it happens:</strong> the cold feed comes from a roof tank or pipes in a warm ceiling void, so the “cold” water itself arrives warm.</p><p><strong>How we fix it:</strong> the cold feed route is checked and, where possible, taken from a cooler supply; the mixing valve is reset to the summer water.</p><p><strong>How to avoid it:</strong> ask the plumber where the cold water to the hammam actually comes from.</p><h3>Frequently asked questions</h3><h4>Can these problems be fixed without closing the hammam for long?</h4><p>Controls, extract timers and mixing settings take a day or two. Moving a generator or re-cutting stone takes longer.</p><h4>How long does a villa hammam take to build?</h4><p>3–8 weeks for homes and up to 12 weeks for large projects.</p><h4>Do you service hammams other companies built?</h4><p>Yes. Photos of the plant cupboard, the control panel and the room are enough for a first view.</p><h4>What warranty do you give?</h4><p>24 months on workmanship and manufacturing, 24 months manufacturer’s warranty on electrical and mechanical equipment, and 5 years on structure and waterproofing, on every project.</p><h3>Further reading</h3><ul><li><a href="https://en.wikipedia.org/wiki/Hammam">Hammam, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Thermostatic_mixing_valve">Thermostatic mixing valve, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Ventilation_(architecture)">Ventilation (architecture), Wikipedia</a></li><li><a href="https://www.condair.com/">Condair, steam generators</a></li></ul><p><strong>About the author.</strong> <a href="https://saunadekor.com/products/">Sauna Dekor Spa Solutions</a> · sauna, steam room, hammam and pool manufacturer since 1987 · 40 years of manufacturing in Istanbul · team of 19 · TS EN ISO 9001:2015 · 5,000+ projects in 41+ countries, including 577+ hotel and resort projects · 732 documented references in 32 countries and territories.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=d33cb1190c7a" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Cryotherapy Cabin or Cold Plunge in a Studio: Rooms Compared]]></title>
            <link>https://medium.com/@saunadekorspasolutions/cryotherapy-cabin-or-cold-plunge-in-a-studio-rooms-compared-92fa40ef95a0?source=rss-9a831ade41ce------2</link>
            <guid isPermaLink="false">https://medium.com/p/92fa40ef95a0</guid>
            <category><![CDATA[interior-design]]></category>
            <category><![CDATA[construction]]></category>
            <dc:creator><![CDATA[Sauna Dekor Spa Solutions]]></dc:creator>
            <pubDate>Tue, 17 Nov 2026 12:16:35 GMT</pubDate>
            <atom:updated>2026-11-17T12:16:35.224Z</atom:updated>
            <content:encoded><![CDATA[<p><em>Updated: 17 November 2026</em></p><figure><img alt="Ice fountain in a dark timber-clad room: a slatted timber pedestal with a glass-edged ice tray under a stainless steel ceiling pipe, two timber blocks beside it and warm light along the wall base" src="https://cdn-images-1.medium.com/max/1024/1*OwIGJJuZbPSyEuqEieSQfw.jpeg" /></figure><p><strong>Short answer:</strong> an electric cryotherapy cabin needs a dry room, a dedicated power circuit and a way to remove the heat its cooling system gives off. A cold plunge pool needs water, filtration, a drain, a floor that carries the weight of the water and a room built for humidity. Sauna Dekor Spa Solutions plans both in studios and gyms, and the choice usually comes down to which of these the building can give. This article compares the rooms only.</p><p>We do not make cryotherapy cabins. Electric cabins such as CryoOne are the maker’s product, with the maker’s documents. We build cold plunge pools for water temperatures from 2 to 15 °C, and we prepare the room for either.</p><h3>How do the two rooms compare at a glance?</h3><ul><li><strong>Power:</strong> Electric cryotherapy cabin: Dedicated circuit from the cabin data sheet; Cold plunge pool: Circuits for chiller, pump and controls, with residual-current protection</li><li><strong>Water:</strong> Electric cryotherapy cabin: None; Cold plunge pool: Fill point, filtration and treatment</li><li><strong>Drain:</strong> Electric cryotherapy cabin: None for the cabin; Cold plunge pool: Floor drain and a way to empty the pool</li><li><strong>Floor:</strong> Electric cryotherapy cabin: Cabin weight on its feet, level floor; Cold plunge pool: Weight of the water, the shell and people</li><li><strong>Humidity:</strong> Electric cryotherapy cabin: Dry room required; Cold plunge pool: Wet room, evaporation from the water surface</li><li><strong>Heat:</strong> Electric cryotherapy cabin: Cooling system gives heat to the room; Cold plunge pool: Chiller gives heat where it stands</li><li><strong>Service space:</strong> Electric cryotherapy cabin: Behind and beside the cabin; Cold plunge pool: Around the plant: chiller, pump, filter</li><li><strong>Cleaning:</strong> Electric cryotherapy cabin: Dry wipe-down; Cold plunge pool: Water care, wet floor cleaning</li></ul><h3>What changes for the power supply?</h3><p>Both need a dedicated supply, but for different loads. The cabin is one appliance with its own data sheet: power, phases and protection come from there. A cold plunge has a chiller, a circulation pump and controls, and it sits next to water, so residual-current protection and the electrical rules for wet locations apply to every circuit. In both cases a licensed electrician sizes the supply from the makers’ data.</p><h3>What does water bring into the room?</h3><p>Water is the biggest difference. A cold plunge pool needs a fill point, a filter, water treatment and a drain to empty it for cleaning. Water splashes, people step out wet, and the floor around the pool needs a slope to a drain and an anti-slip finish.</p><p>An electric cabin brings no water into the room. That is why it should not sit in a wet zone: humidity from a steam room or a plunge next door condenses on its cold surfaces.</p><figure><img alt="Shower corner in dark bronze-toned tiles, with a wooden tip-over bucket on a wall bracket, a pull chain and a ceiling rain shower running beside it" src="https://cdn-images-1.medium.com/max/1024/1*phTzTYprdwjCWp9EnLLWOg.jpeg" /></figure><p>A cold plunge belongs on the wet side of a plan, with stone or tiled floors and drains. A cryotherapy cabin belongs on the dry side.</p><h3>How heavy is each one on the floor?</h3><p>A litre of water weighs about a kilogram, so even a small plunge pool puts a large, even load on the slab once filled, plus the shell and the people in it. On an upper floor or a mezzanine, a structural engineer checks it before the pool is drawn. A cabin’s weight sits on its feet; the floor must be level and hard, and the weight comes from the data sheet.</p><h3>Where does the heat go?</h3><p>Both make cold by moving heat somewhere else. The cabin’s cooling system gives that heat to the room it stands in, so the room needs extract and fresh air sized for it. The cold plunge chiller gives its heat where the chiller stands; if that is a cupboard, the cupboard needs air too. Neither should push warm air into a corridor.</p><h3>What about service and cleaning?</h3><p>The cabin needs clear space behind and beside it for filters and electrics, as the maker’s manual states. The plunge needs access to the chiller, pump and filter, plus room to drain and clean the pool. Day to day, the cabin is wiped dry; the plunge needs water care and a wet clean of the floor.</p><p>Room requirements for cabins are on our <a href="https://saunadekor.com/cryotherapy/">cryotherapy</a> page.</p><h3>Frequently asked questions</h3><h4>Can a studio have both in the same room?</h4><p>Not ideally. The plunge makes the room humid, and the cabin needs dry air. Two rooms next to each other, one wet and one dry, work better.</p><h4>Does an electric cabin need a technical room?</h4><p>Usually not; its cooling system is built in. The room itself becomes the place where its heat goes, so ventilation is planned for it.</p><h4>What water temperature do your plunge pools reach?</h4><p>We build cold plunge pools for water temperatures from 2 to 15 °C. The chiller and the pool size are chosen together.</p><h4>Do you make the cabins?</h4><p>No. We supply, install and commission them and prepare the room; the cabin and its documents belong to the maker.</p><h4>What warranty do you give?</h4><p>24 months on workmanship and manufacturing, 24 months manufacturer’s warranty on electrical and mechanical equipment, and 5 years on structure and waterproofing, on every project.</p><h3>Further reading</h3><ul><li><a href="https://en.wikipedia.org/wiki/Cryotherapy">Cryotherapy, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Vapor-compression_refrigeration">Vapor-compression refrigeration, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Residual-current_device">Residual-current device, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Chiller">Water chiller, Wikipedia</a></li></ul><p><strong>About the author.</strong> <a href="https://saunadekor.com/products/">Sauna Dekor Spa Solutions</a> · sauna, steam room, hammam and pool manufacturer since 1987 · now in our 40th year of manufacturing in Istanbul · team of 19 · TS EN ISO 9001:2015 · 5,000+ projects in 41+ countries, including 577+ hotel and resort projects · 732 documented references in 32 countries and territories.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=92fa40ef95a0" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Dinlenme ve masaj yatağı: çizimde olması gerekenler]]></title>
            <link>https://medium.com/@saunadekorspasolutions/dinlenme-ve-masaj-yata%C4%9F%C4%B1-%C3%A7izimde-olmas%C4%B1-gerekenler-a83fe080dff0?source=rss-9a831ade41ce------2</link>
            <guid isPermaLink="false">https://medium.com/p/a83fe080dff0</guid>
            <category><![CDATA[interior-design]]></category>
            <category><![CDATA[wellness]]></category>
            <dc:creator><![CDATA[Sauna Dekor Spa Solutions]]></dc:creator>
            <pubDate>Sun, 15 Nov 2026 23:50:10 GMT</pubDate>
            <atom:updated>2026-11-15T23:50:10.907Z</atom:updated>
            <content:encoded><![CDATA[<p><em>Güncelleme: 16 Kasım 2026</em></p><figure><img alt="Gri damarlı mermer kaplı hamamda alt kenarından ışıklı mermer göbektaşı, oval gömme tavan ışığı ve duvarda acil durdurma butonu" src="https://cdn-images-1.medium.com/max/887/1*ycBUcbmUkCh-yyCOvtoTpw.jpeg" /></figure><p><strong>Kısa cevap:</strong> dinlenme ve masaj yatağının çizimi altı başlıkta tamamlanır: plan (yatağın yeri, çevresindeki geçiş, servis yolu), kesit (taşıyıcı kabuk, ısıtma katmanı, zemin yükü), elektrik (ayrı hat, termostat ve kumanda yeri), su ve gider (ıslak alandaki yatak çevresinin eğimi), havalandırma (yatağın üstüne gelen hava) ve yüzey detayı (malzeme, derz, servis kapağı). Sauna Dekor Spa Solutions yatağı dinlenme alanının ya da masaj odasının parçası olarak çizer; yatak sonradan gelip yer arayan bir mobilya olmamalı.</p><p>Isıtmalı dinlenme yatağı taş, mermer, cam ya da seramik bir yüzeydir; altındaki ısıtma hattı ısıyı yüzeye verir. Masaj yatağı ise çoğunlukla motorlu ve ayarlı bir cihazdır. İkisinin çizimi aynı paftalardan geçer ama sorduğu soru farklıdır.</p><h3>Planda ne görünmeli?</h3><p><strong>Çizimde:</strong> her yatağın yeri ve yönü, yatağın çevresindeki geçiş, kapıya ve ıslak hacimlere uzaklığı, dinlenme alanında kaç yatak olacağı, masaj yatağında terapistin dolaştığı çalışma alanı. Yatağın binaya hangi kapıdan, hangi asansörden girdiği de servis yolu olarak işaretlenir.</p><p><strong>Eksikse sahada ne olur:</strong> yataklar yan yana sıkışır, ıslak ayakla gelen kişi kuru yatağın üstünden geçer. Motorlu masaj yatağı koridor dönüşünde kalır.</p><h3>Kesitte ne görünmeli?</h3><p><strong>Çizimde:</strong> ısıtmalı yatağın taşıyıcı kabuğu, ısıtma hattının yeri, altındaki ısı yalıtımı, üstteki kaplama katmanı ve yatağın döşemeye nasıl oturduğu. Taş ve mermer yataklar ağırdır; döşemenin bu yükü taşıdığı statik proje notuyla gösterilir.</p><p><strong>Eksikse sahada ne olur:</strong> ısı yüzeye değil döşemeye gider, yatak geç ısınır. Asma döşemede yük hesabı yapılmadıysa yatağın yeri değişir.</p><ul><li><strong>Plan</strong> · Olması gereken: yatak yeri, geçiş, ıslak hacme uzaklık, servis yolu · Kim çizer: mimar ve spa tasarımcısı</li><li><strong>Kesit</strong> · Olması gereken: taşıyıcı kabuk, ısıtma katmanı, yalıtım, döşeme yükü · Kim çizer: mimar ve statik mühendisi</li><li><strong>Elektrik</strong> · Olması gereken: ayrı hat, termostat, sensör ve kumanda yeri · Kim çizer: elektrik mühendisi</li><li><strong>Su ve gider</strong> · Olması gereken: yatak çevresinde zemin eğimi, süzgeç · Kim çizer: mekanik mühendisi</li><li><strong>Havalandırma</strong> · Olması gereken: menfezlerin yatağa göre yeri · Kim çizer: mekanik mühendisi</li><li><strong>Yüzey ve detay</strong> · Olması gereken: kaplama, derz, servis kapağı · Kim çizer: iç mimar ve imalatçı</li></ul><h3>Elektrik paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> her ısıtmalı yatak ve motorlu masaj yatağı için ayrı hat ve sigorta, kaçak akım koruması, yüzey sıcaklığını okuyan sensörün yeri, termostatın yatağın dışında ve elle ulaşılan bir noktada durduğu. Cihazların güç değeri üreticinin föyünden paftaya yazılır.</p><p><strong>Eksikse sahada ne olur:</strong> ısıtmalı yatak bir priz hattına bağlanır, sigorta atar. Termostat yatağın altında kalırsa ayar için kaplama sökülür.</p><figure><img alt="Mermer kaplı hamamın ortasında alttan ışıklı mermer göbektaşı, arkada mermer seki üzerinde kurna ve iki bronz musluk, tavanda geniş halka ışık" src="https://cdn-images-1.medium.com/max/813/1*V2KTOHUloLY4J-9KtUNroQ.jpeg" /></figure><h3>Su ve gider paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> yatak ıslak alanda ya da havuz çevresindeyse zeminin yataktan uzağa, süzgece doğru eğimi; yatağın dibinde su birikmeyeceği; yatak gövdesinde su almayan detay. Kuru dinlenme odasındaki yatak için gider gerekmez, bu da paftaya yazılır.</p><p><strong>Eksikse sahada ne olur:</strong> yatak dibinde su göllenir, derzler koyulaşır. Motorlu yatak ıslak zemine konursa mekanizması zarar görür.</p><h3>Havalandırma paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> taze hava ve emiş menfezlerinin yataklara göre yeri, hiçbir menfezin uzanan kişinin üstüne üflemediği, ısıtmalı yatakların ısısının odanın iklim hesabına katıldığı.</p><p><strong>Eksikse sahada ne olur:</strong> ısıtmalı yatakta yatan kişiye soğuk hava gelir, yatak ısındıkça oda da ısınır ve klima sürekli çalışır.</p><h3>Yüzey ve detay paftasında ne görünmeli?</h3><p><strong>Çizimde:</strong> yüzey malzemesi (taş, mermer, cam mozaik ya da seramik), derz dolgusunun ıslak hacme uygun türü, kenar yuvarlatması ve ısıtma bağlantılarına ulaşan servis kapağının yeri.</p><p><strong>Eksikse sahada ne olur:</strong> derz kısa sürede lekelenir, keskin kenar rahatsız eder, arızada ısıtma hattına ulaşmak için yatak kırılır.</p><p>Masaj yatakları ve hazır ısıtmalı yataklar kendi üreticisinden gelir; biz yerleşimi, altyapıyı ve çevresindeki kaplamayı yapıyoruz. Ayrıntılar <a href="https://www.saunadekor.com.tr/dinlenme-ve-masaj-yatagi/">dinlenme ve masaj yatağı</a> sayfamızda. Her projede işçilik ve imalatta 24 ay, elektrikli ve mekanik ekipmanlarda 24 ay üretici garantisi, taşıyıcı yapı ve su yalıtımında 5 yıl garanti verilir.</p><h3>Sıkça sorulan sorular</h3><h3>Isıtmalı yatak için ayrı hat şart mı?</h3><p>Çoğu modelde şart. Gücü üreticinin föyünde yazar; hat, sigorta ve kaçak akım koruması buna göre seçilir.</p><h3>Taş yatak asma döşemeye konabilir mi?</h3><p>Konabilir ama önce statik mühendisi yükü kontrol eder. Gerekirse yatağın yeri taşıyıcı kirişin üstüne alınır.</p><h3>Servis kapağı nereye konur?</h3><p>Yatağın görünmeyen yüzüne, ısıtma bağlantılarına en kısa yoldan ulaşılan noktaya. Yeri kesit paftasında gösterilir.</p><h3>Masaj yatağı ıslak alana konur mu?</h3><p>Motorlu yatak konmaz, kuru odada durur. Islak alanda ısıtmalı taş ya da mozaik yüzeyli yataklar kullanılır.</p><h3>Çizim seti yatak seçilmeden hazırlanabilir mi?</h3><p>Plan ve kesit başlayabilir. Elektrik paftası, yatağın modeli ve gücü belli olunca kesinleşir.</p><h3>Kaynaklar</h3><ul><li><a href="https://en.wikipedia.org/wiki/Massage_table">Massage table, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Underfloor_heating">Underfloor heating, Wikipedia</a></li><li><a href="https://tr.wikipedia.org/wiki/Mermer">Vikipedi: Mermer</a></li><li><a href="https://en.wikipedia.org/wiki/Grout">Grout, Wikipedia</a></li></ul><p><strong>Yazar hakkında.</strong> <a href="https://www.saunadekor.com.tr/urunler/">Sauna Dekor Spa Solutions</a> · 1987&#39;den beri sauna, hamam, buhar odası ve havuz üreticisi · İstanbul’da 40 yıllık üretim, 19 çalışan · TS EN ISO 9001:2015 · 41+ ülkede 5.000+ proje, 577+ otel ve resort projesi · 32 ülke ve bölgede 732 kayıtlı referans.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=a83fe080dff0" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[A Spa Fit-Out Contract: Five Mistakes Owners Ask Us to Fix]]></title>
            <link>https://medium.com/@saunadekorspasolutions/a-spa-fit-out-contract-five-mistakes-owners-ask-us-to-fix-758474963978?source=rss-9a831ade41ce------2</link>
            <guid isPermaLink="false">https://medium.com/p/758474963978</guid>
            <category><![CDATA[interior-design]]></category>
            <category><![CDATA[sauna]]></category>
            <category><![CDATA[construction]]></category>
            <dc:creator><![CDATA[Sauna Dekor Spa Solutions]]></dc:creator>
            <pubDate>Sun, 15 Nov 2026 23:47:45 GMT</pubDate>
            <atom:updated>2026-11-15T23:47:45.856Z</atom:updated>
            <content:encoded><![CDATA[<p><em>Updated: 16 November 2026</em></p><figure><img alt="Steam room with grey and white mosaic walls, a fibre-optic star ceiling, a perimeter light line where wall meets ceiling and a tiled bench lit from below" src="https://cdn-images-1.medium.com/max/1024/1*hJIAA8DtYCK7FT2gLOvZBA.jpeg" /></figure><p><strong>Short answer:</strong> the five spa fit-out contract mistakes owners most often ask Sauna Dekor Spa Solutions to help untangle are: a scope that lists room names instead of room data, payment stages that are not tied to a completed and tested step, a warranty written as one line, no acceptance criteria for handover, and no procedure for changes asked for on site. All five live in the contract text, and all five are cheaper to fix before signing than after.</p><h3>Which five mistakes come up most often?</h3><ul><li><strong>1</strong> · Mistake: Scope as room names · What the owner notices: “Sauna” means different things to each side · Fix in the contract: Room data sheet attached per room</li><li><strong>2</strong> · Mistake: Stages without tests · What the owner notices: Stage reached, work not working · Fix in the contract: Each stage closed by a named test</li><li><strong>3</strong> · Mistake: One-line warranty · What the owner notices: Dispute over what is covered · Fix in the contract: Warranty split by work type and period</li><li><strong>4</strong> · Mistake: No acceptance criteria · What the owner notices: Handover argued room by room · Fix in the contract: Measured conditions for each room</li><li><strong>5</strong> · Mistake: No change procedure · What the owner notices: Site instructions with no record · Fix in the contract: Written variation steps</li></ul><h3>1. Why does “supply and install a sauna” cause disputes?</h3><p><strong>What we see:</strong> a contract line that reads “supply and install sauna, steam room and hammam”, and two parties who disagree on the heater size, the glass front, the lighting and whether the floor drain is included.</p><p><strong>Why it happens:</strong> the scope was written from the room list, without room data. Each side filled the gaps with its own assumptions.</p><p><strong>How we fix it:</strong> we write a room data sheet for each room: inside dimensions, design condition, equipment, materials, lighting, controls and the services each room needs at its boundary. The sheets are attached to the contract.</p><p><strong>How to avoid it:</strong> do not sign a scope that does not reference a data sheet or drawing for every room.</p><h3>2. Why is a stage paid while the room does not work?</h3><p><strong>What we see:</strong> a stage marked complete because the panels are installed, while the heater is not yet connected or the waterproofing has not been tested.</p><p><strong>Why it happens:</strong> stages were defined by activity (“sauna installed”) or by date, not by a step that can be checked.</p><p><strong>How we fix it:</strong> each stage is closed by a test both sides witness: a flood test of the waterproofing before tiling, an electrical test before the heater is energised, a full-condition run before handover.</p><p><strong>How to avoid it:</strong> name the test that closes each stage, and who signs it.</p><figure><img alt="Light timber sauna with slatted two-tier benches on three walls, a wooden bucket on the upper bench, two lamp shades and a thermometer and hygrometer on the back wall" src="https://cdn-images-1.medium.com/max/1024/1*VV9ehMO1JmTWWCGTSbyMdw.jpeg" /></figure><h3>3. What does “two-year warranty” actually cover?</h3><p><strong>What we see:</strong> a leak or a failed generator, and an argument over whether it falls under the warranty.</p><p><strong>Why it happens:</strong> the warranty was written as one line with one period for everything. Workmanship, equipment from a maker and waterproofing behave differently and need different terms.</p><p><strong>How we fix it:</strong> the clause is rewritten by work type. Ours is 24 months on workmanship and manufacturing, 24 months manufacturer’s warranty on electrical and mechanical equipment, and 5 years on structure and waterproofing, on every project, with no conditions added.</p><p><strong>How to avoid it:</strong> ask every bidder to state warranty by work type, and compare them line by line.</p><h3>4. When is a spa room “handed over”?</h3><p><strong>What we see:</strong> a handover meeting that turns into a room-by-room debate about whether the sauna is hot enough or the steam room is steamy enough.</p><p><strong>Why it happens:</strong> the contract never said what a working room is.</p><p><strong>How we fix it:</strong> acceptance criteria are written for each room. A Finnish sauna reaches its set point within the design range of 80–100 °C. A steam room holds 40–50 °C at close to 100 % relative humidity. Each wet room passes its flood test and drains without standing water.</p><p><strong>How to avoid it:</strong> write the criteria into the contract, and agree who measures and with what instrument.</p><h3>5. What happens to changes asked for on site?</h3><p><strong>What we see:</strong> a designer asks on site for a different tile, a moved bench or an extra light. Weeks later nobody agrees whether it was a change, who asked and how it affects time.</p><p><strong>Why it happens:</strong> the contract had no variation procedure, or nobody used it.</p><p><strong>How we fix it:</strong> open changes are listed, each with the person who asked, the date and its effect on time and scope, and agreed in writing.</p><p><strong>How to avoid it:</strong> a short variation clause: written request, written answer with time effect, written approval before work starts. More on how we split roles between the developer and the spa contractor is on our <a href="https://saunadekor.com/spa-contractor-spa-developer/">spa contractor and spa developer</a> page.</p><h3>Frequently asked questions</h3><h3>Should the room data sheets come from the consultant or the contractor?</h3><p>From whoever designs the spa. If that is the contractor, the owner should still review and sign them.</p><h3>Can acceptance criteria be added after signing?</h3><p>Yes, as an agreed addendum. It is easier before work starts.</p><h3>Does the 5-year waterproofing warranty need a maintenance condition?</h3><p>Not with us: it applies on every project.</p><h3>Is a standard construction contract enough for a spa?</h3><p>It can carry the commercial terms. The room data sheets, stage tests and acceptance criteria are spa-specific and need to be attached.</p><h3>Further reading</h3><ul><li><a href="https://en.wikipedia.org/wiki/Construction_contract">Construction contract, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Change_order">Change order, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Warranty">Warranty, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Commissioning">Commissioning, Wikipedia</a></li></ul><p><strong>About the author.</strong> <a href="https://saunadekor.com/products/">Sauna Dekor Spa Solutions</a> · sauna, steam room, hammam and pool manufacturer since 1987 · 40 years of manufacturing in Istanbul · team of 19 · TS EN ISO 9001:2015 · 5,000+ projects in 41+ countries, including 577+ hotel and resort projects · 732 documented references in 32 countries and territories.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=758474963978" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[A Sauna in a Hot-Humid Climate: Five Mistakes Owners Ask Us to Fix]]></title>
            <link>https://medium.com/@saunadekorspasolutions/a-sauna-in-a-hot-humid-climate-five-mistakes-owners-ask-us-to-fix-680d4659182b?source=rss-9a831ade41ce------2</link>
            <guid isPermaLink="false">https://medium.com/p/680d4659182b</guid>
            <category><![CDATA[sauna]]></category>
            <category><![CDATA[home-improvement]]></category>
            <dc:creator><![CDATA[Sauna Dekor Spa Solutions]]></dc:creator>
            <pubDate>Sun, 15 Nov 2026 12:51:36 GMT</pubDate>
            <atom:updated>2026-11-15T12:51:36.077Z</atom:updated>
            <content:encoded><![CDATA[<p><em>Updated: 15 November 2026</em></p><figure><img alt="Corner of a timber sauna in warm orange light with a heater full of stones in a timber guard beside the entrance, light lines along the corners and a control on the side wall" src="https://cdn-images-1.medium.com/max/885/1*YEmLngIAR6w9OFkSG4Yezg.jpeg" /></figure><p><strong>Short answer:</strong> the five sauna mistakes owners in hot, humid climates most often ask Sauna Dekor Spa Solutions to fix are: a vapour foil with open joints and unsealed holes, a sauna shut tight after use so it never dries, benches varnished or oiled “against the humidity”, a control unit fitted in a damp room, and plain steel fixings that rust. All five are about moisture outside the hot room, not about the heat inside it.</p><p>A Finnish sauna runs at 80–100 °C with dry air during use. The problems start in the hours when it is off, when warm, wet outside air or bathroom air meets the cabin and its parts.</p><h3>Which five mistakes come up most often?</h3><ul><li><strong>1</strong> · Mistake: Foil joints and holes not sealed · What the owner notices: Damp wall behind the cabin, musty smell · Fix: Foil taped, every opening sealed</li><li><strong>2</strong> · Mistake: No drying after use · What the owner notices: Dark marks on benches and floor grid · Fix: Door open and extract running after use</li><li><strong>3</strong> · Mistake: Varnished or oiled benches · What the owner notices: Sticky, darkening seats · Fix: Benches sanded back to bare timber</li><li><strong>4</strong> · Mistake: Control unit in a damp room · What the owner notices: Corroded contacts, faults · Fix: Unit moved to a dry, ventilated place</li><li><strong>5</strong> · Mistake: Plain steel fixings · What the owner notices: Rust marks on timber · Fix: Stainless fixings</li></ul><h3>1. What happens when the foil has open joints?</h3><p><strong>What we see:</strong> a damp patch on the wall behind the sauna, a musty smell in the next room and, when the cladding comes off, a wet insulation layer.</p><p><strong>Why it happens:</strong> the foil went up in strips without tape at the joints, and nobody sealed it around the light fittings, the sensor and the heater cable. Moist air passes through every gap and condenses where it meets a cooler surface.</p><p><strong>How we fix it:</strong> cladding comes off, wet insulation is replaced, the foil joints are overlapped and taped, and every opening gets its own seal before the boards go back.</p><p><strong>How to avoid it:</strong> photograph the foil before the cladding goes on. The wall and ceiling layers we use are on our <a href="https://saunadekor.com/sauna-insulation/">sauna insulation</a> page.</p><h3>2. What happens when the sauna is shut tight after use?</h3><p><strong>What we see:</strong> dark spots on the benches and under the floor grid, timber that stays damp for hours, a smell when the door opens next day.</p><p><strong>Why it happens:</strong> the door is closed straight after the last round to “keep the house cool”, and the extract is switched off with the heater. Water from ladles, towels and bodies stays in the timber.</p><p><strong>How we fix it:</strong> the door is left open after use, the extract runs on for a while, and the floor grid is lifted to dry. Where the controller allows it, a short drying run is set after the session.</p><p><strong>How to avoid it:</strong> agree the after-use routine with whoever uses the sauna most, and write it next to the panel.</p><figure><img alt="Glass door with a hinge standing open into a timber sauna with backlit orange stone strips on two walls and two heaters in timber guards on the floor" src="https://cdn-images-1.medium.com/max/1024/1*nRuSousoD9FOlYkcBp-FJA.jpeg" /></figure><h3>3. Why do varnished benches go wrong?</h3><p><strong>What we see:</strong> benches that feel tacky when hot, a surface that darkens in patches and edges where the coating peels.</p><p><strong>Why it happens:</strong> the benches were varnished or oiled to protect them from humidity, the way outdoor furniture is treated. Inside a sauna the coating softens with heat and traps moisture under it.</p><p><strong>How we fix it:</strong> the benches are sanded back to bare timber. Walls can take a product made for sauna interiors if the owner wants one; seats stay bare.</p><p><strong>How to avoid it:</strong> order the benches untreated and follow the timber care in the manual.</p><h3>4. Why does the control unit fail in a damp room?</h3><p><strong>What we see:</strong> a control or power unit that shows faults after a few months, with corrosion on the terminals inside.</p><p><strong>Why it happens:</strong> the unit was fixed in the bathroom next to the shower, or in a cupboard with no air, where humidity stays high all day.</p><p><strong>How we fix it:</strong> the unit moves to a dry, ventilated place within the cable lengths the heater maker allows. We keep spare parts in stock in Istanbul for the equipment we install, so damaged parts are replaced quickly.</p><p><strong>How to avoid it:</strong> place the unit with the electrician before the walls are closed, away from showers and steam.</p><h3>5. Why do fixings rust?</h3><p><strong>What we see:</strong> brown streaks running from screws on the benches, rust on door hinges and on the heater guard brackets.</p><p><strong>Why it happens:</strong> ordinary steel screws and brackets were used, often added on site. In a humid climate, and near the sea, they rust within a season.</p><p><strong>How we fix it:</strong> fixings are replaced with stainless steel, and stained timber is sanded or replaced.</p><p><strong>How to avoid it:</strong> ask for stainless fixings throughout, including anything added on site.</p><h3>Frequently asked questions</h3><h3>Is a sauna a good idea in a humid coastal city?</h3><p>Yes, inside a conditioned house. The cabin itself works the same way; the work is in sealing the build-up and drying the room after use.</p><h3>Should the sauna be heated now and then to dry it out?</h3><p>Leaving the door open with the extract running after each use is usually enough. A short heat-up after long breaks helps the timber dry.</p><h3>Can an outdoor sauna be used in a humid climate?</h3><p>It can, with a roof, a ventilated cladding and a careful seal at the base. Indoor saunas are simpler to keep dry.</p><h3>What warranty is given?</h3><p>24 months on workmanship and manufacturing, 24 months manufacturer’s warranty on electrical and mechanical equipment, and 5 years on structure and waterproofing, on every project.</p><h3>How long does a sauna take to install?</h3><p>About 2 weeks on site for a single sauna, once the room, power and air routes are ready.</p><h3>Further reading</h3><ul><li><a href="https://en.wikipedia.org/wiki/Vapor_barrier">Vapor barrier, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Condensation">Condensation, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Stainless_steel">Stainless steel, Wikipedia</a></li><li><a href="https://en.wikipedia.org/wiki/Finnish_sauna">Finnish sauna, Wikipedia</a></li></ul><p><strong>About the author.</strong> <a href="https://saunadekor.com/products/">Sauna Dekor Spa Solutions</a> · sauna, steam room, hammam and pool manufacturer since 1987 · 40 years of manufacturing in Istanbul · team of 19 · TS EN ISO 9001:2015 · 5,000+ projects in 41+ countries, including 577+ hotel and resort projects · 732 documented references in 32 countries and territories.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=680d4659182b" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>