<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Sergey Romanov on Medium]]></title>
        <description><![CDATA[Stories by Sergey Romanov on Medium]]></description>
        <link>https://medium.com/@serhioromano?source=rss-cf3e92fa5914------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/0*E8nRADi2NMPQPxus.jpg</url>
            <title>Stories by Sergey Romanov on Medium</title>
            <link>https://medium.com/@serhioromano?source=rss-cf3e92fa5914------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Thu, 19 Nov 2026 20:34:32 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@serhioromano/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Маркировка проводов]]></title>
            <link>https://medium.com/eplan4all/%D0%BC%D0%B0%D1%80%D0%BA%D0%B8%D1%80%D0%BE%D0%B2%D0%BA%D0%B0-%D0%BF%D1%80%D0%BE%D0%B2%D0%BE%D0%B4%D0%BE%D0%B2-66863ea16d00?source=rss-cf3e92fa5914------2</link>
            <guid isPermaLink="false">https://medium.com/p/66863ea16d00</guid>
            <category><![CDATA[нумерация-проводов]]></category>
            <category><![CDATA[planes]]></category>
            <category><![CDATA[маркировка]]></category>
            <dc:creator><![CDATA[Sergey Romanov]]></dc:creator>
            <pubDate>Tue, 30 Jul 2024 11:13:45 GMT</pubDate>
            <atom:updated>2024-07-30T11:16:50.322Z</atom:updated>
            <content:encoded><![CDATA[<p>Маркировка проводов, не кажется сложной по началу, или если пользоваться стандартной маркировкой со сквозной нумерацией. Но когда вы купили себе принтер для маркировки, и можете печатать сложные обозначения соединений, тут начинается самое интересное.</p><h4>Проблема печати маркировки</h4><p>Ограничение длинны марки. Я печатаю на марках, 4х12мм.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*M88DTInKO1Tpm9qWNvY8bg.jpeg" /></figure><p>Таким образом я не могу чтобы длинна обозначения соединения была больше, чем 11 символов. И даже 11 символов, уже слишком мелко. А использовать марки 4х18мм я тоже не могу, так как из-за постоянной экономии места, расстояние между изделием и кабель-каналом не всегда больше 20мм.</p><h4>Обратная маркировка</h4><p>Сначала я просто создал маркировку типа <strong>89:SF1:UZ1</strong>. Я называю ее обратной маркировкой. <strong>89</strong> — это сквозная нумерация, <strong>SF1</strong> — источник соединения, <strong>UZ1</strong> — цель соединения. Как видите тут уже 10 символов. А если любая из 3-х нумераций увеличится на один разряд, то я выхожу за пределы. Так же это оказалось не всегда информативно. Хотя это было уже на много лучше, чем просто сквозная нумерация.</p><h4>Маркировка</h4><p>Я использую сложную маркировку, и маркирую разные цепи по разным принципам.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/836/1*r2gaUuahM2Eu4iUkPu9ZOQ.png" /></figure><p>Давайте по порядку рассмотрим все правила маркировки.</p><h4><strong>N</strong> и <strong>PE</strong></h4><p>Это правила для одноименных потенциалов. Эти правила исполняются первыми и все марки этих потенциалов маркируют как <strong>N </strong>и <strong>PE </strong>соответственно.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/247/1*FUrtDgMPw6VykPZPPk4Qlg.png" /><figcaption>Пример маркировки <strong>N</strong> и <strong>PE</strong></figcaption></figure><p>Для того чтобы это заработало, нужно вывод потенциала добавить в группу <strong>N </strong>или <strong>PE. </strong>Это правило работает не на потенциал, а на группу соединений. Не обязательно назначать группу каждому соединению, а можно просто назначить группу на вывод потенциала, или на определение потенциала.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*lGsElLvO2eneDyBoBpzb_g.png" /></figure><p>Ну или если вы не пользуетесь на схеме потенциалами, можно назначить группу на сами обозначения соединения.</p><blockquote>Напомню, чтобы добавить соединение в группу, нужно в свойствах соединения 31069 или выбрать, если ранее уже использовалось, или просто вписать любое новое имя группы.</blockquote><h4>Силовой</h4><p>Это правило маркирует провода, которым присвоена группа <strong>силовой</strong>. Пример марки <strong>L1:QF2:1</strong>.</p><p><strong>L1 </strong>— Имя потенциала, <strong>QF2 </strong>— Источник соединения,<strong> 1 </strong>— нумерация на каждое устройство отдельная. Я очень редко этим пользуюсь примера не нашел показать.</p><h4>ПЛК</h4><p>Соединения, прикрепленные к ПЛК, я нумерую, например так <strong>D3:DO5</strong>.</p><p><strong>D3</strong> — это ОУ ПЛК или модуля, <strong>DO5 </strong>— описание вывода.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*5rMqK9jUhvHO2bp99ZCiTQ.png" /><figcaption>Пример обозначения соединения подключённого к ПЛК</figcaption></figure><p>С группой ПЛК еще нужно поработать, так как бывает ситуации, когда на нескольких выводах, описание вывода одинаковое.</p><h4>L+ и L-</h4><p>Потенциалы постоянного тока я маркирую по одинаковым правилам. Сначала нумерация сквозная через весь проект, а потом имя потенциала. Например, <strong>1-0V</strong>, <strong>3-24V</strong>, …</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*L_PEJtT2J554ga1s3LZcnw.png" /></figure><p>Это правило применятся к одноименной группе L+ и L-, поэтому на схеме нужно обязательно поставить точки определения потенциала на выходе блока питания (1) и присвоить им имя группы (3) и имя потенциала(2).</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/919/1*tpFD9PpNSi7fsT8vES4mLQ.png" /></figure><p>В дополнение обозначения соединения, которые размещаются сразу на выходе блока питания, я нумерую <strong>0V</strong> и <strong>24V</strong> и помечаю как установлены вручную, чтобы им не присваивался счетчик, а только на соединения после устройств. Но это не обязательно.</p><h4>L</h4><p>Это правило применяется ко всем обозначениям соединении добавленных в группу <strong>L</strong>. Его я использую для нумерации силовых цепей. Примеров марки может быть 2.</p><ol><li><strong>L1–1</strong>, <strong>L1–2</strong>, <strong>L3–1</strong>, … Первое это имя потенциала, а потом счетчик. Счетчик сбрасывается на каждый потенциал.</li></ol><figure><img alt="" src="https://cdn-images-1.medium.com/max/480/1*TDN8MAnO0x9kqYluDQzSTQ.png" /></figure><p>На примере видно, что у меня стоят точки определения потенциалов (1). Там видно и имя потенциала. Обозначения соединения принимают имя этого потенциала и счетчик на каждый потенциал отдельный.</p><p>2. Второй пример это <strong>M1-L1–1</strong>. Это тот же самый счетчик, но мы еще добавляем ОУ целевого устройства в самом начале.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/722/1*GaTM_8q5j_QkQYHbGbNf9g.png" /></figure><p>Использую, маркируя силовые цепи моторов или исполнительных устройств.</p><p>Такая маркировка получается если соединение находится внутри местоположения, где есть подидентификатор у функционального назначения. Это я объясню далее.</p><h4>Мотор</h4><p>Для силовых и управляющих цепей управления двигателем у меня отдельная группа <strong>мотор</strong>. По госту они маркируются примерно так 1–1, 1–2, 2–1, 2–3, … где первая цифра это группа управляющих соединений, например на мотор один, а второй номер, это номер соединения в группе. Но так как мы теперь можем печатать маркировку, я подумал, что будет лучше если вместо первого номера я размещу ОУ устройства, которым мы управляем. Например <strong>M1–1</strong>, <strong>M1–2</strong>, …</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/790/1*XBQ8jSmHr_7dHKOz0J-EtQ.png" /></figure><p>Но для подобной реализации потребовалось немного больше настроек в проекте.</p><p>(1) Соединения должны находиться в местоположении с подидентификатором для функционального назначения. Именно подгруппа используется в обозначении соединения. Как мы видим на примере у нас местоположение <strong>=М1.М13 </strong>(1)<strong> </strong>где <strong>М13 </strong>это подгруппа и именно это используется в обозначении соединения (2) (3).</p><p>(2) Соединения с группой <strong>L </strong>описанной выше. Если соединения с группой L попадают в местоположение с подидентификатором для функционального назначения, то они выглядят именно так.</p><p>(3) Соединения, объединённые группой <strong>мотор</strong>.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*q2MAMwcmm0xuTOAYNwccxg.png" /></figure><p>Почему подидентификатор? Найти цель передвигаясь по лестнице оказалось достаточно сложной задачей, потому что не понятно сколько устройств нужно пройти. Я просто размещаю местоположение, делаю его срытым. Идентификаторы Функционального Назначения я делаю описывающими что бы они не влияли на структуру.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/935/1*Y5MjZrNN3Cl0T5vAiAyxfg.png" /></figure><p>У меня есть основной идентификатор функционального назначения <strong>М</strong>. Его я использую для всех подидентификаторов. Для того чтобы ввести новый подидентификатор, нужно просто руками его прописать через точку.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/936/1*bccOfSlBATXXickB_xIR2A.png" /></figure><h4>Клеммы</h4><p>Соединения, подключенные к клеммам, но еще не пронумерованные предыдущими правилами я нумерую просто по ОУ клеммника и номеру клеммы. Например <strong>XT1–1</strong>.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/614/1*SWo1EdDGxm5Cfu07OGGBxw.png" /><figcaption>Пример нумерации подключения к клеммнику</figcaption></figure><h4>Основная</h4><p>Ну и последнее правило, применятся ко всем соединениям которые не обработаны предыдущими правилами, и это то, что я в самом начале назвал обратной маркировкой типа <strong>89:SF1:UZ1</strong>.</p><h3>Скачать</h3><p>В моей папке <a href="https://1drv.ms/f/s!AoZIPjc0O6zHjbFIKNvQ2fNnARem8w">EPLAN</a> найдите файл <em>WN.SR_WithPotential.xml</em> и импортируйте как новый тип маркировки.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/887/1*GgAD_ledpJB60Azes3dlow.png" /></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=66863ea16d00" width="1" height="1" alt=""><hr><p><a href="https://medium.com/eplan4all/%D0%BC%D0%B0%D1%80%D0%BA%D0%B8%D1%80%D0%BE%D0%B2%D0%BA%D0%B0-%D0%BF%D1%80%D0%BE%D0%B2%D0%BE%D0%B4%D0%BE%D0%B2-66863ea16d00">Маркировка проводов</a> was originally published in <a href="https://medium.com/eplan4all">EPLAN4ALL</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Форма отчета F11 схема подключения клемм V2]]></title>
            <link>https://medium.com/eplan4all/%D1%84%D0%BE%D1%80%D0%BC%D0%B0-%D0%BE%D1%82%D1%87%D0%B5%D1%82%D0%B0-f11-%D1%81%D1%85%D0%B5%D0%BC%D0%B0-%D0%BF%D0%BE%D0%B4%D0%BA%D0%BB%D1%8E%D1%87%D0%B5%D0%BD%D0%B8%D1%8F-%D0%BA%D0%BB%D0%B5%D0%BC%D0%BC-v2-b7b7f34c2090?source=rss-cf3e92fa5914------2</link>
            <guid isPermaLink="false">https://medium.com/p/b7b7f34c2090</guid>
            <category><![CDATA[отчеты]]></category>
            <category><![CDATA[planes]]></category>
            <dc:creator><![CDATA[Sergey Romanov]]></dc:creator>
            <pubDate>Tue, 30 Jul 2024 06:10:54 GMT</pubDate>
            <atom:updated>2024-07-30T06:10:54.188Z</atom:updated>
            <content:encoded><![CDATA[<p>Как я уже много раз упоминал в разных статьях, форумах и чатах, я проектирую под страницы А4 и стараюсь чтобы все типы страниц были этого формата. Не все у меня получалось сделать на А4, но вот недавно я перевел форму F11 на этот формат, и должен вам сказать я очень доволен тем, что получилось.</p><h4>Основные изменения</h4><p>Естественно, новая форма разместилась на рамке А4. Для этого я нарисовал рамку, потому что горизонтальных рамок А4 я не нашел. Позже кто-то упоминал, что ЕСКД не предусматривает рамки А4 альбомного типа. Но мне “пофиг”. Я хочу А4, я сделал А4.</p><p>Я перешел на шрифты не ГОСТ. Мне честно сказать они порядком надоели, с ними были проблемы при экспорте в PDF или с отображением верхнего индекса как мм².</p><p>Теперь я использую как первый шрифт Open Sans Condensed Light и второй Oswald Light.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*MG-gj1dv0UAAO4UwHnB-Zg.png" /></figure><p>Именно под них все формы у меня адаптированы и с ними они будут выглядеть лучше всего.</p><p>Я увеличил размеры всех шрифтов. Последнее время мое зрение уже не то, и я понял как неудобно старикам, которым и я становлюсь, пользоваться моей формой. Даже в очках иногда тяжело увидеть мелкие шрифты. Так что на этой форме, все так увеличено, чтобы люди в очках, могли все хорошо видеть.</p><h4>По пунктам</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*6Dgc9OlewSwF4fVdhjpWeg.png" /><figcaption>Новая форма отчета</figcaption></figure><ol><li>Добавил легенду для мостовых перемычек и проволочных перемычек.</li><li>Исправил отображение обозначения соединения для внутренних подключений.</li><li>Основной проблемой было то, что я долго не мог справиться с тем, что некоторые клеммы разъезжались.</li></ol><figure><img alt="" src="https://cdn-images-1.medium.com/max/783/1*btHllF-x9lTLUVx3nQq5oQ.png" /></figure><p>Мне было не понятно, как это избежать. Но посвятив несколько часов, методом “тыка”, перебирая все параметры, я всё-таки нашел нужный и исправил это.</p><p>4. Отображение мостовых перемычек теперь сверху и его видно на много лучше.</p><p>5. Отображение проволочных перемычек выделено другим цветом.</p><p>6. Графика для особых типов клемм. Например, клемма с предохранителем, или разъединяющая клемма, и т.д.</p><p>7. Описание подключаемого устройства теперь вертикально. Это дет больше места. Если устройства всего 2 клеммы, его ширина не позволяла нормально отображать текст.</p><p>Скачать форму, рамку и шрифты можно в моей общей папке <a href="https://1drv.ms/f/s!AoZIPjc0O6zHjbFIKNvQ2fNnARem8w?e=bUi2RZ">EPLAN</a>.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=b7b7f34c2090" width="1" height="1" alt=""><hr><p><a href="https://medium.com/eplan4all/%D1%84%D0%BE%D1%80%D0%BC%D0%B0-%D0%BE%D1%82%D1%87%D0%B5%D1%82%D0%B0-f11-%D1%81%D1%85%D0%B5%D0%BC%D0%B0-%D0%BF%D0%BE%D0%B4%D0%BA%D0%BB%D1%8E%D1%87%D0%B5%D0%BD%D0%B8%D1%8F-%D0%BA%D0%BB%D0%B5%D0%BC%D0%BC-v2-b7b7f34c2090">Форма отчета F11 схема подключения клемм V2</a> was originally published in <a href="https://medium.com/eplan4all">EPLAN4ALL</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Форма отчета F11 — Схема подключения клемм]]></title>
            <link>https://medium.com/eplan4all/%D1%84%D0%BE%D1%80%D0%BC%D0%B0-%D0%BE%D1%82%D1%87%D0%B5%D1%82%D0%B0-f11-%D1%81%D1%85%D0%B5%D0%BC%D0%B0-%D0%BF%D0%BE%D0%B4%D0%BA%D0%BB%D1%8E%D1%87%D0%B5%D0%BD%D0%B8%D1%8F-%D0%BA%D0%BB%D0%B5%D0%BC%D0%BC-9ccb869783d4?source=rss-cf3e92fa5914------2</link>
            <guid isPermaLink="false">https://medium.com/p/9ccb869783d4</guid>
            <category><![CDATA[клеммник]]></category>
            <category><![CDATA[planes]]></category>
            <category><![CDATA[отчеты]]></category>
            <category><![CDATA[eplan-p8]]></category>
            <category><![CDATA[проектирование]]></category>
            <dc:creator><![CDATA[Sergey Romanov]]></dc:creator>
            <pubDate>Fri, 02 Mar 2018 10:12:05 GMT</pubDate>
            <atom:updated>2018-03-02T10:12:05.723Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*PYSJLdzk-TAWOgwf_3hX6A.png" /></figure><h3>Форма отчета F11 — Схема подключения клемм</h3><p>В продолжение темы, отчетов подключения клемм <a href="https://medium.com/eplan4all/%D0%BF%D1%80%D0%B8%D1%81%D0%B2%D0%BE%D0%B5%D0%BD%D0%B8%D0%B5-%D0%B3%D1%80%D0%B0%D1%84%D0%B8%D0%BA%D0%B8-%D1%81%D0%B2%D0%BE%D0%B9%D1%81%D1%82%D0%B2%D0%B0%D0%BC-%D0%BA%D0%BB%D0%B5%D0%BC%D0%BC%D1%8B-%D0%BD%D0%B0-%D0%BF%D1%80%D0%B8%D0%BC%D0%B5%D1%80%D0%B5-%D0%BE%D1%82%D1%87%D0%B5%D1%82%D0%B0-f11-%D1%81%D1%85%D0%B5%D0%BC%D0%B0-%D0%BF%D0%BE%D0%B4%D0%BA%D0%BB%D1%8E%D1%87%D0%B5%D0%BD%D0%B8%D1%8F-%D0%BA%D0%BB%D0%B5%D0%BC%D0%BC-747cf82ba574">начатой тут</a>.</p><p>Отчет схемы подключения клемм является важным исполнительным документом для монтажников. Его можно выполнить так, чтобы у монтажника не оставалось вопросов по подключению. Но его можно выполнить и красиво, с применением графики.</p><p>Честно сказать, этот отчет, одна из основных причин повлиявших на мое окончательное решение перейти с <strong>AutoCAD Electrical</strong> на <strong>EPLAN Electric P8</strong>. Если бы у меня была такая форма подключения, когда я только начинал и осуществлял электромонтаж и пуско-наладку объектов, и только учился читать схемы, думаю я все понял намного быстрей.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*PIM_uOo6qO8bHACJj-r16w.png" /></figure><p>Будет очень приятно работать с подобным отчетом, напечатанном в цвете.</p><h4>Описание</h4><p>Данный отчет идет в комплекте с EPLAN под номером 006 (F11_006.f11). Предложная мной версия немного доработана.</p><ol><li>Создана версия А3+ для длинных подключений</li><li>Добавлена нумерация проводов внутренних подключений</li><li>Добавлена и улучшена отображение номера клемника</li><li>Добавлено описание подключаемого устройства как составной текст из Функционального текста, Примечания и Технических параметров.</li><li>Много мелких правок и улучшений.</li></ol><p>Скачать <a href="https://s3.amazonaws.com/serhioromano/PublicDownloads/asublog/SR_F11.zip">SR_F11.zip</a></p><p>В состав архива входят 2 файла формы, и 2 рамки. Одна А3 и одна А3+.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=9ccb869783d4" width="1" height="1" alt=""><hr><p><a href="https://medium.com/eplan4all/%D1%84%D0%BE%D1%80%D0%BC%D0%B0-%D0%BE%D1%82%D1%87%D0%B5%D1%82%D0%B0-f11-%D1%81%D1%85%D0%B5%D0%BC%D0%B0-%D0%BF%D0%BE%D0%B4%D0%BA%D0%BB%D1%8E%D1%87%D0%B5%D0%BD%D0%B8%D1%8F-%D0%BA%D0%BB%D0%B5%D0%BC%D0%BC-9ccb869783d4">Форма отчета F11 — Схема подключения клемм</a> was originally published in <a href="https://medium.com/eplan4all">EPLAN4ALL</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Как определить качественный НШВИ?]]></title>
            <link>https://serhioromano.medium.com/%D0%BA%D0%B0%D0%BA-%D0%BE%D0%BF%D1%80%D0%B5%D0%B4%D0%B5%D0%BB%D0%B8%D1%82%D1%8C-%D0%BA%D0%B0%D1%87%D0%B5%D1%81%D1%82%D0%B2%D0%B5%D0%BD%D0%BD%D1%8B%D0%B9-%D0%BD%D1%88%D0%B2%D0%B8-9aa0a97bae42?source=rss-cf3e92fa5914------2</link>
            <guid isPermaLink="false">https://medium.com/p/9aa0a97bae42</guid>
            <category><![CDATA[ншви]]></category>
            <category><![CDATA[опресовка-наконечников]]></category>
            <category><![CDATA[обжим-проводов]]></category>
            <dc:creator><![CDATA[Sergey Romanov]]></dc:creator>
            <pubDate>Thu, 25 Jan 2018 11:46:57 GMT</pubDate>
            <atom:updated>2018-01-25T11:46:57.872Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*Ived024EZ-SjCvzXW_A0bA.jpeg" /></figure><p>Или есть разница в качестве китайских наконечников без имени и фирменных.</p><p>Тема обжима проводов теряет свою популярность или так сказать новизну. Мое <a href="https://www.youtube.com/watch?v=h-u7S_-8u9U">видео</a> на эту тему снятое 3 года назад достигло 250 000 просмотров. Но по комментариям понятно, что это уже не новшество, а необходимый минимум, о котом всем все известно. Многие уже даже не видят смысла зачем об этом говорить, ведь это очевидно.</p><p>Я думаю теперь можно поднять новую тему. Это качество наконечников. Давайте я попытаюсь сравнить дешевый китайский НШВИ, без имени и фирменный наконечник Klemsan.</p><h3>Толщина</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*ytWRbYXIenPo2MJtJBhMtw.jpeg" /><figcaption>С лева Китай, с права Klemsan</figcaption></figure><p>Первое что мы видим не вооруженным глазом что наконечник Klemsan заметно толще. Ни знаю на сколько это важно и повлияет на качество соединения, но приятно знать что производитель не пожалел меди, на наконечник которым ты пользуешься.</p><p>Но для кольцевых или вилочных наконечников, толщина может являться очень важным параметром.</p><h3>Покрытие</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*J9ChQZc3gs_k0vKnwb5hUg.jpeg" /></figure><p>Обратите внимание что наконечник слева (Китай), имеет больше блеска чем наконечник с права. Скорей всего это не лужение а может даже просто гальваника. А если и лужение, то там явно не так много олова. Ведь олово, со временем темнеет и мутнеет. Так что если наконечник не такой блестящий, это не недостаток, а наоборот достоинство.</p><p>Данная фича является реальным превосходством, которое реально повлияет на качество контакта.</p><h3>Материал</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*cZZCSwEoYSM8_wjKAo6TVQ.jpeg" /></figure><p>Ну и последние — это из чего изготовлен наконечник. После обработки надфилем, отчетливо видно, что Китайский наконечник сделан из сплава больше похожего на латунь, с небольшим содержанием меди. А вот фирменный наконечник Klemsan очевидно сделан из меди.</p><p>Это тоже является реальным превосходством которое на прямую повлияет на качество контакта.</p><h3>Заключение</h3><p>Качественный наконечник стоит не на много дороже. Но увеличивает качество и долговечность соединения в разы.</p><p>Ну вот и все. Покупайте только качественные расходники!</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=9aa0a97bae42" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Ресурсы]]></title>
            <link>https://medium.com/eplan4all/%D1%80%D0%B5%D1%81%D1%83%D1%80%D1%81%D1%8B-2a77176d33ec?source=rss-cf3e92fa5914------2</link>
            <guid isPermaLink="false">https://medium.com/p/2a77176d33ec</guid>
            <category><![CDATA[eplan-p8]]></category>
            <dc:creator><![CDATA[Sergey Romanov]]></dc:creator>
            <pubDate>Wed, 03 Jan 2018 11:56:48 GMT</pubDate>
            <atom:updated>2024-07-30T06:15:58.297Z</atom:updated>
            <content:encoded><![CDATA[<blockquote>Статья регулярно обновляется</blockquote><p><a href="https://www.eplan-russia.ru/ru/glavnaja/">Официальный сайт компании <strong>EPLAN Software &amp; Service </strong>в России</a></p><h3>Ресурсы</h3><ul><li><a href="https://kipservis.ru/eplan">https://kipservis.ru/eplan</a> — Библиотеки</li></ul><h3>Форумы</h3><ul><li><a href="http://asutpforum.ru/viewforum.php?f=78">http://asutpforum.ru</a></li></ul><h3>Блоги</h3><ul><li><a href="https://medium.com/eplan4all">Eplan4All</a></li></ul><h3>Видео</h3><ul><li>Видео канал <a href="https://www.youtube.com/user/eplan4all">Андрея Горского</a></li><li>Видео канал <a href="https://www.youtube.com/channel/UCjOe1p3NX9C4kEKm7EuodxA">Александра Павлов</a>а</li><li>Видео канал <a href="https://www.youtube.com/user/ivanovme">Иванова Максима</a> (RIP)</li><li>Видео канал <a href="https://www.youtube.com/channel/UCMO_PvgUsbDQqj297NAUExA/feed">Максим Рубликов</a></li></ul><h3>Сообщества</h3><ul><li>Группа телеграмм <a href="https://t.me/EplanRussia">https://t.me/EplanRussia</a></li><li>Группа вк <a href="https://vk.com/club84711857">Обучалка по EPLAN</a></li><li>Группа вк <a href="https://vk.com/club3505907">Клуб Любителей Eplan</a></li></ul><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=2a77176d33ec" width="1" height="1" alt=""><hr><p><a href="https://medium.com/eplan4all/%D1%80%D0%B5%D1%81%D1%83%D1%80%D1%81%D1%8B-2a77176d33ec">Ресурсы</a> was originally published in <a href="https://medium.com/eplan4all">EPLAN4ALL</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Форма отчета F02 Групповая спецификация изделий и группировка записей формы]]></title>
            <link>https://medium.com/eplan4all/%D1%84%D0%BE%D1%80%D0%BC%D0%B0-%D0%BE%D1%82%D1%87%D0%B5%D1%82%D0%B0-f02-%D0%B3%D1%80%D1%83%D0%BF%D0%BF%D0%BE%D0%B2%D0%B0%D1%8F-%D1%81%D0%BF%D0%B5%D1%86%D0%B8%D1%84%D0%B8%D0%BA%D0%B0%D1%86%D0%B8%D1%8F-%D0%B8%D0%B7%D0%B4%D0%B5%D0%BB%D0%B8%D0%B9-%D0%B8-%D0%B3%D1%80%D1%83%D0%BF%D0%BF%D0%B8%D1%80%D0%BE%D0%B2%D0%BA%D0%B0-%D0%B7%D0%B0%D0%BF%D0%B8%D1%81%D0%B5%D0%B9-%D1%84%D0%BE%D1%80%D0%BC%D1%8B-b06c1a3dc2f9?source=rss-cf3e92fa5914------2</link>
            <guid isPermaLink="false">https://medium.com/p/b06c1a3dc2f9</guid>
            <category><![CDATA[проектирование]]></category>
            <category><![CDATA[planes]]></category>
            <category><![CDATA[автоматизация]]></category>
            <category><![CDATA[отчеты]]></category>
            <category><![CDATA[eplan-p8]]></category>
            <dc:creator><![CDATA[Sergey Romanov]]></dc:creator>
            <pubDate>Fri, 22 Dec 2017 18:13:48 GMT</pubDate>
            <atom:updated>2017-12-24T18:06:33.790Z</atom:updated>
            <content:encoded><![CDATA[<blockquote>Тем для кого создание формы F02 является обычным делом, статью не читать.</blockquote><h3>Как я до этого докатился</h3><p>Когда я только начинал работать в EPLAN, я вообще не пользовался изделиями. Просто размещал устройства, рисовал схему, и создавал отчет <em>F11 - Список устройств</em>, где через свойство устройства<em>&lt;20045&gt; Примечание</em> или <em>&lt;20031&gt; Функциональный текст</em> описывал назначение устройства.</p><p>Конечно при этом у меня не было необходимости формировать Спецификацию изделий. Я их подбирал позже, по месту. Например я запроектировал устройство автомат на 2А (С2), а когда шел его покупать уже на месте решал купить мне CHINT, EKF, или ABB, в зависимости от требований и амбиций заказчика.</p><p>Конечно для многих такой способ не допустим, и требования диктуют что бы все устройства были привязаны к конкретным изделиям, и если вы такой человек, остановитесь и не читайте дальше. Вам не будет интересно. Но для малого бизнеса как мой это было вполне приемлемо. Тем более, что базы на устройства особо и не было, а создавать ее занимает время, которое не хочется тратить, особенно в начале, когда даже тривиальные задачи иногда решаешь избыточное количество времени.</p><p>Но время идет, и нужно двигаться вперед. Как говориться “Глаза бойся — руки делай”</p><p>Потихоньку я стал создавать изделия в базе, назначать их устройствам. Оказалось не так то и много изделий которыми я пользуюсь. Очень много из них почти идентичны и их можно создавать копированием с минимальными временными затратами. Короче было страшней чем оказалось.</p><h4>Если вы еще не создаете форму F02, вот почему вам надо начать!</h4><p>Начав закладывать изделия в процесс проектирования Щитов Управления, я могу генерировать отчет спецификации изделий. Это дает мне преимущества.</p><ol><li>Список покупок создается автоматически. Мне не надо по схеме сидеть и считать чего, сколько купить, как я это делал раньше.</li><li>Заказчик сразу видит, какие изделия будут стоять у него в щите, и может сразу высказаться по этому поводу.</li><li>Если у меня есть изделия, то я могу перейти к следующему шагу совершенствования навыков EPLAN, и начать создавать монтажные схемы в 3Д и 2Д. Как следствие использовать автоматическую трассировку проводов, что может в разы повысить качество сборки, и ускорить процесс сборки, что как следствие скажется на общих прибылях что с лихвой окупит время вложенное на создание базы изделий и создание монтажной схемы. Советую <a href="https://medium.com/eplan4all/%D0%BB%D0%B8%D1%87%D0%BD%D1%8B%D0%B9-%D0%BE%D0%BF%D1%8B%D1%82-%D0%BF%D1%80%D0%B8%D0%BC%D0%B5%D0%BD%D0%B5%D0%BD%D0%B8%D1%8F-eplan-propanel-%D0%BD%D0%B0-%D0%BF%D1%80%D0%B0%D0%BA%D1%82%D0%B8%D0%BA%D0%B5-704697000402">почитать об этом тут</a>.</li><li>Для меня открылся новый пласт клиентов. Так как подобный способ проектирования считается стандартом, то я могу начать работать с организациями, которые требуют документацию к Щиту по ГОСТ. А это как правило самые платежеспособные организации.</li><li>Уровень доверия и уважения ко мне как к профессионалу возрос со стороны клиентов. Это очень круто для нашего рынка. Тут и схему не всегда приложат к щиту. А тут такой пакет документов. Людям приятно, а мне не напряжно.</li></ol><h3>Форма F02</h3><p>Сначала я создал форму спецификации изделий, самостоятельно. Мне не понравилась огромная стандартная форма на листе А3, и я решил сделать свою маленькую на листе А4. Так как требований соблюдать ГОСТ ко мне пока не было, она отлично работала. Все что мне нужно было это сформировать список покупок, и показать клиенту что я планирую поставить в щит.</p><p>Скачайте ее тут: <a href="https://s3.amazonaws.com/serhioromano/PublicDownloads/asublog/SR_F02_A4.zip">SR_F02_A4.zip</a></p><p>Используйте с ней рамку А4 для следующих страниц. Выглядела она примерно вот так.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/761/1*SxuLka0fHiYzV67v02h_gg.jpeg" /></figure><p>Мне было удобно сделать группировку по категориям изделий, думаю и вам так будет удобно, но если вы захотите поменять, то я опишу как это сделать ниже.</p><p>Когда я начал писать эту статью, понял что для многих, эта форма будет абсолютно бесполезна, так как большинству требуется стандартные формы по ГОСТ.</p><p>Вот так советуется оформлять форму спецификации по <a href="http://cadsupport.ru/downloads/GOST21.110-213.pdf">ГОСТ 21.110–2013</a>.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*55bbtxqiDvcQT9gDGFRPWA.png" /><figcaption>Спецификация изделий по ГОСТ 21.110</figcaption></figure><p>Почему советуется? Согласно пункта 4.1</p><blockquote><strong>Допускается модифицировать</strong> форму спецификации, например, включать в нее дополнительные графы, изменять размеры граф (кроме размеров граф основной надписи и дополнительных граф к ней), в соответствии с требованиями, установленными в стандартах организаций.</blockquote><p>Главное что бы форма содержала следующие графы.</p><ul><li><strong>Код продукции</strong> — код продукции (оборудования, изделия, материала) по классификатору продукции страны — разработчика рабочей документации*. Если в стандартах, технических условиях, каталогах и др. документах на продукцию отсутствует информация по кодам продукции, то эту графу не заполняют;</li><li><strong>Поставщик</strong> — наименование (адрес) изготовителя или поставщика оборудования (для импортного оборудования — страну, фирму);</li><li><strong>Ед. измерения</strong> — обозначение единицы измерения;</li><li><strong>Кол</strong>. — количество оборудования, изделий, материалов:</li><li><strong>Масса 1 ед., кг</strong> — массу единицы оборудования, изделия в килограммах. Допускается для тяжелого оборудования указывать массу в тоннах. Для оборудования или изделия массой до 25 кг, не требующего при монтаже применения подъемно-транспортных средств, графу допускается не заполнять;</li><li><strong>Примечание</strong> — дополнительные сведения.</li></ul><p>И так я создал следующую форму. Эта форма уже создана по ГОСТ и выглядит примерно вот так.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*3KLLn8xqTtSaX6jjuQtKUA.jpeg" /></figure><p>Так как EPLAN хранит на много больше полезной информации чем требует для отображения ГОСТ, я добавил новые колонки, и использовал свой шифр в примечании для определения позиции изделия на схеме. Вот отличия помеченные на рисунке.</p><ol><li>Добавил графику обозначения устройства. Зачем? Ни знаю, просто красиво смотрится. Просто потому что EPLAN это может.</li><li>Добавил номер типа изделия. Эта информация содержит более расширенные данные об изделии. По крайней мере в базе которую создаю для себя я.</li><li>Сначала я поставил в примечание само свойство <em>&lt;20045&gt; Примечание. </em>Но оно бесполезно в этом типе отчета, и создает бардак. Я решил разместить здесь свой шифр. Например: ЩУ:15.5. Вот как легко расшифровать код: [Установка]:[Имя страницы].[Номер колонки]</li></ol><p>Эта форма так же имеет возможность группировки товара по какому то признаку.</p><blockquote>ВАЖНО! Что бы группировка заработал, при создании отчета, нужно присвоить сортировку по свойству &lt;22041&gt; Группа продуктов</blockquote><figure><img alt="" src="https://cdn-images-1.medium.com/max/833/1*20H3DxAxrgZEfe61woKzJQ.jpeg" /></figure><p>Скачать отчет можно тут: <a href="https://s3.amazonaws.com/serhioromano/PublicDownloads/asublog/SR_F02_A3.zip">SR_F02_A3.zip</a></p><p>Данный пакет включает в себя 4 файла.</p><ul><li><strong>SR_F02_A3_GOST.f02</strong> - Форма отчета для первой страницы. Именно ее вы должны выбрать при создании отчета.</li><li><strong>SR_F02_A3_GOST_next.f02</strong> - Форма отчета для последующих страниц</li><li><strong>SR_A3_CПДС_Текс_Первая.fn1</strong>- Рамка для первой страницы отчета. Эти рамки отличаются тем что у них нет колонок, и они сделаны для текстовой информации.</li><li><strong>SR_A3_CПДС_Текс_Следующая.fn1</strong>- Рамка для последующих страниц.</li></ul><h3>Как сменить группировку</h3><p>Возможно вас не устроит группировка по группе изделия и вы захотите ее изменить, например на поставщика, или место установки. Для этого откройте форму <strong>SR_F02_A3_GOST.f02 </strong>и<strong> SR_F02_A3_GOST_Next.f02 </strong>на редактирование через.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/760/1*fTD_wtUt5kUeNuah39Iwtw.jpeg" /></figure><p>И в динамической области заголовка смените свойство текста (помечено зеленым) на то, по которому вы хотите группировать.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*_0dUUtDFjJMhK27EuKgoNA.jpeg" /></figure><p>Теперь в сортировке используйте тоже свойство для сортировки.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/833/1*20H3DxAxrgZEfe61woKzJQ.jpeg" /></figure><p>Это основной принцип. Нужно что бы текст который выводит имя свойства в заголовке и свойство сортировки совпадали.</p><h3>Как это работает</h3><p>Ну и если вам еще интересно как это сделано, вот куда копать. Обратите внимание на свойство &lt;13060&gt; в окне свойств формы</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/826/1*4dhEnigCif_5AipDUCYpcA.jpeg" /><figcaption>Окно свойств формы</figcaption></figure><p>Здесь мы устанавливаем глубину вложенности. Можно создавать и более сложные группировки, но в нашем случае 1 достаточно.</p><p>Если мы присвоим сортировку, при создании отчета проекта, то когда значение этого свойства, будет меняться, форма создаст новый заголовок. Все что нам осталось, в динамической области заголовка, на форме, вывести текст соответствующий свойству по которому мы сортируем.</p><p>Вот и все. Удачи.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=b06c1a3dc2f9" width="1" height="1" alt=""><hr><p><a href="https://medium.com/eplan4all/%D1%84%D0%BE%D1%80%D0%BC%D0%B0-%D0%BE%D1%82%D1%87%D0%B5%D1%82%D0%B0-f02-%D0%B3%D1%80%D1%83%D0%BF%D0%BF%D0%BE%D0%B2%D0%B0%D1%8F-%D1%81%D0%BF%D0%B5%D1%86%D0%B8%D1%84%D0%B8%D0%BA%D0%B0%D1%86%D0%B8%D1%8F-%D0%B8%D0%B7%D0%B4%D0%B5%D0%BB%D0%B8%D0%B9-%D0%B8-%D0%B3%D1%80%D1%83%D0%BF%D0%BF%D0%B8%D1%80%D0%BE%D0%B2%D0%BA%D0%B0-%D0%B7%D0%B0%D0%BF%D0%B8%D1%81%D0%B5%D0%B9-%D1%84%D0%BE%D1%80%D0%BC%D1%8B-b06c1a3dc2f9">Форма отчета F02 Групповая спецификация изделий и группировка записей формы</a> was originally published in <a href="https://medium.com/eplan4all">EPLAN4ALL</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Автоматическое присвоение жил кабелей с потенциалом PE/SH]]></title>
            <link>https://medium.com/eplan4all/%D0%B0%D0%B2%D1%82%D0%BE%D0%BC%D0%B0%D1%82%D0%B8%D1%87%D0%B5%D1%81%D0%BA%D0%BE%D0%B5-%D0%BF%D1%80%D0%B8%D1%81%D0%B2%D0%BE%D0%B5%D0%BD%D0%B8%D0%B5-%D0%B6%D0%B8%D0%BB-%D0%BA%D0%B0%D0%B1%D0%B5%D0%BB%D0%B5%D0%B9-%D1%81-%D0%BF%D0%BE%D1%82%D0%B5%D0%BD%D1%86%D0%B8%D0%B0%D0%BB%D0%BE%D0%BC-pe-sh-743e44a89c84?source=rss-cf3e92fa5914------2</link>
            <guid isPermaLink="false">https://medium.com/p/743e44a89c84</guid>
            <category><![CDATA[fr]]></category>
            <category><![CDATA[автоматизация]]></category>
            <category><![CDATA[eplan-p8]]></category>
            <dc:creator><![CDATA[Sergey Romanov]]></dc:creator>
            <pubDate>Fri, 15 Dec 2017 16:29:49 GMT</pubDate>
            <atom:updated>2017-12-15T16:29:49.452Z</atom:updated>
            <content:encoded><![CDATA[<blockquote>Идея статьи основана на статье Gerrant, для сайта eplan4all.info</blockquote><p>Если при размещении кабелей на схеме, мы назначаем им изделие кабеля, то правильным будет присвоить каждому соединению соответствующую функцию жилы кабеля для избежания ошибок при контрольном прогоне проекта.</p><p>Для начала нужно четко понять разницу между устройством кабель и изделием кабель.</p><h3>Устройство Кабель</h3><p>Допустим у нас ввод питания и схема такая.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/409/1*mo81E0Hi7VxcWCP-z8B8rA.jpeg" /><figcaption>Рис. 1</figcaption></figure><ol><li>Клеммники с функцией <em>“Клемма, общее, 2 вывода(ов)”</em></li><li>Клемма с функцией <em>“PE-клемма, 2 вывода(ов)”</em></li><li>Ввод потенциала L</li><li>Ввод потенциала PEN</li><li>Кабель подключения</li></ol><p>При размещении на схеме, каждое устройство кабеля <strong>W*</strong> автоматически определяет количество соединений (жил), в зависимости от количества пересечений с соединениями. Так же автоматически определяет потенциалы жил, если это возможно. Вот посмотрите как выглядит устройство кабеля <strong>W1</strong> в навигаторе устройств.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/313/1*hWvxpvrKhuIkr78kJa9Tcw.jpeg" /></figure><p>4 соединения (жилы) были автоматически определены и обозначены пиктограммой голубой куб. На одном соединении был определен потенциал <strong>PE.</strong> Это благодаря тому, что одна из жил кабеля была подключена к клемме с функцией <em>“PE-клемма, 2 вывода(ов)”</em>.</p><h3>Изделие кабель</h3><p>Каждое изделие кабеля в безе данных изделий имеет набор функций “Жила / провод” в количестве соответствующем количеству жил кабеля.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*vPkgTVui1aXzPfb877AKJA.jpeg" /><figcaption>Рис.2 Функции кабеля</figcaption></figure><p>Если у вас нет изделий кабеля, вы можете сами создать их взяв за основу любой другой кабель. Если у вас в базе изделий нет вообще ни каких кабелей, то <strong>можете </strong><a href="https://s3.amazonaws.com/serhioromano/PublicDownloads/asublog/%D0%A1%D0%B5%D0%B2%D0%BA%D0%B0%D0%B1%D0%B5%D0%BB%D1%8C.zip"><strong>скачать</strong></a><strong> базу изделий</strong> в формате XML <a href="https://s3.amazonaws.com/serhioromano/PublicDownloads/asublog/%D0%A1%D0%B5%D0%B2%D0%BA%D0%B0%D0%B1%D0%B5%D0%BB%D1%8C.zip">Севкабель</a>. Импортируйте это в вашу базу изделий. Это может стать хорошей отправной точкой.</p><p>Для назначения изделия кабеля, устройству кабеля, нужно убедиться что количеств жил изделия кабеля не меньше чем количество жил устройства кабеля.</p><p>Давайте назначим это изделие кабеля устройству <strong>W1</strong> на схеме.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/313/1*BDLUQBo9tGv_FX1tTbYqkw.jpeg" /><figcaption>Рис. 3</figcaption></figure><p>Вот что мы видим в навигаторе устройств на рисунке 3.</p><ol><li>Функции жил изделия кабеля. Мы видим что у <strong>изделия</strong> кабеля есть 4 функции “Жила\провод”. 3 С потенциалом <strong>L</strong> и одна с потенциалом <strong>N</strong>. Как на Рисунке 2.</li><li>Так же мы видим жилы <strong>устройства</strong> кабеля с которыми мы познакомились выше.</li></ol><p>Давайте выполним присвоение. Выделим устройство <strong>W1</strong> в навигаторе устройств и перейдем в меню.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/901/1*82YkiwNTEV8x38nVWE-BPw.jpeg" /><figcaption>Рис. 4 Меню присвоения функций изделия кабеля функция устройства кабеля.</figcaption></figure><p>И что мы видим?</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/355/1*We8AoTRxiLGC1Y4gomXsFA.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/313/1*OazKCahmQbjR62kyYGKTNQ.jpeg" /></figure><p>Видим что функции жил устройства были присвоены функциям жил изделия. Это видно по совмещенной пиктограмме. Но одна функция <strong>изделия кабеля</strong> не присваивалось жиле <strong>устройства кабеля</strong>. Это потому что они не соответствуют. В устройстве у нас потенциал <strong>PE</strong> а в изделии <strong>N</strong>.</p><p>Что бы от этого избавиться нам нужно заменить одну жилу изделия кабеля с <strong>N</strong> на <strong>PE</strong>. Но что бы не создавать новое изделие, мы можем создать новый вариант изделия.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*O3PNm4T_krwsSudNJFRevQ.jpeg" /></figure><p>В этом втором варианте делаем жилу потенциала <strong>PE</strong>.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*KnrmTD4WTsaBLtNnDl2WIA.jpeg" /></figure><p>Теперь в свойства кабеля, на вкладке изделие, выбираем второй вариант кабеля в свойстве &lt;20101&gt;.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*nqkO82MmNXGhKyN5aPZuog.jpeg" /></figure><p>Снова выделяем устройство <strong>W1</strong> и выполняем команду присвоения</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/901/1*82YkiwNTEV8x38nVWE-BPw.jpeg" /></figure><p>И видим что все встало по местам и все функции жил изделия, соответствуют функциям жил устройства.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/313/1*KIbgTELvc1gYD9A5_SjMKA.jpeg" /></figure><p>У нас есть разные потенциалы которые нужно варьировать это <strong>N</strong>, <strong>PE</strong>, <strong>PEN</strong>, <strong>SH. </strong>Так что у меня обычно 2–3 варианта каждого кабеля, которые я создаю по мере требования. Сначала было страшно, но как выяснилось я применяю всего 15–20 видов кабелей, и на создание базы ушло не так много времени как предполагалось.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=743e44a89c84" width="1" height="1" alt=""><hr><p><a href="https://medium.com/eplan4all/%D0%B0%D0%B2%D1%82%D0%BE%D0%BC%D0%B0%D1%82%D0%B8%D1%87%D0%B5%D1%81%D0%BA%D0%BE%D0%B5-%D0%BF%D1%80%D0%B8%D1%81%D0%B2%D0%BE%D0%B5%D0%BD%D0%B8%D0%B5-%D0%B6%D0%B8%D0%BB-%D0%BA%D0%B0%D0%B1%D0%B5%D0%BB%D0%B5%D0%B9-%D1%81-%D0%BF%D0%BE%D1%82%D0%B5%D0%BD%D1%86%D0%B8%D0%B0%D0%BB%D0%BE%D0%BC-pe-sh-743e44a89c84">Автоматическое присвоение жил кабелей с потенциалом PE/SH</a> was originally published in <a href="https://medium.com/eplan4all">EPLAN4ALL</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Личный опыт применения Eplan ProPanel на практике]]></title>
            <link>https://medium.com/eplan4all/%D0%BB%D0%B8%D1%87%D0%BD%D1%8B%D0%B9-%D0%BE%D0%BF%D1%8B%D1%82-%D0%BF%D1%80%D0%B8%D0%BC%D0%B5%D0%BD%D0%B5%D0%BD%D0%B8%D1%8F-eplan-propanel-%D0%BD%D0%B0-%D0%BF%D1%80%D0%B0%D0%BA%D1%82%D0%B8%D0%BA%D0%B5-704697000402?source=rss-cf3e92fa5914------2</link>
            <guid isPermaLink="false">https://medium.com/p/704697000402</guid>
            <category><![CDATA[eplan-p8]]></category>
            <category><![CDATA[eplan-propanel]]></category>
            <category><![CDATA[planes]]></category>
            <category><![CDATA[электрическая-схема]]></category>
            <category><![CDATA[проектирование]]></category>
            <dc:creator><![CDATA[Sergey Romanov]]></dc:creator>
            <pubDate>Thu, 14 Dec 2017 13:34:34 GMT</pubDate>
            <atom:updated>2017-12-14T13:34:34.329Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*iE5YiXUbrATsWnyUtks3fA.jpeg" /></figure><blockquote>Повествование от первого лица <a href="https://vk.com/id447113403">Кирилл Роменский</a> aka Kirya93</blockquote><p>Хочу рассказать о личном опыте внедрения в процесс сборки, автоматизацию на основе готового проекта <strong>EPLAN Electric P8</strong>, а конкретнее, выполненного в <strong>ProPanel</strong>. Уверен, что большинство читающих эту статью уже сталкивались с этим, но каких-то отчетов не видели.</p><p>Думаю, тема будет интересна новичкам. Да и вообще, на некоторые нюансы на которые проектировщик не обратил внимания, смогут существенно сэкономить монтажнику время, и нервы). Это мой первый проект в <strong>EPLAN ProPanel </strong>с использованием его на практике, поэтому с радостью приму всю критику.</p><p>Итак, было известно, что сборка шкафов (4 шт.) будет проходить в очень авральном режиме. При чем, независимо от сроков проектирования (сроки поставки оборудования шкафа почти совпадали с датой отгрузки щита)). Конечно, встал вопрос об оптимизации всего, что только можно при монтаже и сборке. Основной упор делался на то, чтобы у монтажников было минимум вопросов по схеме, а в идеале, чтобы схема не принимала участия в сборке шкафа. Учитывая все это, был спроектирован и отрисован в 3D шкафчик управления вентилятором.</p><p>Получилось вот такое дело:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/775/1*b1InUJocDgtwas2v-9-NmA.jpeg" /><figcaption>Модель щита в сборе</figcaption></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/832/1*eKkrGJnkGYmEH_HHY0I8sA.jpeg" /></figure><p>Сделаны отчеты, значительно облегчившие жизнь.</p><h4>1. Отчет размещения отверстий</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/800/1*mD3zTWqpvDDXLJpENZT59g.jpeg" /><figcaption>Схема размещения отверстий</figcaption></figure><p>Из моментов, хотелось бы выделить, лучше использовать «инкрементальное указание размеров» ибо мелочь, а время экономит. То есть, рулетку растянул и отмечаешь карандашиком точно, как на чертеже указано. А с обычными размерами (расстояние между кнопками), приходится голову задействовать (приплюсовывать), что тоже отнимает драгоценное время.</p><h4>2. Отчет Монтажная панель</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/800/1*RT71IxXmd9xxxOiAdTJ5bg.jpeg" /><figcaption>Монтажная схема</figcaption></figure><p>Из ошибок, опять же, нужно использовать «инкрементальные размеры», а также указывать расстояние между аппаратами на рейке. Ибо при монтаже «на глаз» возникли некоторые неудобства. Как видите, сразу это учтено не было и отчет практически пустой).</p><h4>3. Отчет таблица соединений</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/800/1*zLoLVPyMrDuqjIizZHPslg.jpeg" /><figcaption>Отчет соединений</figcaption></figure><p>Это вид, который вкладывается в документацию. Для монтажников шрифт был увеличен для удобства чтения.</p><p>Разберём столбцы:</p><ul><li><strong>Ссылка источник/цель</strong> — при возникновении каких-либо вопросов, монтажник с легкостью найдет соединение на схеме.</li><li><strong>Сечение, цвет, длина</strong> — тут, надеюсь, все понятно.</li><li><strong>Обозначение источника/цели</strong> — тут, для проектировщика, важно понимать, каким образом Eplan вычисляет где источник, а где цель. У меня, поначалу, из-за бездумного использования тройников, выходило так, что вместо раздачи массы от лампы к лампе на двери, шло 8 проводов от одной клеммы). Также сюда важно заносить не только обозначение аппарата, но и клеммник вместе с обозначением вывода.</li><li><strong>Направление вывода</strong> — как по мне, важная составляющая отчета (подробнее ниже). Собственно, из названия ясно, что это направление вывода проводника из устройства.</li><li><strong>Трасса маршрутизации</strong> — показывает, по каким кабельным каналам проходит проводник по пути от источника к цели. В данном проекте это не было сильно востребовано из-за небольших размеров шкафа (трасса маршрутизации угадывалась на глаз).</li></ul><p>Итак, как же выглядит процесс сборки на данном этапе развития как моего, так и нашей компании:) На такой шкаф, двое монтажников предостаточно. Трое будут большую часть времени толкаться и мешать друг другу. Хотя, если есть лишние, то почему нет?)</p><h4>1. Слесарные работы</h4><p><strong>Первый монтажник</strong> — размечает, сверлит отверстия, устанавливает аппараты на дверь. Размечает и сверлит фланцевую плату, устанавливает кабельные вводы (гермовводы).<br><strong>Второй монтажник </strong>— нарезает все короба (кабельные каналы) и рейки. Размечает, сверлит и закрепляет их на монтажной панели. Клеит короб на дверь</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/800/1*AUiYJpn-tlIxSks4gPvdEg.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/800/1*9VlzCCeVUNbRru_-JRG4gA.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/800/1*LkCy6_erIHC3fIxZQhD9nQ.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/800/1*_lGfqqpHmOaxfGj-QQ4tXw.jpeg" /></figure><h4>2. Установка аппаратов, клемм, их полная маркировка</h4><figure><img alt="" src="https://cdn-images-1.medium.com/max/800/1*J6hCo7TRRR4a1KgTHDAPHw.jpeg" /></figure><p><em>Ибо без маркировки дальнейшие действия бессмысленны)</em></p><h4>3. Подготовка проводов</h4><p>Далее самое интересное. Чертим линейку на «монтажном» столе. Или не чертим, если у вас есть нормальный монтажный стол). Чертим чуть больше метра, ибо на большее расстояние неудобно тянуться. Шаг — 50мм, меньше смысла нет.</p><blockquote>Далее один монтажник становится соединителем-разводителем, второй — обрезателем-обжимателем).</blockquote><p><strong>Теперь подробнее:</strong></p><p>Схему в этот раз я намеренно не печатал, чтобы не было соблазна на нее взглянуть. На крайний случай был ноутбук. У первого и второго рабочего в руках есть только по экземпляру таблицы соединений (выше есть фото), один лист общего вида монтажной панели и половина комплекта маркировок проводов у каждого.</p><p>Попробую объяснить. Например, есть соединения с 001 по 300. Значит всего маркировок 300*2 (на начало и конец провода). Так вот, у каждого рабочего есть комплект маркировок 001–300.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/800/1*83OmdCbTScwr652grEYR_A.jpeg" /><figcaption>на фото видна линейка и пластина маркировки</figcaption></figure><p>Алгоритм работы примерно следующий<br><strong>Первого</strong>:</p><ul><li>Смотрит номер соединения, цвет провода, сечение, длину.</li><li>Берет нужный провод, обрезает, обжимает</li><li>Цепляет одну маркировку с одного конца провода.</li></ul><p><strong>Второго</strong>:</p><ul><li>Берет уже готовый провод, смотрит на номер соединения, находит его в таблице и смотрит на направление вывода источника/цели.</li><li>Проверяет правильность установки маркировки относительно направления вывода (вся маркировка в шкафу должна читаться наклоном головы налево.)</li></ul><p><strong>Объяснение:</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/455/1*tmJObSbzS0JdC-BmIgxEMA.jpeg" /></figure><p>Если проводники, что на фото, установить в устройство сверху, то для чтения номера проводника, голову нужно будет наклонить вправо. Что не есть хорошо) Монтажник проверяет, можно ли установить проводник с таким расположением маркировки в источник либо в цель. Если нет, то просто сдвигает маркировку на другой конец провода. И вуаля, она становится перевернутой). Кажется долго и нудно, но со временем даже не обращаешь внимания, а сразу правильно подключаешь.</p><ul><li>Подсоединяет один конец к источнику/цели</li><li>Цепляет маркировку на второй конец провода, в соответствии с направлением вывода.</li><li>Проводит провод по его трассе маршрутизации и присоединяет к аппарату.</li></ul><p>На этом все.</p><p>Теперь о важных моментах, с которыми столкнулся только в процессе сборки:</p><p><strong>1.</strong> Eplan маршрутизирует соединения под прямым углом. Поначалу не мог понять, почему остается такой огромный запас провода.<br>Решение — в настройках проекта, в <em>«общая дополнительная длина маршрутизации» смело ставим «-50мм»</em>. Таким образом мы избавляемся от запаса.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/800/1*L52gb_Jb9QMdYLmYX7Wapw.jpeg" /></figure><p><strong>2.</strong> Eplan маршрутизирует все соединения предварительно выводя их до границ устройства (видно на фото ниже). Поэтому нужно смотреть на конкретный макрос устройства. Например, для двухэтажных клемм пришлось редактировать макрос. На рендере видно, что там явно перебор с проводом, в реальности будет меньше. Поле «доп. длина» установил равным «-55 мм». После этого огромный запас ушел и все провода приходили к цели как раз с небольшим нахлёстом.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/814/1*5ICVVRnD0tZSCBDRYqbvRQ.jpeg" /></figure><figure><img alt="" src="https://cdn-images-1.medium.com/max/723/1*Doe_WTrRzQgqjWc3NS5wEw.jpeg" /></figure><p><strong>3.</strong> На вопрос, почему всю маркировку не отдать одному монтажнику, приведу это фото</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/800/1*83OmdCbTScwr652grEYR_A.jpeg" /></figure><p><em>Тот, кто цепляет провода не всегда успевает за тем, кто их обжимает). А номер проводника нужно как-то узнать.</em></p><h3>Впечатления</h3><p>Теперь об эффекте, полученном от всего этого извращения.</p><p><strong>1)</strong> На сборку одного такого шкафа с нуля уходит два дня размеренной работы двух человек с 8 до 17. Или же один день без перерыва с 8 до 23. Собственно, вторым мы и занимались, в основном) Не могу сказать, много это или мало, но точно быстрее, чем было у нас раньше.</p><p><strong>2)</strong> Можно выполнить полную разводку проводников шкафа, не имея вообще никакого оборудования. Как для меня, так это очень большое преимущество, когда контроллеры и модули по несколько месяцев ждать нужно. Шкаф собрал, а потом просто модули вставил и подсоединил. Собственно, это было тут же протестировано. Таможня задержала контроллер на две недели)</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/843/1*5cMtoi0fS4K8oqlKxyIhqA.jpeg" /></figure><p>После чего шкаф был дособран где-то за 10 минут.)</p><p><strong>3)</strong> Сокращение количества ошибок монтажников. При таком подходе, когда монтажнику не нужна схема, Он попросту не сможет наваять что-то по-своему.</p><p><strong>4) </strong>Некоторое снижение требований к квалификации монтажников. Но это пока не мое дело) К слову, за все время сборки, обращаться к электрической схеме мне пришлось всего три раза.</p><p>Конечно, я не претендую, что такой подход к организации процесса является на сто процентов правильным. Но, думаю, общаясь и обмениваясь опытом, можно выработать хорошую методику.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=704697000402" width="1" height="1" alt=""><hr><p><a href="https://medium.com/eplan4all/%D0%BB%D0%B8%D1%87%D0%BD%D1%8B%D0%B9-%D0%BE%D0%BF%D1%8B%D1%82-%D0%BF%D1%80%D0%B8%D0%BC%D0%B5%D0%BD%D0%B5%D0%BD%D0%B8%D1%8F-eplan-propanel-%D0%BD%D0%B0-%D0%BF%D1%80%D0%B0%D0%BA%D1%82%D0%B8%D0%BA%D0%B5-704697000402">Личный опыт применения Eplan ProPanel на практике</a> was originally published in <a href="https://medium.com/eplan4all">EPLAN4ALL</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Присвоение графики свойствам клеммы на примере отчета: F11 Схема подключения клемм]]></title>
            <link>https://medium.com/eplan4all/%D0%BF%D1%80%D0%B8%D1%81%D0%B2%D0%BE%D0%B5%D0%BD%D0%B8%D0%B5-%D0%B3%D1%80%D0%B0%D1%84%D0%B8%D0%BA%D0%B8-%D1%81%D0%B2%D0%BE%D0%B9%D1%81%D1%82%D0%B2%D0%B0%D0%BC-%D0%BA%D0%BB%D0%B5%D0%BC%D0%BC%D1%8B-%D0%BD%D0%B0-%D0%BF%D1%80%D0%B8%D0%BC%D0%B5%D1%80%D0%B5-%D0%BE%D1%82%D1%87%D0%B5%D1%82%D0%B0-f11-%D1%81%D1%85%D0%B5%D0%BC%D0%B0-%D0%BF%D0%BE%D0%B4%D0%BA%D0%BB%D1%8E%D1%87%D0%B5%D0%BD%D0%B8%D1%8F-%D0%BA%D0%BB%D0%B5%D0%BC%D0%BC-747cf82ba574?source=rss-cf3e92fa5914------2</link>
            <guid isPermaLink="false">https://medium.com/p/747cf82ba574</guid>
            <category><![CDATA[отчеты]]></category>
            <category><![CDATA[автоматизация]]></category>
            <category><![CDATA[клемминк]]></category>
            <category><![CDATA[eplan-p8]]></category>
            <category><![CDATA[проектирование]]></category>
            <dc:creator><![CDATA[Sergey Romanov]]></dc:creator>
            <pubDate>Mon, 11 Dec 2017 14:51:31 GMT</pubDate>
            <atom:updated>2017-12-24T18:07:28.321Z</atom:updated>
            <content:encoded><![CDATA[<p>Рассмотрим на примере формы отчета <strong>F11 схема подключение клемм</strong>, присвоение графики определенному свойству.</p><p><a href="https://s3.amazonaws.com/serhioromano/PublicDownloads/asublog/SR_F11_001.zip"><strong>Скачать форму SR_F11_001</strong></a></p><p>Прежде чем разобрать устройство этой формы, посмотрите видео ее возможностей.</p><blockquote>Эта форма отчета, как и видео, созданы <a href="http://asutpforum.ru/viewtopic.php?f=17&amp;t=3947">Ивановым Максимом</a> и востановлены с потеряного сайта Eplan4all.info</blockquote><iframe src="https://cdn.embedly.com/widgets/media.html?src=https%3A%2F%2Fwww.youtube.com%2Fembed%2F1l46g6BrkwE%3Ffeature%3Doembed&amp;url=http%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3D1l46g6BrkwE&amp;image=https%3A%2F%2Fi.ytimg.com%2Fvi%2F1l46g6BrkwE%2Fhqdefault.jpg&amp;key=a19fcc184b9711e1b4764040d3dc5c07&amp;type=text%2Fhtml&amp;schema=youtube" width="854" height="480" frameborder="0" scrolling="no"><a href="https://medium.com/media/369cdf51f47c01954aca7f0c47c4ed54/href">https://medium.com/media/369cdf51f47c01954aca7f0c47c4ed54/href</a></iframe><p>Можете просто скачать форму и пользоваться, но для тех кто хочет понять как это работает, предлагаю продолжать читать.</p><p>Для того чтобы форма заработала, убедитесь что библиотека IEC_Simbol подключена в <em>Настройках проекта / Управление /Библиотеки символов</em>.</p><ol><li>Скопируйте файл формы в папку <em>C:\Users\Public\EPLAN\Data\Forms\Company name</em>.</li><li>Перейдите в <em>Сервисные программы / Основные данные / Формы / Открыть…</em> и откройте форму SR_F11_001</li><li>В навигаторе страниц, нажмите правой кнопкой на имени открытой формы, и выберите <em>Свойства…</em></li></ol><figure><img alt="" src="https://cdn-images-1.medium.com/max/375/1*DLw8JLUcmpki_eYcwvQjBg.png" /></figure><p>Если взять например свойство клеммы как “<em>Определение функции</em>”, то в отчете для этого есть специальное свойство <em>&lt;13021&gt; Присвоение определения функции графике </em>где можно определить список соответствий графики, на каждое <em>Определение функции</em>.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/826/1*320L04Ue_0ndQ0vJFozivA.png" /><figcaption>Окно свойств стандартной формы схема подключения клемм F11_006.F11</figcaption></figure><ol><li>Свойство присвоения определения функции графике</li><li>Список клемм и их определения функции</li><li>Графика соответствующая каждому определению</li></ol><p>Но если мы хотим присвоить графику на другие свойства, как например <em>&lt;20230&gt; Категория клеммы</em> значение которой выбирается из списка, или <em>&lt;20231&gt; Клемма со светодиодом</em> которая активируется чекбоксом, мы можем воспользоваться свойством формы <em>&lt;13026 *&gt; Присвоение свойства / значения графике [*]</em> где [*] порядковый номер свойства.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/826/1*my4ESFHYqKti_xmVbs9sHA.png" /><figcaption>Свойства 13026 в окне свойств формы MI_F11_001</figcaption></figure><p>Обратите внимание что мы используем и свойство <em>&lt;13021&gt; Присвоение определения функции графике</em> через которое мы показываем графику клеммы для N и PE клемм.</p><p>Так же мы используем 2 набора свойств &lt;13026&gt;.</p><p>Одно для категории клеммы. Здесь мы отображаем отдельный символ для каждой категории.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/741/1*cp8LX6HwiIgNxRRxVYoQQQ.png" /><figcaption>Свойство категории клеммы в свойствах ОУ клеммы</figcaption></figure><p>Вот так выглядит список присвоения графики категориям в свойстве &lt;13026&gt;:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/913/1*su-TagLEmWeO5QOxMuh_Hg.png" /></figure><ol><li>Список доступных значений свойств категории да и других свойств с выпадающим списком можно <a href="http://www.eplan.help/help/platform/2.7/ru-ru/help/EPLAN_help.htm#htm/xmlexport_o_sellists.htm%3FTocPath%3D%25D0%259E%25D0%25B1%25D0%25B7%25D0%25BE%25D1%2580%25D1%258B%2520EPLAN%7C%25D0%2598%25D0%25BC%25D0%25BF%25D0%25BE%25D1%2580%25D1%2582%2520%25D0%25B8%2520%25D1%258D%25D0%25BA%25D1%2581%25D0%25BF%25D0%25BE%25D1%2580%25D1%2582%2520XML%2520(%25D0%2591%25D0%25B0%25D0%25B7%25D0%25B0%2520%25D0%25B4%25D0%25B0%25D0%25BD%25D0%25BD%25D1%258B%25D1%2585%2520%25D0%25B8%25D0%25B7%25D0%25B4%25D0%25B5%25D0%25BB%25D0%25B8%25D0%25B9%2520EPLAN)%7C%25D0%259E%25D0%25B1%25D0%25B7%25D0%25BE%25D1%2580%7C_____3">увидеть тут</a>.</li></ol><p>Другое свойство &lt;13026&gt; для других 2х свойств клеммы.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/739/1*JA2JS77wIEhUd1anBhP2Fg.png" /></figure><p>Мы используем только одно свойство формы&lt;13026&gt; для этих 2х свойств клеммы. Вот так выглядит список присвоения графики свойства формы &lt;13026&gt;.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/979/1*Grw4AYxO1QKuMcQMqh4Wgw.png" /><figcaption>Список свойства &lt;13026&gt;</figcaption></figure><p>Разместить каждую группу свойств &lt;13026&gt; на форме мы можем только один раз. А значит и графика будет только одна. Если мы пометим в свойствах клеммы, что и <em>&lt;20231&gt; Клемма со светодиодом</em> и <em>&lt;20283&gt; Клемма со штекерным адаптером</em> активны для одной клеммы, в отчете будет только одна графика. Или графика светодиода, или штекерного соединения. Но тут точно видно что будет графика светодиода, так как она (графика) в списке первая.</p><p>Конкретно в этом случае, это допустимо, потому что я не знаю клемм где 2 этих свойства сочетаются вместе. Но в других случаях, возможно придется создать дополнительное свойство формы <em>&lt;13026&gt; Присвоение свойства / значения графике.</em></p><h4>Результат</h4><p>Вот как выглядит готовая форма размещенная на странице. Это набор клеммников с держателем предохранителя, которые от блока питания UZ1 защищают контроллер и модули I/O D*.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/535/1*2o5o7zApx19rMshMzLonsw.png" /></figure><p><strong>В оригинал данной формы я внес несколько правок</strong>. Выровнял графику, добавил описание и ОУ клеммника из определения клеммника.</p><p>Для того что бы отобразить имя клеммника и его описание, создайте определение клеммника и явно выберите ОУ. Явно это значит нажмите троеточие и выберите ОУ клеммника. Даже если вы его не выберите, определение клеммника, будет привязано к этому ОУ, но имени клеммника не будет видно в отчете пока в определении клеммника вы явно не выберите ОУ. Добавьте к определению клеммника Функциональный текст.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=747cf82ba574" width="1" height="1" alt=""><hr><p><a href="https://medium.com/eplan4all/%D0%BF%D1%80%D0%B8%D1%81%D0%B2%D0%BE%D0%B5%D0%BD%D0%B8%D0%B5-%D0%B3%D1%80%D0%B0%D1%84%D0%B8%D0%BA%D0%B8-%D1%81%D0%B2%D0%BE%D0%B9%D1%81%D1%82%D0%B2%D0%B0%D0%BC-%D0%BA%D0%BB%D0%B5%D0%BC%D0%BC%D1%8B-%D0%BD%D0%B0-%D0%BF%D1%80%D0%B8%D0%BC%D0%B5%D1%80%D0%B5-%D0%BE%D1%82%D1%87%D0%B5%D1%82%D0%B0-f11-%D1%81%D1%85%D0%B5%D0%BC%D0%B0-%D0%BF%D0%BE%D0%B4%D0%BA%D0%BB%D1%8E%D1%87%D0%B5%D0%BD%D0%B8%D1%8F-%D0%BA%D0%BB%D0%B5%D0%BC%D0%BC-747cf82ba574">Присвоение графики свойствам клеммы на примере отчета: F11 Схема подключения клемм</a> was originally published in <a href="https://medium.com/eplan4all">EPLAN4ALL</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Маркировка — Групповая спецификация изделий]]></title>
            <link>https://medium.com/eplan4all/%D0%BC%D0%B0%D1%80%D0%BA%D0%B8%D1%80%D0%BE%D0%B2%D0%BA%D0%B0-%D0%B3%D1%80%D1%83%D0%BF%D0%BF%D0%BE%D0%B2%D0%B0%D1%8F-%D1%81%D0%BF%D0%B5%D1%86%D0%B8%D1%84%D0%B8%D0%BA%D0%B0%D1%86%D0%B8%D1%8F-%D0%B8%D0%B7%D0%B4%D0%B5%D0%BB%D0%B8%D0%B9-49a70031922f?source=rss-cf3e92fa5914------2</link>
            <guid isPermaLink="false">https://medium.com/p/49a70031922f</guid>
            <category><![CDATA[eplan-p8]]></category>
            <category><![CDATA[проектирование]]></category>
            <category><![CDATA[автоматизация]]></category>
            <category><![CDATA[eplan4all]]></category>
            <category><![CDATA[маркировка]]></category>
            <dc:creator><![CDATA[Sergey Romanov]]></dc:creator>
            <pubDate>Mon, 11 Dec 2017 14:15:28 GMT</pubDate>
            <atom:updated>2017-12-11T14:56:14.491Z</atom:updated>
            <content:encoded><![CDATA[<h3>Маркировка — Групповая спецификация изделий</h3><blockquote>Эта статья от первого лица, <a href="http://www.youtube.com/user/eplan4all">Андрея Горского</a> восстановленная с сайта <strong>Eplan4All.info</strong></blockquote><p>Очень часто, даже почти всегда, в ходе проектирования, мы начинаем проект, отталкиваясь от ранее исполненного похожего проекта. То есть берем более-менее похожий проект и подгоняем его под новое техзадание. Параметр схожести в моем случае выступает комплектация, применяемое оборудование или <em>групповая спецификация изделий</em>.</p><p>При получении нового задания мы, я и мои коллеги по работе, обращались к бумажным версиям опросных листов в которых искали разные параметры как например: применяемый блок РЗА, силовой выключатель, и т.д.. Критерии поиска могли быть и более специфичны. Но так как со временем реализованных проектов становилось больше, то поиск в груде бумаги становился более затруднительным. Лень двигатель прогресса. Устав копошиться в стопках бумаги как “книжный червь”, я вспомнил про чудесный функционал в Eplan — Маркировка.</p><p>Я взялся за работу “оцифровки” групповой спецификаций изделий всех проектов. В том как это делается, нет ни какой магии.</p><h3>Инструкция по выгрузке</h3><p>Для начала скачаете вот эти файлы:</p><ul><li>XLSM файл шаблона для выгрузки: <a href="https://s3.amazonaws.com/serhioromano/PublicDownloads/asublog/%D0%A1%D0%BF%D0%B5%D1%86%D0%B8%D1%84%D0%B8%D0%BA%D0%B0%D1%86%D0%B8%D1%8F_%D1%81_%D0%BC%D0%B0%D0%BA%D1%80%D0%BE%D1%81%D0%B0%D0%BC%D0%B8.xlsm">Спецификация_с_макросами.xlsm</a></li><li>XML файл настройки выгрузки: <a href="https://s3.amazonaws.com/serhioromano/PublicDownloads/asublog/LB.SR_%D0%93%D1%80%D1%83%D0%BF%D0%BF%D0%BE%D0%B2%D0%B0%D1%8F_%D1%81%D0%BF%D0%B5%D1%86%D0%B8%D1%84%D0%B8%D0%BA%D0%B0%D1%86%D0%B8%D1%8F_%D0%B8%D0%B7%D0%B4%D0%B5%D0%BB%D0%B8%D0%B9.xml">LB.SR_Групповая_спецификация_изделий.xml</a></li></ul><p>Теперь приступим к выгрузке:</p><ol><li>Переходите в <em>Сервисные программы / Данные изготовителя / Экспорт — Маркировка…</em></li></ol><p>2. В открывшемся окне нажмем на кнопку троеточие для настроек выгрузки</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/483/1*hLb_DPIHDvKlrVpbBp_LZw.png" /><figcaption>Окно экспорта маркировки</figcaption></figure><p>3. В новом окне, нажимаем кнопку импорта (1) и импортируем наш файл настроек <em>LB.SR_Групповая_спецификация_изделий.xml</em>. Она становиться текущей выбранной.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/766/1*HUGPe5M7jldMqwsVose4tg.png" /><figcaption>Окно настроек экспорта маркировки</figcaption></figure><p>4. В поле шаблон (3) мы выбираем наш файл <em>Спецификация_с_макросами.xlsm</em>.</p><p>5. В поле целевой файл (2), нужно указать любое имя файла в который вы хотите сделать выгрузку. Не обязательно создавать файл заранее.</p><p>6. Жмем кнопку ОК и сохраним настройки.</p><p>7. Теперь жмем кнопку ОК в окне экспорта.</p><p>И так проект за проектом</p><h3>Как я до этого дошел</h3><p>Однако изначально я столкнулся с одной неприятной проблемой. Мы можем выгрузить только один проект за раз и мы можем выгрузить один проект в один файл. Получается кипы бумаг, теперь заменятся кучей файлов, и поиск будет так же затруднен. Нужно было собрать все спецификации в один файл. Руками это делать не хотелось, нудновато. Пошел искать решения во всемирной сети.</p><p>Поисковик указал на работу Николая Павлова блог «Планета Excel» <a href="http://www.planetaexcel.ru/techniques/12/49/">Сборка листов из разных книг в одну</a>. Используя полученные знания я доработал шаблон который изначально был просто в формате <em>*.xsl</em>. Создал нужные макросы сборки листов, добавил кнопку загрузки данных из другого файла XSL, и теперь это формат файла <em>*.xls</em><strong><em>m</em></strong> где <strong>m</strong> означает <strong>m</strong>acros. Имея подобный шаблон, задача упростилась и после объединения всех спецификаций в один файл, можно продуктивно задействовать механизмы поиска в Excel.</p><p>Все было хорошо, но вот выявилась маленькая деталь. Посмотрите на названия страниц.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/626/1*RVaH1ZpbQAIilTOlt7fqPw.png" /><figcaption>Имена листов в файле Эксель</figcaption></figure><p>Такие закладки не информативны, так как порой мы будем обращаться к спецификации зная заказ. А перебирать листы наугад не вариант. Следовательно, хотелось бы в идеале, номер заказа в имени листа. Коротко и информативно.</p><p><a href="http://forum.msexcel.ru/index.php/topic,2745.msg15185.html#msg15185">Понравилось решение</a> предложенное Гусевым Александром Валентиновичем aka <strong>_boroda_</strong>, за небольшим исключением. Каждый лист, нового файла, будет переименован в номер заказа, который указан в шаблоне отчета. Но есть недостаток — переименование происходит по действию, то есть нужно совершить любой действие с ячейкой A1 где и храниться номер заказа. Можно просто установить там курсор, и нажать клавишу Ввод.</p><p>В версии файла преложенного тут все вышеуказанные фишки присутствуют.</p><p>Посмотрите небольшое видео где видно как это работает.</p><iframe src="https://cdn.embedly.com/widgets/media.html?src=https%3A%2F%2Fwww.youtube.com%2Fembed%2FQJoPXT-Vn4c%3Ffeature%3Doembed&amp;url=http%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3DQJoPXT-Vn4c&amp;image=https%3A%2F%2Fi.ytimg.com%2Fvi%2FQJoPXT-Vn4c%2Fhqdefault.jpg&amp;key=a19fcc184b9711e1b4764040d3dc5c07&amp;type=text%2Fhtml&amp;schema=youtube" width="640" height="480" frameborder="0" scrolling="no"><a href="https://medium.com/media/833c46426362fd7d5315092acf796e01/href">https://medium.com/media/833c46426362fd7d5315092acf796e01/href</a></iframe><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=49a70031922f" width="1" height="1" alt=""><hr><p><a href="https://medium.com/eplan4all/%D0%BC%D0%B0%D1%80%D0%BA%D0%B8%D1%80%D0%BE%D0%B2%D0%BA%D0%B0-%D0%B3%D1%80%D1%83%D0%BF%D0%BF%D0%BE%D0%B2%D0%B0%D1%8F-%D1%81%D0%BF%D0%B5%D1%86%D0%B8%D1%84%D0%B8%D0%BA%D0%B0%D1%86%D0%B8%D1%8F-%D0%B8%D0%B7%D0%B4%D0%B5%D0%BB%D0%B8%D0%B9-49a70031922f">Маркировка — Групповая спецификация изделий</a> was originally published in <a href="https://medium.com/eplan4all">EPLAN4ALL</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
    </channel>
</rss>