<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Sergii Zhulid on Medium]]></title>
        <description><![CDATA[Stories by Sergii Zhulid on Medium]]></description>
        <link>https://medium.com/@suzhkh?source=rss-a80d4d380704------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/0*nJwhPtfwjcAxveYi</url>
            <title>Stories by Sergii Zhulid on Medium</title>
            <link>https://medium.com/@suzhkh?source=rss-a80d4d380704------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Sat, 28 Nov 2026 22:36:21 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@suzhkh/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Upgrading the Backbone: Coax Splicing, HI-Split, and Field Training for America’s Next-Gen Networks]]></title>
            <link>https://medium.com/@suzhkh/upgrading-the-backbone-coax-splicing-hi-split-and-field-training-for-americas-next-gen-networks-824ff8e20d03?source=rss-a80d4d380704------2</link>
            <guid isPermaLink="false">https://medium.com/p/824ff8e20d03</guid>
            <category><![CDATA[coaxial-connectors]]></category>
            <category><![CDATA[coaxial-cable]]></category>
            <category><![CDATA[coaxial]]></category>
            <dc:creator><![CDATA[Sergii Zhulid]]></dc:creator>
            <pubDate>Sun, 27 Jul 2025 04:29:22 GMT</pubDate>
            <atom:updated>2025-07-27T04:29:22.781Z</atom:updated>
            <content:encoded><![CDATA[<p>Upgrading the Backbone: Coax Splicing, HI-Split, and Field Training for America’s Next-Gen Networks</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*oWehOFfuDnsmU8jZs1coRQ.jpeg" /></figure><p>By Sergii Zhulid</p><p>While fiber optic deployment dominates headlines, coaxial cable networks remain a critical part of America’s connectivity infrastructure — especially in hybrid fiber-coax (HFC) systems. Across dozens of cities and rural areas, ISPs continue to rely on coax upgrades to extend broadband speeds and capacity while full fiber rollouts continue.</p><p>I’ve spent the last several years not just splicing and balancing coax networks — but also training new field technicians to handle real-world challenges in Hi-Split upgrades. Here&#39;s what that looks like from the ground.</p><p>---</p><p>🔧 What Is a Hi-Split Upgrade?</p><p>In traditional coaxial systems, upstream data is limited to around 42 MHz — a bottleneck for today’s Zoom meetings, cloud storage, and upload-heavy tasks.</p><p>Hi-Split upgrades push the upstream frequency range up to 85 MHz or even 204 MHz, improving upload speeds and future-proofing the network. But to make that happen, we need to splice, replace, balance, and test huge portions of existing coax infrastructure.</p><p>---</p><p>⚙️ My Role in the Field</p><p>In Missouri, Kentucky, and New York, I’ve worked on multiple Hi-Split upgrade projects, where responsibilities included:</p><p>Coaxial splicing (hardline, RG6/RG11, ARIS/ATX/Technetix hardware)</p><p>Replacing taps, splitters, and amplifiers</p><p>Balancing signal levels to maintain required dB specifications</p><p>Labeling and documenting legacy vs. upgraded nodes</p><p>Training new hires on safe handling, connector integrity, and line testing</p><p>These tasks often had to be done overnight to avoid service disruptions — sometimes in sub-zero weather or remote mountain neighborhoods.</p><p>---</p><p>👨‍🏫 Training the Next Generation</p><p>On large projects like the Lexington Hi-Split upgrade, I was tasked with onboarding new coax technicians — many of whom had little to no field experience.</p><p>Here’s how I structured their first week:</p><p>1. Day 1–2: Tool familiarization (strippers, compression tools, signal meters).</p><p>2. Day 3: Supervised live tap replacement.</p><p>3. Day 4–5: Independent node maintenance + QC checklist compliance.</p><p>4. Ongoing: Shadowing advanced splice and balance sessions.</p><p>We focused not just on what to do — but why it matters: a single bad splice or poorly crimped connector can impact entire neighborhoods.</p><p>---</p><p>📡 Signal Testing and Documentation</p><p>No splicing job ends until we test:</p><p>Upstream &amp; downstream power levels</p><p>Return loss</p><p>SNR (Signal-to-Noise Ratio)</p><p>Ingress detection</p><p>I teach new techs to record all values, compare them to spec sheets, and always take “before and after” photos of hardware trays, tags, and amplifiers. This not only ensures quality but protects teams from false blame if issues arise later.</p><p>---</p><p>💡 Final Thoughts</p><p>Upgrading America’s broadband infrastructure doesn’t happen only in datacenters or fiber rings — it happens on ladders, in pedestals, and at node cabinets at 2:00 AM.</p><p>By combining hands-on coaxial fieldwork with structured technician training, I’ve helped build teams that deliver speed, stability, and pride in the work.</p><p>As the U.S. continues to modernize its networks, we need not just more workers — but more mentors willing to pass down experience that can’t be Googled.</p><p>– Sergii Zhulid<br>Field Supervisor / Coax Splicing Trainer<br>Denver, CO</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=824ff8e20d03" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Bore Profile, Not Just a Hole: Field-Level Quality Control in HDD for Fiber Deployment]]></title>
            <link>https://medium.com/@suzhkh/bore-profile-not-just-a-hole-field-level-quality-control-in-hdd-for-fiber-deployment-151157b47e73?source=rss-a80d4d380704------2</link>
            <guid isPermaLink="false">https://medium.com/p/151157b47e73</guid>
            <category><![CDATA[hdd-drilling]]></category>
            <category><![CDATA[pooling]]></category>
            <category><![CDATA[blowing]]></category>
            <dc:creator><![CDATA[Sergii Zhulid]]></dc:creator>
            <pubDate>Sun, 27 Jul 2025 04:11:23 GMT</pubDate>
            <atom:updated>2025-07-27T04:11:23.801Z</atom:updated>
            <content:encoded><![CDATA[<p>Bore Profile, Not Just a Hole: Field-Level Quality Control in HDD for Fiber Deployment</p><p>By Sergii Zhulid</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*pJH3vsW2tOg8VcwRTbs_sg.jpeg" /></figure><p>Horizontal Directional Drilling (HDD) is the invisible foundation of modern fiber networks — especially in rural and suburban areas where trenching is disruptive or impractical. Yet what happens underground is often left undocumented, poorly inspected, or rushed to meet deadlines.</p><p>Having worked as a QC inspector and HDD specialist across multiple U.S. states, I’ve learned that bore profile quality control isn’t just about ticking boxes — it’s about infrastructure resilience, public safety, and long-term signal integrity.</p><p>---</p><p>🎯 What Is “Bore QC” in Real Life?</p><p>Quality control in HDD starts with one simple truth: a straight drill does not mean a safe one.</p><p>We routinely verify:</p><p>Entry and exit angles (to avoid pipe strain)</p><p>Depth-to-surface clearance (esp. under roads, gas lines, or waterways)</p><p>Bore path deviation and unintended deflection</p><p>Casing quality before fiber is blown through</p><p>Each bore is accompanied by a photographic report, including equipment used, terrain type, restoration notes, and GPS-tagged verification photos. This is not paperwork — it&#39;s insurance against future cable failures and liability.</p><p>---</p><p>📷 QC Reporting: My Daily Toolkit</p><p>I typically use:</p><p>Bore logs from Vermeer or Ditch Witch rigs</p><p>Manual depth probes</p><p>Digital inclinometers for slope calculation</p><p>Photo documentation in English, including landmarks, street signs, and trenchless entry/exit points</p><p>As-built drawings with redline corrections</p><p>All these are compiled into structured reports delivered to PMs, clients, and even municipal inspectors.</p><p>---</p><p>🛑 Preventing Common Field Failures</p><p>Here’s what I’ve caught before they became $100,000 problems:</p><p>Drills surfacing into private property lines</p><p>Shallow bores under parking lots risking asphalt collapse</p><p>Unlabeled open handholes left after fiber pull</p><p>Drilled too close to tree roots or water mains</p><p>Each time, I worked with drillers to correct alignment or redo bores entirely. I always say: “One hour of QC beats 10 hours of rework.”</p><p>---</p><p>👷 Working Alongside Crews and Cities</p><p>My role wasn’t just documentation — it was translation between field teams and compliance. In Michigan, I often met directly with city inspectors to walk job sites, validate surface restoration (asphalt, sidewalk, landscaping), and ensure all bore depths aligned with permits.</p><p>I also trained techs on OSHA safety protocols and internal QC procedures — helping them move from guesswork to discipline.</p><p>---</p><p>📡 Why HDD QC Matters More Than Ever</p><p>With billions in federal funds pushing fiber deeper into American towns, HDD drilling has exploded — and so has the risk of cutting corners.</p><p>Without field-level QC:</p><p>Cables get crushed, flooded, or overstressed underground.</p><p>Cities face legal claims from poorly restored bores.</p><p>ISPs suffer signal loss and premature maintenance.</p><p>But with strong HDD oversight, we build lasting infrastructure that supports education, telehealth, and digital inclusion.</p><p>---</p><p>Final Note</p><p>Every cable I helped bury was a connection for someone: a student, a hospital, a small business. That’s why I approach HDD QC not as a checkbox — but as a duty to communities.</p><p>If you&#39;re in the field, don’t underestimate your eyes and your notes. They might just save the next project.</p><p>– Sergii Zhulid<br>Fiber QC Inspector | HDD Specialist<br>Denver, CO</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=151157b47e73" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Ribbon Fiber Splicing in the Field: Real-World Lessons, Techniques, and Safety Insights]]></title>
            <link>https://medium.com/@suzhkh/ribbon-fiber-splicing-in-the-field-real-world-lessons-techniques-and-safety-insights-a2a94cd5ba47?source=rss-a80d4d380704------2</link>
            <guid isPermaLink="false">https://medium.com/p/a2a94cd5ba47</guid>
            <category><![CDATA[splicing-machine]]></category>
            <category><![CDATA[fiber-optics]]></category>
            <category><![CDATA[broadband-infrastructures]]></category>
            <category><![CDATA[fusion-splicing]]></category>
            <category><![CDATA[fusion-splicing-machine]]></category>
            <dc:creator><![CDATA[Sergii Zhulid]]></dc:creator>
            <pubDate>Sun, 27 Jul 2025 04:05:14 GMT</pubDate>
            <atom:updated>2025-07-27T04:05:14.065Z</atom:updated>
            <content:encoded><![CDATA[<p>Ribbon Fiber Splicing in the Field: Real-World Lessons, Techniques, and Safety Insights</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*DqY9vKbqoC2Ha_e2cr8KOA.jpeg" /></figure><p>By Sergii Zhulid</p><p>In the fast-moving world of broadband infrastructure, ribbon fiber splicing has become an essential technology — especially for high-density, time-sensitive projects in underserved and rural areas. Having worked as a fiber splicing technician, field supervisor, and quality control inspector across multiple U.S. states, I’ve experienced both the advantages and the unique challenges of working with ribbon systems in the field.</p><p>This post is a reflection on real-life lessons I’ve learned working with ribbon fiber — and a few tips that might help those just starting out.</p><p>---</p><p>📌 Why Ribbon?</p><p>Ribbon fiber allows technicians to splice 12 fibers in a single operation — a huge advantage in terms of labor and time. It’s ideal for backbone networks, large-scale FTTH deployments, and any project where space, density, and deadlines matter.</p><p>But speed comes at a price: ribbon splicing requires greater precision, cleaner prep, and a solid understanding of fusion equipment like Fujikura, Sumitomo, or similar machines.</p><p>---</p><p>🛠 The Real-World Challenges We Face</p><p>1. Ribbon Splicers Are Sensitive to Humidity<br>Splicers don’t always behave predictably in the field. In high-humidity environments, they can become inconsistent. Sometimes the cleaver doesn’t give you a clean break across all 12 fibers. One fiber with an aggressive cleave angle is enough to compromise the whole ribbon — forcing a redo and shortening your usable length inside the tray.</p><p>That’s why careful attention, manual finesse, and a bit of artistry are key. I treat every tray layout as a craft — each ribbon placed side-by-side like a carpenter aligning wood grain. A clean, beautiful tray is not just satisfying to the eye — it’s professional.</p><p>---</p><p>2. Adapting Loose-Tube to Ribbon (and Vice Versa)<br>Not all networks are architecturally consistent. On one Michigan project, we had to connect loose-tube fibers to ribbon SWR (Single Wide Ribbon). Our team learned how to rebuild the ribbon manually — sorting fibers by color into micro clips and applying fast-drying lacquer to hold shape.</p><p>In other cases, we had to decide: should we break down the ribbon into singles — or convert the loose-tube into a ribbon? The choice depended on the fiber count, tray design, available stock, and most importantly — our own experience.</p><p>One thing is clear: testing won’t forgive bad splices, and responsibility falls on the splicer. We are the final link in the chain — and that means full accountability.</p><p>---</p><p>3. The Environment Always Wins<br>Splicing in a lab is easy. Try doing it in a frozen trailer in Michigan or in 90% humidity in Florida. Temperature swings, condensation, dust — all impact splice quality. Field splicing is not just technical — it’s physical endurance.</p><p>---</p><p>4. Safety First — Always<br>Fiber is glass. After cleaving, always cut off at least an inch. Short fragments are nearly invisible and dangerously light — they can stick to clothing, travel home, be inhaled, or lodge under your skin like a splinter.</p><p>No food or drinks at the splice table. Wash hands thoroughly. Never mix work clothes with your family’s laundry. Respecting these rules isn’t overkill — it’s what keeps you and your family safe.</p><p>---</p><p>📏 Testing and QC</p><p>Once the splicing is complete, OTDR and power meter testing are critical. With ribbon, one bad splice can compromise 12 fibers. I regularly perform bidirectional OTDR tests, analyze events, and ensure every fiber passes spec.</p><p>Quality is not just about dB readings — it’s also about visual documentation. My teams always photograph tray layouts, document splice loss, and map fiber IDs to GIS or CAD systems. A strong QC routine builds trust with project managers and ISPs alike.</p><p>---</p><p>👷 Training the Next Generation</p><p>A big part of my job is mentoring new technicians. Ribbon splicing isn’t something you master overnight — and it’s very different from single-fiber work.</p><p>I developed step-by-step workflows to teach:</p><p>Safe fiber handling</p><p>Clean ribbon cleaving</p><p>Tension control during splice alignment</p><p>Watching a trainee go from breaking strands to completing a perfect 12-count splice? That’s one of the most rewarding feelings in this trade.</p><p>---</p><p>Final Thoughts</p><p>Ribbon fiber isn’t going anywhere — and demand is only rising with each BEAD-funded project and rural expansion initiative.</p><p>As field engineers, we’re not just workers — we’re craftsmen, mentors, and infrastructure builders. We owe it to ourselves and our communities to bring precision, patience, and pride to every tray we touch.</p><p>If you’re working on ribbon projects — or just getting started — feel free to reach out. I’m always happy to share tools, advice, or just a story from the trenches.</p><p>– Sergii Zhulid<br>Denver, Colorado<br>Fiber Splicing Supervisor &amp; QC Inspector</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=a2a94cd5ba47" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>