<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Uzay Bengi on Medium]]></title>
        <description><![CDATA[Stories by Uzay Bengi on Medium]]></description>
        <link>https://medium.com/@uzay.bengi?source=rss-6f934d830769------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/1*kIP96zcDZ5z5_Fj45mi6Tg.jpeg</url>
            <title>Stories by Uzay Bengi on Medium</title>
            <link>https://medium.com/@uzay.bengi?source=rss-6f934d830769------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Fri, 27 Nov 2026 19:53:58 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@uzay.bengi/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[AI-Based Closed-Loop Automation for Energy Efficiency and Resilience in Mobile Networks]]></title>
            <link>https://medium.com/turkcell/ai-based-closed-loop-automation-for-energy-efficiency-and-resilience-in-mobile-networks-3fb605c23c1f?source=rss-6f934d830769------2</link>
            <guid isPermaLink="false">https://medium.com/p/3fb605c23c1f</guid>
            <category><![CDATA[5g]]></category>
            <category><![CDATA[energy-efficiency]]></category>
            <category><![CDATA[energy]]></category>
            <category><![CDATA[ai]]></category>
            <category><![CDATA[resilience]]></category>
            <dc:creator><![CDATA[Uzay Bengi]]></dc:creator>
            <pubDate>Tue, 23 Dec 2025 10:18:37 GMT</pubDate>
            <atom:updated>2025-12-25T12:11:59.193Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*fUMAkawdoBRp_ELdGAMvZg.png" /></figure><p><strong>Introduction and Motivation</strong></p><p>The rapid evolution of mobile communication networks is driven by the increasing demand for diverse services, users, and connected devices. Beyond traditional performance metrics, modern networks are now evaluated by their <strong>sustainability</strong> and <strong>resilience </strong>capabilities. High traffic volumes and dense infrastructure deployments make energy consumption a primary operational concern, directly impacting both expenditures and environmental footprints.</p><p>In literature, there are various approaches for both issues. Some of the proposed methods for energy efficiency include advanced sleep modes, traffic-aware resource allocation, virtualization, and cloud-based architectures. Even though such mechanisms may reduce energy consumption, they are often designed with static assumptions or require manual configurations. As a result, their effectiveness is limited when network conditions change rapidly or unexpectedly particularly during critical occurrences like natural disasters.</p><p>In addition to energy efficiency case, network resilience has an increasing importance. Power outages, network failures, extreme weather events, and sudden traffic surges may severely disrupt service availability. Traditional resilience strategies typically rely on overprovisioning and redundancy. Even if they are effective, these approaches introduce additional energy consumption and increase deployment and operational complexity.</p><p>Energy efficiency and network resilience are often treated as competing objectives. Saving energy usually involves switching off or scaling down network resources, whereas ensuring resilience requires maintaining additional capacity available. Existing network architectures offer limited flexibility to balance these objectives dynamically, especially under real-time constraints.</p><p>Furthermore, another limitation lies in the centralized nature of data processing and control. Cloud-centric architectures often require data to be transported over long paths, which increases energy consumption and introduces vulnerability to intermediate failures. Moreover, human-driven network operations struggle to react fast enough to complex, multi-dimensional events that span radio, transport, and power domains.</p><p><strong>The Role of AI and Closed-Loop Automation</strong></p><p>These challenges motivate a shift toward intelligent, AI-driven network control. By employing learning and decision-making capabilities in the network, it becomes possible to adapt resource usage continuously based on real-time observations. Offline-trained models may learn and adapt complex behaviors, while online execution enables rapid and consistent responses to changing conditions.</p><p>Closed-loop automation plays a key role in this vision. Instead of relying on predefined rules, the network observes its own state, decides on optimal actions, applies them automatically, and learns from the outcome. This approach allows energy efficiency and resilience to be addressed jointly rather than separately.</p><p>In this concept, there occur two main use case scenarios. These scenarios clearly illustrate how AI-based automation can be applied to real operational challenges. One scenario addresses service continuity during power-related disruptions, while the other targets energy savings during periods of low network load. Together, they highlight a practical path toward more sustainable and resilient mobile networks.</p><p><strong>Use Case 1: Resilience-Oriented Disaster Recovery Automation Application</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/947/1*drsTwyCOquXvFzcVKGuJvg.png" /></figure><p><strong>Methodology Overview</strong></p><p>The first use case addresses network operation under power failure conditions. The goal is to extend site availability during prolonged outages while maintaining essential services.</p><p>The system relies on two main data sources. The first includes sector-level information, such as battery lifetime and voltage. These parameters describe the physical constraints of the site. The second source is time-series KPI data, including traffic volume, service usage, and drop rates, which reflect current network demand. These heterogeneous data streams are processed through a preprocessing layer and are cleaned, aligned, and normalized.</p><p>This processed data feeds an AI-driven decision module. The core of this module is a simulation environment that evaluates different service configurations under power constraints. The model learns how to sequence actions, such as locking specific carriers, in order to prolong battery lifetime while minimizing service degradation.</p><p><strong>Decision Logic and Operational Flow</strong></p><p>The operational flow begins when the site is in a normal state. If a power-related alarm is detected, the system does not react immediately. Instead, a confirmation timer is started. This step prevents unnecessary actions caused by short and temporary power fluctuations.</p><p>If the alarm clears within this confirmation window, the system returns to normal operation. If the alarm persists, the AI model is activated. Before taking any action, the model retrieves the latest sector and KPI data to reflect the current situation accurately.</p><p>Based on this real-time information, the system selects an appropriate service state. These states range from full operation to progressively more energy-saving configurations, including a survival mode that preserves only essential connectivity.</p><p>A key element of the design is the rollback mechanism. Once normal power conditions are restored, all temporary actions are automatically reversed. The site returns to its original configuration without manual intervention.</p><p>This closed-loop approach ensures that resilience actions are applied only when needed and removed as soon as conditions improve.</p><p><strong>Use Case 2: Energy-Aware RAN Optimization with Closed-Loop Control</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*reqmXkc46JgHwPcl310fFQ.png" /></figure><p><strong>Methodology Overview</strong></p><p>The second use case focuses on reducing energy consumption during low-traffic periods, without compromising user experience. It targets radio access network components with high idle power consumption, such as massive MIMO base stations.</p><p>The system operates as a continuous closed-loop automation process. Performance data from the network is collected and analyzed in near-real-time. This data includes traffic load, signal quality indicators, and hardware-level counters such as power consumption and resource utilization.</p><p>An AI agent evaluates the observed network state and determines the optimal configuration. Representative actions include adjusting antenna configurations or activating different sleep modes.</p><p>Once a decision is made, it is automatically enforced through the network management interface. At the same time, monitoring systems provide visibility into the impact of the action. This allows continuous assessment of both energy savings and service quality.</p><p><strong>Operational Scenario</strong></p><p>During low-traffic periods, such as nighttime, the system detects a sustained drop in resource utilization while maintaining good signal conditions. The AI agent identifies an opportunity for optimization and applies a reduced antenna configuration.</p><p>This action reduces power consumption without affecting user experience. The successful outcome generates a positive reward, reinforcing the learned policy. As traffic conditions change, the system adapts automatically and restores capacity when needed. Through continuous learning and execution, the network becomes self-adaptive and energy-aware.</p><p><strong>Conclusion</strong></p><p>These two use cases demonstrate complementary aspects of intelligent network automation. One focuses on maintaining essential services under extreme conditions. The other targets long-term energy efficiency during routine operation.</p><p>Both rely on the same core principles: real-time data awareness, AI-based decision-making, and closed-loop execution. Together, they show that resilience and sustainability can be addressed jointly through intelligent automation, without relying on static rules or manual intervention.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=3fb605c23c1f" width="1" height="1" alt=""><hr><p><a href="https://medium.com/turkcell/ai-based-closed-loop-automation-for-energy-efficiency-and-resilience-in-mobile-networks-3fb605c23c1f">AI-Based Closed-Loop Automation for Energy Efficiency and Resilience in Mobile Networks</a> was originally published in <a href="https://medium.com/turkcell">turkcell</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Building Intelligent and Resilient Smart Utility Communication Systems with 5G and IoT]]></title>
            <link>https://medium.com/turkcell/building-intelligent-and-resilient-smart-utility-communication-systems-with-5g-and-iot-52d167ceb059?source=rss-6f934d830769------2</link>
            <guid isPermaLink="false">https://medium.com/p/52d167ceb059</guid>
            <category><![CDATA[smart-meter]]></category>
            <category><![CDATA[resilient]]></category>
            <category><![CDATA[5g]]></category>
            <category><![CDATA[smart-cities]]></category>
            <category><![CDATA[network-slicing]]></category>
            <dc:creator><![CDATA[Uzay Bengi]]></dc:creator>
            <pubDate>Mon, 22 Dec 2025 08:29:43 GMT</pubDate>
            <atom:updated>2025-12-23T07:15:52.620Z</atom:updated>
            <content:encoded><![CDATA[<p>In today’s world, the digital transformation of critical utility infrastructures has become a key priority as urban environments become more complex. The modernization of this transformation increasingly depends on reliable, energy-efficient, and flexible communication systems. Smart gas, water, and electricity metering applications require continuous data collection, long device lifetimes, and the ability to respond rapidly to any anomaly or emergency situations. These requirements challenge traditional communication approaches, especially when devices are deployed in hard-to-reach locations and are expected to operate for years without maintenance.</p><p>To address these challenges, recent smart utility architectures combine cellular IoT technologies with software-driven network capabilities. By integrating low-power devices, cloud-based IoT platforms, and next-generation mobile networks, it becomes possible to achieve both operational efficiency and infrastructure resilience.</p><p><strong>Concept and System Perspective</strong></p><p>The core concept of the proposed smart utility communication approach is based on an end-to-end view of connectivity, data processing, and service management. Instead of treating communication as a standalone component, the system is designed to align device behavior, network resources, and application requirements within a unified framework.</p><p>This unified framework is achieved through a layered system architecture:</p><ul><li><strong>At the device level</strong>, smart devices are optimized for transmitting data packets at scheduled intervals while maintaining the responsiveness necessary to act on urgent downlink commands.</li><li><strong>The network layer</strong> leverages cellular technologies to provide the broad connectivity and meticulous Quality of Service (QoS) management that critical utilities demand.</li><li><strong>Finally, the application enablement and vertical apps layer</strong> act as the system’s intelligence hub, where a centralized IoT platform aggregates incoming data to drive real-time monitoring, predictive analytics, and automated decision making.</li></ul><p>This layered design allows the system to adapt to different operational conditions without requiring fundamental changes to the deployed infrastructure. The figure below illustrates this system architecture:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*y0fQbXUUreqUbVhuUwn10g.png" /></figure><p><strong>Hybrid Use of Cellular Technologies</strong></p><p>One of the key aspects of the system is the use of multiple cellular access technologies to support diverse communication needs. Low-power wide-area technologies such as Narrowband IoT (NB-IoT) are well suited for large-scale smart metering deployments due to their extended coverage and low energy consumption. These characteristics make them ideal for battery-powered meters installed in basements, underground facilities, or dense urban environments.</p><p>At the same time, emerging 5G technologies introduce new capabilities that are valuable for critical utility services. Reduced-capability (RedCap) devices provide a balance between performance and complexity, enabling moderate data rates, lower latency, and native access to 5G core network features. This allows advanced network functions to be evaluated without relying on full-featured user equipment.</p><p>By supporting both technologies within the same ecosystem, the system can accommodate current deployment realities while remaining adaptable to future network evolution. The network architecture is shown in the figure below.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*MBIy-JM4zKRG53JB_NAKng.png" /></figure><p><strong>Network Slicing for Service Differentiation</strong></p><p>One of the most significant advancements enabled by 5G is network slicing. Network slicing allows a single physical network to be logically partitioned into multiple virtual networks, each optimized for a specific service type or performance requirement.</p><p>In smart utility scenarios, communication traffic is often predictable and periodic. However, critical situations like natural disasters, gas leakages require immediate and prioritized responses. In order to overcome this type of critical events, network slicing is proposed. Network slicing addresses this by isolating critical utility traffic from other services and assigning dedicated resources based on predefined policies.</p><p>Through slice-aware admission control and quality-of-service configurations, devices assigned to a utility slice experience stable performance even when the network is under high load. Unauthorized or non-critical traffic can be restricted, ensuring that essential services remain unaffected. Experimental observations indicate that this approach provides improved reliability, consistent latency, and controlled resource usage compared to best-effort mobile network operation.</p><p><strong>Extended Discontinuous Reception (eDRX) for Energy Optimization</strong></p><p>While service differentiation improves reliability, long-term energy efficiency remains a fundamental requirement for smart metering devices. Extended Discontinuous Reception (eDRX) plays a crucial role in achieving this goal.</p><p>eDRX allows devices to significantly extend their sleep periods while maintaining periodic network reachability. Compared to the conventional discontinuous reception approach, eDRX reduces the frequency of active listening cycles, leading to lower power consumption. In contrast to the deep sleep modes where devices become unreachable, eDRX maintains a compromise between energy savings and responsiveness.</p><p>Many experimental and simulation analyses show that appropriately configured eDRX cycles can substantially extend battery lifetime without violating acceptable latency requirements for utility applications. This makes eDRX a practical and flexible mechanism for large-scale, long-term smart metering deployments.</p><p><strong>Toward Resilient Smart Utility Infrastructures</strong></p><p>The combined use of low-power IoT technologies, network slicing, and energy-efficient device operation demonstrates a practical application of resilient smart utility systems. Rather than relying on a single technology, the proposed approach leverages the strengths of both legacy and next-generation networks, which is especially relevant as networks continue to evolve from LTE toward 5G.</p><p>Low-power cellular IoT provides scalability and longevity, while 5G-enabled features introduce service awareness and performance isolation. Together, they support a communication framework capable of meeting the strict reliability and efficiency requirements of critical infrastructure services.</p><p>As smart cities continue to evolve, such hybrid and flexible communication architectures are expected to become essential components of sustainable and intelligent utility management systems.</p><p>#5G #LTE #NB-IoT #RedCap #ResilientNetworks #NetworkSlicing #eDRX #NextGeneration #SmartMetering</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=52d167ceb059" width="1" height="1" alt=""><hr><p><a href="https://medium.com/turkcell/building-intelligent-and-resilient-smart-utility-communication-systems-with-5g-and-iot-52d167ceb059">Building Intelligent and Resilient Smart Utility Communication Systems with 5G and IoT</a> was originally published in <a href="https://medium.com/turkcell">turkcell</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
    </channel>
</rss>