<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by 400GDWDM on Medium]]></title>
        <description><![CDATA[Stories by 400GDWDM on Medium]]></description>
        <link>https://medium.com/@weizhouli?source=rss-ba00d9789206------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/0*E5nSybuSwT-NGFEP</url>
            <title>Stories by 400GDWDM on Medium</title>
            <link>https://medium.com/@weizhouli?source=rss-ba00d9789206------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Sat, 28 Nov 2026 20:34:46 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@weizhouli/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Optoelectronic Integration]]></title>
            <link>https://medium.com/@weizhouli/optoelectronic-integration-094b79f1b871?source=rss-ba00d9789206------2</link>
            <guid isPermaLink="false">https://medium.com/p/094b79f1b871</guid>
            <category><![CDATA[opto-electronic]]></category>
            <category><![CDATA[otn]]></category>
            <category><![CDATA[pda]]></category>
            <category><![CDATA[dwdm]]></category>
            <category><![CDATA[eml]]></category>
            <dc:creator><![CDATA[400GDWDM]]></dc:creator>
            <pubDate>Tue, 09 Jul 2024 08:54:05 GMT</pubDate>
            <atom:updated>2024-07-09T08:54:05.535Z</atom:updated>
            <content:encoded><![CDATA[<p><strong>(1) Monolithic photoelectric integration</strong></p><p>In recent years, silicon-based photonic devices have developed rapidly, such as optical switches, modulators, micro-ring filters, etc. The design and manufacturing technology of unit devices based on silicon technology has been relatively mature. By rationally designing and organically integrating these photonic devices with traditional CMOS processes, silicon photonic devices can be fabricated on the traditional CMOS process platform at the same time, thereby forming a monolithic integrated optoelectronic system with certain functions. However, the current optoelectronic integration technology still needs to address sub-micron etching technology, process compatibility between photonic devices and electronic devices, thermal and electrical isolation, integration of light sources, optical transmission loss and coupling efficiency, and optical logic a series of issues such as devices. The world’s first monolithic optoelectronic integrated chip based on standard CMOS manufacturing process, marking the future development of optoelectronic integrated chip to smaller size, lower power consumption and cost.</p><p><strong>(2) Hybrid optoelectronic integration</strong></p><p>Hybrid optoelectronic integration is the most studied optoelectronic integration solution at home and abroad. For system integration, especially for core lasers, InP and other III-V materials are a better technology choice, but the disadvantage is high cost, so it must be combined with a large number of silicon technologies to reduce costs while ensuring performance. In terms of the specific technical realization approach, take a company in the United States as an example, which combines active chips such as lasers, detectors, and CMOS processing in the form of different functional chipsets to common silicon through optical interconnection and electrical interconnection on passive optical adapter board. The advantage of this is that each chipset can be manufactured independently, the process is relatively simple, and the implementation is easy, but the integration level is relatively low. Universities and research institutions engaged in optoelectronic integration research have put forward optoelectronic integration technology solutions based on three-dimensional integration processes such as TSV interconnection, that is, SOI-based photonic integration layer and CMOS circuit layer realize system-level integration through TSV technology. Whether the two are compatible with each other in terms of design and structure, manufacturing processes, ensure low insertion loss of electrical interconnection, optical interconnection and optical coupling. This is the key to achieving hybrid optoelectronic integration and the main development of optoelectronic integration in the future direction.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/784/1*-8SxmUZ4YOFb3PtQmb9WLw.png" /><figcaption><a href="http://www.htfuture.com/">www.htfuture.com</a></figcaption></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=094b79f1b871" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[How Much Do You Know About 400G DAC and 400G AOC?]]></title>
            <link>https://medium.com/@weizhouli/how-much-do-you-know-about-400g-dac-and-400g-aoc-ccdfbcd1e7f8?source=rss-ba00d9789206------2</link>
            <guid isPermaLink="false">https://medium.com/p/ccdfbcd1e7f8</guid>
            <category><![CDATA[cad]]></category>
            <category><![CDATA[400g]]></category>
            <category><![CDATA[qsfp56]]></category>
            <category><![CDATA[caos]]></category>
            <category><![CDATA[200g]]></category>
            <dc:creator><![CDATA[400GDWDM]]></dc:creator>
            <pubDate>Thu, 06 Jun 2024 10:34:21 GMT</pubDate>
            <atom:updated>2024-06-06T10:34:21.067Z</atom:updated>
            <content:encoded><![CDATA[<p>Data centers, enterprises, and high-performance computing environments require flexible and well-defined <a href="https://www.htfuture.com/dacaoc-cables/">50G, 100G, 200G, and 400G cables </a>for interconnections within and between racks. With the development of 400G technology, 400G direct-connect cables suitable for short-distance data center interconnection have been mass produced and marketed, including 400G DAC and 400G AOC.<br>Currently on the market, 400G DAC and 400G AOC mainly have two packaging types: QSFP-DD and OSFP, both of which adopt 8×50Gb/s PAM4 electrical modulation format. In addition to the 400G direct-connect cable, there are 400G DAC high-speed branch cables and 400G AOC active branch cables, with a 400G connector at one end and several connectors of the same low rate at the other end (for a total rate of 400G).</p><p>The biggest difference between 400G DAC and 400G AOC is in the difference of transmission distance. The transmission distance of 400G DAC can only support 3m, while the transmission distance of 400G AOC can support 70m (OM3) or 100m (OM4). This is because they use different transmission media. 400G DAC USES copper cable as the transmission medium, while 400G AOC USES optical fiber as the transmission medium. In addition, 400G DAC and 400G AOC have the following differences:</p><p>• Available types — According to the current market situation, there are various types of 400G DAC, while 400G AOC active branch cable and QSFP-DD conversion 4*100G QSFP AOC has not entered the market for the time being. Therefore, 400G DAC can meet more connection demands relatively.<br>• Volume and weight — Optical fiber is smaller and lighter than copper core, so 400G AOC is smaller and lighter than 400G DAC. A 400G AOC is half the size of a 400G DAC, and weighs only a quarter as much. In addition, the bending radius of 400G AOC is less than 400G DAC.<br>• Anti-interference capability — as the core of 400G AOC is an optical fiber, which is an insulating material and non-conductive, it is not vulnerable to electromagnetic, lightning or radio signals during data transmission; But the 400G DAC cable is copper core, will conduct electricity, and therefore is vulnerable to lightning and other interference.<br>• Price — Since the price of optical fiber is generally higher than that of copper cable, the price of 400G AOC is usually higher than that of 400G DAC (prerequisite: same level or package). If the transmission distance of 400G DAC can meet your network needs, it is suggested that you can choose 400G DAC first, which can effectively save costs.</p><p><strong>Look to the future</strong><br>Both 400G DAC and 400G AOC are the most cost-effective solutions for interconnecting within or between racks, but for transmission distances greater than 100 meters, it is best to use a 400G optical module with a matching fiber (such as MTP-16 fiber jumper). With the commercialization and scale of 400G Ethernet, 400G QSFP-DD optical module and 400G OSFP optical module have successively entered the market and started mass production.<br><strong>Question about </strong><a href="https://www.htfuture.com/dacaoc-cables/"><strong>400G DAC/AOC</strong></a><br>Q: Why do 400G DAC/AOC adopt PAM4 modulation method?<br>A: Compared with NRZ modulation, PAM4 is a more effective modulation technique, which can effectively improve the bandwidth utilization. At the same baud rate, PAM4 has twice the spit and absorb capacity of NRZ. In other words, PAM4 can increase the network bandwidth without adding additional optical fibers, thus effectively improving the bandwidth utilization.<br>Q: What are the key technologies of <a href="https://www.htfuture.com/dacaoc-cables/">400G DAC/AOC</a>?<br>A: The key technologies of 400G DAC/AOC are PAM4 and DSP. Since PAM4 is more sensitive to noise than NRZ, especially in 400G AOC, DSP is introduced to compensate for this shortcoming of PAM4. As a high-speed digital processing chip, DSP can not only provide digital clock recovery function (PROVIDED by CDR), but also perform dispersion compensation operation to remove noise, nonlinear and other interference factors.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/779/1*LLgbv-Gyh_AVP70vT3xuuw.png" /></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=ccdfbcd1e7f8" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Classification of Fiber Optic Transceivers]]></title>
            <link>https://medium.com/@weizhouli/classification-of-fiber-optic-transceivers-3c11f906d029?source=rss-ba00d9789206------2</link>
            <guid isPermaLink="false">https://medium.com/p/3c11f906d029</guid>
            <category><![CDATA[dwdm]]></category>
            <category><![CDATA[cwdm]]></category>
            <category><![CDATA[optical-transceiver]]></category>
            <category><![CDATA[converter]]></category>
            <category><![CDATA[sfp]]></category>
            <dc:creator><![CDATA[400GDWDM]]></dc:creator>
            <pubDate>Thu, 06 Jun 2024 10:19:00 GMT</pubDate>
            <atom:updated>2024-06-06T10:19:00.549Z</atom:updated>
            <content:encoded><![CDATA[<p>With the diversified development of optical fiber transceiver products, their classification methods are also different, but there is a certain correlation between the various classification methods.<br>By rate<br>It can be divided into single 10M, 100M, 1000M, 10G <a href="https://www.htfuture.com/optical-module-transceiver/">optical fiber transceivers</a>, 10/100m adaptive, 10/100/1000m adaptive optical fiber transceivers.<br>Most of the single 10M, 100M and 1000M transceiver products work in the physical layer, where the transceiver products work bit-by-bit to forward data.<br>This forwarding mode has the advantages of fast forwarding speed and low delay, and is suitable for the fixed rate link. While 10/100M and 10/100/1000M optical fiber transceivers work at the data link layer and use the store-and-forward mechanism. In this way, each packet received by the forwarding mechanism should read its source MAC address, destination MAC address and data net charge, and the packet will be forwarded after CRC cyclic redundancy check is completed.<br>Store-and-forward benefits way can prevent some wrong frame transmission in the network, take up valuable network resources, but also is a good way to prevent the packet loss due to network congestion, when data link saturation can store and forward will not be able to forward data in the cache in the transceiver (first, wait for forwarding network idle again. This not only reduces the possibility of data conflict but also ensures the reliability of data transmission. Therefore, 10/100M and 10/100/1000M optical fiber transceivers are suitable for working on the link with variable rate.<br>According to the way of work to divide<br>As mentioned above, it can be divided into optical fiber transceivers working at the physical layer and optical fiber transceivers working at the data link layer.<br>Divided by structure<br>It can be divided into desktop type (independent) optical fiber transceiver and rack type optical fiber transceiver. Desktop type optical fiber transceiver is suitable for single user (and built-in power transceiver and external power transceiver), such as to meet the upper connection of a single switch in the corridor. Racking fiber transceiver is suitable for multi-user convergence. For example, the central computer room of the community must meet the upper connection of all switches in the community. The use of the rack is easy to realize the unified management and unified power supply of all modular fiber transceivers.<br>Divide by optical fiber<br>It can be divided into multimode fiber transceiver and single-mode fiber transceiver. Depending on the optical fiber used, the transceivers can transmit different distances. Multimode transceivers typically transmit between 2 and 5 kilometers, while single-mode transceivers can cover ranges from 20 to 120 kilometers.<br>It should be pointed out that the transmitting power, receiving sensitivity and wavelength of optical fiber transceivers themselves will be different due to the different transmission distances. For example, the transmitting power of the 5km optical fiber transceiver is generally between -20 ~ -14dB, the receiving sensitivity is -30dB, and the wavelength of 1310nm is used. Whereas, the transmitting power of 120km optical fiber transceivers is mostly between -3 ~ 0dB, the receiving sensitivity is less than -36dB, and the wavelength of 1550nm is used.<br>Divide by the number of optical fibers<br>It can be divided into single <a href="https://www.htfuture.com/optical-module-transceiver/">fiber transceiver</a> and double fiber transceiver. As the name suggests, a single-fiber device can save half of the optical fiber, that is, data can be received and sent on a single optical fiber, which is very useful in places where fiber resources are limited. Such products adopt the technology of wavelength division multiplexing, which mostly uses the wavelengths of 1310nm and 1550nm for short distance transmission (0–60km) and 1490nm and 1550nm for long distance transmission (60km-120km). With the increasing use of single fiber optic transceivers, the products have become mature and stable.<br>Divide by power supply<br>It can be divided into built-in power supply and external power supply. The built-in switching power supply is a carrier-class power supply, while the external transformer power supply is mostly used in civil equipment. The advantage of the former is that it can support ultra-wide power supply voltage, better realize voltage regulation, filtering and equipment power protection, and reduce external fault points caused by mechanical contact. The advantage of the latter is the small size of the equipment, easy to use the 14-slot rack centralized management and low price.<br>In addition, from the type of power supply voltage of the equipment, there are AC 220V, 110V, 60V; DC -48V, 24V, etc.<br>Press network management to divide<br>It can be divided into network tube type fiber optic transceiver and non — network tube type fiber optic transceiver. With the development of network to be operable and manageable, most operators hope that all the equipment in their network can be managed remotely. Fiber optic transceiver products, like switches and routers, are also developing in this direction gradually. The fiber-optic transceivers with network management can also be subdivided into local network management and client network management. <a href="https://www.htfuture.com/optical-module-transceiver/">The fiber-optic transceivers</a> that can be managed at the bureau end are mainly rack type products, which mostly adopt the master-slave management structure, that is, a master network management module can series N slave network management modules, and each slave network management module regularly polls the status information of all fiber-optic transceivers on its sub-rack and submits it to the master network management module. On the one hand, the main network management module needs to poll the network management information on its own rack, and on the other hand, it needs to collect all the information from the sub-rack, and then summarize and submit it to the network management server.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/660/1*19ACmEidkGcuDrSCWWhjJQ.png" /></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=3c11f906d029" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Compact Optical Module]]></title>
            <link>https://medium.com/@weizhouli/compact-optical-module-8a3b746b2da1?source=rss-ba00d9789206------2</link>
            <guid isPermaLink="false">https://medium.com/p/8a3b746b2da1</guid>
            <category><![CDATA[caos]]></category>
            <category><![CDATA[cad]]></category>
            <category><![CDATA[sfp]]></category>
            <category><![CDATA[csfp]]></category>
            <category><![CDATA[high-speed-cable]]></category>
            <dc:creator><![CDATA[400GDWDM]]></dc:creator>
            <pubDate>Sat, 25 May 2024 02:07:10 GMT</pubDate>
            <atom:updated>2024-05-25T02:07:10.199Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/325/1*Oll1ckIBvnd16YbyJUzijw.png" /><figcaption><a href="https://www.htfuture.com/optical-module-transceiver/">https://www.htfuture.com/optical-module-transceiver/</a></figcaption></figure><p>As we all know, optical module is one of the most important active devices in optical transmission equipment. Optical module is a photo electronic module for photoelectric and electro-optical conversion, which plays the role of photoelectric signal conversion. With the rapid development of the network market, the optical module has also been evolving. Now compact optical modules, which are mainly small packages, have been widely popularized and welcomed by the public.</p><p><strong>What is compact optical module？</strong><br>Compact optical module is a hot-plug small package module packaged by SFP. Its main function is to convert the electric signal at the sending end into the optical signal and transmit it out. After receiving the information, the optical signal is restored to the electrical signal at the receiving end. Compact optical module is mainly composed of laser (including transmitter TOSA and receiver ROSA), circuit board IC and external accessories, which are composed of shell, base, PCBA, ring, clasp, unlocking piece and rubber plug.</p><p><strong>What are the types of compact optical modules?</strong><br>(1) According to the rate of classification: 155M/622M/1.25 G/2.125 G/4.25G/8 G/10G. 155M and 1.25G are used more in the market.<br>(2) According to the classification of wavelength: 850nm/1310nm/1550nm/1490nm/1530nm/1610nm. Wavelength of 850nm is multimode; with the transmission distance under 2km. 1310/1550nm wavelength is for single mode, transmission distance above 2km.<br>(3) According to the distance classification: short distance, medium distance, long distance.<br>(4) According to the transmission mode: electrical interface, single mode, multimode.<br>(5)The special type of compact optical module also includes: BIDI-SFP, electrical interface SFP, CWDM SFP, DWDM SFP, SFP+ optical module and so on.</p><p><strong>Structure and principle of compact optical module</strong><br>Compact optical module is mainly composed of TOSA module, ROSA module and PCBA board according to hardware classification. The following is the structure and principle of optical module.<br>1. Optical emission module TOSA. Optical emission module is the main component of optical emission module, in which the light source laser diode is the core.<br>2. Receiving component ROSA, the function of the receiving component is to convert the weak optical signal after transmission into electrical signal, and to amplify and reshape the original input electrical signal. The receiving component, ROSA, is composed of a photo detector and a front (Trans resistive) amplifier and other components enclosed in a tight structure. The commonly used ROSA is PIN-TIA and APD-TIA.<br>3. PCBA board. PCBA is composed of optical emission circuit and receiving circuit.</p><p><strong>Can compact optical module be used in SFP+ slot?</strong><br>Compact optical modules can run in SFP+ slots, but SFP+ optical modules cannot run in compact light slots. SFP+ ports generally do not support speeds below 1G. In other words, we cannot insert 100BASE SFP optical module on SFP+ port. In fact, for this problem, it depends a lot on the switch model.<br>However, SFP+ optical modules are not automatically compatible to 1G to support SFP optical modules. Unlike copper SFP available in 10/100/1000 automatic compatibility, optical fibers such as SFP and SFP+ do not support automatic compatibility. Although it is possible to use a compact optical module on the SFP+ port in many cases, this does not mean that its insertion into the SFP+ port automatically supports 1G. In a fiber optic link, it may not work if we insert the compact optical module on one SFP+ port (1G) and then on the other SFP+ port (10G).<br>When use compact optical modules and SFP+ optical modules in a network, make sure that both ends of the fiber link have the same speed. The compact optical module can be used in the SFP+ port, but the compact optical module cannot be connected to the SFP+ optical module.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/378/1*dsmWMqYK4qV7SDEecD4GCA.png" /></figure><p><strong>Compact optical module and SFP+ DAC high-speed cable difference</strong><br>(1) Compact optical module supports a variety of protocols and applications, such as 100M Ethernet and gigabit Ethernet (GBE), fiber channel (FC), dual channel and bidirectional transmission of synchronous fiber network (SONET). The transmission medium of the compact optical module is single mode fiber (SMF), multi-mode fiber (MMF) and copper cable. Among them, multi-mode fiber can support the 1000base-sx port type in the application of 1GbE.<br>(2) High-speed SFP+ DAC cable is a passive twin-spindle cable assembly, and directly connected to the SFP+ module. SFP+ direct connection has a fixed length cable, usually 3, 5 or 7 meters in length, using small size cable and small size SFP+ optical module, with the advantages of low power, low cost and low delay. The architecture of the TOR switch has become one of the directions in virtualizing data centers. As the server density of each cabinet increases, the number of interconnections between the server and the access switch increases, the distance is shortened, and the delay is greatly reduced. At this time, the advantage of low cost and power consumption of 10G SFP+ DAC direct connection mode can be best reflected.</p><p><strong>The difference between compact optical module and GBIC optical module, SFP+ optical module</strong><br>(1) Compact optical module is to solve the problem of GBIC optical module volume is too large, its function and GBIC optical module similar, the volume is only half of the latter, more suitable for high-density wiring. In addition, the compact optical module USES LC interface (GBIC optical module USES SC interface), which is to be used together with LC optical fiber jumper. Its transmission rate varies from 100Mbps to 4Gbps, and the transmission distance can reach hundreds of kilometers.<br>(2) Compact optical module is the same shape of SFP+ optical module, SFP+ optical module is the upgraded version of the compact optical module, and their main difference is the speed.</p><p><strong>Note for use of compact optical module and SFP+ DAC high-speed cable</strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/403/1*Xoc-tl7bfxeAb-i4N8k0lg.png" /><figcaption><a href="https://www.htfuture.com/dacaoc-cables/">https://www.htfuture.com/dacaoc-cables/</a></figcaption></figure><p><strong>Notes for use of compact optical module</strong><br>(1) When take the optical module, do not touch the metal connection part of the compact optical module, so as not to damage the optical module.<br>(2) When insert compact optical module, confirm the compact optical module is attached to the handle of the compact optical module electro-optical port and then insert.<br>(3) If just out of the compact optical module, do not unplug the light mouth dust plug, directly inserted.<br>(4) When pull out the compact optical module, first pull out the fiber line, pull the handle to the position of about 90 degrees and slowly pull out, pull out when pulling out cannot be too hard or pull out the handle is not in place, may cause damage to the compact optical module shield.</p><p><strong>SFP+ DAC high-speed cable use note</strong><br>(1) When insert SFP+ DAC high-speed cable, you need to push the SFP+ cable module along the horizontal direction gently into the slot, until close contact with the slot.<br>(2) When take out the SFP+ DAC high-speed cable, pull the pull ring outward along the horizontal direction to make the cable module unlock, and pull out the cable, at the same time with the hand against the SFP+ module iron shell.<br>(3) Do not excessive bend, twist the cable in the process of insertion, otherwise it will cause permanent damage.<br>(4) Do not let the fiber tail is right on your eyes. Do not look into the fiber. Do not see the fiber tail directly or use instruments, laser is not visible, but may cause permanent damage to the human eyes.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=8a3b746b2da1" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[The battle between CWDM and DWDM: which is friendlier to MAN?]]></title>
            <link>https://medium.com/@weizhouli/the-battle-between-cwdm-and-dwdm-which-is-friendlier-to-man-25602d1a595c?source=rss-ba00d9789206------2</link>
            <guid isPermaLink="false">https://medium.com/p/25602d1a595c</guid>
            <category><![CDATA[otn]]></category>
            <category><![CDATA[cwdm]]></category>
            <category><![CDATA[dwdm]]></category>
            <category><![CDATA[sfp]]></category>
            <category><![CDATA[backbone]]></category>
            <dc:creator><![CDATA[400GDWDM]]></dc:creator>
            <pubDate>Sat, 11 May 2024 08:56:11 GMT</pubDate>
            <atom:updated>2024-05-11T08:56:11.585Z</atom:updated>
            <content:encoded><![CDATA[<p>As is known to all, CWDM and DWMD are closely related, both of which adopt <a href="https://www.htfuture.com/ht6000-dwdmotn-transmission-platform/">WDM technology</a> and can simultaneously transmit multiple optical wave lengths in a single fiber. However, CWDM is suitable for short distance transmission, while DWDM is suitable for long distance transmission. In addition, there is also a big difference in power consumption and cost.</p><p><strong>Power consumption</strong><br>In general, whether CWDM system or DWDM system, use the passive components, the power consumption of the system the difference between the different main source of light module, and CWDM module’s power consumption is usually lower than light DWDM optical module’s power consumption, such as optics CWDM Wan Zhao light module maximum power consumption is 1.2W, and DWDM SFP+ light module in 0~70℃ under the working temperature of maximum power consumption is 1.5W, in -40~85℃ under the working temperature of maximum power consumption is 1.8W, so relatively CWDM system power consumption is lower than the DWDM system power consumption.</p><p><strong>The cost</strong><br>The cost difference between CWDM and DWDM systems is mainly reflected in hardware and operating costs.</p><p>With the increase of the total number of wavelength multiplexed and the increase of single channel transmission rate, power consumption becomes a key factor in the circuit board design of the system. Compared with DWDM system, CWDM system without refrigerated laser has low power consumption and can effectively save cost.</p><p>Although DWDM and CWDM are using DFB laser as light source, but the DWDM to prevent wavelength drift caused by temperature changes to the filter channel <a href="https://www.htfuture.com/mux-demux/">multiplexer and demultiplexer,</a> need to use cooling technology (that is, the cooler) to control the temperature change and stable wavelength, sometimes, also can use wavelength lock to ensure the accuracy of wavelength and stability, and CWDM don’t need cooling, such as wavelength locking technology, greatly reduces the cost of equipment, the current CWDM system costs usually only 30% of the cost of DWDM system.</p><p>By above knowable, CWDM technology and DWDM technology has the same principle, relative to the latter and the former has the advantages of low cost, low power consumption, etc. As a result, the CWDM technology construction of metropolitan area network or the network capacity is one of the most effective and the most economic choice can greatly reduce network cost, adapt to constantly enrich and increase of the business, to solve the problem of the ratio of the expansion and metropolitan area network construction.</p><p><strong>HTF is based on the present, looking to the future</strong><br>With the substantial increase of network communication data volume and the<a href="https://www.htfuture.com/ht6000-dwdmotn-transmission-platform/"> increasing capacity of optical communication network</a>, CWDM technology will become an ideal low-cost solution for MAN construction due to its low cost, flexible topology and multiple access service types. HTF based on the existing business needs and requirements for the future network development, launched a one-stop optical transmission network system, including the CWDM coarse wavelength division multiplex, CWDM coarse sparkling points multiplexer, CWDM optical module (e.g., CWDM SFP, CWDM SFP+), etc., can provide reliable for operators, flexible, efficient and low cost solution.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/573/1*SrMX02EMFTf_sm24WPO_qw.png" /><figcaption><a href="http://www.htfuture.com/">www.htfuture.com</a></figcaption></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=25602d1a595c" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Frequently Asked Questions About Deploying SFP+ DAC High Speed Cables]]></title>
            <link>https://medium.com/@weizhouli/frequently-asked-questions-about-deploying-sfp-dac-high-speed-cables-f313156517e9?source=rss-ba00d9789206------2</link>
            <guid isPermaLink="false">https://medium.com/p/f313156517e9</guid>
            <category><![CDATA[dac-high-speed-cable]]></category>
            <category><![CDATA[cwdm]]></category>
            <category><![CDATA[cad]]></category>
            <category><![CDATA[dwdm]]></category>
            <category><![CDATA[caos]]></category>
            <dc:creator><![CDATA[400GDWDM]]></dc:creator>
            <pubDate>Sat, 11 May 2024 08:16:15 GMT</pubDate>
            <atom:updated>2024-05-11T08:16:15.872Z</atom:updated>
            <content:encoded><![CDATA[<p><strong>(1) How to choose the passive </strong><a href="https://www.htfuture.com/dacaoc-cables/"><strong>SFP+ DAC high-speed cable </strong></a><strong>and active cable</strong><br>The passive SFP+ DAC high speed cable contains no electrical components and therefore requires little power supply to operate. Instead, active cables require dc power to integrate their signal processing circuits into their built-in connectors, making them more expensive to use. Therefore, when the distance is less than 7 meters, it is recommended to use passive SFP+ DAC high-speed cable; when the distance is more than 7 meters, the use of active cable is more appropriate.</p><p><strong>(2) Can use SFP+ DAC compatible high-speed cable on Cisco switch</strong><br>Yes, just like compatible optical modules, compatible SFP+ DAC high-speed cables will be built to the same industry manufacturing standards as cisco’s high-speed cables, and each eligible SFP+ DAC high-speed cable will be tested with cisco equipment to ensure the network runs smoothly. By buying the SFP+ DAC high-speed cable from a reliable manufacturer, you can buy brand-quality products and save money at the same time.</p><p><strong>(3) Can the </strong><a href="https://www.htfuture.com/dacaoc-cables/"><strong>SFP+ DAC high-speed cable</strong></a><strong> be used in the SFP port?</strong><br>SFP+ DAC high-speed cable can be backwards-compatible with SFP ports to ensure the normal operation of the network. However, the SFP DAC high-speed cable is not compatible with the SFP+ port. The SFP DAC high-speed cable can be plugged into the SFP+ port, but not for the 10G data transfer rate.</p><p><strong>How do I deploy </strong><a href="https://www.htfuture.com/dacaoc-cables/"><strong>SFP+ DAC high-speed cables</strong></a><strong> in a data center?</strong><br>SFP+ DAC high-speed cable is a connection cable for realizing high-speed interconnection communication over short distances. It is widely used in data centers and server rooms. To make your SFP+ DAC high speed cable work, here’s how to deploy the SFP+ DAC high speed cable in your data center.</p><p><strong>(1) Calculate the length of </strong><a href="https://www.htfuture.com/dacaoc-cables/"><strong>SFP+ DAC high-speed cable</strong></a><strong> in advance</strong><br>When deploying the SFP+ DAC high-speed cable in an 84-inch, 45RU cabinet, it is conservatively estimated that the cable length from the top to the bottom of the cabinet is approximately 7 feet (2.1m) and the cable length between the two adjacent ports is approximately 1.5 feet (0.45m). If a cabinet has two ToR switches and 20 2U SFP+ NIC servers, the maximum required SFP+ DAC high-speed cable should be 2.1+2×0.45≈3m. At this point, you can purchase 3m SFP+ DAC high-speed cable.</p><p><strong>(2) Do not exceed the bending radius of the SFP+ DAC high-speed cable</strong><br>When deploying an SFP+ DAC high speed cable, make sure the cable is within the minimum bending radius standard. Each SFP+ DAC high speed cable has a different minimum bending radius according to the USA wire gauge.</p><p><strong>(3) Protect your </strong><a href="https://www.htfuture.com/dacaoc-cables/"><strong>SFP+ DAC high-speed cable</strong></a><strong> with management tools</strong><br>In order to prevent SFP+ DAC high speed cables from sagging due to excessive load, it is necessary to use cable management or stress relief tools. The stress relief tool can not only ensure that the bending radius of the <a href="https://www.htfuture.com/dacaoc-cables/">SFP+ DAC high-speed cable</a> is maintained within the normal range, but also facilitate the cable path to be orderly and orderly. At the same time, the cable management tool such as the harness can be used to tie the high-speed cable harness to the stress relief tool, which is conducive to securing the cable.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/577/1*JT32doQrflLlh7HIsm1vQg.png" /><figcaption><a href="http://www.htfuture.com/">www.htfuture.com</a></figcaption></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=f313156517e9" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[CWDM VS DWDM: Which Is the Better Choice?]]></title>
            <link>https://medium.com/@weizhouli/cwdm-vs-dwdm-which-is-the-better-choice-517729c41aed?source=rss-ba00d9789206------2</link>
            <guid isPermaLink="false">https://medium.com/p/517729c41aed</guid>
            <category><![CDATA[cwdm]]></category>
            <category><![CDATA[backbone]]></category>
            <category><![CDATA[wdm]]></category>
            <category><![CDATA[network]]></category>
            <category><![CDATA[dwdm]]></category>
            <dc:creator><![CDATA[400GDWDM]]></dc:creator>
            <pubDate>Sun, 28 Apr 2024 10:20:07 GMT</pubDate>
            <atom:updated>2024-04-28T10:20:07.639Z</atom:updated>
            <content:encoded><![CDATA[<p><strong>CWDM VS DWDM: Which Is the Better Choice?</strong><br>Now the MAN business continues to enrich the MAN capacity requirements are also increasing. However, in the construction of MAN, due to the limited transmission resources of operators that have laid optical fiber, it is necessary to find new solutions to <a href="https://www.htfuture.com/ht6000-dwdmotn-transmission-platform/">increase the bandwidth capacity</a> of MAN.<br>WDM technology — a good helper to solve the problem<br>In recent years, with the substantial improvement of <a href="https://www.htfuture.com/ht6000-dwdmotn-transmission-platform/">backbone network capacity</a> and access network capacity, the capacity bottleneck of the network has been gradually transferred to the MAN, so the construction of broadband MAN is gradually becoming the hot spot of telecom and network construction.<br>Due to its relatively small geographical area, relatively concentrated population and other factors, people are faced with short transmission distance, wide band, flexible access, diverse and complex business problems.</p><p><strong>Short transmission distance</strong><br>Compared with backbone network, the service transmission distance in MAN is shorter and more sensitive to cost.</p><p><strong>Flexible access mode</strong><br>With the increase of business innovation, the speed of business generation is faster and faster, the user needs are more and more difficult to grasp, the MAN needs to have enough flexibility, scalability and rapid response ability to adapt to changing needs.</p><p><strong>With Eric</strong><br>With the increase of users, the growth of service bandwidth, as well as the development of interactive network television (IPTV), video monitoring and other types of Internet broadband applications, to the MAN caused huge bandwidth pressure and business management pressure, the MAN expansion and upgrade is imminent.</p><p><strong>Business is diverse and complex</strong><br>Man should not only carry the traditional time division multiplexing (TDM) business, Internet business, but also consider the rising IPTV, next generation network (NGN), 5G (fifth-generation mobile communication), peer-to-peer network (P2P), enterprise <a href="https://www.htfuture.com/ht6000-dwdmotn-transmission-platform/">broadband applications </a>and other emerging business.<br>Therefore, considering the transmission distance, capacity and service type of MAN, it is an inevitable trend to gradually introduce WDM into LAN to solve the bandwidth bottleneck of MAN.</p><p><strong>How does CWDM technology apply in MAN?</strong><br>At present, CWDM technology is relatively mature and the product is relatively simple. It can be applied in the access layer and convergence layer of MAN, but cannot be used in the core layer. Because the 2.5Gbit/s carrying service rate and 8-wave capacity of the CWDM system in the core layer of the MAN cannot fully meet the network requirements of the core layer of the MAN, and for the access layer and convergence layer of the MAN, the number of required wavelengths is generally no more than 8, most of the current CWDM systems can provide 8 wavelengths.<br>At the same time, in the local network, there are often some situations where the transmission distance is long and the fiber resources are limited. The low-cost characteristics of CWDM system can be maximized when the transmission distance is between 0 and 50km, so the CWDM system can truly show its competitive advantage under the urban edge network and the local network.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/576/1*gDrATDmFRMM1g5vkF4UzkQ.png" /><figcaption><a href="https://www.htfuture.com/ht6000-dwdmotn-transmission-platform/">https://www.htfuture.com/ht6000-dwdmotn-transmission-platform/</a></figcaption></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=517729c41aed" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Application of DAC High Speed Cable in Data Center]]></title>
            <link>https://medium.com/@weizhouli/application-of-dac-high-speed-cable-in-data-center-6f8946b22b7b?source=rss-ba00d9789206------2</link>
            <guid isPermaLink="false">https://medium.com/p/6f8946b22b7b</guid>
            <category><![CDATA[cad]]></category>
            <category><![CDATA[sfp]]></category>
            <category><![CDATA[sfp28]]></category>
            <category><![CDATA[qsfp]]></category>
            <category><![CDATA[caos]]></category>
            <dc:creator><![CDATA[400GDWDM]]></dc:creator>
            <pubDate>Sun, 28 Apr 2024 03:14:34 GMT</pubDate>
            <atom:updated>2024-04-28T03:14:34.745Z</atom:updated>
            <content:encoded><![CDATA[<p><a href="https://www.htfwdm.com/direct-attach-twinax-cables-dacs/">DAC high speed cable</a> can be divided into 10G SFP+ DAC high speed cable, 25G SFP28 DAC high speed cable, 40G QSFP+ DAC high speed cable and 100G QSFP28 DAC high speed cable according to the different transmission rate, mainly used for data center short distance direct connection. At the same time, DAC high-speed cable in order to meet the needs of user network upgrade, 40G QSFP+ DAC high-speed cable and 100G QSFP28 DAC high-speed cable with branch cable packaging form, can be used in 40g-4 *10G, 100g-4 *25G network upgrade application scenarios.</p><p><a href="https://www.htfwdm.com/direct-attach-twinax-cables-dacs/"><strong>10G SFP+ DAC high speed cable</strong></a><br>The 10G SFP+ DAC high-speed cable is widely used for interconnect between 10G fiber optic network CARDS, interconnect between 10G ToR switches and servers, and stack of 10G Ethernet switches.<br>The 10G SFP+ DAC high-speed cable is based on the multi-source protocol of the pluggable small package optical transceiver module, and adopts the copper axis cable with SFP+ connector at both ends, which can provide a ten-gigabit Ethernet connection between the device (such as server, fiber network card, switch, etc.) and the SFP+ interface. In the past, RJ45 port or SFP port was used on the main board of the server. Now, with the development of big data and high bandwidth, 10G has become popular on the server.</p><p><a href="https://www.htfwdm.com/direct-attach-twinax-cables-dacs/"><strong>25G SFP28 DAC high speed cable</strong></a><br>The 25G SFP28 DAC high-speed cable is widely used in interconnection between 25G devices (such as servers, 25G fiber optic network CARDS, etc.) and in supercomputer scenarios.<br>The 25G SFP28 DAC high-speed cable follows the IEEE P802.3by Ethernet standard, which can provide users with 25G high-bandwidth data interconnection capability. Due to the late arrival of 25G Ethernet, the application of its related optical communication products has not been popularized. However, with the advent of 5G network, the demand for 25G for 5G pre-shipments will increase significantly.</p><p><a href="https://www.htfwdm.com/direct-attach-twinax-cables-dacs/"><strong>40G QSFP+ DAC high speed cable</strong></a><br>40G QSFP+ DAC high-speed cable as a direct connection between 40G switches, with a compact and independent 4-channel pluggable interface, can be downward compatible, suitable for 40G equipment stack and cascade; At the same time, in order to meet users’ needs for more connections, 40G QSFP+ to 4*SFP+ DAC high-speed cable and 40G QSFP+ to 4*XFP DAC high-speed cable came into being, realizing network upgrade between 10G and 40G devices.<br>As the server port rate is upgraded from 1Gbps to 10Gbps, the uplink from the access layer to the core layer is upgraded to 40Gbps/100Gbps in order to realize the basis of non-blocking full-line rate of the network. Since the cost of 40G fiber link is cheaper than 100G, most medium-sized enterprises choose 40G when building data centers.</p><p><a href="https://www.htfwdm.com/direct-attach-twinax-cables-dacs/"><strong>100G QSFP28 DAC high speed cable</strong></a><br>100G QSFP28 DAC high-speed cable has two interface types: QSFP28 to QSFP28 and QSFP28 to 4*SFP28, of which 100G QSFP28 to 4*QSFP28 DAC high-speed cable is suitable for stacking, cascade and direct connection between 100G devices over short distance, such as 100G switch, etc. QSFP28 to 4*SFP28 DAC high speed cable is suitable for interconnection between 100G and 25G equipment.<br>With the rapid growth of Internet data usage, video on demand (VOD), sharing the emergence of new type high bandwidth applications such as service, in order to meet the demand of higher bandwidth and greater network capacity, and global large data centers are on a 100G server link development, at this point, switch between stack from the earlier 10 GBPS upgraded to 100 GBPS.</p><p><a href="https://www.htfwdm.com/direct-attach-twinax-cables-dacs/"><strong>DAC high-speed cable</strong></a><strong> connection scheme within the frame</strong><br>DAC high speed cables are generally used for short distance direct connection between data center racks, with length of 1~7 meters being the best (up to 12 meters).<br>If your cabling scenario is also short-range, DAC high-speed cables are a good choice for cost reasons. HTF can provide 10G/25G/40G/100G DAC high-speed cable to help users connect devices more quickly and conveniently. For more details, please visit the official website of HTF or contact <a href="/service/mailto:info@htfuture.com">info@htfuture.com</a>.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=6f8946b22b7b" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[400ZR: Successfully Opens 400G for Next Generation Data Center Interconnection]]></title>
            <link>https://medium.com/@weizhouli/400zr-successfully-opens-400g-for-next-generation-data-center-interconnection-376f3d86693e?source=rss-ba00d9789206------2</link>
            <guid isPermaLink="false">https://medium.com/p/376f3d86693e</guid>
            <category><![CDATA[dwdm]]></category>
            <category><![CDATA[dci]]></category>
            <category><![CDATA[data-center]]></category>
            <category><![CDATA[idc]]></category>
            <category><![CDATA[network]]></category>
            <dc:creator><![CDATA[400GDWDM]]></dc:creator>
            <pubDate>Wed, 24 Apr 2024 10:37:07 GMT</pubDate>
            <atom:updated>2024-04-24T10:37:07.850Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/568/1*grdYogit6LE0Q4c0vagxtQ.png" /><figcaption><a href="http://www.htfuture.com/">www.htfuture.com</a></figcaption></figure><p>With the increasing demand for large-scale cloud services and data center storage and processing, data center systems are becoming more and more decentralized and therefore more difficult to manage. In addition, applications such as artificial intelligence (AI) urgently need low latency, high bandwidth network architectures to handle the large machine-to-machine input/output (I/O) requirements generated between servers. To ensure that these applications can be implemented, the maximum transmission distance between these distributed data centers must be limited to about 100km. So these data centers must be connected in clusters. In order to ensure the interconnection between high-bandwidth and high-density data centers, 400ZR was born. This paper will focus on introducing the definition, influence and development trend of 400ZR.</p><p><strong>What is 400ZR?</strong><br>400 ZR is a specification defined by <a href="https://www.htfuture.com/400g-otn-muxponder247/">the Optical Internetworking </a>Forum OIF (Optical Internetworking Forum) that USES a combination of dense wavelength division multiplexing (DWDM) and higher-order modulation to transmit 400 g over 80km of data center interconnection (DCI) links. The aim is to ensure long-term and stable implementation based on a single carrier of 400G. This single carrier uses complex polarization multiplexing with the 16-level orthogonal amplitude modulation (dp-16qam) at a rate of 60Gbaud.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/559/1*yikjilzV4EVQqyFGacVURQ.png" /></figure><p>400G ZR presents a unique and advanced coherent technology that drives a high-capacity data transmission solution. It is small, compact, hot-pluggable, and can be matched with 400GE switching ports. Although the external dimensions of the module are not specified in IA (Implementation Protocol), the optical Internet forum OIF has defined the dimensions of the module to accommodate<a href="https://www.htfuture.com/400g-otn-muxponder247/"> the 400G solution</a>. In addition, the Multi-source protocol (MSA) body has defined optical modules of the QSFP-DD and OSFP encapsulation types, which can be interlinked. In other words, since the OIF and MSA are industry-wide organizations, the marketed compliant 400ZR solution will also be interoperable. The interoperability of the 400ZR solution also brings the dual benefits of simplifying supply chain management and deployment.<br>The hot-pluggable coherent 400ZR scheme supports only 400G Ethernet interconnections and multi-vendor interconnections. It is not suitable for next generation 400G MAN transmissions over 80km. In this case, the 400ZR+ (400G ZR+) standard is proposed, which promises to further improve modularity by supporting a variety of channel capacities based on coverage requirements and compatibility with established MAN infrastructures.</p><p><strong>What will be the impact of 400ZR?</strong><br>Although the 400ZR technology is still in its infancy, it will have a major impact on three industries, including very large data centers, distributed campus networks and metropolitan area networks, and telecommunications providers.<br>1. The 400ZR helps cloud computing and very large data centers adapt to the increasing demand for high bandwidth<br><a href="https://www.htfuture.com/400g-otn-muxponder247/">Data center interconnections</a> and the development of the 400ZR can help cloud computing and very large data centers adapt to the growing demand for high bandwidth on the network. They can cope with the exponential growth of applications such as cloud services, Internet-of-things devices and streaming video. Over time, the 400G ZR will make a greater contribution to the growing number of applications and users across the network.<br>2. The 400ZR will support the connectivity of distributed data centers<br>As mentioned above, the 400ZR technology will support high bandwidth interconnections to connect distributed data centers. Through this connection, distributed data centers can communicate with each other, share data, balance workloads, provide backups, and expand data center capacity when needed.<br>3. The 400ZR will allow telecommunications companies to send back residential traffic<br>The 400G ZR standard will allow telecommunications companies to send back residential traffic. When running at 200Gb/s, the 400ZR can increase the range of high-loss transmissions using 64Gbaud heart and QPSK modulation. For 5G networks, 400G ZR can provide mobile backhaul by aggregating multiple 25Gb/s links, which is more conducive to promoting the expansion of the emerging 5G network market and application scope.<br>4. 400ZR+/400ZR- will provide more convenience on top of 400ZR<br>In addition to its interoperability with other modules, the 400ZR is expected to support additional operational modes, known as 400ZR+ and 400ZR-, to increase the range of addressable applications. The “+” indicates that the module’s power consumption exceeds the 15W required by IA and some pluggable devices, enabling the module to transmit over distances of hundreds of kilometers using more powerful signal processing technologies. “-” means that the module can support low rate modes such as 300G, 200G and 100G, providing more flexibility and convenience for network operators.</p><p><strong>How long will the 400ZR heat last?</strong><br>According to the 2019 OFC chief technology officer, a 400ZR product sample is expected to be seen on the 2020 OFC. At the OFC data center summit in 2019, Google, Microsoft and other industry giants announced plans to deploy the 400ZR within the next two years.<br>What’s more, in 2021–2024, the development of 400ZR technology will bring a great deal of demand for light modules. The following figure shows the sales of <a href="https://www.htfuture.com/400g-otn-muxponder247/">DWDM optical modules</a> in the market with high speed (above 100G) and low speed (below 100G). As can be seen from the table, the number of optical modules used in cloud computing or the interconnection of large data centers will increase from 2021 to 2024. In other words, starting from 2021, 400ZR will lead the growing demand for light modules.</p><p>In addition, with the implementation of the first 100Gbps serialize/desiccator on a switching chip in 2021, the transfer rate required for the optical interface will shift to 800Gbps in the next 1–2 years. OSFP dimensions have been defined to support a rate of 8x100GE without changing the type of optical module encapsulation. At the same time, the line-side coherent optics will transition to 128GBaud 16QAM support in the same amount of time, making it easy to upgrade from the current 400ZR to the next generation 800ZR. Therefore, 400ZR is crucial in both current and future network development.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=376f3d86693e" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[400G and 800G Development]]></title>
            <link>https://medium.com/@weizhouli/400g-and-800g-development-8312d8a544ae?source=rss-ba00d9789206------2</link>
            <guid isPermaLink="false">https://medium.com/p/8312d8a544ae</guid>
            <category><![CDATA[idc]]></category>
            <category><![CDATA[dwdm]]></category>
            <category><![CDATA[5g]]></category>
            <category><![CDATA[optical-network]]></category>
            <category><![CDATA[data-center]]></category>
            <dc:creator><![CDATA[400GDWDM]]></dc:creator>
            <pubDate>Tue, 23 Apr 2024 08:54:13 GMT</pubDate>
            <atom:updated>2024-04-23T08:54:13.289Z</atom:updated>
            <content:encoded><![CDATA[<p><strong>Comparison of advantages and disadvantages between different optical chips in 400G series optical modules:</strong><br>In terms of bandwidth, the current research on EML bandwidth has shown that it can reach 60GHz, while Silicon Photonics MZM can reach 50GHz.<br>Transmission rate, VCSEL is 100M in short distance, EML can support 2km, 10km and 40km. Silicon light has an advantage in 500M and 2 kilometers.<br>In terms of cost, EML is relatively more expensive. In terms of batch capacity, Silicon Photonics’ CMOS platform can achieve hybrid integration of optoelectronics, and high mass production capacity will be guaranteed.</p><p><strong>400G series optical module solution summary:</strong><br>The optical module products based on VCSEL chip have 400G SR8/SR4.2 products for short distance 100m; the optical module products based on EML chip are 100G, 100G DR1/FR1/LR1/ER1, 400G DR4/FR4, 400G LR4; based on MZM (SiPh) chip products are 100G DR1/FR1, 400G DR4, 400G-ZR.<br>Comparing the difference in power consumption and performance between the single-wave 100G silicon <a href="https://www.htfwdm.com/wdm-transport-platform/">optical solutions </a>and the EML solution, the single-wave 100G EML power consumption is 4.5W, and the single-wave 100G silicon optical solutions is controlled within 3.5W. At the same time, the two In terms of optical eye diagram performance, Silicon Photonics can also meet the performance requirements of single-wave 100G and 400G DR4. The advantage of Silicon Photonics lies in its high integration, which can integrate MZM+SSC+PD. Silicon Photonics has its shortcomings and large coupling insertion loss, which requires high-power CW and DFB.<br>400G DR4 EML compared with SiPh, 400G DR4 EML power consumption is 12W; 400G DR4 SiPhL power consumption is less than 10W. The advantage of DR4 Silicon Photonics is that it only needs two CW DFBs, supports multi-channel integration, 4CH MZM+SSC+4CH P, so it has advantages in power consumption and cost.<br><a href="https://www.htfwdm.com/wdm-transport-platform/">Data center optical interconnection DCI</a> demand is growing rapidly. Based on coherent technology, it has become the standard technical solution for 100GB/s, 200 GB/s, and 400 GB/s long-distance transmission. From the initial solution for ultra-long distance to the metropolitan area network the transmission market of the access network and the high-speed interconnection market between data centers, which has been of special concern in recent years, has been rapidly advancing the 400G ZR standard, and ZR+ is advancing.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/582/1*5kxbs8W787QdY0iDTEtYvA.png" /><figcaption><a href="http://www.htfuture.com/">www.htfuture.com</a></figcaption></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=8312d8a544ae" width="1" height="1" alt="">]]></content:encoded>