<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Stories by Ya Bouargane on Medium]]></title>
        <description><![CDATA[Stories by Ya Bouargane on Medium]]></description>
        <link>https://medium.com/@ya.bouargane?source=rss-2acd37eabf2f------2</link>
        <image>
            <url>https://cdn-images-1.medium.com/fit/c/150/150/0*QDIRDDrvWeIyjSO6</url>
            <title>Stories by Ya Bouargane on Medium</title>
            <link>https://medium.com/@ya.bouargane?source=rss-2acd37eabf2f------2</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Thu, 19 Nov 2026 11:05:09 GMT</lastBuildDate>
        <atom:link href="https://medium.com/@ya.bouargane/feed" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[From Idea to Object: Designing an Open Clip-On Force Sensor for Manual Laparoscopy]]></title>
            <link>https://medium.com/@ya.bouargane/from-idea-to-object-designing-an-open-clip-on-force-sensor-for-manual-laparoscopy-958b2a159541?source=rss-2acd37eabf2f------2</link>
            <guid isPermaLink="false">https://medium.com/p/958b2a159541</guid>
            <dc:creator><![CDATA[Ya Bouargane]]></dc:creator>
            <pubDate>Wed, 18 Nov 2026 00:03:25 GMT</pubDate>
            <atom:updated>2026-11-18T00:03:25.336Z</atom:updated>
            <content:encoded><![CDATA[<p>Why, how, what the simulation says, and what is likely to break first ?</p><p>By Yasmine Bouargane</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*oSUDVsdyjrRI4RhCRYAlOg.jpeg" /></figure><p><strong><em>Figure.1</em></strong><em> . Laparoscopic graspers: long rigid shafts. Photo: </em><a href="https://commons.wikimedia.org/wiki/File:Laparoscopic_Hand_Instruments_001_JPN.jpg"><em>ignis</em></a><em>, Wikimedia Commons, </em><a href="https://creativecommons.org/licenses/by-sa/3.0/"><em>CC BY-SA 3.0</em></a></p><h3>Overview: Separating Force from Heat in Laparoscopic Surgery</h3><h4>1. The Problem</h4><p>In minimally invasive surgery, procedures are performed through small ports, leaving surgeons with poor tactile feedback regarding the forces they apply. When an electrosurgical hook is activated, the instrument heats up significantly. Infrared studies show that a 5 mm hook can exceed <strong>120 °C</strong> over a 10 mm length of the shaft and remain above <strong>50 °C</strong> for at least 15 seconds post-activation. The metal shaft acts as a rigid lever between the surgeon’s hand and the tissue. When it heats up, thermal expansion distorts the force measurements, and no simple, open sensor currently exists to solve this.</p><h4>2. The Proposed Solution</h4><p>To overcome this, the article proposes a <strong>3D-printed sleeve</strong> that can be easily clipped onto any manual surgical instrument. The sleeve integrates <strong>four optical fibers</strong>:</p><ul><li><strong>Three fibers</strong> measure mechanical strain (the push and sideways force along the shaft).</li><li><strong>One dedicated fiber</strong> measures temperature exclusively, allowing thermal interference to be mathematically subtracted from the force-sensing fibers.</li></ul><h4>3. Simulation vs. Reality</h4><ul><li><strong>In Simulation (Theory):</strong> Theoretical models show that the sensor can measure sideways forces with a readout noise equivalent to just a few grams, provided that heat remains roughly uniform around the shaft.</li><li><strong>In Reality (Practice):</strong> Because no physical sensor of this kind currently exists, real-world performance remains unproven. Empirical testing is still required to handle uneven thermal gradients and identify structural failure points (i.e., what breaks first under stress).</li></ul><h3>1. The finding and the problem</h3><p>In laparoscopy, the surgeon works through small openings in the abdomen using long, stiff tools that pivot at the entry point, much like a pencil held in the middle by a tight rubber band. What the hand feels is a blurred version of what happens at the tip: friction, the push of nearby organs, everything blends together <a href="https://eprints.whiterose.ac.uk/213117/1/Development_of_Force_Sensing_Techniques_for_Robot-Assisted_Laparoscopic_Surgery_A_Review.pdf">[2]</a>.</p><blockquote><em>This loss of feel has measurable effects. In a surgical trial, adding vibrations to alert surgeons when they pushed too hard lowered both average and maximum forces during stitching, though it made little difference on simple object-moving tasks [3]. Animal studies also show that squeezing colon tissue with 20 to 50 newtons of force causes microscopic tissue damage depending on how long it is held [4]. However, because no clinical study directly proves that missing touch feedback causes surgical complications, this project makes no medical claims.</em></blockquote><blockquote><em>Force sensors do exist, just not in this format. They are built into the tips of specialized instruments [5], inside robotic jaws [6], as add-on kits for surgical robots [7], or as handheld attachments that only measure grip strength [8]. Based on our review, no open-source optical fiber sensor currently exists that simply clips onto a standard manual surgical tool.</em></blockquote><p>An optical fiber can act as a sensor. A pattern, the Bragg grating, is written in it and returns one precise color. When the fiber stretches, that color changes by a tiny amount, and that change is what we measure. Glass carries no current, which suits an operating room <a href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4029712/">[9]</a>. But the color also changes when the fiber warms, and electrosurgical forceps can exceed 300 °C <a href="https://katalog.lib.cas.cz/KNAV/EdsRecord/edsair,edsair.dedup.wf.001..7a73d08e3600d9531a3ef7e559afac54">[10]</a>. How can we tell whether the fiber was pulled or heated?</p><p>So we need to separate force from heat, stay precise enough for the measurement to be useful, and turn the whole into a real object.</p><h3>2. The idea</h3><p>This design relies on three core choices:</p><ol><li><strong>A clip-on sleeve:</strong> Instead of building a whole new instrument, the sensor sits in a 3D-printed sleeve that clips right onto standard tools, letting surgeons keep using what they already trust.</li><li><strong>Four optical fibers:</strong> Three fibers are glued down to measure both bending and heat, while a fourth is left loose to measure heat alone. This gives four data points to figure out four unknowns: pushing sideways, pushing forward or backward, and the temperature change.</li><li><strong>Open-source sharing:</strong> Publishing everything — the 3D models, code, parts list, and test plans — so anyone can build it, test it, and try to break the design.</li></ol><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*IgKVKQbC_wEuN1q0TbGfIw.png" /></figure><p><strong><em>Figure 2.</em></strong><em> Four fibers around the shaft. Three feel bending and heat. One feels heat alone.</em></p><blockquote><strong>What the idea brings</strong></blockquote><blockquote><strong><em>A fiber sensor</em></strong><em> that clips onto the manual instrument the surgeon already holds, instead of requiring a redesigned instrument.</em></blockquote><blockquote><strong><em>A thermometer fiber that separates heat from the push </em></strong><em>along the shaft and gives the temperature of the shaft. Sideways force stays readable despite uniform heat, thanks to the layout of the three other fibers.</em></blockquote><blockquote><strong><em>An error budget in grams</em></strong><em>: noise, tolerated uneven heating, calibration error.</em></blockquote><blockquote><strong><em>An open file made to be criticized:</em></strong><em> 3D model, code, test plan, expected problems.</em></blockquote><h3>3. Technical development</h3><p>The sleeve is a 3D-printed clip, 30 mm long and 9.2 mm wide for a 5 mm shaft (13.2 mm with the clamp tabs). Each glued fiber lies in a groove, with two windows for the adhesive. The thermometer fiber sits in a small loose tube, with grease that conducts heat: it follows the temperature of the shaft without being glued to it.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*yeI3fvITOPWV5dgqdUb9PA.png" /></figure><p><strong><em>Figure 3.</em></strong><em> The shaft, the sleeve (transparent) and the fibers. Blue: glued fibers. Orange: the thermometer fiber in its loose tube. Concept, not printed.</em></p><p>Inside each fiber, the Bragg grating acts as a mirror that returns only one color. The sleeve measures nothing: it holds those mirrors against the shaft, and their color does the talking. The force bends the shaft, the shaft stretches the glued fiber, the color shifts, and the readout instrument sees the shift.</p><p>To go from readings to forces, we need to know how much each fiber reacts to each cause (a push, a rise in temperature). Those reactions form a table of coefficients, obtained by calibration on a bench, which the code inverts. Without the thermometer fiber, a push along the shaft and a rise in temperature shift the three glued fibers by the same amount: the code can no longer tell them apart and refuses to compute <a href="https://github.com/yabouargane/fbg-force-sleeve"><strong><em>(details in the documentation of the repository).</em></strong></a></p><p>We also need an instrument that reads the color of each grating. A laboratory instrument is precise but expensive; a cheaper route converts the color change into a change of light, read by a photodiode, with lower precision, for dynamic measurements <a href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5676622/">[11]</a>; a force held for a long time also raises the question of drift. No part has been priced: the promise of low cost still awaits quotes.</p><p>The calibration procedure (known weights first, then heating the shaft) has only run on synthetic data.</p><h3>4. The simulation</h3><p>The simulation only tests the math: can three glued fibers and one loose thermometer fiber successfully separate force from heat, and how small is the error? It answers three key questions — is the fourth fiber actually needed, is the noise low enough to measure real forces, and what errors (like uneven heating or bad calibration) could ruin the results? However, it says nothing about the physical sleeve itself, such as its material, glue, or how it handles port friction, which can only be tested on a physical workbench. In short, the simulation proves the idea works on paper and points out what needs to be measured next.</p><p>The principle has three steps, like an exercise whose answer is known. We invent a situation: a force and a temperature that we choose. The code computes what the four fibers would read, with the noise of a real instrument. Then it recovers the force and the temperature from those readings alone, without seeing the answer. The gap with the chosen value is the error of the sensor. We repeat the exercise with a degraded setup: more noise, a wrong calibration, uneven heating. This tests the logic of the design, not a real sensor.</p><p>Because direct physical measurements weren’t available, the simulation makes three assumptions:</p><ol><li><strong>Shaft geometry:</strong> The shaft is a thin-walled steel tube (0.5 mm wall thickness), with force applied 100 mm away from the sensor sleeve [12].</li><li><strong>Thermal sensitivity:</strong> Steel expands more than glass when heated, stretching any fiber glued to it. As a result, a glued fiber shifts about 2.6 times more per degree than a loose fiber — estimated at <strong>30 pm/°C</strong> versus <strong>11.5 pm/°C</strong> for a loose fiber (~10 pm/°C in [14] ).</li><li><strong>Readout resolution:</strong> The lab-grade interrogator detects shifts down to <strong>1 pm</strong>, while the low-cost version detects <strong>3 pm</strong> (matching a published design). Forces are reported in grams-force (1gf = 0.0098N).</li></ol><p><strong>First Result: Decoupling Heat from Axial Force</strong> To test thermal decoupling, the shaft was heated by <strong>15 °C</strong> with zero applied force:</p><ul><li><strong>Axial force (push along the shaft):</strong> Without the thermometer fiber, the system mistakes heat for an axial push exceeding <strong>500 N</strong> (an average error of <strong>~360 N</strong>). Adding the thermometer fiber drops this error to <strong>3.3 N</strong> (pure readout noise) and recovers the true temperature within <strong>0.09 °C</strong>.</li><li><strong>Lateral force (sideways push):</strong> The thermometer fiber makes no difference here. Because the three glued fibers are spaced evenly at <strong>120°</strong> around the shaft, uniform heating affects them equally and cancels out naturally.</li></ul><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*vS0LSuXhyScq5CCslXV7uA.png" /></figure><p><strong><em>Figure 4. </em></strong><em>A 15 °C rise in temperature, with and without the thermometer fiber. Simulation with assumed parameters.</em></p><p>Second result: sideways forces are clear and readable. Think of the machine’s background noise like a digital kitchen scale that jitters by just 1 to 3 grams even when nothing is on it; compared to that tiny static, our 38 g target (0.375 N, or 12.5% of the 3 N range) is a large enough weight to easily cut right through the jitter. This goal is realistic because it is looser than a similar published sensor (under 0.15 N) [6] and matches the natural sensitivity of a human arm (8% to 13% depending on the joint) [15]. While this safety margin looks comfortable on paper, real-world glue absorbs some movement and passes on less than the full stretch in practice.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*mlnxI5qHYdbssRnAdE6k6g.png" /></figure><p><strong><em>Figure 5. </em></strong>Model noise versus the target, for the sideways force. Simulation with assumed parameters.</p><p>Third result: the push along the shaft is not readable, even once separated from heat. A tube stretches by a tiny amount under that load, and the noise is equivalent to about 313 g with the laboratory instrument and nearly 0.9 kg with the low-cost one. A bending element that amplifies the movement would be needed, and none is designed here.</p><p>The main danger is uneven heating. Uniform heat cancels out of the sideways readings; uneven heat does not: the fibers on the warm side stretch more and the sensor reads a push that does not exist, about 26 g for each degree by which the warm side exceeds the average. To stay under 38 g, the warm side must stay within about 1.5 °C of the average, and within 0.28 °C on an 8 mm tube.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*1_ghlKmsx-CmnV5AppjK8A.png" /></figure><p><strong><em>Figure 6.</em></strong> <em>How far the warm side can rise above the average before it fakes a push. Simulation with assumed parameters.</em></p><p>Finally, the thermometer fiber has to keep up with the shaft: if it lags by 1 °C, the axial reading is off by 34 newtons (the weight of about 3.5 kilograms), while the sideways readings stay clean. A 5% error in the calibration table gives 15 to 17 g of sideways error, and a model that allows for a curved response brings it from 12 g down to 3 g.</p><h3>5. Discussion, limits and problems to expect</h3><p>On paper, the noise is far below the target. The temperature will decide the real result: a side of the shaft 1 to 2 °C warmer than the average consumes the whole error budget.</p><p>The sleeve, wider than the instrument, does not pass through the port: it stays on the handle side. The strain there depends on what the port and the hand impose on the instrument as much as on the force at the tip. Getting back to the tip force requires a model of the pivot point <a href="https://image-ppubs.uspto.gov/dirsearch-public/print/downloadPdf/11413768">[16]</a>, which does not exist yet.</p><h3>What the thermometer fiber brings</h3><p>The thermometer fiber is essential for axial measurements because, without it, heat is incorrectly read as hundreds of newtons, whereas with it, the model tracks shaft temperature within 0.09 °C. However, for sideways forces, it adds nothing under uniform heat — since the 120° fiber layout already handles cancellation — and it cannot fix uneven heating because it only monitors a single point on the shaft. Its true value for sideways forces therefore remains to be proven in practice, such as accounting for real-world variations where individual glued fibers react differently to heat that the ideal computer model doesn’t capture.</p><h3>What is likely to break</h3><ol><li><strong>The thermometer fiber reacts too slowly to heat</strong></li></ol><ul><li><strong>Sign:</strong> Axial force readings drift during a heating test, even though sideways readings stay normal.</li><li><strong>Fix:</strong> Add more grease/contact surface, or use a second thermometer fiber.</li></ul><p><strong>2. The glued fibers expand differently than expected</strong></p><ul><li><strong>Sign:</strong> Real-world thermal expansion doesn’t match your calculation.</li><li><strong>Fix:</strong> Plug your actual measured value into the code and redraw Figure 5.</li></ul><p><strong>3. Heating is uneven across the shaft</strong></p><ul><li><strong>Sign:</strong> Sideways readings shift when only one side of the shaft gets hot.</li><li><strong>Fix:</strong> Measure temperature all around the shaft, or better insulate the fiber from the steel expansion.</li></ul><p><strong>4. The glue creeps (stretches slowly over time) or is too stiff</strong></p><ul><li><strong>Sign:</strong> The “zero point” drifts away from zero over time, or measured forces come out weaker than expected.</li><li><strong>Fix:</strong> Test different types of glue, or update your math model with real-world measurements.</li></ul><p><strong>5. The holding port (bushing) interferes with the reading</strong></p><ul><li><strong>Sign:</strong> The exact same push gives a different measurement with or without the support bushing attached.</li><li><strong>Fix:</strong> Build a mathematical model to account for how the pivot point affects the tool.</li></ul><p><strong>6. The 3D-printed plastic sleeve softens or the cheap reader is too noisy</strong></p><ul><li><strong>Sign:</strong> The PLA plastic starts warping near <strong>55–60 °C</strong> [17], or the low-cost reader bounces around too much.</li><li><strong>Fix:</strong> Heat-test a sample piece, and upgrade to a stronger material (like resin or nylon) or a better reader if needed.</li></ul><h3>Is it new?</h3><p>Parts of the idea exist: force-sensing modules made separately and built into the shaft <a href="https://image-ppubs.uspto.gov/dirsearch-public/print/downloadPdf/9952107">[18]</a>, fibers placed around a shaft (an arrangement cited without the exact reference having been found), and fiber kits <a href="https://scholar.hit.edu.cn/en/publications/development-of-the-x-perce-a-universal-fbg-based-force-sensing-ki/">[7]</a>. As far as the search shows, nobody has published a complete open fiber design that clips onto a manual instrument. The search covered web pages, patent summaries and code repositories, not patent claims: before anyone shares open plans, those claims have to be read.</p><h3>The technical file</h3><p>Everything needed to redo this work sits in an <a href="https://github.com/yabouargane/fbg-force-sleeve"><strong><em>open repository</em></strong></a>: the simulation code and its 13 tests, the script that generates the sleeve in 3D, the equations and assumptions of the model, a plan of seven tests, a calibration procedure and an issue template for anyone who wants to measure. The results can be recomputed with a few commands, and the file produced is identical to the one behind this article.</p><pre>pip install -r requirements.txt<br>python scripts/run_simulation.py<br>python scripts/make_results_summary.py</pre><p>The repository is incomplete: the sleeve has never been printed, the cable and the connector are not designed, no firmware exists and the license of the hardware is not chosen yet. The code was written with the help of an AI and checked by tests; read it before you rely on it. The code, the 3D model and the test plan are in <a href="https://github.com/yabouargane/fbg-force-sleeve">the open repository</a>. The full manuscript is not online yet.</p><h3>What next?</h3><p>The test plan has seven tests, from the noise at rest to a bushing that simulates the port. If the error stays above 38 g after calibration, or if the thermometer fiber does not track the shaft, the idea fails as designed, and the result will be published either way. The first test will be on the thermometer fiber.</p><p>If you work on fiber sensors, criticism of the thermal tests and of the model of the port would be welcome.</p><h3>Glossary</h3><ul><li><strong>Bragg grating (FBG):</strong> a pattern in an optical fiber that returns one color of light. The color shifts when the fiber stretches or warms.</li><li><strong>Picometer:</strong> a trillionth of a meter (10⁻¹² m).</li><li><strong>Calibration:</strong> measuring on a bench, with known loads and temperatures, how much each fiber reacts.</li><li><strong>Port (trocar):</strong> the tube through which an instrument enters the body.</li><li><strong>Gram-force:</strong> the weight of one gram, about 0.0098 newtons.</li><li><strong>Shaft</strong> is a rigid, cylindrical structural element — typically solid or tubular — used in engineering and mechanical systems to transmit force, torque, or motion, or to support other components (like gears, pulleys, or wheels).</li></ul><h3>References</h3><ol><li><a href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9085678/">Temperature profile and residual heat of monopolar laparoscopic and endoscopic dissection instruments (Surgical Endoscopy, 2021)</a></li><li><a href="https://eprints.whiterose.ac.uk/213117/1/Development_of_Force_Sensing_Techniques_for_Robot-Assisted_Laparoscopic_Surgery_A_Review.pdf">Development of Force Sensing Techniques for Robot-Assisted Laparoscopic Surgery: A Review</a></li><li><a href="https://link.springer.com/article/10.1007/s00464-024-10919-3">Tactile feedback in laparoscopic training, multicenter crossover trial (Surgical Endoscopy, 2024)</a></li><li><a href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6132882/">An in vivo analysis of safe laparoscopic grasping thresholds for colorectal surgery</a></li><li><a href="https://doi.org/10.1109/jsen.2019.2951782">Shi et al., High-sensitivity FBG-based distal force sensor for laparoscopic surgery (IEEE Sensors Journal)</a></li><li><a href="https://arxiv.org/abs/2211.05428">Chua and Okamura, A modular 3-DoF force sensor for robot-assisted minimally invasive surgery research (arXiv)</a></li><li><a href="https://scholar.hit.edu.cn/en/publications/development-of-the-x-perce-a-universal-fbg-based-force-sensing-ki/">X-Perce: a universal FBG-based force sensing kit (IEEE T-MRB, 2022)</a></li><li><a href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12772989/">ShaftFlex, TU Delft: a shaft-based grasping force add-on</a></li><li><a href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4029712/">Advances in bio-tactile sensors for minimally invasive surgery using the FBG force sensor technique: a survey (2014)</a></li><li><a href="https://katalog.lib.cas.cz/KNAV/EdsRecord/edsair,edsair.dedup.wf.001..7a73d08e3600d9531a3ef7e559afac54">TNO, The impact of electrosurgical heat on optical force feedback sensors (2008, abstract record)</a></li><li><a href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5676622/">Low-cost interrogation technique for dynamic measurements with FBG-based devices (Sensors, 2017)</a></li><li><a href="https://www.makeitfrom.com/material-properties/AISI-316-S31600-Stainless-Steel">AISI 316 stainless steel: material properties (MakeItFrom)</a></li><li><a href="https://journal.hep.com.cn/phos/EN/10.1007/s13320-022-0668-3">Strain-temperature cross-sensitivity of FBG strain sensors on different substrates (Photonic Sensors, 2022)</a></li><li><a href="https://www.researching.cn/ArticlePdf/m00005/2016/14/12/COL201614120007.pdf">Temperature and strain sensitivities of FBGs in single-mode fibers (Chinese Optics Letters, 2016)</a></li><li><a href="https://www-live.dfki.de/fileadmin/user_upload/import/6949_130808_Human_Force_Discrimination_during_Active_Arm_Motion_for_Force_Feedback_Design_Journal_Feyzabadi.pdf">Human force discrimination during active arm motion for force feedback design (IEEE Trans. Haptics)</a></li><li><a href="https://image-ppubs.uspto.gov/dirsearch-public/print/downloadPdf/11413768">Method of force estimation for a minimally invasive medical system (US 11,413,768)</a></li><li><a href="https://all3dp.com/2/pla-petg-glass-transition-temperature-3d-printing/">PLA and PETG glass transition temperatures (All3DP)</a></li><li><a href="https://image-ppubs.uspto.gov/dirsearch-public/print/downloadPdf/9952107">Ribbed force sensor, patent family (US 9,952,107)</a></li></ol><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=958b2a159541" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Decoding Surgical Precision: Using a 4x4 Matrix Digital Twin to Isolate Force and Temperature in…]]></title>
            <link>https://medium.com/@ya.bouargane/decoding-surgical-precision-using-a-4x4-matrix-digital-twin-to-isolate-force-and-temperature-in-61a2eea3a140?source=rss-2acd37eabf2f------2</link>
            <guid isPermaLink="false">https://medium.com/p/61a2eea3a140</guid>
            <dc:creator><![CDATA[Ya Bouargane]]></dc:creator>
            <pubDate>Mon, 02 Nov 2026 02:58:55 GMT</pubDate>
            <atom:updated>2026-11-02T02:58:55.933Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*Ryd1EW9pF3h6b8OLUTRxbg.jpeg" /></figure><h3>Decoding Surgical Precision: Using a 4x4 Matrix Digital Twin to Isolate Force and Temperature in FBG Arrays.</h3><p>Robot-assisted surgery has always involved a trade. The surgeon gets precision, a steady 3D view, and tremor filtering, but gives up the natural feel of tissue through the instrument. Surgeons learn to compensate visually, reading how tissue stretches and pales under a grasper.</p><p>That is starting to change. Intuitive’s da Vinci 5, cleared by the FDA in 2024, adds force-feedback instruments and redesigned hand controllers that let the surgeon feel push and pull forces at the console. In its own preclinical testing, Intuitive reports up to 43% less force on tissue with the feature. Intuitive frames this as a first step, with more haptic sensations to come.</p><p>Touch is not a solved problem, though, and for engineers the interesting question is what a sensor inside an instrument has to survive. Operating rooms are hostile. Electrosurgery floods the field with radio-frequency energy and heats metal, tissue, and everything touching them. A sensor that reads force beautifully on the bench has to keep reading it while the instrument warms up.</p><p>This article looks at one version of that problem: telling force apart from heat in a fiber-optic sensor. I built a small Python simulation to put numbers on it. Every number below comes from that model, and its parameters are illustrative. They are not any manufacturer’s specifications, and nothing here is a claim about how Intuitive’s instruments work.</p><h3>Why Fiber Optics?</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*WEZznC7xHTm-h2w5zyfTTg.jpeg" /></figure><p>A Fiber Bragg Grating (FBG) is a short stretch of optical fiber with a periodic pattern written into its core. It reflects one narrow wavelength:</p><p><strong><em>λB = 2neff × Λ</em></strong></p><p>where n <em>eff</em> is the effective refractive index and Λ is the spacing of the pattern. Stretch the fiber and the spacing changes. Heat it and both the spacing and the refractive index change. Either way, the reflected wavelength moves. Near 1550 nm, typical sensitivities are about 1.2 pm per microstrain and about 10 pm per degree for a bare fiber.</p><p>Three properties make FBGs attractive inside surgical instruments:</p><ul><li><strong>Size:</strong> The fiber is about 125 micrometer across, and many gratings can share one fiber.</li><li><strong>No electrical conductors:</strong> Glass does not pick up radio-frequency interference the way electrical strain gauges can, which matters next to electrosurgery.</li><li><strong>Proven in a clinical product:</strong> Intuitive’s Ion bronchoscopy system uses fiber-optic shape sensing along a 3.5 mm catheter, measuring its full shape hundreds of times per second. The company describes the sensor as thin, flexible, and not sensitive to metal objects.</li></ul><h3>The Bottleneck: An FBG Cannot Tell Strain from Temperature</h3><p>A grating reports exactly one number: its wavelength shift. Force and temperature both contribute to it, and nothing in the signal says which is which. Electrocautery heats the instrument, so the heat contribution arrives exactly when the surgeon is working on tissue.</p><blockquote>Analogy:<em> </em><strong><em>Imagine stepping onto a digital scale while wearing a heavy winter coat.</em></strong><em> The scale displays a total weight, but it can’t tell you how much of that weight is </em>you<em> and how much is the coat. In the operating room, electrosurgery is that heavy winter coat — it heats the metal shaft, causing it to expand and tricking the sensor into reporting a massive, phantom “force” that never actually happened.</em></blockquote><h3>The Solution: How We Subtract the “Coat”</h3><p>To isolate true mechanical force, we use two fundamental principles:</p><ol><li><strong>The Reference Core (The “Pure Thermometer”):</strong> We include an optical fiber that is thermally coupled to the shaft but isolated from mechanical strain (it floats freely). Because it experiences zero bending force, any wavelength shift it records is 100% due to temperature ( Δ T ).</li></ol><ul><li><em>Analogy:</em> This is like weighing the winter coat completely by itself on a separate hook so you know its exact weight.</li></ul><p><strong>2. The Differential Matrix (The Power of Multi-Core Geometry):</strong> Heat acts uniformly, when the shaft warms up, all bonded fibers expand by the exact same amount. Conversely, mechanical bending acts oppositely when the surgeon pushes the tip, one side of the tube stretches while the opposite side compresses.</p><p>By combining these signals into a 4×4 linear algebra matrix, the common mode (heat) cancels itself out, leaving only the differential signature of the mechanical force:</p><p>True Force = Total Signal — Thermal Reference</p><h3>The Build: A Python Digital Twin</h3><p>To test this logic, I built a Python digital twin that simulates raw optical corruption and runs a 4×4 decoupling matrix to clean the signal</p><figure><img alt="The equation Δλ=K ε ​ ⋅Δε+K T ​ ⋅ΔT models how a Fiber Bragg Grating’s measured wavelength shift responds linearly to both mechanical strain and temperature changes. Scaling this individual physical relationship across a four-element sensor array creates the 4×4 matrix system required to decouple thermal drift from mechanical force." src="https://cdn-images-1.medium.com/max/1024/1*MWDY6u7vEYjqdwPaSfvJFA.jpeg" /><figcaption>The equation Δλ=Kε⋅Δε+KT⋅ΔT models how a Fiber Bragg Grating’s measured wavelength shift responds linearly to both mechanical strain and temperature changes. Scaling this individual physical relationship across a four-element sensor array creates the 4×4 matrix system required to decouple thermal drift from mechanical force.</figcaption></figure><p>The forward model maps force and heat to wavelength shifts for each bonded fiber:</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/989/1*xwI50ACnJ8CyzzXVwVhVWg.png" /></figure><p>The simulation results clearly demonstrate the efficacy of the thermal decoupling algorithm in isolating true mechanical force from severe thermal interference. As illustrated in the output plot, the raw FBG signal <em>(red dashed line) </em>is heavily distorted and completely overwhelmed during the simulated electrocautery thermal spike, rendering uncorrected optical readings unreliable.</p><p>However, by applying the reference-based decoupling method, the thermal component is successfully subtracted from the readout in real time. The resulting reconstructed force curve <em>(green solid line) </em>tracks the true target force (black dotted line) with high fidelity, proving that multi-core optical sensors can maintain precision and deliver reliable haptic feedback even within thermally volatile surgical environments.</p><h3>Where it breaks</h3><p>1. The Asymmetric Heating Trap (Transverse Thermal Gradients)</p><ul><li><strong>The Problem:</strong> The 4×4 decoupling matrix assumes an <strong>isothermal cross-section </strong>meaning it assumes the entire shaft heats up evenly all the way around.</li><li><strong>Why it breaks:</strong> If an electrocautery tool touches only <em>one side</em> of the instrument, that side gets scorching hot while the opposite side stays cool. This temperature differential 0.8°C across the shaft at a 5% unevenness) looks mathematically identical to a mechanical bend.</li><li><strong>The Impact:</strong> It produces a 0.58N RMS error, scaling up to 1.16 N at 10% unevenness which is roughly the same magnitude as the actual surgical force being measured.</li><li><strong>Potential Fixes:</strong> Circumferential temperature reference arrays around the tube, real-time thermal modeling of the shaft, or using sensing elements that are thermally isolated from the main structure.</li></ul><p>2. Structural Rigidity and Strain Constraints</p><ul><li><strong>The Problem:</strong> Surgical instruments are built out of stiff materials (like stainless steel) to maintain structural integrity under load. Stiff materials resist bending, resulting in <strong>tiny micro-strains</strong>.</li><li><strong>Why it breaks / The Trade-off:</strong>On an 8 mm tube with fibers bonded 3.5 mm from the axis, 1 N of lateral force yields about 13με (15.7pm of optical shift). If you switch to <strong>multi-core fiber</strong> where the cores sit only about 35 micrometer from the axis, that same 1N force yields just 0.13 με (0.16 pm). Since the hardware has a noise floor of 1pm, it would take roughly 6 N of force just to overcome the noise.</li><li><strong>Axial Force Limitation:</strong> Axial load is even harder to capture 1 N of axial push produces less than half a picometre of shift on this tube, making axial force recovery entirely impractical with this setup.</li></ul><h3>Code</h3><p>The full script to reproduce the figure and the numbers above.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*SX12NzYfB1s0T6bwCTA-uA.png" /></figure><h3>Takeaways</h3><ul><li>Force feedback is arriving in surgical robots, and sensors inside instruments will have to work during electrosurgery.</li><li>Fiber Bragg gratings are electrically passive, but they respond to heat as strongly as to strain. In this model the heat signal was 16 times the force signal.</li><li>Reference fibers and multi-fiber matrices remove uniform heating well. Uneven heating and calibration errors are what remain.</li></ul><h3>Sources</h3><ul><li>Intuitive, “Force Feedback” newsroom page: <a href="https://www.intuitive.com/en-us/about-us/newsroom/force-feedback">https://www.intuitive.com/en-us/about-us/newsroom/force-feedback</a></li><li>Fierce Biotech, da Vinci 5 FDA clearance and the 43% preclinical figure: <a href="https://www.fiercebiotech.com/medtech/intuitive-launches-latest-da-vinci-robot-force-feedback-controls">https://www.fiercebiotech.com/medtech/intuitive-launches-latest-da-vinci-robot-force-feedback-controls</a></li><li>The Robot Report, da Vinci 5 design changes: <a href="https://www.therobotreport.com/the-intuitive-da-vinci-5s-top-design-changes-this-is-groundbreaking-for-robotic-surgery/">https://www.therobotreport.com/the-intuitive-da-vinci-5s-top-design-changes-this-is-groundbreaking-for-robotic-surgery/</a></li><li>Intuitive, Ion shape sensing: <a href="https://www.intuitive.com/en-us/products-and-services/ion/shape-sensing">https://www.intuitive.com/en-us/products-and-services/ion/shape-sensing</a></li><li>Intuitive, Ion system brochure (3.5 mm catheter, sensor properties): <a href="https://www.intuitive.com/en-us/-/media/ISI/Intuitive/Pdf/intuitive-ion-system-brochure-1051118.pdf">https://www.intuitive.com/en-us/-/media/ISI/Intuitive/Pdf/intuitive-ion-system-brochure-1051118.pdf</a></li><li>Poeggel S. et al., Sensors 2015, 15(7), 17115–17148, doi:10.3390/s150717115 (optical fiber sensors in medicine)</li></ul><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=61a2eea3a140" width="1" height="1" alt="">]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Sensing the Invisible: How Hair-Thin Optics Give Surgical Robots a Sense of Touch.]]></title>
            <link>https://medium.com/@ya.bouargane/sensing-the-invisible-how-hair-thin-optics-give-surgical-robots-a-sense-of-touch-12560e27e401?source=rss-2acd37eabf2f------2</link>
            <guid isPermaLink="false">https://medium.com/p/12560e27e401</guid>
            <dc:creator><![CDATA[Ya Bouargane]]></dc:creator>
            <pubDate>Sat, 17 Oct 2026 20:34:44 GMT</pubDate>
            <atom:updated>2026-10-24T20:54:15.650Z</atom:updated>
            <content:encoded><![CDATA[<h3>In a surgical instrument driven by cables, friction hides the force applied to the tissue. A Bragg grating etched into a glass fiber can measure it at the tip. How does this sensor work, and why is it not yet in the operating room?</h3><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*sW0aPKj_6emzZ7jAMliVIQ.jpeg" /></figure><p><strong>Photo 1.</strong> At the surgeon’s console of a da Vinci Si platform, the operator experiences zero force feedback from the instruments, relying entirely on a high-definition, enlarged 3D view to gauge tissue interaction. Photo: Staff Sgt. Bernardo Fuller, U.S. Army / DVIDS, public domain.</p><h3>The Problem: A Surgeon Who Cannot Feel</h3><p>Picture this: You are seated at a multi-million-dollar surgical console, peering into an enlarged 4K 3D display so sharp you can distinguish individual muscle fibers parting under the instrument tip. Your target is a fragile, pulsating 2 mm arterial wall that demands microscopic precision. You gently squeeze the hand controllers to tighten a crucial suture. Yet, your fingertips feel absolute emptiness, a total absence of mass, texture, and tension, gliding as if through open air.</p><p>When the robotic arm pinches, pulls, or stitches inside the patient, zero physical resistance reaches your hands. While robotic surgery systems have advanced significantly in visual clarity over the past twenty years, most platforms operate without direct force feedback. A dangerous paradox that modern optical engineering is finally racing to shatter.</p><p><strong>Photo 2.</strong> The master controllers of a da Vinci Xi console, where the surgeon places their fingers to drive the instruments. Photo: A.BourgeoisP / Wikimedia Commons, CC BY-SA 4.0.</p><p>As early as 2009, comprehensive reviews pinpointed patient-side force measurement as the single greatest bottleneck in surgical haptics: the challenge of transmitting true physical touch back to a surgeon’s hands [1]. Over fifteen years later, clinical surveys confirm that this sensation remains lost across most modern robotic platforms [2].</p><p>This article explores a promising hardware solution: using <strong>Fiber Bragg Grating (FBG) optical sensors</strong> to capture micro-forces directly at the instrument tip. Addressing this solution leads directly to the core engineering question: How can a very thin glass fiber measure a few tenths of a Newton at the tip of a cable-driven instrument, and what keeps it from working in an operating room?</p><p>What makes this challenge so compelling to me is how it bridges three distinct worlds: the fundamental physics of light, micro-sensor engineering, and the unforgiving precision of the operating room. At its core lies a profound question: <strong>How do you translate a microscopic shift in light wavelength into an immediate, trustworthy sensation inside a surgeon’s fingertips?</strong></p><p>To answer it, let us follow the path of the force, from the tissue to the displayed result, in six steps.</p><h3>Why Does the Cable Hide the Force?</h3><p>To keep the instrument thin enough, the motors must stay outside the body. They pull long cables that slide inside a flexible protective sheath all the way to the tool’s joint.</p><p>The problem is that the cable rubs against its sheath. It works just like a bicycle brake: the more bends the cable makes, the harder you have to pull for the force to reach the end. This friction changes constantly as the instrument moves inside the body because the shape of the sheath keeps shifting [3,4]. When the motion reverses, the tip doesn’t follow immediately this friction creates a slight mechanical lag, or “play” [3].</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*RTf3TYwaS4IT0eQm1o7Jog.jpeg" /></figure><p><strong>Photo 3.</strong> The patient cart of a da Vinci Xi robot, whose arms carry the instruments. Photo: Alvarogarciamd / Wikimedia Commons, CC BY-SA 4.0.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*Z0v-tYxjZkOjiuunPUryBA.png" /></figure><p><strong>Figure 1.</strong> Measuring at the motor means measuring the cable’s friction; measuring at the tip means measuring the tissue. Simplified diagram, not to scale.</p><h3>What the Sensor Must Be Able to Do</h3><p>Scientific literature [2] establishes clear design parameters for integrating force sensors into surgical instruments:</p><ul><li><strong>Size:</strong> Must maintain an overall diameter <strong>10 mm</strong> to pass through standard <strong>12—15 mm</strong> surgical entry ports.</li><li><strong>Force Range:</strong> Must measure up to <strong>20 N</strong> of grasping force for tasks like needle manipulation and knot tying. By contrast, a pinching force as large as 4 N can tear delicate soft tissue, while standard sutures snap under tension exceeding 4–6 N.</li><li><strong>Target Resolution:</strong> Requires a minimum detectable force step of <strong>0.06 N</strong> for direct haptic feedback to the hand, whereas <strong>0.2 N</strong> suffices for sensory substitution (visual force gauges displayed on screen).</li><li><strong>Sterilization Survival:</strong> Must endure steam autoclaving at <strong>120-135°C</strong>, a harsh thermal environment that routinely degrades conventional electronics, adhesives, and coatings.</li></ul><h3>How Does a Bragg Grating Work?</h3><p>An FBG is a very thin glass fiber whose core is etched with a pattern of repeated lines, like a microscopic barcode [5] (figure 2). This pattern sends back a single “color” of light, in a very narrow band, and lets all the others through.</p><p>Force doesn’t push directly on the light — it pushes on the glass. When the surgical robot presses against tissue, it stretches or compresses the hair-thin fiber.</p><p>This physical stretch pulls the microscopic lines of the barcode pattern apart (or pushes them closer together), which slightly changes the “color” (wavelength) of light sent back. By measuring this color shift, we are actually measuring <strong>strain</strong> (how much the glass stretched), which tells us the exact <strong>force</strong> applied.</p><p>The movement is microscopic: stretching the fiber by just one-millionth of its length shifts the reflected color by only about <strong>1 pm</strong> (picometer, which is a thousandth of a nanometer) [5, 6].</p><p>Think of it like a <strong>guitar string</strong>: when you tighten a string, its tension changes, altering the pitch of the note it plays. With an FBG, physical tension changes the spacing of the barcode, but instead of an acoustic note changing, the <strong>reflected optical color</strong> shifts.</p><p>Decoding these sub-nanometer shifts requires an <strong>optical interrogator</strong>, an instrument that shines a broad spectrum of light down the fiber and analyzes the returning signal.</p><p>The system operates in two stages:</p><p><strong>Signal Acquisition:</strong> A 512-pixel spectrometer or a tunable laser samples the reflected light spectrum in steps as fine as 5 to 156 pm.</p><p><strong>Peak-Tracking Analytics:</strong> Rather than relying solely on raw pixel data, a <strong>peak-tracking algorithm</strong> identifies the exact mathematical center of the spectral curve, delivering the final sub-Newton force precision [6].</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*UtgrBON74UTV6LHIF5Vwdw.png" /></figure><p><strong>Figure 2.</strong> Principle of the fiber Bragg grating sensor: the stretched fiber shifts the reflected wavelength.</p><h3>How Do You Turn a Fiber into a Force Sensor?</h3><p>A bare glass fiber cannot measure force on its own because light alone does not feel pressure. To solve this, we need a mechanical translator to convert physical force into fiber strain. The complete measurement chain operates through six sequential steps (figure 3):</p><ol><li><strong>The Interaction:</strong> The instrument tip contacts and exerts force on the patient’s tissue.</li><li><strong>Mechanical Deformation:</strong> A specially engineered structure at the tip (such as a flexible <strong>nitinol tube</strong>) bends or compresses slightly under that load.</li><li><strong>Fiber Strain:</strong> Because the FBG fiber is securely bonded to this structure, it stretches or compresses right along with it.</li></ol><p><strong>4 The Optical Shift:</strong> As the fiber deforms, the microscopic barcode pattern shifts, altering the <strong>reflected color</strong> of light.</p><p><strong>Signal Interrogation:</strong> The <strong>optical interrogator</strong> captures this color change by scanning the returning light spectrum.</p><p><strong>Data Processing:</strong> An underlying algorithm pinpoints the spectral peak, applies <strong>calibration formulas</strong>, corrects for <strong>temperature variations</strong>, and outputs a precise force value to the system.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/900/1*q8YId38si8ZxUyrFc3zaWg.png" /></figure><p><strong>Figure 3.</strong> The measurement chain, from force to result. The worked example (0.06 N, 34.14 pm/N) is detailed below; the calculation is illustrative.</p><p>Five published studies show different solutions (table 1):</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/1*chh-Z0IoV5YxSA3Ya8fovQ.png" /></figure><p><strong>Table 1. </strong>Five published fiber Bragg grating force sensors. Figures are not comparable: setups, ranges and protocols differ.</p><p>The sensors of Lai <em>et al.</em> [7, 8] tackle the problem at its source. Instead of measuring the force near the motor, where friction disturbs the measurement, they measure it at the very tip of the instrument, where the sheath is compressed almost as much as the cable is pulled.</p><p>Two cautions apply. The figures in the table cannot be compared: each team has its own setup, force range and protocol. And a good sensor is not enough: The FBG sensor mounted along the instrument’s shaft or tendon-sheath mechanism measures internal cable tension rather than the direct force applied by the jaws to the tissue, requiring a mathematical model to convert one to the other.. That costs accuracy: Lai <em>et al.</em> [11] report 0.37 N of error for the sensor alone and a root-mean-square error of 0.65 N for the force estimated on the other cables.</p><p><strong>Why is it so hard?</strong> Because the signal is tiny. With the sensor of Lai <em>et al.</em> [8], whose sensitivity is 34.14 pm per newton, a force of 0.06 N shifts the color sent back by only about 2 pm (0.06 N × 34.14 pm/N). That is nearly 40 times less than one spectrometer “pixel” (78 pm): the software must find the top of the curve far more finely than the raw reading. Noise sets the rest. In [8], the reading fluctuates by 6 pm even under constant load, that is 0.178 N. In [9], the interrogator cannot distinguish any change smaller than 1 pm, about 0.019 N.</p><h3>The Temperature Trap</h3><p>Glass is fundamentally vulnerable to heat: as temperature rises, it expands and its refractive index changes. This means the reflected “color” shifts even when zero force is applied.</p><p>Moving from an operating room at 22°C to a human body at 37°C causes a bare grating to shift by 150 to 205 pm. To a micro-sensor, this thermal shift mimics a fake force of 4 to 6 N — which is <strong>70 to 100 times larger</strong> than our target resolution of 0.06 N [5, 6, 8]. Left uncorrected, body heat completely drowns out the actual touch data.</p><p>Complicating matters further, mounting the fiber onto a physical structure changes its thermal behavior [12]. For instance, Lai et al. [8] discovered that a grating bonded to a metal tube shifts by <strong>21.37 pm/°C </strong>more than double the rate of a free, unbonded fiber <strong>10.61 pm/°C</strong>.</p><p><strong>1. The “Witness” Fiber (Reference Sensor):</strong> A helper fiber measures <em>only</em> temperature, so its reading can be subtracted from the main sensor [8]. For example, engineers put this extra fiber inside the stationary jaw of a robotic forceps [10, 13].</p><p><strong>2. Two Fibers with Different Stiffness:</strong> Two fibers are mounted on supports of different flexibility [9]. Because they experience the same heat but bend differently under pressure, math can separate the two signals — though this makes the overall sensor slightly less sensitive.</p><p><strong>3. The Smart Algorithm (AI Software):</strong> A neural network automatically processes the signal to separate force, position, and temperature on the fly [10].</p><p>These solutions have been tested in the laboratory. They add hardware, calibration and cost.</p><h3>Where Things Stand, and the Real Limits</h3><ul><li><strong>Accuracy</strong>: in Lai <em>et al.</em> [8], the reading error (0.178 N; 0.529 N for the compensated version) exceeds the target resolution of 0.06 N, and the second even exceeds the 0.2 N reference point. These are reading errors, not gaps against a reference force.</li><li><strong>Level of validation</strong>: bench tests, <em>in vitro</em> tests and an animal feasibility study [11]. None of the abstracts read reports a clinical trial in humans.</li><li><strong>Fixing the fiber</strong>: in Lai <em>et al.</em> [8], common glues creep (the wavelength drifts under constant load). A specific biocompatible glue solved the problem, but it can be scratched by neighbouring sheaths. According to Kuang <em>et al.</em> [12], an adhesive ages, and the thermal offset then becomes more uncertain.</li><li><strong>Sterilization</strong>, the most concrete limit: the autoclave runs at 121 °C or 132 °C [14], whereas the adhesive can come off above 120 °C [12]. None of the sources read reports a multi-cycle test of an FBG sensor. Lai <em>et al.</em> [8] judge the sterilisability of their sensor still to be evaluated and consider a disposable sensor. An Intuitive Surgical patent [13] describes this solution: a removable sensor, with only the instrument autoclaved. It is a manufacturer document, not a peer-reviewed study.</li><li><strong>Cost</strong>: the interrogator costs 10,000 to 100,000 dollars [2], and cable-driven instruments have a limited number of uses (10 originally, then 12 to 18 for some 8 mm models cleared in 2022 [15]). The sensor’s cost therefore weighs on every use.</li><li><strong>Clinical benefit</strong>: for the da Vinci 5 (cleared in March 2024, with optional “Force Feedback” instruments), the manufacturer reports up to 43 % less force on tissue in preclinical trials, without patient data. The press release does not describe the sensor, so it cannot be claimed to rely on FBGs [16]. A meta-analysis of 56 studies (768 participants) shows that haptic feedback reduces forces and improves accuracy, with smaller effects among experienced surgeons [17]. It deals with task performance, not with clinical outcomes in patients.</li></ul><h3>Open Questions</h3><ol><li>What is the end-to-end error on the force exerted at the jaws, under realistic conditions?</li><li>Can an FBG sensor withstand dozens of autoclave cycles without recalibration?</li><li>Can an interrogator be built that is compact and cheap enough for an operating room?</li><li>Does measuring less force suffice to reduce tissue trauma in the patient?</li></ol><h3>Conclusion</h3><p>The Bragg grating answers a precise problem: it measures force downstream of the cable’s frictional path, with a glass fiber and no electronics at the tip. The difficulty lies elsewhere: in bonding the fiber, in temperature, in the cost of reading it, and in surviving sterilization. The question is no longer so much whether light can measure force, but whether it can do so reliably, instrument after instrument, autoclave cycle after autoclave cycle.</p><h3>In Short</h3><p>The cable of a surgical instrument rubs and hides the force applied to the tissue. A Bragg grating sensor placed at the tip can measure it with a glass fiber and no electronics, but it must overcome temperature, the cost of reading it and sterilization. Current results come from laboratory, <em>in vitro</em> and animal tests: none of the abstracts read reports a clinical trial in humans.</p><h3>Mini-Glossary</h3><ul><li><strong>Haptic feedback</strong>: the sensation of force and touch given to the operator’s hand.</li><li><strong>Picometer (pm)</strong>: a thousandth of a nanometer; here, the unit of the color shift.</li><li><strong>Interrogator</strong>: the device that reads the color sent back by the Bragg grating.</li><li><strong>Autoclave</strong>: a sterilization device using steam under pressure.</li></ul><h3>Acknowledgements</h3><p>The photos come from DVIDS and Wikimedia Commons (credits under each image). This work relies on open resources (Europe PMC, arXiv, OpenAlex, Crossref, CDC, FDA, SEC).</p><h3>About the author</h3><p>Yasmine Bouargane. The Knowledge Society (TKS). I am interested in how fibre optic sensors can give surgical robots a sense of touch Contact:ya.bouargane@gmail.com</p><h3>References</h3><p>[1] A. M. Okamura, “Haptic feedback in robot-assisted minimally invasive surgery,” <em>Curr. Opin. Urol.</em>, vol. 19, no. 1, pp. 102–107, Jan. 2009, doi: <a href="https://doi.org/10.1097/MOU.0b013e32831a478c">10.1097/MOU.0b013e32831a478c</a>.</p><p>[2] A. H. Hadi Hosseinabadi and S. E. Salcudean, “Force sensing in robot-assisted keyhole endoscopy: a systematic survey,” <em>Int. J. Robot. Res.</em>, vol. 41, no. 2, pp. 136–162, 2022, doi: <a href="https://doi.org/10.1177/02783649211052067">10.1177/02783649211052067</a>.</p><p>[3] H. Wu, M. Yin, Z. Xu, Z. Zhao, and W. Han, “Transmission characteristics analysis and compensation control of double tendon-sheath driven manipulator,” <em>Sensors</em>, vol. 20, no. 5, Art. no. 1301, Feb. 2020, doi: <a href="https://doi.org/10.3390/s20051301">10.3390/s20051301</a>.</p><p>[4] T. N. Do, T. Tjahjowidodo, M. W. S. Lau, and S. J. Phee, “Performance control of tendon-driven endoscopic surgical robots with friction and hysteresis,” preprint, <a href="https://arxiv.org/abs/1702.02063">arXiv:1702.02063</a>, 2017.</p><p>[5] C. E. Campanella, A. Cuccovillo, C. Campanella, A. Yurt, and V. M. N. Passaro, “Fibre Bragg grating based strain sensors: review of technology and applications,” <em>Sensors</em>, vol. 18, no. 9, Art. no. 3115, Sep. 2018, doi: <a href="https://doi.org/10.3390/s18093115">10.3390/s18093115</a>.</p><p>[6] D. Tosi, “Review and analysis of peak tracking techniques for fiber Bragg grating sensors,” <em>Sensors</em>, vol. 17, no. 10, Art. no. 2368, Oct. 2017, doi: <a href="https://doi.org/10.3390/s17102368">10.3390/s17102368</a>.</p><p>[7] W. Lai, L. Cao, Z. Xu, P. T. Phan, P. Shum, and S. J. Phee, “Distal end force sensing with optical fiber Bragg gratings for tendon-sheath mechanisms in flexible endoscopic robots,” in <em>Proc. IEEE Int. Conf. Robot. Autom. (ICRA)</em>, May 2018, pp. 5349–5355, doi: <a href="https://doi.org/10.1109/ICRA.2018.8461090">10.1109/ICRA.2018.8461090</a>.</p><p>[8] W. Lai <em>et al.</em>, “Force sensing with 1 mm fiber Bragg gratings for flexible endoscopic surgical robots,” <em>IEEE/ASME Trans. Mechatronics</em>, vol. 25, no. 1, pp. 371–382, Feb. 2020, doi: <a href="https://doi.org/10.1109/TMECH.2019.2951540">10.1109/TMECH.2019.2951540</a>.</p><p>[9] S. Dong <em>et al.</em>, “Fiber Bragg grating based temperature-compensated force sensor development for minimally invasive surgery,” in <em>AOPC 2023: Optic Fiber Gyro</em>, Proc. SPIE, vol. 12968, Art. no. 129681B, Dec. 2023, doi: <a href="https://doi.org/10.1117/12.3007188">10.1117/12.3007188</a>.</p><p>[10] Q. Liang <em>et al.</em>, “A force/position measurement method of surgical forceps based on fiber Bragg gratings,” <em>IEEE Sensors J.</em>, vol. 23, no. 1, pp. 363–373, 2023, doi: <a href="https://doi.org/10.1109/JSEN.2022.3224042">10.1109/JSEN.2022.3224042</a>.</p><p>[11] W. Lai <em>et al.</em>, “An integrated sensor-model approach for haptic feedback of flexible endoscopic robots,” <em>Ann. Biomed. Eng.</em>, vol. 48, no. 1, pp. 342–356, 2020, doi: <a href="https://doi.org/10.1007/s10439-019-02352-8">10.1007/s10439–019–02352–8</a>.</p><p>[12] Y. Kuang, Y. Guo, L. Xiong, and W. Liu, “Packaging and temperature compensation of fiber Bragg grating for strain sensing: a survey,” <em>Photonic Sens.</em>, vol. 8, no. 4, pp. 320–331, Dec. 2018, doi: <a href="https://doi.org/10.1007/s13320-018-0504-y">10.1007/s13320–018–0504-y</a>.</p><p>[13] J. R. Steger, “Fiber Bragg grating end effector force sensor,” U.S. Patent 11 980 504 B2, Intuitive Surgical Operations, Inc., May 14, 2024. [Online]. Available: <a href="https://patents.google.com/patent/US11980504B2/en">Google Patents</a></p><p>[14] Centers for Disease Control and Prevention, “Steam sterilization,” in <em>Guideline for Disinfection and Sterilization in Healthcare Facilities (2008)</em>, page dated Nov. 28, 2023. [Online]. Available: <a href="https://www.cdc.gov/infection-control/hcp/disinfection-sterilization/steam-sterilization.html">https://www.cdc.gov/infection-control/hcp/disinfection-sterilization/steam-sterilization.html</a></p><p>[15] U.S. Food and Drug Administration, “510(k) Summary K214095: da Vinci X/Xi 8 mm reusable instruments,” Intuitive Surgical, Inc., decision of Aug. 15, 2022. [Online]. Available: <a href="https://www.accessdata.fda.gov/cdrh_docs/pdf21/K214095.pdf">https://www.accessdata.fda.gov/cdrh_docs/pdf21/K214095.pdf</a> .</p><p>[16] Intuitive Surgical, “Intuitive announces FDA clearance of fifth-generation robotic system, da Vinci 5,” press release (Exhibit 99.1), U.S. Securities and Exchange Commission, Mar. 14, 2024. [Online]. Available: <a href="https://www.sec.gov/Archives/edgar/data/1035267/000103526724000125/q124ex-991dv5fdaclearancex.htm">https://www.sec.gov/Archives/edgar/data/1035267/000103526724000125/q124ex-991dv5fdaclearancex.htm</a> .</p><p>[17] M. Bergholz, M. Ferle, and B. M. Weber, “The benefits of haptic feedback in robot assisted surgery and their moderators: a meta-analysis,” <em>Sci. Rep.</em>, vol. 13, no. 1, Art. no. 19215, Nov. 2023, doi: <a href="https://doi.org/10.1038/s41598-023-46641-8">10.1038/s41598–023–46641–8</a>.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=12560e27e401" width="1" height="1" alt="">]]></content:encoded>
        </item>
    </channel>
</rss>