<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0" xmlns:cc="http://cyber.law.harvard.edu/rss/creativeCommonsRssModule.html">
    <channel>
        <title><![CDATA[Sigra Australia - Medium]]></title>
        <description><![CDATA[Geoengineering Consultants and Specialists - Medium]]></description>
        <link>https://medium.com/sigra-australia?source=rss----9173f49d3ac7---4</link>
        <image>
            <url>https://cdn-images-1.medium.com/proxy/1*TGH72Nnw24QL3iV9IOm4VA.png</url>
            <title>Sigra Australia - Medium</title>
            <link>https://medium.com/sigra-australia?source=rss----9173f49d3ac7---4</link>
        </image>
        <generator>Medium</generator>
        <lastBuildDate>Sat, 28 Nov 2026 18:34:03 GMT</lastBuildDate>
        <atom:link href="https://medium.com/feed/sigra-australia" rel="self" type="application/rss+xml"/>
        <webMaster><![CDATA[yourfriends@medium.com]]></webMaster>
        <atom:link href="http://medium.superfeedr.com/" rel="hub"/>
        <item>
            <title><![CDATA[Balanced Pressure Drilling System deployed at Liang Tang Tunnel Project]]></title>
            <link>https://medium.com/sigra-australia/balanced-pressure-drilling-system-deployed-at-liang-tang-tunnel-project-b59f87d6ef62?source=rss----9173f49d3ac7---4</link>
            <guid isPermaLink="false">https://medium.com/p/b59f87d6ef62</guid>
            <category><![CDATA[civil-engineering]]></category>
            <category><![CDATA[infrastructure]]></category>
            <category><![CDATA[hong-kong]]></category>
            <category><![CDATA[tunnel-project]]></category>
            <dc:creator><![CDATA[Ian Gray]]></dc:creator>
            <pubDate>Tue, 11 Apr 2017 06:00:56 GMT</pubDate>
            <atom:updated>2017-04-11T06:00:55.448Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/577/0*Vpae_I2yTe3doReg.png" /><figcaption>Sigra’s Balanced Pressure Drilling System in use at the Liantang tunnel project</figcaption></figure><p><strong>Background</strong></p><p>The Liang Tang tunnel project comprises dual two-lane road tunnels, linking the Sha Tau Kok Road and Fanling Highway interchanges in Hong Kong, contracted primarily via a Dragages Hong Kong-Bouygues joint venture.</p><p>This tunnel project would require 4.8 kilometres of tunnelling through both soft soil and hard rock formations — the northern 500 metres consisting of soft soil tunnelling using an earth pressure balanced TBM, with cross tunnels also being excavated between the two main tunnels.</p><p>Enter Sigra: we provided specialist equipment to enable drilling and installation of the ground support and consolidation grouting, thus enabling the cross tunnel excavation through the soft soils to proceed. We installed the temporary ground support through pre-drilled holes.</p><p>Due to the nature of the formation, hydrostatic head acting on the tunnel, and the risk of liquefaction, all drilling and installation work had to be done under controlled conditions using borehole pressurisation equipment.</p><p><strong>Sigra design brief</strong></p><p>Our brief was to design well control equipment which would enable drilling and installation processes to be carried out safely, by:</p><ul><li>Maintaining a pressure seal at the tunnel wall penetration</li><li>Providing a balanced pressure while drilling and grouting so as to</li></ul><p>- Prevent inflow of water and soil into the tunnel</p><p>- Prevent excessive pressure being developed within the hole so as to avoid problems with ground liquefaction</p><p>We needed to design equipment for the restricted access within the tunnel for the drilling rig, as the main passageway could not be blocked from other construction traffic.</p><p>Three sealing modes were designed: a lip seal during drilling; an annular blow out preventer (BOP) to shut in on non rotating drill pipe; and a gate valve for extended shut in periods when the drill pipe was not in the hole.</p><p>Additional specifications include the ability to take tube-a-manchette cementing pipes, and a balanced pressure of between 50–250 kPa.</p><p>We based this equipment on Sigra’s well control system used in gas wells, with the key point of difference being the shortened length and precise choke used to control back pressure in the hole, while allowing passage of particles up to 40mm diameter.</p><p>The system we designed has been a key component in enabling the contractor to complete their cross tunnels.</p><p>For more information on Sigra’s tailored, custom solutions, <a href="http://sigra.com.au/contact-us/">please contact us here.</a></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=b59f87d6ef62" width="1" height="1" alt=""><hr><p><a href="https://medium.com/sigra-australia/balanced-pressure-drilling-system-deployed-at-liang-tang-tunnel-project-b59f87d6ef62">Balanced Pressure Drilling System deployed at Liang Tang Tunnel Project</a> was originally published in <a href="https://medium.com/sigra-australia">Sigra Australia</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Top 5 Specs — Field Data Logger]]></title>
            <link>https://medium.com/sigra-australia/top-5-specs-field-data-logger-7341e5f91fae?source=rss----9173f49d3ac7---4</link>
            <guid isPermaLink="false">https://medium.com/p/7341e5f91fae</guid>
            <category><![CDATA[android]]></category>
            <category><![CDATA[geology]]></category>
            <category><![CDATA[iot]]></category>
            <category><![CDATA[logger]]></category>
            <dc:creator><![CDATA[Ian Gray]]></dc:creator>
            <pubDate>Fri, 17 Mar 2017 03:49:33 GMT</pubDate>
            <atom:updated>2017-03-17T03:49:33.507Z</atom:updated>
            <content:encoded><![CDATA[<p><em>Sigra’s broadly applicable Field Data Logger technology is ideal for monitoring landslide, ground anchor, stress change, aquifer pressure, petroleum reservoir monitoring, and much more.</em></p><iframe src="https://cdn.embedly.com/widgets/media.html?src=https%3A%2F%2Fwww.youtube.com%2Fembed%2FgD15ohbf5wc%3Ffeature%3Doembed&amp;url=http%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3DgD15ohbf5wc&amp;image=https%3A%2F%2Fi.ytimg.com%2Fvi%2FgD15ohbf5wc%2Fhqdefault.jpg&amp;key=d04bfffea46d4aeda930ec88cc64b87c&amp;type=text%2Fhtml&amp;schema=youtube" width="854" height="480" frameborder="0" scrolling="no"><a href="https://medium.com/media/7fee580df59a0c93589fd15cf59be8c0/href">https://medium.com/media/7fee580df59a0c93589fd15cf59be8c0/href</a></iframe><h3>1. Plenty of Storage</h3><p>The Sigra Data Logger V9 comes with a 4 GB micro-SD card built-in to permit lifetime storage.</p><h3>2. Improved Resolution</h3><p>By storing the records in a 32-bit floating point format, improved resolution of 0.001 Hz is available for Vibrating Wires without affecting coefficients for previously installed transducers. This allows seamless upgrade of existing Vibrating Wire installations for improved resolution.</p><p>For Vibrating Wires used in surface applications (strain gauge, shallow piezos etc.), the temperature drift will be significant at these resolutions.</p><h3>3. Stable Clocks</h3><p>The internal clock chip with a built-in crystal oscillator has a time drift of less than 2 minutes a year across the full operating temperature range. Less than 20 seconds of drift is achievable if maintained between 10 and 40 degrees Celsius.</p><h3>4. Low Voltage Disconnect</h3><p>The V9 Data Logger (IP65 version) now has a built-in Low Voltage Disconnect (LVD) to protect the batteries from extreme discharge. This prevents the early failure of cells.</p><h3>5. Alarms</h3><p>The loggers have an alarm capability that permits them to detect when a value exceeds a threshold value, rate or both. The logger can then send a warning via SMS message (requires a 3G modem), trigger an output and store the alarm as a flag when downloaded. Alarms are sent through the local logger network to permit warning devices across the site to be activated.</p><p>To find out more, <a href="http://sigra.com.au/contact-us/"><strong>contact us</strong></a>, or <a href="http://sigra.com.au/products/data-acquisition/field-data-loggers/"><strong>read more here</strong></a>.</p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=7341e5f91fae" width="1" height="1" alt=""><hr><p><a href="https://medium.com/sigra-australia/top-5-specs-field-data-logger-7341e5f91fae">Top 5 Specs — Field Data Logger</a> was originally published in <a href="https://medium.com/sigra-australia">Sigra Australia</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Getting to the heart of Real Rock Properties]]></title>
            <link>https://medium.com/sigra-australia/getting-to-the-heart-of-real-rock-properties-7c02bdad1359?source=rss----9173f49d3ac7---4</link>
            <guid isPermaLink="false">https://medium.com/p/7c02bdad1359</guid>
            <category><![CDATA[mining]]></category>
            <category><![CDATA[data-science]]></category>
            <category><![CDATA[coal-industry]]></category>
            <category><![CDATA[civil-engineering]]></category>
            <dc:creator><![CDATA[Ian Gray]]></dc:creator>
            <pubDate>Fri, 17 Mar 2017 03:08:00 GMT</pubDate>
            <atom:updated>2017-03-17T03:10:12.350Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*bAKSI9Jt0U5iXmdN.jpg" /></figure><p><em>The models and methodologies of determining rock properties and predicting rock behaviour are numerous, but are they all equally effective?</em></p><p>Designing tunnels, mines or rock slopes requires a model with which to predict their behaviour so that failure may be avoided.</p><p>Failure may be defined in all cases as unacceptable deformation, but what defines <em>acceptable</em> deformation? It depends on the application.</p><p>A tunnel for a mass transit rail system, for example, is likely to have a far lower tolerance of deformation than the back of a stope, where failure means collapse to the extent that it leads to dilution of the ore being mined.</p><h4>Models of deformation are dependent on the properties of the rock.</h4><p>Most of these models are based on the elastic analysis of a material that has a constant, single modulus up until the point of failure. This applies to numerical as well as to analytical models.</p><p>Where numerical models incorporate non-linear behaviour there is little experimental basis for determining what properties should be used.</p><p>Unfortunately, an engineer is restricted to designing on limited laboratory data, assisted by back analysis of structures that already exist.</p><p>The use of back analysis presumes that the engineer has an adequate model of stress-strain behaviour for which to derive suitable parameters. Such models are lacking.</p><h4>‘It’s Complicated’</h4><p>Complicating the behaviour of rock is a general lack of understanding of the role that fluid plays in its behaviour.</p><p>While the concept of effective stress is generally applied in soils, it is not in rock — which is troubling, as it’s no less important.</p><p>Within rock there are significant differences between the rock matrix and joints, and the way in which they respond to fluid pressure.</p><h4>What’s Wrong With Uniaxial Testing?</h4><p>Frequently the only tests undertaken on rock to determine its properties are uniaxial tests for strength.</p><p>Some of these tests may be enhanced by measurement of strain, but they’re rarely presented to show how the material properties vary with stress levels.</p><p>Where triaxial testing is employed, it is for the purpose of determining the ultimate strength of the rock, rather than its constitutive properties prior to failure.</p><p>But here’s the thing: <em>all </em>design — <a href="http://sigra.com.au/research/the-measurement-of-rock-stress-for-tunnelling/"><strong>be it a mass transit system tunnel</strong></a> or a <a href="http://sigra.com.au/research/the-anisotropy-and-inhomogeneity-of-coal-permeability-and-interconnection-of-adjacent-seams/"><strong>coal mine</strong></a> — is based upon knowing what these properties are.</p><h4>Our Solution</h4><p>To overcome these shortcomings,<a href="http://sigra.com.au/services/geomechanics/rock-properties/"><strong> Sigra has built equipment</strong></a> that permits it to load HQ (63.5 mm diameter), and HQ-3 (60.9 mm diameter) core with axial and confining pressure, and with internal fluid pressure while measuring the rock deformation.</p><figure><img alt="Testing a rock specimen" src="https://cdn-images-1.medium.com/max/1024/1*FCFE2eKsAm6vWUwSgkb7PQ.jpeg" /><figcaption>Specimen ready for triaxial testing to determine vertical and horizontal Young’s moduli and Poisson’s ratio</figcaption></figure><p>A significant number of tests have been undertaken on siltstones and sandstones.</p><h4>Young’s Modulus, Poisson’s Ratio</h4><p>The findings are that Young’s modulus is highly dependent on the mean stress, while Poisson’s ratio is dependent on the shear and mean stress. Anisotropy can also be highly important, with some samples showing ratios of 1:3 for stiffness transverse to the bedding compared to that parallel to it.</p><figure><img alt="graph of young&#39;s modulus versus stress" src="https://cdn-images-1.medium.com/max/640/1*-73UpHAuJAdveFSVL3FOQQ.png" /><figcaption>Vertical and horizontal Young’s moduli versus sum of axial and confining stress</figcaption></figure><figure><img alt="graph of poisson&#39;s ratio versus stress" src="https://cdn-images-1.medium.com/max/640/1*SZ4SxIltIt5C2XpzWo6hLA.png" /><figcaption>Poisson’s ratio versus sum of axial and confining stress. Vv = Poisson’s ratio= -horizontal strain change/vertical strain change. Vh = Poisson’s ratio associated with lateral loading</figcaption></figure><p>The action of fluid pressure within the rock also needs to be determined. In some rock its effect approaches that of soil, with a Biot’s coefficient of near-unity, while in other it is virtually zero.</p><p>For a better understanding of the effects of fluid within rock, we strongly recommend the paper <a href="http://sigra.com.au/research/effective-stress-in-rock/"><strong>‘Effective Stress in Rock’ by Dr Ian Gray</strong></a>, which was presented at the Eighth International Conference on Deep and High Stress Mining in Perth on 28 March.</p><p>Joints behave differently to the host rock. Their mineralogy and degree of openness mean that they have their own unique properties.</p><p><strong>Accuracy in modeling and testing is absolutely crucial to any project. Sigra is equipped with the academic discipline and resources to accurately predict rock behaviour based on a variety of project types — namely civil tunnelling projects and mine design.</strong></p><p><a href="http://sigra.com.au/contact-us/"><strong>Please contact us to discuss a tailored solution.</strong></a></p><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=7c02bdad1359" width="1" height="1" alt=""><hr><p><a href="https://medium.com/sigra-australia/getting-to-the-heart-of-real-rock-properties-7c02bdad1359">Getting to the heart of Real Rock Properties</a> was originally published in <a href="https://medium.com/sigra-australia">Sigra Australia</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
        <item>
            <title><![CDATA[Permeability in civil and mining applications — What to look out for]]></title>
            <link>https://medium.com/sigra-australia/permeability-in-civil-and-mining-applications-what-to-look-out-for-cb50135df3ea?source=rss----9173f49d3ac7---4</link>
            <guid isPermaLink="false">https://medium.com/p/cb50135df3ea</guid>
            <category><![CDATA[permeability]]></category>
            <category><![CDATA[environment]]></category>
            <category><![CDATA[drill-stem-test]]></category>
            <category><![CDATA[civil-engineering]]></category>
            <category><![CDATA[coal]]></category>
            <dc:creator><![CDATA[Ian Gray]]></dc:creator>
            <pubDate>Wed, 01 Mar 2017 05:21:57 GMT</pubDate>
            <atom:updated>2017-03-01T05:21:57.129Z</atom:updated>
            <content:encoded><![CDATA[<figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*-JKSqqU212KS3wnH.png" /></figure><p>With better-tailored equipment and a revised methodology for shallow permeability testing in civil and mining projects, we can reduce the margin for design error.</p><p>Owing to the constraints of time and money, the two most widely used methods for permeability testing in civil and mining — The Falling Head Test and the Packer Test — have numerous pitfalls and provide inaccurate results.</p><p>The Problem — Packer Test</p><ul><li>If no attempt is made to determine the transient response in the ground, then the desired information in the rock mass is lost in near-well bore behaviour.</li></ul><p>Our Solution</p><p>Adopt the oilfield Drill Stem Test (DST)</p><ul><li>The most effective way to do this is to adopt the analogue of the oilfield DST for civil and mining applications.</li><li>We have used these extensively for the coal seam gas and deep coal mining clients, and we tailor equipment and analysis to suit these applications.</li><li>The technique enables the separation of well bore loss effects from the response of the greater rock mass.</li></ul><p>The Problem — Falling Head Test</p><ul><li>It’s difficult to separate pressure loss around the well bore from the response of the soil outside the well’s zone of influence.</li><li>And worse still: near-well bore behaviour is compromised by the injection process. Ie- soil particles are going to end up inhibiting flow into the ground.</li><li>Essentially, not being able to separate near-well bore pressure loss from the transient response in the ground is going to give you misleading results.</li></ul><p>Our Solution</p><p>Adopt an analogue of the oilfield Drill Stem Test (DST) suitable for soils or rock conditions.</p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*VNgJDRLG3pnxU_YR.png" /></figure><p>The Question — inhomogeneity or anisotropy?</p><p>Testing for permeability in a single hole provides no information on anisotropy or on storage in the ground. Multiple hole tests answer the question of inhomogeneity, but still do not provide information on anisotropy or storage.</p><p>A conventional well test with a single production well will provide information on anisotropy and storage, but not on inhomogeneity.</p><p>Our Solution</p><ul><li>Sequentially testing individual boreholes and place piezometers in these as each test is finished.</li><li>Move to the next hole and repeat the test process. This test will send a pressure transient to those boreholes drilled before and fitted with piezometers.</li><li>The most convenient way to test each well is by conducting a DST in the test zones. Hence the name “pulsed DST”.</li><li>This method enables multiple measurements of mean permeability and directional permeability, so that both inhomogeneity and anisotropy may be assessed.</li></ul><p>For further reading — <a href="http://sigra.com.au/news/towards-a-technology-for-permeability-testing-in-civil-projects/"><strong>you will find a longform of this post here</strong></a>.</p><p><strong><em>If you have queries about tailored solutions or Sigra products in general, please don’t hesitate to </em></strong><a href="http://sigra.com.au/contact-us/"><strong><em>contact us</em></strong></a><strong><em>.</em></strong></p><figure><img alt="" src="https://cdn-images-1.medium.com/max/1024/0*nl23syKry9KyrFM5.png" /></figure><img src="https://medium.com/_/stat?event=post.clientViewed&referrerSource=full_rss&postId=cb50135df3ea" width="1" height="1" alt=""><hr><p><a href="https://medium.com/sigra-australia/permeability-in-civil-and-mining-applications-what-to-look-out-for-cb50135df3ea">Permeability in civil and mining applications — What to look out for</a> was originally published in <a href="https://medium.com/sigra-australia">Sigra Australia</a> on Medium, where people are continuing the conversation by highlighting and responding to this story.</p>]]></content:encoded>
        </item>
    </channel>
</rss>