https://oneuppuzzle.com/ I finished the puzzle #646 (8x8) in 4 minutes, 41 seconds in One Up Puzzle.
- 2 Posts
- 14 Comments
I am 190cm and got a Brompton C-Line with Telescopic Seatpost. The seller recommended it for my size - i use 5 cm of it.
datenhamster@feddit.orgto
Open Source@lemmy.ml•Looking for: GPX Library/viewer for biking
1·1 year agoNewest version is working for me. So, let’s see, what the future brings.
datenhamster@feddit.orgto
Open Source@lemmy.ml•Looking for: GPX Library/viewer for biking
2·1 year agoI did and i am very active in the bug reports. I think it will need minimum a year to be stable and bug free enough.
datenhamster@feddit.orgto
Open Source@lemmy.ml•Looking for: GPX Library/viewer for biking
2·1 year agoThis looks nice. Only thing missing for me is Tiles like squadrats.
datenhamster@feddit.orgto
BuyFromEU@feddit.org•Finally, a Linux laptop with a brilliant display and performance that rivals my MacBook (from Germany)English
6·1 year agoI have exactly this laptop - with 96 GB RAM. It is really as good as described.
Just bought an Tuxedo InfinityBook. Very nice piece of hardware.
datenhamster@feddit.orgOPto
homeassistant@lemmy.world•Automation switching TRV on and off in 1° range over targetEnglish
1·1 year agoOk, now I know why. without the +1 the automation does not trigger when the temperature is over the target and the TRVs running on idle. The +1 triggers the automation and switches them off until the room temperature is under the target temperature. So it does not explain why the mode is switched from heat to off or the other way around in the target +1° range.
datenhamster@feddit.orgOPto
homeassistant@lemmy.world•Automation switching TRV on and off in 1° range over targetEnglish
1·1 year agoThank you. I will look at it
datenhamster@feddit.orgOPto
homeassistant@lemmy.world•Automation switching TRV on and off in 1° range over targetEnglish
1·1 year agoI was young and… I don’t know why I used it a few years ago. I will try your suggestion.
datenhamster@feddit.orgOPto
homeassistant@lemmy.world•Automation switching TRV on and off in 1° range over targetEnglish
1·1 year agoI use the generic thermostat but I want to switch the TRVs to different temperatures/states depending on a schedule and if we are at home or not. The automation changed over the last 3 or 4 years but basicly it was one of my first experiments with HA. It worked flawless and did what it should.
Maybe it’s not the best or refined but it worked.
triggers: - entity_id: - sensor.wohnzimmer_temp trigger: state conditions: - condition: and conditions: - condition: state state: "off" entity_id: binary_sensor.balkontur_contact - condition: state entity_id: input_boolean.wohnzimmer_heizung state: "on" - condition: template value_template: >- {% if states('input_boolean.away_mode')=='off' %} {% if states('schedule.testkalender')=='on' %} {{ states('sensor.wohnzimmer_temp') | float < states('input_number.wohnzimmer_temperatur_tag') | float + 1 }} {% else %} {{ states('sensor.wohnzimmer_temp') | float < states('input_number.wohnzimmer_temperatur_nacht') | float + 1 }} {% endif %} {% else %} {{ (states('sensor.wohnzimmer_temp') | float) | round < states('input_number.temperatur_away_mode') | float + 1 }} {% endif %} enabled: true actions: - action: climate.set_temperature target: entity_id: climate.heizung_wohnzimmer data: temperature: | {% if states('schedule.testkalender')=='on' %} {{ states('input_number.wohnzimmer_temperatur_tag') | int + states('input_number.wohnzimmer_heizung_offset') | int }} {% else %} {{ states('input_number.wohnzimmer_temperatur_nacht') | int }} {% endif %} hvac_mode: | {% if states('input_boolean.away_mode')=='off' %} {% if states('schedule.testkalender')=='on' %} {% if states('sensor.wohnzimmer_temp') | float < states('input_number.wohnzimmer_temperatur_tag') | float %} heat {% else %} off {% endif %} {% else %} {% if states('sensor.wohnzimmer_temp') | float < states('input_number.wohnzimmer_temperatur_nacht') | float %} heat {% else %} off {% endif %} {% endif %} {% else %} {% if states('sensor.wohnzimmer_temp') | float < states('input_number.temperatur_away_mode') | float %} heat {% else %} off {% endif %} {% endif %} mode: single
datenhamster@feddit.orgOPto
homeassistant@lemmy.world•Automation switching TRV on and off in 1° range over targetEnglish
2·1 year agoThey are Sonoff TRVZB. Bosch changed the firmware and with 3.7.4 the TRVs startet to recalibrate and reboot at random times. Sometimes 15 minutes in a row. Bosch said: Thats your valves, change them, not our fault.
datenhamster@feddit.orgOPto
OpenStreetMap community@lemmy.ml•How to map this tunnel for waterEnglish
4·1 year agocool, thank you


In German, but yes, made my own CO2-Sensors.
https://basteln.webhafen.de/2023/03/co2-sensor-selbst-bauen